984 resultados para Cultivars - Narrow row spacing
Resumo:
Interest in the study of magnetic/non-magnetic multilayered structures took a giant leap since Grünberg and his group established that the interlayer exchange coupling (IEC) is a function of the non-magnetic spacer width. This interest was further fuelled by the discovery of the phenomenal Giant Magnetoresistance (GMR) effect. In fact, in 2007 Albert Fert and Peter Grünberg were awarded the Nobel Prize in Physics for their contribution to the discovery of GMR. GMR is the key property that is being used in the read-head of the present day computer hard drive as it requires a high sensitivity in the detection of magnetic field. The recent increase in demand for device miniaturization encouraged researchers to look for GMR in nanoscale multilayered structures. In this context, one dimensional(1-D) multilayerd nanowire structure has shown tremendous promise as a viable candidate for ultra sensitive read head sensors. In fact, the phenomenal giant magnetoresistance(GMR) effect, which is the novel feature of the currently used multilayered thin film, has already been observed in multilayered nanowire systems at ambient temperature. Geometrical confinement of the supper lattice along the 2-dimensions (2-D) to construct the 1-D multilayered nanowire prohibits the minimization of magnetic interaction- offering a rich variety of magnetic properties in nanowire that can be exploited for novel functionality. In addition, introduction of non-magnetic spacer between the magnetic layers presents additional advantage in controlling magnetic properties via tuning the interlayer magnetic interaction. Despite of a large volume of theoretical works devoted towards the understanding of GMR and IEC in super lattice structures, limited theoretical calculations are reported in 1-D multilayered systems. Thus to gauge their potential application in new generation magneto-electronic devices, in this thesis, I have discussed the usage of first principles density functional theory (DFT) in predicting the equilibrium structure, stability as well as electronic and magnetic properties of one dimensional multilayered nanowires. Particularly, I have focused on the electronic and magnetic properties of Fe/Pt multilayered nanowire structures and the role of non-magnetic Pt spacer in modulating the magnetic properties of the wire. It is found that the average magnetic moment per atom in the nanowire increases monotonically with an ~1/(N(Fe)) dependance, where N(Fe) is the number of iron layers in the nanowire. A simple model based upon the interfacial structure is given to explain the 1/(N(Fe)) trend in magnetic moment obtained from the first principle calculations. A new mechanism, based upon spin flip with in the layer and multistep electron transfer between the layers, is proposed to elucidate the enhancement of magnetic moment of Iron atom at the Platinum interface. The calculated IEC in the Fe/Pt multilayered nanowire is found to switch sign as the width of the non-magnetic spacer varies. The competition among short and long range direct exchange and the super exchange has been found to play a key role for the non-monotonous sign in IEC depending upon the width of the Platinum spacer layer. The calculated magnetoresistance from Julliere's model also exhibit similar switching behavior as that of IEC. The universality of the behavior of exchange coupling has also been looked into by introducing different non-magnetic spacers like Palladium, Copper, Silver, and Gold in between magnetic Iron layers. The nature of hybridization between Fe and other non-magnetic spacer is found to dictate the inter layer magnetic interaction. For example, in Fe/Pd nanowire the d-p hybridization in two spacer layer case favors anti-ferromagnetic (AFM) configuration over ferromagnetic (FM) configuration. However, the hybridization between half-filled Fe(d) and filled Cu(p) state in Fe/Cu nanowire favors FM coupling in the 2-spacer system.
Resumo:
Background This is the first ever evaluation of narrow band imaging (NBI), an innovative endoscopic imaging procedure, for the visualisation of pleural processes. Methods The pleural cavity was examined in 26 patients with pleural effusions using both white light and narrow band imaging during thoracoscopy under local anaesthesia. Results In the great majority of the patients narrow band imaging depicted the blood vessels more clearly than white light, but failed to reveal any differences in number, shape or size. Only in a single case with pleura thickened by chronic inflammation and metastatic spread of lung cancer did narrow band imaging show vessels that were not detectable under white light. Conclusion It is not yet possible to assess to what extent the evidence provided by NBI is superior to that achieved with white light. Further studies are required, particularly in the early stages of pleural processes.
Resumo:
OBJECTIVE: To compare image quality and radiation dose of thoracoabdominal computed tomography (CT) angiography at 80 and 100 kVp and to assess the feasibility of reducing contrast medium volume from 60 to 45 mL at 80 kVp. MATERIALS AND METHODS: This retrospective study had institutional review board approval; informed consent was waived. Seventy-five patients who had undergone thoracoabdominal 64-section multidetector-row CT angiography were divided into 3 groups of 25 patients each. Patients of groups A (tube voltage, 100 kVp) and B (tube voltage, 80 kVp) received 60 mL of contrast medium at 4 mL/s. Patients of group C (tube voltage, 80 kVp) received 45 mL of contrast medium at 3 mL/s. Mean aortoiliac attenuation, image noise, and contrast-to-noise ratio were assessed. The measurement of radiation dose was based on the volume CT dose index. Three independent readers assessed the diagnostic image quality. RESULTS: Mean aortoiliac attenuation for group B (621.1 +/- 90.5 HU) was significantly greater than for groups A and C (485.2 +/- 110.5 HU and 483.1 +/- 119.8 HU; respectively) (P < 0.001). Mean image noise was significantly higher for groups B and C than for group A (P < 0.05). The contrast-to-noise ratio did not significantly differ between the groups (group A, 35.0 +/- 13.8; group B, 31.7 +/- 10.1; group C, 27.3 +/- 11.5; P = 0.08). Mean volume CT dose index in groups B and C (5.2 +/- 0.4 mGy and 4.9 +/- 0.3 mGy, respectively) were reduced by 23.5% and 27.9%, respectively, compared with group A (6.8 +/- 0.8 mGy) (P < 0.001). The average overall diagnostic image quality for the 3 groups was graded as good or better. The score for group A was significantly higher than that for group C (P < 0.01), no difference was seen between group A and B (P = 0.92). CONCLUSIONS: Reduction of tube voltage from 100 to 80 kVp for thoracoabdominal CT angiography significantly reduces radiation dose without compromising image quality. Reduction of contrast medium volume to 45 mL at 80 kVp resulted in lower but still diagnostically acceptable image quality.
Resumo:
RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.
Resumo:
PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.
Resumo:
As part of the ESA-funded MELiSSA program, the suitability, the growth and the development of four bread wheat cultivars were investigated in hydroponic culture with the aim to incorporate such a cultivation system in an Environmental Control and Life Support System (ECLSS). Wheat plants can fulfill three major functions in space: (a) fixation of CO2 and production of O2, (b) production of grains for human nutrition and (c) production of cleaned water after condensation of the water vapor released from the plants by transpiration. Four spring wheat cultivars (Aletsch, Fiorina, Greina and CH Rubli) were grown hydroponically and compared with respect to growth and grain maturation properties. The height of the plants, the culture duration from germination to harvest, the quantity of water used, the number of fertile and non-fertile tillers as well as the quantity and quality of the grains harvested were considered. Mature grains could be harvested after around 160 days depending on the varieties. It became evident that the nutrient supply is crucial in this context and strongly affects leaf senescence and grain maturation. After a first experiment, the culture conditions were improved for the second experiment (stepwise decrease of EC after flowering, pH adjusted twice a week, less plants per m2) leading to a more favorable harvest (higher grain yield and harvest index). Considerably less green tillers without mature grains were present at harvest time in experiment 2 than in experiment 1. The harvest index for dry matter (including roots) ranged from 0.13 to 0.35 in experiment 1 and from 0.23 to 0.41 in experiment 2 with modified culture conditions. The thousand-grain weight for the four varieties ranged from 30.4 to 36.7 g in experiment 1 and from 33.2 to 39.1 g in experiment 2, while market samples were in the range of 39.4–46.9 g. Calcium levels in grains of the hydroponically grown wheat were similar to those from field-grown wheat, while potassium, magnesium, phosphorus, iron, zinc, copper, manganese and nickel levels tended to be higher in the grains of experimental plants. It remains a challenge for future experiments to further adapt the nutrient supply in order to improve senescence of vegetative plant parts, harvest index and the composition of bread wheat grains.
Resumo:
This paper gives a general overview of the challenges that arise in using narrow-band signals, such as GSM, for localisation based on the time properties of the signal. Specifically, synchronisation and retrieving of time information are addressed. We pursue two contributions, namely, analysis of achievable synchronisation precision and processing of narrowband signals that can enable localization down to a meter. Keywords-localization, narrow band signals, TOA, TDOA I.
Resumo:
Time-based localization techniques such as multilateration are favoured for positioning to wide-band signals. Applying the same techniques with narrow-band signals such as GSM is not so trivial. The process is challenged by the needs of synchronization accuracy and timestamp resolution both in the nanoseconds range. We propose approaches to deal with both challenges. On the one hand, we introduce a method to eliminate the negative effect of synchronization offset on time measurements. On the other hand, we propose timestamps with nanoseconds accuracy by using timing information from the signal processing chain. For a set of experiments, ranging from sub-urban to indoor environments, we show that our proposed approaches are able to improve the localization accuracy of TDOA approaches by several factors. We are even able to demonstrate errors as small as 10 meters for outdoor settings with narrow-band signals.
Resumo:
1944/1945 wurde in Cham-Hagendorn eine Wassermühle ausgegraben, die dank ihrer aussergewöhnlich guten Holzerhaltung seit langem einen prominenten Platz in der Forschung einnimmt. 2003 und 2004 konnte die Kantonsarchäologie Zug den Platz erneut archäologisch untersuchen. Dabei wurden nicht nur weitere Reste der Wassermühle, sondern auch Spuren älterer und jüngerer Anlagen geborgen: eine ältere und eine jüngere Schmiedewerkstatt (Horizont 1a/Horizont 3) sowie ein zweiphasiges Heiligtum (Horizonte 1a/1b). All diese Anlagen lassen sich nun in das in den neuen Grabungen erkannte stratigraphische Gerüst einhängen (s. Beil. 2). Dank der Holzerhaltung können die meisten Phasen dendrochronologisch datiert werden (s. Abb. 4.1/1a): Horizont 1a mit Schlagdaten zwischen 162(?)/173 und 200 n. Chr., Horizont 1b um 215/218 n. Chr. und Horizont 2 um 231 n. Chr. Ferner konnten in den neuen Grabungen Proben für mikromorphologische und archäobotanische Untersuchungen entnommen werden (Kap. 2.2; 3.11). In der vorliegenden Publikation werden der Befund und die Baustrukturen vorgelegt, (Kap. 2), desgleichen sämtliche stratifizierten Funde und eine umfassende Auswahl der 1944/1945 geborgenen Funde (Kap. 3). Dank anpassender Fragmente, sog. Passscherben, lassen sich diese zum Teil nachträglich in die Schichtenabfolge einbinden. Die mikromorphologischen und die archäobotanischen Untersuchungen (Kap. 2.2; 3.11) zeigen, dass der Fundplatz in römischer Zeit inmitten einer stark vom Wald und dem Fluss Lorze geprägten Landschaft lag. In unmittelbarer Nähe können weder eine Siedlung noch einzelne Wohnbauten gelegen haben. Die demnach nur gewerblich und sakral genutzten Anlagen standen an einem Bach, der vermutlich mit jenem Bach identisch ist, der noch heute das Groppenmoos entwässert und bei Cham-Hagendorn in die Lorze mündet (s. Abb. 2.4/1). Der antike Bach führte wiederholt Hochwasser ─ insgesamt sind fünf grössere Überschwemmungsphasen auszumachen (Kap. 2.2; 2.4). Wohl anlässlich eines Seehochstandes durch ein Überschwappen der Lorze in den Bach ausgelöst, müssen diese Überschwemmungen eine enorme Gewalt entwickelt haben, der die einzelnen Anlagen zum Opfer fielen. Wie die Untersuchung der Siedlungslandschaft römischer Zeit rund um den Zugersee wahrscheinlich macht (Kap. 6 mit Abb. 6.2/2), dürften die Anlagen von Cham-Hagendorn zu einer in Cham-Heiligkreuz vermuteten Villa gehören, einem von fünf grösseren Landgütern in diesem Gebiet. Hinweise auf Vorgängeranlagen fehlen, mit denen die vereinzelten Funde des 1. Jh. n. Chr. (Kap. 4.5) in Verbindung gebracht werden könnten. Diese dürften eher von einer der Überschwemmungen bachaufwärts weggerissen und nach Cham-Hagendorn eingeschwemmt worden sein. Die Nutzung des Fundplatzes (Horizont 1a; s. Beil. 6) setzte um 170 n. Chr. mit einer Schmiedewerkstatt ein (Kap. 2.5.1). Der Fundanfall, insbesondere die Schmiedeschlacken (Kap. 3.9) belegen, dass hier nur hin und wieder Geräte hergestellt und repariert wurden (Kap. 5.2). Diese Werkstatt war vermutlich schon aufgelassen und dem Verfall preisgegeben, als man 200 n. Chr. (Kap. 4.2.4) auf einer Insel zwischen dem Bach und einem Lorzearm ein Heiligtum errichtete (Kap. 5.3). Beleg für den sakralen Status dieser Insel ist in erster Linie mindestens ein eigens gepflanzter Pfirsichbaum, nachgewiesen mit Pollen, einem Holz und über 400 Pfirsichsteinen (Kap. 3.11). Die im Bach verlaufende Grenze zwischen dem sakralen Platz und der profanen Umgebung markierte man zusätzlich mit einer Pfahlreihe (Kap. 2.5.3). In diese war ein schmaler Langbau integriert (Kap. 2.5.2), der an die oft an Temenosmauern antiker Heiligtümer angebauten Portiken erinnert und wohl auch die gleiche Funktion wie diese gehabt hatte, nämlich das Aufbewahren von Weihegaben und Kultgerät (Kap. 5.3). Das reiche Fundmaterial, das sich in den Schichten der ersten Überschwemmung fand (s. Abb. 5./5), die um 205/210 n. Chr. dieses Heiligtum zerstört hatte, insbesondere die zahlreiche Keramik (Kap. 3.2.4), und die zum Teil auffallend wertvollen Kleinfunde (Kap. 3.3.3), dürften zum grössten Teil einst in diesem Langbau untergebracht gewesen sein. Ein als Glockenklöppel interpretiertes, stratifiziertes Objekt spricht dafür, dass die fünf grossen, 1944/1945 als Stapel aufgefundenen Eisenglocken vielleicht auch dem Heiligtum zuzuweisen sind (Kap. 3.4). In diesen Kontext passen zudem die überdurchschnittlich häufig kalzinierten Tierknochen (Kap. 3.10). Nach der Überschwemmung befestigte man für 215 n. Chr. (Kap. 4.2.4) das unterspülte Bachufer mit einer Uferverbauung (Kap. 2.6.1). Mit dem Bau eines weiteren, im Bach stehenden Langbaus (Kap. 2.6.2) stellte man 218 n. Chr. das Heiligtum auf der Insel in ähnlicher Form wieder her (Horizont 1b; s. Beil. 7). Von der Pfahlreihe, die wiederum die sakrale Insel von der profanen Umgebung abgrenzte, blieben indes nur wenige Pfähle erhalten. Dennoch ist der sakrale Charakter der Anlage gesichert. Ausser dem immer noch blühenden Pfirsichbaum ist es ein vor dem Langbau aufgestelltes Ensemble von mindestens 23 Terrakottafigurinen (s. Abb. 3.6/1), elf Veneres, zehn Matres, einem Jugendlichen in Kapuzenmantel und einem kindlichen Risus (Kap. 3.6; s. auch Kap. 2.6.3). In den Sedimenten der zweiten Überschwemmung, der diese Anlage um 225/230 n. Chr. zum Opfer gefallen war, fanden sich wiederum zahlreiche Keramikgefässe (Kap. 3.2.4) und zum Teil wertvolle Kleinfunde wie eine Glasperle mit Goldfolie (Kap. 3.8.2) und eine Fibel aus Silber (Kap. 3.3.3), die wohl ursprünglich im Langbau untergebracht waren (Kap. 5.3.2 mit Abb. 5/7). Weitere Funde mit sicherem oder möglichem sakralem Charakter finden sich unter den 1944/1945 geborgenen Funden (s. Abb. 5/8), etwa ein silberner Fingerring mit Merkurinschrift, ein silberner Lunula-Anhänger, eine silberne Kasserolle (Kap. 3.3.3), eine Glasflasche mit Schlangenfadenauflage (Kap. 3.8.2) und einige Bergkristalle (Kap. 3.8.4). Im Bereich der Terrakotten kamen ferner mehrere Münzen (Kap. 3.7) zum Vorschein, die vielleicht dort niedergelegt worden waren. Nach der zweiten Überschwemmung errichtete man um 231 n. Chr. am Bach eine Wassermühle (Horizont 2; Kap. 2.7; Beil. 8; Abb. 2.7/49). Ob das Heiligtum auf der Insel wieder aufgebaut oder aufgelassen wurde, muss mangels Hinweisen offen bleiben. Für den abgehobenen Zuflusskanal der Wassermühle verwendete man mehrere stehen gebliebene Pfähle der vorangegangenen Anlagen der Horizonte 1a und 1b. Obwohl die Wassermühle den 28 jährlichen Überschwemmungshorizonten (Kap. 2.2) und den Funden (Kap. 4.3.2; 4.4.4; 45) zufolge nur bis um 260 n. Chr., während gut einer Generation, bestand, musste sie mindestens zweimal erneuert werden – nachgewiesen sind drei Wasserräder, drei Mühlsteinpaare und vermutlich drei Podeste, auf denen jeweils das Mahlwerk ruhte. Grund für diese Umbauten war wohl der weiche, instabile Untergrund, der zu Verschiebungen geführt hatte, so dass das Zusammenspiel von Wellbaum bzw. Sternnabe und Übersetzungsrad nicht mehr funktionierte und das ganze System zerbrach. Die Analyse von Pollen aus dem Gehhorizont hat als Mahlgut Getreide vom Weizentyp nachgewiesen (Kap. 3.11.4). Das Abzeichen eines Benefiziariers (Kap. 3.3.2 mit Abb. 3.3/23,B71) könnte dafür sprechen, dass das verarbeitete Getreide zumindest zum Teil für das römische Militär bestimmt war (s. auch Kap. 6.2.3). Ein im Horizont 2 gefundener Schreibgriffel und weitere stili sowie eine Waage für das Wägen bis zu 35-40 kg schweren Waren aus dem Fundbestand von 1944/1945 könnten davon zeugen, dass das Getreide zu wägen und zu registrieren war (Kap. 3.4.2). Kurz nach 260 n. Chr. fiel die Wassermühle einem weiteren Hochwasser zum Opfer. Für den folgenden Horizont 3 (Beil. 9) brachte man einen Kiesboden ein und errichtete ein kleines Gebäude (Kap. 2.8). Hier war wohl wiederum eine Schmiede untergebracht, wie die zahlreichen Kalottenschlacken belegen (Kap. 3.9), die im Umfeld der kleinen Baus zum Vorschein kamen. Aufgrund der Funde (Kap. 4.4.4; 4.5) kann diese Werkstatt nur kurze Zeit bestanden haben, höchstens bis um 270 n. Chr., bevor sie einem weiteren Hochwasser zum Opfer fiel. Von der jüngsten Anlage, die wohl noch in römische Zeit datiert (Horizont 4; Beil. 10), war lediglich eine Konstruktion aus grossen Steinplatten zu fassen (Kap. 2.9.1). Wozu sie diente, muss offen bleiben. Auch der geringe Fundanfall spricht dafür, dass die Nutzung des Platzes, zumindest für die römische Zeit, allmählich ein Ende fand (Kap. 4.5). Zu den jüngsten Strukturen gehören mehrere Gruben (Kap. 2.9.2), die vielleicht der Lehmentnahme dienten. Mangels Funden bleibt ihre Datierung indes ungewiss. Insbesondere wissen wir nicht, ob sie noch in römische Zeit datieren oder jünger sind. Spätestens mit der fünften Überschwemmung, die zur endgültigen Verlandung führte und wohl schon in die frühe Neuzeit zu setzen ist, wurde der Platz aufgelassen und erst mit dem Bau der bestehenden Fensterfabrik Baumgartner wieder besetzt.
Resumo:
Time-based indoor localization has been investigated for several years but the accuracy of existing solutions is limited by several factors, e.g., imperfect synchronization, signal bandwidth and indoor environment. In this paper, we compare two time-based localization algorithms for narrow-band signals, i.e., multilateration and fingerprinting. First, we develop a new Linear Least Square (LLS) algorithm for Differential Time Difference Of Arrival (DTDOA). Second, fingerprinting is among the most successful approaches used for indoor localization and typically relies on the collection of measurements on signal strength over the area of interest. We propose an alternative by constructing fingerprints of fine-grained time information of the radio signal. We offer comprehensive analytical discussions on the feasibility of the approaches, which are backed up by evaluations in a software defined radio based IEEE 802.15.4 testbed. Our work contributes to research on localization with narrow-band signals. The results show that our proposed DTDOA-based LLS algorithm obviously improves the localization accuracy compared to traditional TDOA-based LLS algorithm but the accuracy is still limited because of the complex indoor environment. Furthermore, we show that time-based fingerprinting is a promising alternative to power-based fingerprinting.
Resumo:
Single gold particles may serve as room temperature single electron memory units because of their size dependent electronic level spacing. Here, we present a proof-of-concept study by electrochemically controlled scanning probe experiments performed on tailor-made Au particles of narrow dispersity. In particular, the charge transport characteristics through chemically synthesized hexane-1-thiol and 4-pyridylbenzene-1-thiol mixed monolayer protected Au144 clusters (MPCs) by differential pulse voltammetry (DPV) and electrochemical scanning tunneling spectroscopy (EC-STS) are reported. The pyridyl groups exposed by the Au-MPCs enable their immobilization on Pt(111) substrates. By varying the humidity during their deposition, samples coated by stacks of compact monolayers of Au-MPCs or decorated with individual, laterally separated Au-MPCs are obtained. DPV experiments with stacked monolayers of Au144-MPCs and EC-STS experiments with laterally separated individual Au144-MPCs are performed both in aqueous and ionic liquid electrolytes. Lower capacitance values were observed for individual clusters compared to ensemble clusters. This trend remains the same irrespective of the composition of the electrolyte surrounding the Au144-MPC. However, the resolution of the energy level spacing of the single clusters is strongly affected by the proximity of neighboring particles.