940 resultados para Diagnostic radiology
Resumo:
High-resolution ultrasound is becoming increasingly important in the diagnosis of carpal tunnel syndrome (CTS). Most studies define cut-off values of the cross-sectional area (CSA) of the median nerve in different locations. The individual range of nerve swelling, the size of the nerve, and its CSA are not addressed. The aim of the study is to define the intra- and interobserver reliability of diagnostic ultrasound using two different cross-sectional areas of the median nerve at the carpal tunnel in predefined locations.
Resumo:
The aim of this article is to disclose the characteristics of postmortem forensic imaging; give an overview of the several possible findings in postmortem imaging, which are uncommon or new to clinical radiologists; and discuss the possible pitfalls. Unspecific postmortem signs are enlisted and specific signs shall be presented, which are typical for one cause of death. Unspecific signs. Livor mortis may not only be seen from the outside, but also inside the body in the lungs: in chest CT internal livor mortis appear as ground glass opacity in the dependent lower lobes. The aortic wall is often hyperdense in postmortem CT due to wall contraction and loss of luminal pressure. Gas bubbles are very common postmortem due to systemic gas embolism after major open trauma, artificial respiration or initial decomposition; in particular putrefaction produces gas bubbles globally. Specific signs. Intracranial bleeding is hyperattenuating both in radiology and in postmortem imaging. Signs of strangulation are hemorrhage in the soft tissue of the neck like skin, subcutaneous tissue, platysma muscle and lymph nodes. The "vanishing" aorta is indicative for exsanguination. Fluid in the airways with mosaic lung densities and emphysema (aquosum) is typical for fresh-water drowning.
Resumo:
Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
The questions of cause and manner of death are the most pressing ones in any forensic investigation. Traditionally, autopsy is the means to provide answers to these questions and despite the increasing use of CT and MR in the post-mortem setting, imaging has usually been an adjunct to forensic autopsy. Here we describe a case where post-mortem CT and MR were performed instead of autopsy, at the request of the responsible public prosecutor. The forensic conclusions derived from imaging, including cause and manner of death were accepted by the legal authorities, thereby setting precedence for future cases. This case represents a landmark in forensic medicine and is another step toward the full realization of minimally invasive forensic autopsy.
Resumo:
Despite a growing number of identified genetic causes of monogenetic disorders, early molecular testing is rarely applied in daily nephrologic practice. In selected cases and to answer specific questions, molecular testing however can be helpful for the specialist. The future significance of genetic testing most likely lies in the area of individual risk profiling for polygenetic disorders. The basis for this testing however has yet to be established.
Resumo:
Susceptibility-weighted MR imaging (SWI) is usually obtained without administration of intravenous gadolinium (Gd). However, it is occasionally necessary to perform SWI after Gd is injected. The effects of Gd on SWI have not been systematically examined. The aim of this prospective study was to investigate whether performing SWI after Gd would influence the diagnostic image quality, parenchymal signal and vascular enhancement. An additional aim is to suggest potential future applications for Gd-enhanced SWI.
Resumo:
Humans perceive the content (gist) of a scene very rapidly within about 40 ms [Castelhano and Henderson, 2008 Journal of Experimental Psychology Human Perception and Performance 43(3) 660-675]. It has also been demonstrated that colours contribute to the perception of the gist of a scene if the colours are diagnostic for the distinction of scenes (Oliva and Schyns, 2000 Cognitive Psychology 41 176-210). We presented 320 coloured photographs of 2 diagnostic (mountains and coasts) and 2 nondiagnostic colour scenes (cities and rooms), 80 per category, in a masking paradigm. The mask consisted of randomly distributed colour patches. SOA was varied between 20 and 80 ms, in steps of 20 ms and subjects had to indicate the gist of the scene (4AFC). A control condition without masking was also included. In line with previous results we have found that the gist of nondiagnostic coloured scenes is extracted within 40 ms. However, if colour comes into play, the extraction of the scene gist is prolonged by about 20 ms. A possible reason for this outcome might be that nondiagnostic colour scenes are identified by their luminance components which are processed faster than the colour information, which in turn mediates the identification of diagnostic colour scenes
Resumo:
This review summarizes current evidence based on pertinent literature on low-dose computed tomography angiography (CTA) of the body. Various strategies for optimizing CTA protocols with the aim to lower the radiation dose while maintaining the diagnostic accuracy of the examination are summarized. To date, various publications have demonstrated that CTA of the body can be performed at a low radiation dose while providing high quality information. Nevertheless, a number of questions still need to be answered, including the optimal combination of tube voltage and tube current settings, as well as the appropriate protocol parameters in relation to the body physiognomy and the specific body region imaged.
Resumo:
Extracranial application of diffusion-weighted magnetic resonance imaging (MRI) has gained increasing importance in recent years. As a result of technical advances, this new non-invasive functional technique has also been applied in head and neck radiology for several clinical indications. In cancer imaging, diffusion-weighted MRI can be performed for tumour detection and characterization, monitoring of treatment response as well as the differentiation of recurrence and post-therapeutic changes after radiotherapy. Even for lymph node staging promising results have been reported recently. This review article provides overview of potential applications of diffusion-weighted MRI in head and neck with the main focus on its applications in oncology.
Resumo:
The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.
Resumo:
The best available test for the diagnosis of upper extremity deep venous thrombosis (UEDVT) is contrast venography. The aim of this systematic review was to assess whether the diagnostic accuracy of other tests for clinically suspected UEDVT is high enough to justify their use in clinical practise and to evaluate if any test can replace venography.