974 resultados para Chorionic arteries
Resumo:
Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.
Resumo:
BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
Resumo:
Changes in vascular structure that accompany hypertension may contribute to hypertensive end-organ damage. Both the macrovascular and microvascular levels should be considered, as interactions between them are believed to be critically important. Regarding the macrocirculation, the article first reviews basic concepts of vascular biomechanics, such as arterial compliance, arterial distensibility, and stress-strain relationships of arterial wall material, and then reviews how hypertension affects the properties of conduit arteries, particularly examining evidence that it accelerates the progressive stiffening that normally occurs with advancing age. High arterial stiffness may increase central systolic and pulse pressure by two different mechanisms: 1) Abnormally high pulse wave velocity may cause pressure waves reflected in the periphery to reach the central aorta in systole, thus augmenting systolic pressure; 2) In the elderly, the interaction of the forward pressure wave with high arterial stiffness is mostly responsible for abnormally high pulse pressure. At the microvascular level, hypertensive disease is characterized by inward eutrophic or hypertrophic arteriolar remodeling and capillary rarefaction. These abnormalities may depend in part on the abnormal transmission of highly pulsatile blood pressure into microvascular networks, especially in highly perfused organs with low vascular resistance, such as the kidney, heart, and brain, where it contributes to hypertensive end-organ damage.
Resumo:
AIM: Fabry disease is considered primarily as a progressive small vessel disease, with ischaemic degenerative lesions involving the kidneys, brain and heart. Macrovascular involvement in male patients includes an accelerated wall hypertrophy of the radial artery and a thickening of the intima-media of the common carotid artery. The aim of this study is to evaluate the prevalence and severity of carotid artery atherosclerosis in hemizygous and heterozygous patients with Fabry disease, compared with a matched control population. METHODS: The common carotid artery intima-media thickness (IMT) of 53 patients with Fabry disease (24 men, 29 women) was measured by high-definition ultrasonography, and the presence or absence of atherosclerotic plaques reported. Results were compared with those of 120 age-matched healthy individuals (83 men, 37 women). RESULTS: The common carotid artery IMT was increased to the same extent in male and female patients with Fabry disease (706+/-211 microm and 749+/-395 microm, respectively) compared with that of the control population (614+/-113 microm). In the Fabry population, IMT did not correlate with either systolic blood pressure or with renal function (plasma creatinine). In the control population, only systolic blood pressure was positively and significantly correlated with IMT. Atherosclerotic plaques in the common carotid artery were not observed in any patient with Fabry disease, whereas 34% of the control population had carotid artery plaques, as evidenced by focal non-homogeneous intima-media thickening greater than 1.2 mm. CONCLUSION: This study presents evidence of a major increase in common carotid artery IMT, both in hemizygous and heterozygous patients with Fabry disease, in the absence of focal atherosclerotic plaques. These results suggest that the conduit arteries may be protected from atherosclerosis in Fabry disease.
Resumo:
BACKGROUND: Few studies have examined plaque characteristics among multiple arterial beds in vivo. The purpose of this study was to compare the plaque morphology and arterial remodeling between coronary and peripheral arteries using gray-scale and radiofrequency intravascular ultrasound (IVUS) at clinical presentation. METHODS AND RESULTS: IVUS imaging was performed in 68 patients with coronary and 93 with peripheral artery lesions (29 carotid, 50 renal, and 14 iliac arteries). Plaques were classified as fibroatheroma (VH-FA) (further subclassified as thin-capped [VH-TCFA] and thick-capped [VH-ThCFA]), fibrocalcific plaque (VH-FC) and pathological intimal thickening (VH-PIT). Plaque rupture (13% of coronary, 7% of carotid, 6% of renal, and 7% of iliac arteries; P = NS) and VH-TCFA (37% of coronary, 24% of carotid, 16% of renal, and 7% of iliac arteries; P = 0.02) were observed in all arteries. Compared with coronary arteries, VH-FA was less frequently observed in renal (P < 0.001) and iliac arteries (P < 0.006). Lesions with positive remodeling demonstrated more characteristics of VH-FA in coronary (84% vs. 25%, P < 0.001), carotid (72% vs. 20%, P = 0.001), and renal arteries (42% vs. 4%, P = 0.001) compared with those with intermediate/negative remodeling. There was positive relationship between remodeling index and percent necrotic area in all four arteries. CONCLUSIONS: Atherosclerotic plaque phenotypes were heterogeneous among four different arteries; renal and iliac arteries had more stable phenotypes compared with coronary artery. In contrast, the associations of remodeling pattern with plaque phenotype and composition were similar among the various arterial beds.
Resumo:
A new high-precision ultrasonic device was developed to determine noninvasively arterial compliance as a function of blood pressure. Because of the nonlinear elastic properties of arterial walls, measurements of compliance can be appropriately compared only if obtained over a range of pressures. This apparatus was used to evaluate in a double-blind, parallel fashion the effect of three different antihypertensive drugs and of a placebo on radial artery compliance. Thirty-two normotensive volunteers were randomly allocated to an 8-day, once-a-day oral treatment with either a placebo, 100 mg atenolol, 20 mg nitrendipine, or 20 mg lisinopril. Blood pressure, heart rate, radial artery diameter, and arterial compliance were measured immediately before as well as 6 hours after dosing on the first and last days of the study. On the eighth day of administration, within 6 hours after dosing, lisinopril induced an acute increase in radial artery diameter, from 2.99 +/- 0.06 to 3.28 +/- 0.09 mm (mean +/- SEM, p less than 0.01). The compliance-pressure curve was shifted upward on day 1 (p less than 0.01) as well as on day 8 (p less than 0.05). None of the other drugs induced any significant modification of these parameters. Arterial compliance has a strong nonlinear dependency on intra-arterial pressure and therefore has to be defined as a function of pressure. Antihypertensive drugs acting by different mechanisms may have different effects on the mechanical properties of large arteries.
Resumo:
BACKGROUND: Giant cell arteritis (GCA) is a systemic segmental vasculitis of unknown etiology, typically affecting elderly patients. Elevated erythrocyte-sedimentation rate (ESR) is usually found in such patients. PATIENTS AND METHODS: One hundred and twenty three patients underwent temporal artery biopsy in our institution between 1977 and 1995. Among them, 66 (53.7%) biopsies were positive (i.e. histologic findings were very suggestive of GCA). The clinical charts from all patients with positive biopsies were retrieved and 47 were eligible for our study (inadequate data in 19 cases). RESULTS: Seven of the 47 patients with positive biopsies (15%) had a normal ESR and 70% (33/47 cases) had neuro-ophthalmic complications including anterior ischemic optic neuropathy, central retinal artery occlusion, choroidal ischemia and extraocular muscle and/or cranial nerve palsy (III, IV, VI). No differences were found between the groups with normal or elevated ESR as 87.5% (6/7 cases) of the group with normal ESR exhibited neuro-ophthalmic complications. CONCLUSIONS: ESR was normal in 15% of our GCA patients and these patients had the same frequency of neuro-ophthalmic complications as the GCA patients with elevated ESR. Thus, our study does not support the previous concept that patients with higher ESR are more at risk for neuro-ophthalmic complications. GCA with normal ESR is not rare and such patients should be investigated with other blood studies (C-reactive protein) and with fluorescein angiography.
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Resumo:
Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.
Resumo:
Three-dimensional free-breathing coronary magnetic resonance angiography was performed in eight healthy volunteers with use of real-time navigator technology. Images acquired with the navigator localized at the right hemidiaphragm and at the left ventricle were objectively compared. The diaphragmatic navigator was found to be superior for vessel delineation of middle to distal portions of the coronary arteries.
Resumo:
The case of a professional tennis player presenting exercise-induced hand pain with late appearance of digital blanching is reported. A bilateral hypothenar hammer syndrome and stenosis of the common palmar digital arteries close to the head of the metacarpals where the racket handle exerts its maximal force was observed with arteriography. As the patient decided to stop tennis practice, the condition improved without any medication. Six months after stopping tennis he was symptom free. Three conclusions can be drawn from this case report: 1) arteries of both hands can be injured by intense tennis practice, 2) pain in the dominant hand during tennis practice can be due to arterial insufficiency even in the absence of digital blanching which is a sign of severity, 3) hypothenar hammer syndrome is the main cause but stenosis of the common palmar digital arteries can possibly contribute to the ischemic phenomenon. Early recognition is important to avoid ineffective treatment and permanent symptoms. Therefore, we recommend an arterial examination in tennis players suffering from exercise-induced hand pain even in the absence of digital blanching which can be only a late manifestation.
Resumo:
The mechanisms of blood vessel maturation into distinct parts of the blood vasculature such as arteries, veins, and capillaries have been the subject of intense investigation over recent years. In contrast, our knowledge of lymphatic vessel maturation is still fragmentary. In this study, we provide a molecular and morphological characterization of the major steps in the maturation of the primary lymphatic capillary plexus into collecting lymphatic vessels during development and show that forkhead transcription factor Foxc2 controls this process. We further identify transcription factor NFATc1 as a novel regulator of lymphatic development and describe a previously unsuspected link between NFATc1 and Foxc2 in the regulation of lymphatic maturation. We also provide a genome-wide map of FOXC2-binding sites in lymphatic endothelial cells, identify a novel consensus FOXC2 sequence, and show that NFATc1 physically interacts with FOXC2-binding enhancers. These data provide novel insights into the molecular program of lymphatic vascular specification and suggest that FOXC2 and NFATc1 are potential targets for therapeutic intervention.
Resumo:
Two-dimensional (2D)-breath-hold coronary magnetic resonance angiography (MRA) has been shown to be a fast and reliable method to depict the proximal coronary arteries. Recent developments, however, allow for free-breathing navigator gated and navigator corrected three-dimensional (3D) coronary MRA. These 3D approaches have potential for improved signal-to-noise ratio (SNR) and allow for the acquisition of adjacent thin slices without the misregistration problems known from 2D approaches. Still, a major impediment of a 3D acquisition is the increased scan time. The purpose of this study was the implementation of a free-breathing navigator gated and corrected ultra-fast 3D coronary MRA technique, which allows for scan times of less than 5 minutes. Twelve healthy adult subjects were examined in the supine position using a navigator gated and corrected ECG triggered ultra-fast 3D interleaved gradient echo planar imaging sequence (TFE-EPI). A 3D slab, consisting of 20 slices with a reconstructed slice thickness of 1.5 mm, was acquired with free-breathing. The diastolic TFE-EPI acquisition block was preceded by a T2prep pre-pulse, a diaphragmatic navigator pulse, and a fat suppression pre-pulse. With a TR of 19 ms and an effective TE of 5.4 ms, the duration of the data acquisition window duration was 38 ms. The in-plane spatial resolution was 1.0-1.3 mm*1.5-1.9 mm. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and right coronary artery (RCA) could be visualized with an average scan time for the entire 3D-volume data set of 2:57 +/- 0:51 minutes. Average contiguous vessel length visualized was 53 +/- 11 mm (range: 42 to 75 mm) for the LAD and 84 +/- 14 mm (range: 62 to 112 mm) for the RCA. Contrast-to-noise between coronary blood and myocardium was 5.0 +/- 2.3 for the LM/LAD and 8.0 +/- 2.9 for the RCA, resulting in an excellent suppression of myocardium. We present a new approach for free-breathing 3D coronary MRA, which allows for scan times superior to corresponding 2D coronary MRA approaches, and which takes advantage of the enhanced SNR of 3D acquisitions and the post-processing benefits of thin adjacent slices. The robust image quality and the short average scanning time suggest that this approach may be useful for screening the major coronary arteries or identification of anomalous coronary arteries. J. Magn. Reson. Imaging 1999;10:821-825.
Resumo:
Objective: To implement a carotid sparing protocol using helical Tomotherapy(HT) in T1N0 squamous-cell laryngeal carcinoma.Materials/Methods: Between July and August 2010, 7 men with stage T1N0 laryngeal carcinoma were included in this study. Age ranged from 47-74 years. Staging included endoscopic examination, CT-scan and MRI when indicated.Planned irradiation dose was 70 Gy in 35 fractions over 7 weeks. A simple treatment planning algorithm for carotidsparing was used: maximum point dose to the carotids 35 Gy, to the spinal cord 30 Gy, and 100% PTV volume to becovered with 95% of the prescribed dose. Carotid volume of interest extended to 1 cm above and below of the PTV.Doses to the carotid arteries, critical organs, and planned target volume (PTV) with our standard laryngealirradiation protocol was compared. Daily megavoltage scans were obtained before each fraction. When necessary, thePlanned Adaptive? software (TomoTherapy Inc., Madison, WI) was used to evaluate the need for a re-planning,which has never been indicated. Dose data were extracted using the VelocityAI software (Atlanta, GA), and datanormalization and dosevolume histogram (DVH) interpolation were realized using the Igor Pro software (Portland,OR).Results: A significant (p < 0.05) carotid dose sparing compared to our standard protocol with an average maximum point dose of 38.3 Gy (standard devaition [SD] 4.05 Gy), average mean dose of 18.59 Gy (SD 0.83 Gy) was achieved.In all patients, 95% of the carotid volume received less than 28.4 Gy (SD 0.98 Gy). The average maximum point doseto the spinal cord was 25.8 Gy (SD 3.24 Gy). PTV was fully covered with more than 95% of the prescribed dose forall patients with an average maximum point dose of 74.1 Gy and the absolute maximum dose in a single patient of75.2 Gy. To date, the clinical outcomes have been excellent. Three patients (42%) developed stage 1 mucositis that was conservatively managed, and all the patients presented a mild to moderate dysphonia. All adverse effectsresolved spontaneously in the month following the end of treatment. Early local control rate is 100% considering a 4-5months post treatment follow-up.Conclusions: HT allows a clinically significant decrease of carotid irradiation dose compared tostandard irradiation protocols with an acceptable spinal cord dose tradeoff. Moreover, this technique allows the PTV to be homogenously covered with a curative irradiation dose. Daily control imaging brings added security marginsespecially when working with high dose gradients. Further investigations and follow-up are underway to better evaluatethe late clinical outcomes especially the local control rate, late laryngeal and vascular toxicity, and expected potentialimpact on cerebrovascular events.
Resumo:
Myocardial infarction is almost always the consequence of a thrombotic obstruction of one or more coronary arteries. We report our experience with the first 24 cases of intracoronary thrombolysis for recanalization of obstructed coronary arteries. 19 cases were successful, 1 case was partially successful and in 4 instances no reopening was observed. The amount of streptokinase used was 206 000 +/- 107 000 units, and reperfusion was achieved after 37 +/- 27.5 minutes. Recanalization of the vessel was accompanied by cessation of precordial pain and partial or complete normalization of the electrocardiogram. In one case bypass surgery was necessary because of reocclusion. Left ventricular function improvement after thrombolysis was dependent on the time-lag between occlusion and recanalization. These observations confirm others' experience that intracoronary thrombolysis appears to have favorable effects in patients with evolving myocardial infarction.