990 resultados para DIODE INTERFEROMETER
Resumo:
The application of multi-wavelength holography for surface shape measurement is presented. In our holographic setup a Bi12TiO 20 (BTO) photorefractive crystal was the holographic recording medium and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. The holographic imaging with multimode lasers results in multiple holograms in the BTO. By employing such lasers the resulting holographic image appears covered of interference fringes corresponding to the object relief and the interferogram spatial frequency is proportional to the diode laser free spectral range (FSR). We used a Fabry-Perot étalon at the laser output for laser mode selection. Thus, larger effective values of the laser FSR were achieved, leading to higher-spatial frequency interferograms and therefore to more sensitive and accurate measurements. The quantitative evaluation of the interferograms was performed through the phase stepping technique (PST) and the phase map unwrapping was carried out through the Cellular-Automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared, concerning measurement noise and visual inspection.
Resumo:
Laser-assisted hatching is little documented in the literature regarding its efficacy in cryopreserved-thawed (CT) embryo transfer cycles. The aim of the present study was to evaluate in a randomized manner the efficacy of thinning one quarter of the zona pellucida of CT embryos to a depth of 50-80% of the original thickness, via laser treatment (the qLZT-AH procedure), in improving implantation and pregnancy rates. Two populations were studied: population I, patients who had all their supernumerary embryos cryopreserved, regardless of their morphology, and population II, patients at risk of ovarian hyperstimulation syndrome who had all their embryos cryopreserved. Artificial and natural protocols were used for the embryo transfers. A total of 350 laser-thinned CT embryos were compared with 352 intact zona embryos. No difference in implantation or pregnancy rate was found after using qLZT-AH in either population. These findings suggest that qLZT-AH should not be routinely performed in cryopreserved embryo programmes.
Resumo:
The aim of this study was to evaluate the influence of different light-curing units on the tensile bond strength and microhardness of a composite resin (Filtek Z250 - 3M/ESPE). Conventional halogen (Curing Light 2500 - 3M/ESPE; CL) and two blue light emitting diode curing units (Ultraled - Dabi/Atlante; UL; Ultrablue IS - DMC; UB3 and UB6) were selected for this study. Different light intensities (670, 130, 300, and 600 mW/cm2, respectively) and different curing times (20s, 40s and 60s) were evaluated. Knoop microhardness test was performed in the area corresponding to the fractured region of the specimen. A total of 12 groups (n=10) were established and the specimens were prepared using a stainless steel mold composed by two similar parts that contained a cone-shaped hole with two diameters (8.0 mm and 5.0 mm) and thickness of 1.0 mm. Next, the specimens were loaded in tensile strength until fracture in a universal testing machine at a crosshead speed of 0.5 mm/min and a 50 kg load cell. For the microhardness test, the same matrix was used to fabricate the specimens (12 groups; n=5). Microhardness was determined on the surfaces that were not exposed to the light source, using a Shimadzu HMV-2 Microhardness Tester at a static load of 50 g for 30 seconds. Data were analyzed statistically by two-way ANOVA and Tukey's test (p<0.05). Regarding the individual performance of the light-curing units, there was similarity in tensile strength with 20-s and 40-s exposure times and higher tensile strength when a 60-s light-activation time was used. Regarding microhardness, the halogen lamp had higher results when compared to the LED units. For all light-curing units, the variation of light-exposure time did not affect composite microhardness. However, lower irradiances needed longer light-activation times to produce similar effect as that obtained with high-irradiance light-curing sources.
Resumo:
In this paper is proposed and analyzed a digital hysteresis modulation using a FPGA (Field Programmable Gate Array) device and VHDL (Hardware Description Language), applied at a hybrid three-phase rectifier with almost unitary input power factor, composed by parallel SEPIC controlled single-phase rectifiers connected to each leg of a standard 6-pulses uncontrolled diode rectifier. The digital control allows a programmable THD (Total Harmonic Distortion) at the input currents, and it makes possible that the power rating of the switching-mode converters, connected in parallel, can be a small fraction of the total average output power, in order to obtain a compact converter, reduced input current THD and almost unitary input power factor. The proposed digital control, using a FPGA device and VHDL, offers an important flexibility for the associated control technique, in order to obtain a programmable PFC (Power Factor Correction) hybrid three-phase rectifier, in agreement with the international standards (IEC, and IEEE), which impose limits for the THD of the AC (Alternate Current) line input currents. Finally, the proposed control strategy is verified through experimental results from an implemented prototype. ©2008 IEEE.
Resumo:
In this paper is proposed and analyzed a digital hysteresis modulation using a FPGA (Field Programmable Gate Array) device and VHDL (Hardware Description Language), applied at a hybrid three-phase rectifier with almost unitary input power factor, composed by parallel SEPIC controlled single-phase rectifiers connected to each leg of a standard 6-pulses uncontrolled diode rectifier. The digital control allows a programmable THD (Total Harmonic Distortion) at the input currents, and it makes possible that the power rating of the switching-mode converters, connected in parallel, can be a small fraction of the total average output power, in order to obtain a compact converter, reduced input current THD and almost unitary input power factor. Finally, the proposed digital control, using a FPGA device and VHDL, offers an important flexibility for the associated control technique, in order to obtain a programmable PFC (Power Factor Correction) hybrid three-phase rectifier, in agreement with the international standards (IEC, and IEEE), which impose limits for the THD of the AC (Alternate Current) line input currents. The proposed strategy is verified by experiments. © 2008 IEEE.
Resumo:
Casearia sylvestris Swartz (Salicaceae) is a tree or shrub distributed widely in Brazil, where it is used in popular medicine. Several bioactive clerodane diterpenes typical of Casearia have been isolated from this species (e.g. casearins and casearvestrins). The main objective of this study was to identify clerodane diterpenes in various organs of C. sylvestris, using chromatographic and spectroscopic analytical techniques. The extracts of the different plant parts were analyzed by thin layer chromatography, high performance liquid chromatography with diode array detector and 1H nuclear magnetic resonance. In the chromatographic analysis, clerodane diterpenes isolated from C. sylvestris were used as standards, including rel-19Sacetóxi-18R- butanoilóxi-18,19- epóxi -6S -hidróxi -2R-(2-metilbutanoilóxi) -5S, 8R, 9R, 10S -cleroda-3,13(16),14-triene, isolated for the first time from the stems. Phytochemical profiles of the organs were produced, which indicated the presence of clerodane diterpenes in all parts of the plant, notably in the leaves. The results also suggest that the main clerodane diterpenes in the stems, flowers and roots had conjugated double-bond patterns that differed from those found in the leaves.
Resumo:
We studied the shape measurement of semiconductor components by holography with photorefractive Bi12TiO20 crystal as holographic medium and two diode lasers emitting in the red region as light sources. By properly tuning and aligning the lasers a synthetic wavelength was generated and the resulting holographic image of the studied object appears modulated by cos2-contour fringes which correspond to the intersection of the object surface with planes of constant elevation. The position of such planes as a function of the illuminating beam angle and the tuning of the lasers was studied, as well as the fringe visibility. The fringe evaluation was performed by the four stepping technique for phase mapping and through the branch-cut method for phase unwrapping. A damage in an integrated circuit was analysed as well as the relief of a coin was measured, and a precision up to 10 μm was estimated. © 2009 SPIE.
Resumo:
This paper proposal presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results of a 15kW prototype are also presented in this paper. © 2009 IEEE.
Resumo:
This paper presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results are also presented in this paper. © 2009 IEEE.
Resumo:
This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm X 5 mm) and covered with a Mylar strip. The tip of the lightcuring unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37°C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (α=0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the lightcuring unit and by its light energy density. © Operative Dentistry.
Resumo:
Authors - Magno AFF, Martins RP, Vaz LG, Martins LP Objectives - Evaluate the shear bond strength (SBS) and the adhesive remnant index (ARI) of indirect bonded lingual brackets using xenon plasma arc light, light-emitting diode (LED) and conventional quartz-tungsten-halogen light. Material and Methods - Lingual brackets were bonded indirectly to 60 premolars divided to three groups according to the curing light used: Group 1, plasma arc for 6 s; Group 2, LED for 10 s; and Group 3, halogen light for 40 s. After bonding, the specimens were subjected to a shear force until debonding. The debonding pattern was assessed and classified according to the ARI scores. The mean shear bond strengths were accessed by anova followed by the Student-Newman-Keuls test for multiple comparisons. ARI scores were assessed using the chi-square test. Results - The three groups showed significant differences (p < 0.001), with the averages of group 1 < group 2 < group 3. Groups showed no differences regarding ARI scores. Conclusion - Bonding lingual brackets indirectly with plasma arc, during 60% of the time used for the LED, produced lower SBS than obtained with the latter. Using LED during 25% of the time of the halogen light produced lower SBS than obtained with the latter. These differences did not influence the debonding pattern and are clinically acceptable according to the literature. © 2010 John Wiley & Sons A/S.
Resumo:
AIM: This study evaluated the temperature rise of the adhesive system Single Bond (SB) and the composite resins Filtek Z350 flow (Z) and Filtek Supreme (S), when polymerized by light-emitting diode (LED XL 3000) and quartz-tungsten halogen (QTH Biolux). METHODS: Class V cavities (3 yen2 mm) were prepared in 80 bovine incisors under standardized conditions. The patients were divided as follows: G1: Control; G2: SB; G3: SB + Z; G4: SB + S. The groups were subdivided into two groups for polymerization (A: QTH, B: LED). Light curing was performed for 40 s and measurement of temperature changes during polymerization was performed with a thermocouple positioned inside the pulp chamber. Data were statistically analyzed using ANOVA and Tukey tests. RESULTS: The factors material (P<0.00001) and curing unit (P<0.00001) had significant influence on temperature rise. The lowest temperature increase (0.15 degrees C) was recorded in G2 B and the highest was induced in G1 A (0.75 degrees C, P<0.05). In all groups, lower pulp chamber temperature measurements were obtained when using LED compared to QTH (P<0.05). CONCLUSION: QTH caused greater increases in tooth temperature than LED. However, both sources did not increase pulpal temperature above the critical value that may cause pulpal damage.
Resumo:
This study measured the critical temperature reaching time and also the variation of temperature in the surface of the cervical region and within the pulp chamber of human teeth submitted to dental bleaching using 35% hydrogen peroxide gel activated by three different light sources. The samples were randomly divided into 3 groups (n = 15), according to the catalyst light source: Halogen Light (HL), High Intensity Diode Laser (DL), and Light Emmited Diode (LED). The results of temperature variation were submitted to the analysis of variance and Tukey test with p < 0.05. The temperature increase (mean value and standard deviation) inside the pulp chamber for the HL group was 6.8 ± 2.8°C; for the DL group was 15.3 ± 8.8°C; and for the LED group was 1.9 ± 1.0°C for. The temperature variation (mean value and standard deviation) on the tooth surface, for the group irradiated with HL was 9.1 ± 2.2°C; for the group irradiated with DL were 25.7 ± 18.9°C; and for the group irradiated with LED were 2.6 ± 1.4°C. The mean temperature increase values were significantly higher for the group irradiated with DL when compared with groups irradiated with HL and LED (p < 0.05). When applying the inferior limits of the interval of confidence of 95%, an application time of 38.7 s was found for HL group, and 4.4 s for DL group. The LED group did not achieve the critical temperatures for pulp or the periodontal, even when irradiated for 360 s. The HL and DL light sources may be used for dental bleaching for a short period of time. The LED source did not heat the target tissues significantly within the parameters used in this study. © 2010 Pleiades Publishing, Ltd.
Resumo:
The use of low-level laser (LLL) may be an useful tool to promote reduction of muscular pain caused by TMD. Aim: This study evaluated the immediate efficacy of low-level laser therapy on women reporting pain and diagnosed with temporomandibular dysfunction (TMD). Methods: Diode laser (GaAlAs) at 790 nm wavelength (infrared spectrum) was applied as experimental treatment. Irradiations of 1.5 J/cm2 were made at 4 points of the temporomandibular joint (TMJ) and of 3 J/cm2 at 3 points in the temporal muscle. An electromyographic (EMG) evaluation of the masseter and anterior temporal was done at the following intervals: before, immediately after, 5 min and 20 min after laser application. Results: Comparison of the electrical activity at the times of measurement revealed a statistically significant difference in masseter muscles before (P=0.025) and immediately after (P=0.013) LLLT. Conclusions: Both masseter and temporal muscles showed a reduction in the measured EMG activities at all times after LLLT, and the temporal muscle showed higher EMG activity than the masseter muscle at all the evaluation times. LLLT caused significant immediate relaxation of the masseter muscles.