876 resultados para Cubed-Sphere Grid
Resumo:
This paper focuses on a problem of Grid system decomposition by developing its object model. Unified Modelling Language (UML) is used as a formalization tool. This approach is motivated by the complexity of the system being analysed and the need for simulation model design.
Resumo:
This paper presents research from part of a larger project focusing on the potential development of commercial opportunities for the reuse of batteries on the electricity grid system, subsequent to their primary use in low and ultra-low carbon vehicles, and investigating the life cycle issues surrounding the batteries. The work has three main areas; examination of electric vehicle fleet data in detail to investigate usage in first life. Batteries that have passed through a battery recycler at the end of their first life have been tested within the laboratory to confirm the general assumption that remaining capacity of 80% after use in transportation is a reasonable assumption as a basis for second-life applications. The third aspect of the paper is an investigation of the equivalent usage for three different second-life applications based on connection to the electricity grid. Additionally, the paper estimates the time to cell failure of the batteries within their second-life application to estimate lifespan for use within commercial investigations. © 2014 IEEE.
Resumo:
This work is part of a bigger project which aims to research the potential development of commercial opportunities for the re-use of batteries after their use in low carbon vehicles on an electricity grid or microgrid system. There are three main revenue streams (peak load lopping on the distribution Network to allow for network re-enforcement deferral, National Grid primary/ secondary/ high frequency response, customer energy management optimization). These incomes streams are dependent on the grid system being present. However, there is additional opportunity to be gained from also using these batteries to provide UPS backup when the grid is no longer present. Most UPS or ESS on the market use new batteries in conjunction with a two level converter interface. This produces a reliable backup solution in the case of loss of mains power, but may be expensive to implement. This paper introduces a modular multilevel cascade converter (MMCC) based ESS using second-life batteries for use on a grid independent industrial plant without any additional onsite generator as a potentially cheaper alternative. The number of modules has been designed for a given reliability target and these modules could be used to minimize/eliminate the output filter. An appropriate strategy to provide voltage and frequency control in a grid independent system is described and simulated under different disturbance conditions such as load switching, fault conditions or a large motor starting. A comparison of the results from the modular topology against a traditional two level converter is provided to prove similar performance criteria. The proposed ESS and control strategy is an acceptable way of providing backup power in the event of loss of grid. Additional financial benefit to the customer may be obtained by using a second life battery in this way.
Resumo:
This paper is part of a project which aims to research the opportunities for the re-use of batteries after their primary use in low and ultra low carbon vehicles on the electricity grid system. One potential revenue stream is to provide primary/secondary/high frequency response to National Grid through market mechanisms via DNO's or Energy service providers. Some commercial battery energy storage systems (BESS) already exist on the grid system, but these tend to use costly new or high performance batteries. Second life batteries should be available at lower cost than new batteries but reliability becomes an important issue as individual batteries may suffer from degraded performance or failure. Therefore converter topology design could be used to influence the overall system reliability. A detailed reliability calculation of different single phase battery-to-grid converter interfacing schemes is presented. A suitable converter topology for robust and reliable BESS is recommended.
Resumo:
Smart grid technologies have given rise to a liberalised and decentralised electricity market, enabling energy providers and retailers to have a better understanding of the demand side and its response to pricing signals. This paper puts forward a reinforcement-learning-powered tool aiding an electricity retailer to define the tariff prices it offers, in a bid to optimise its retail strategy. In a competitive market, an energy retailer aims to simultaneously increase the number of contracted customers and its profit margin. We have abstracted the problem of deciding on a tariff price as faced by a retailer, as a semi-Markov decision problem (SMDP). A hierarchical reinforcement learning approach, MaxQ value function decomposition, is applied to solve the SMDP through interactions with the market. To evaluate our trading strategy, we developed a retailer agent (termed AstonTAC) that uses the proposed SMDP framework to act in an open multi-agent simulation environment, the Power Trading Agent Competition (Power TAC). An evaluation and analysis of the 2013 Power TAC finals show that AstonTAC successfully selects sell prices that attract as many customers as necessary to maximise the profit margin. Moreover, during the competition, AstonTAC was the only retailer agent performing well across all retail market settings.
Resumo:
The software architecture and development consideration for open metadata extraction and processing framework are outlined. Special attention is paid to the aspects of reliability and fault tolerance. Grid infrastructure is shown as useful backend for general-purpose task.
Resumo:
In this paper conceptual foundations for the development of Grid systems that aimed for satellite data processing are discussed. The state of the art of development of such Grid systems is analyzed, and a model of Grid system for satellite data processing is proposed. An experience obtained within the development of the Grid system for satellite data processing in the Space Research Institute of NASU-NSAU is discussed.
Resumo:
Implementation of GEOSS/GMES initiative requires creation and integration of service providers, most of which provide geospatial data output from Grid system to interactive user. In this paper approaches of DOS- centers (service providers) integration used in Ukrainian segment of GEOSS/GMES will be considered and template solutions for geospatial data visualization subsystems will be suggested. Developed patterns are implemented in DOS center of Space Research Institute of National Academy of Science of Ukraine and National Space Agency of Ukraine (NASU-NSAU).
Resumo:
We define Picard cycles on each smooth three-sheeted Galois cover C of the Riemann sphere. The moduli space of all these algebraic curves is a nice Shimura surface, namely a symmetric quotient of the projective plane uniformized by the complex two-dimensional unit ball. We show that all Picard cycles on C form a simple orbit of the Picard modular group of Eisenstein numbers. The proof uses a special surface classification in connection with the uniformization of a classical Picard-Fuchs system. It yields an explicit symplectic representation of the braid groups (coloured or not) of four strings.
Resumo:
* The work is partially supported by the grant of National Academy of Science of Ukraine for the support of scientific researches by young scientists No 24-7/05, " Розробка Desktop Grid-системи і оптимізація її продуктивності ”.
Resumo:
The authors present the impact of asymmetric filtering of strong (e.g. 35 GHz) optical filters on the performance of 42.7 Gb/s 67% (carrier suppressed return to zero)-differential phase shift keying systems. The performance is examined (in an amplified spontaneous emission (ASE) noise-limited regime and in the presence of chromatic dispersion) when offsetting the filter at the receiver by substantial amounts via balanced, constructive and destructive single-ended detections. It is found that with a slight offset (vestigial side band) or an offset of almost half of the modulation frequency (single-side band), there is a significant improvement in the calculated 'Q'. © The Institution of Engineering and Technology 2013.
Resumo:
This paper highlights the challenges of satellite monitoring systems integration, in particular based on Grid platform, and reviews possible solutions for these problems. We describe integration issues on different levels: data integration level and task management level (job submission in terms of Grid). We show example of described technologies for integration of monitoring systems of Ukraine (National Space Agency of Ukraine, NASU) and Russia (Space Research Institute RAS, IKI RAN). Another example refers to the development of InterGrid infrastructure that integrates several regional and national Grid systems: Ukrainian Academician Grid (with Satellite data processing Grid segment) and RSGS Grid (Chinese Academy of Sciences).
Resumo:
Methodological, theoretical and technological bases of the new branch standard of Ukraine higher education which regulates preparation process of masters - professionals in the information area and information analysts are considered. The new systemological knowledge-oriented technologies developed in KNURE which considerably surpass foreign analogues are put as the basis of training.
Resumo:
Communication between power converters is vital for high performance DC micro-grids controls. However, for residential DC micro-grid applications, using external communication link would increase the system cost, and reduce the system flexibility and reliability. This paper presents a novel method to enable the conventional DC/DC converters to transmit data via the common DC Bus. With this technology, cost-effective low bandwidth communication links between power converters can be established within a DC micro-grid, and advanced distributed control algorithms can be developed. A reliable communication with 2 kbps transmission rate has been implemented between the Boost converters through the common input DC bus.