965 resultados para Dental documentation
Resumo:
Objectives. Evaluate the flexural strength (sigma) and subcritical crack growth (SCG) under cyclic loading of glass-infiltrated alumina-based (IA, In-Ceram Alumina) and zirconia-reinforced (IZ, In-Ceram Zirconia) ceramics, testing the hypothesis that wet environment influences the SCG of both ceramics when submitted to cyclic loading.Methods. Bar-shaped specimens of IA (n = 45) and IZ ( n = 45) were fabricated and loaded in three-point bending (3P) in 37 degrees C artificial saliva (IA(3P) and IZ(3P)) and cyclic fatigued (F) in dry (D) and wet (W) conditions (IA(FD), IA(FW), IZ(FD), IZ(FW)). The initial sigma and the number of cycles to fracture were obtained from 3P and F tests, respectively. Data was examined using Weibull statistics. The SCG behavior was described in terms of crack velocity as a function of maximum stress intensity factor (K(Imax)).Results. The Weibull moduli (m = 8) were similar for both ceramics. The characteristic strength (sigma(0)) of IA and IZ was and 466 MPa 550 MPa, respectively. The wet environment significantly increased the SCG of IZ, whereas a less evident effect was observed for IA. In general, both ceramics were prone to SCG, with crack propagation occurring at K(I) as low as 43-48% of their critical K(I). The highest sigma of IZ should lead to longer lifetimes for similar loading conditions.Significance. Water combined with cyclic loading causes pronounced SCG in IZ and IA materials. The lifetime of dental restorations based on these ceramics is expected to increase by reducing their direct exposure to wet conditions and/or by using high content zirconia ceramics with higher strength. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
In this article, we describe a midsymphyseal distraction osteogenesis treatment with a novel dentally supported appliance. This approach differs from that used in previous reports because the incisors were allowed to move during the distraction procedure. This report shows that midsymphyseal distraction osteogenesis can be used to expand both arches to produce a wider smile. Borderline cases can be treated with this technique without the compromising effects commonly observed with conventional therapy. (Am J Orthod Dentofacial Orthop 2009;135:530-5)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207). and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.
Resumo:
Carinated teeth are common in Mesoeucrocodylia, and the occurrence of denticles over the carinae is related to high predacious species, often referred as ziphodont. This characteristic is broadly recognized as homoplastic. Carinae morphology is cryptic, difficult to be studied under common techniques, and Scanning Electronic Microscopy (SEM) allows the access to detailed information, offering a higher degree of confidence. Previous SEM study allowed the recognition of true/false ziphodont patterns, according to the morphology of the denticles, but such studies on gondwanan mesoeucrocodyles are uncommon. Mariliasuchus amarali is an Upper Cretaceous notosuchian mesoeucrocodyle from South America (Bauru Group, Brazil), with carinated teeth and specialized dentition. Its geological and biochronological distribution are reappraised. SEM study of two teeth shows carinae composed of isolated tuberous anisomorphic true denticles, supporting previous study. Enamel ornamentation does not develop over the carinae, and fabric becomes anastomosed in middle and posterior teeth. Carinae only occur in posterior molariform teeth, related to food processing. Morphological variability of Mariliasuchus is commented, focusing on dentition. Overall characteristics, molariform morphology and wear planes support a non-predacious habit for Matiliasuchus. Matiliasuchus pattern could not be related to true/false ziphodont patterns, either by morphology or function, and is defined as ziphomorph. Ziphomorph pattern is evaluated within the range of mesoeucrocodyles. The detailed study of homoplastic characteristics, such as dental carinae, may provide useful apomorphic information for cladistic analysis.
Resumo:
The purpose of this study was to examine histologically the effects of propolis topical application to dental sockets and skin wounds. After topical application of either a 10% hydro-alcoholic solution of propolis or 10% hydro-alcoholic solution alone, cutaneous wound healing and the socket wound after tooth extraction were examined. The rats were sacrificed at 3, 6, 9, 15 and 21 days after the operation. The specimens were subjected to routine laboratory studies after staining with hematoxylin and eosin. It was concluded that topical application of propolis hydro-alcoholic solution accelerated epithelial repair after tooth extraction but had no effect on socket wound healing.
Resumo:
The cervical hypersensitivity tooth was analysed and treated by application of a varnish with high fluoride ions content (Duraphat) and of a glass ionomer cement usually indicated to cavity lining (XR-ionomer-Kerr). This technique was applied in sixty-seven teeth of Clinic Graduation patients (Faculdade de Odontologia de Araçatuba) and demonstrated a high index of satisfactory results. The clinical findings of this study relate that, this technique is more one method of choose by clinicians.
Resumo:
Thirty six female mice were injected on the 12th day of the gestational period with 0.2 ml of distilled water (control group) or of an acqueous solution containing either 30 mg/Kg or 50 mg/Kg of body weight of cyclophosphamide (treated group). The animal were killed at 24, 48, 72, 96 and 120 hours after the injection and 3 days after birth. It was verified that cyclophosphamide interferes on the tooth germ development and that this effect is in directly ratio of the doses used.
Resumo:
It was verified the penetration of phosphoric acid into 3 commercial calcium hydroxide-based cements (Life, Renew and Prisma VLC Dycal). The colorimetric method employed permitted the identidication of phosphorus amount in representative samples of 6 successive layers 0.1 mm thick of each material. The acid etching used were the commercial products Scotchbond Etching Gel--3M at 36.114% by weight and Solução Condicionadora--Johnson & Johnson at 36.054% by weight. The contact time was 60 seconds. The result showed that layers 0.1 mm tick for Life and Prisma VLC Dycal and 0.2 mm thick for Renew were able to block the penetration of phosphoric acid solution whereas layers 0.1 mm thick for the 3 cements were able to block the penetration of phosphoric acid gel.
Resumo:
The effects of ultrasound on the wound healing process after teeth extractions were studied histologically. The right upper incisor was extracted in 56 rats. They were divided into 2 groups, one control (I) and one experimental (II). Group II received ultrasound stimulation that was applied with the frequency of repetition of 1,000 Hz and pulse length of 2,000 us continuously, during five minutes daily since the extraction day until 24 hours before the death. The rats were sacrificed at 3, 6, 9, 12, 15, 18, and 21 postoperative days. The results showed a precocious granulation tissue formation, faster remodeling of osseous ridges, and consequently acceleration of the alveolar wound healing process.
Resumo:
The present study was designed to evaluate the metallurgical properties of an experimental, low-cost copper-zinc-aluminum-nickel alloy for dental castings. Some specimens were subjected to heat treatment after induction casting. The extent of corrosion was determined by measuring weight loss of specimens stored in a sodium sulfite solution. In the as-cast specimens, tests demonstrated the presence of three phases: the first consisted of copper-zinc-aluminum, the second was similar but lower in copper and aluminum, and the third consisted of an intermetallic compound of manganese-nickel-phosphorus. After heat treatment, the first phase remained relatively constant, the second was converted to Cu3Al, and the third increased in volume. The weight loss from the as-cast specimens was eight times that of the heat-treated specimens. It was concluded that the heat treatment substantially changed the microstructure and improved the corrosion resistance of the experimental alloy.
Resumo:
In orofacial implantology there are many types of implants for the different systems. Among these is the implant surface type, e.g., a screw type, cylindrical and laminar. Furthermore, the implants are different in their dimensions, their metal composition, their surface condition, such as smooth, grit or layered surfaces and in their methods of application. Two different self-tapping implants, one smooth and the other grit-blasted, are screwed into the bone, and another one with a plasma of titanium coating, which is also in a screw form but with greater spaces between the screw threads are compared. The greatest amount of bone deposition in the bone/implant interface was encountered in the latter one, the smooth surfaced implant being in second place. All of these systems can alter the implant healing process and to demonstrate this, we injected bone markers in the rabbits over different periods of time so as to observe the different areas of bone deposition in the tibias where the implants had been inserted. The bone tracers used were Alizarin, Calcein and Xylenol-orange. The amount of deposition was calculated by using the method of surface morphometry.
Resumo:
The premature loss of primary teeth may harm the normal occlusal development, although there are debates relating to the necessity of using space maintainer appliances. The aim of the study is to evaluate the changes in the dental arch perimeter and the space reduction after the premature loss of the lower first primary molar in the mixed dentition stage. The sample consists of 4 lower arch plaster models of 31 patients, within the period of pre-extraction, 6, 12 and 18 months after the lower first primary molar extraction. A reduction of space was noted with the cuspid dislocation and the permanent incisors moving toward the space of the extraction site. It was concluded that the lower first molar primary premature loss, during the mixed dentition, implicates an immediate placement of a space maintainer.