885 resultados para Chest


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the case of a 55-year-old man who presented with parasternal swelling. The chest CT scan showed a large tumor of the chest wall infiltrating the subcutaneous tissue. To assume histologic diagnosis an open biopsy was performed. Between the myofibrils a coarse, white tumor with infiltrative growth was noted. Histopathologic examination revealed expanded atrophic skeletal muscle that was infiltrated by histiocytic cells. Numerous eosinophilic granulocytes and lymphocytes CD20 and CD3 positive could be detected and immunohistochemical staining was also positive for S-100 proteins and CD1a. Histologic findings were characteristic of Langerhans cell histiocytosis (LCH). To the best of our knowledge a LCH originating from the mediastinum in an adult as presented has not been previously described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spontaneous pneumothorax in children is an emergency. A rapid and structured treatment is necessary. Indicating clinical signs are dyspnoea with unilateral reduced breath sounds and hypersonic percussion note. Chest x-ray confirms diagnosis. CT scan shows detailed information's of pathological changes in lung tissue and offers important considerations for the therapy. Today video assisted thoracoscopic surgery (VATS) takes a central role in the treatment of spontaneous pneumothorax. Thoracoscopy completes diagnosis detecting the pathologies, which were missed in imaging procedures. Definitive surgical treatment is performed simultaneously in the same anaesthesia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Umbilical venous catheters allow rapid central access in neonates, but may be associated with various complications. We present a case of a newborn with pericardial effusion following umbilical venous catheterization. An extremely low birth weight infant was intubated for respiratory distress syndrome and had umbilical venous and arterial lines in place. Massive cardiomegaly was noted on the subsequent chest X-ray. Echocardiography revealed a large pericardial effusion without signs of tamponade. After removing the catheter, the effusion gradually resolved. While pericardial effusion is a well-known complication of percutaneous long central lines, only a few case reports have documented sudden cardiovascular compromise associated with umbilical venous catheters. Pericardial effusion may be asymptomatic and should be suspected in infants with central catheters and progressive cardiomegaly. The prompt removal of catheters and, if signs of cardiac tamponade are present, emergency pericardiocentesis may prove to be life-saving.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Bronchopulmonary sequestration is a lung malformation characterized by nonfunctioning lung tissue without primary communication with the tracheobronchial tree. Intrauterine complications such as mediastinal shift, pleural effusion or fetal hydrothorax can be present. We present the case of a newborn with bilateral intralobar pulmonary sequestration. METHODS: Prenatal ultrasonography in a primigravida at 20 weeks of gestation revealed echogenic masses in the right fetal hemithorax with mediastinal shift towards the left side. Serial ultrasound confirmed persistence of the lesion with otherwise appropriate fetal development. Delivery was uneventful and physical examination revealed an isolated intermittent tachypnea. Chest CT scan and CT angiography showed a bilateral intrathoracic lesion with arterial supply from the aorta. Baby lung function testing suggested possible multiple functional compartments. RESULTS: Right and left thoracotomy was performed at the age of 7 months. A bilateral intralobar sequestration with vascularisation from the aorta was resected. Pathological and histological examination of the resected tissue confirmed the surgical diagnosis. At the age of 24 months, the child was doing well without pulmonary complications. CONCLUSIONS: Bilateral pulmonary sequestration requires intensive prenatal and postnatal surveillance. Though given the fact of a bilateral pulmonary sequestration, postnatal outcome showed similar favourable characteristics to an unilateral presentation. Baby lung function testing could provide additional information for optimal postnatal management and timing of surgical intervention.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autonomous system applications are typically limited by the power supply operational lifetime when battery replacement is difficult or costly. A trade-off between battery size and battery life is usually calculated to determine the device capability and lifespan. As a result, energy harvesting research has gained importance as society searches for alternative energy sources for power generation. For instance, energy harvesting has been a proven alternative for powering solar-based calculators and self-winding wristwatches. Thus, the use of energy harvesting technology can make it possible to assist or replace batteries for portable, wearable, or surgically-implantable autonomous systems. Applications such as cardiac pacemakers or electrical stimulation applications can benefit from this approach since the number of surgeries for battery replacement can be reduced or eliminated. Research on energy scavenging from body motion has been investigated to evaluate the feasibility of powering wearable or implantable systems. Energy from walking has been previously extracted using generators placed on shoes, backpacks, and knee braces while producing power levels ranging from milliwatts to watts. The research presented in this paper examines the available power from walking and running at several body locations. The ankle, knee, hip, chest, wrist, elbow, upper arm, side of the head, and back of the head were the chosen target localizations. Joints were preferred since they experience the most drastic acceleration changes. For this, a motor-driven treadmill test was performed on 11 healthy individuals at several walking (1-4 mph) and running (2-5 mph) speeds. The treadmill test provided the acceleration magnitudes from the listed body locations. Power can be estimated from the treadmill evaluation since it is proportional to the acceleration and frequency of occurrence. Available power output from walking was determined to be greater than 1mW/cm³ for most body locations while being over 10mW/cm³ at the foot and ankle locations. Available power from running was found to be almost 10 times higher than that from walking. Most energy harvester topologies use linear generator approaches that are well suited to fixed-frequency vibrations with sub-millimeter amplitude oscillations. In contrast, body motion is characterized with a wide frequency spectrum and larger amplitudes. A generator prototype based on self-winding wristwatches is deemed to be appropriate for harvesting body motion since it is not limited to operate at fixed-frequencies or restricted displacements. Electromagnetic generation is typically favored because of its slightly higher power output per unit volume. Then, a nonharmonic oscillating rotational energy scavenger prototype is proposed to harness body motion. The electromagnetic generator follows the approach from small wind turbine designs that overcome the lack of a gearbox by using a larger number of coil and magnets arrangements. The device presented here is composed of a rotor with multiple-pole permanent magnets having an eccentric weight and a stator composed of stacked planar coils. The rotor oscillations induce a voltage on the planar coil due to the eccentric mass unbalance produced by body motion. A meso-scale prototype device was then built and evaluated for energy generation. The meso-scale casing and rotor were constructed on PMMA with the help of a CNC mill machine. Commercially available discrete magnets were encased in a 25mm rotor. Commercial copper-coated polyimide film was employed to manufacture the planar coils using MEMS fabrication processes. Jewel bearings were used to finalize the arrangement. The prototypes were also tested at the listed body locations. A meso-scale generator with a 2-layer coil was capable to extract up to 234 µW of power at the ankle while walking at 3mph with a 2cm³ prototype for a power density of 117 µW/cm³. This dissertation presents the analysis of available power from walking and running at different speeds and the development of an unobtrusive miniature energy harvesting generator for body motion. Power generation indicates the possibility of powering devices by extracting energy from body motion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Injuries of the recurrent laryngeal nerve with consecutive vocal cord paralysis is a typical complication in chest, esophageal, thyroideal, and neck surgery. Glottic insufficiency secondary to such a lesion can be treated by endolaryngeal vocal cord augmentation (injection laryngoplasty). Many different substances have been used, often showing complications or disadvantages. This study reports on the use of injectable polydimethylsiloxane (PDMS), with special regard to the long-term results. METHODS: In this prospective study, 21 patients with unilateral vocal cord paralysis underwent injection laryngoplasty using PDMS at a volume of 0.5-1.0 ml. Preoperatively, 6 weeks and 12 months after the injection the following parameters concerning patients' voice were evaluated: Glottic closure by videolaryngostroboscopy, maximum phonation time, voice range, voice dynamic, jitter, shimmer, noise-to-harmonic-ratio, and roughness, breathiness, and hoarseness (RBH). In addition, patients were asked to give their own evaluation of how satisfied they felt with their voice and of the handicaps it caused them. RESULTS: Postoperatively an improvement was evident in all the parameters that were investigated, and this significant improvement was still in evidence for most of the parameters more than one year after the injection. In our study no complications were observed more than one year after injection. CONCLUSION: PDMS is a safe substance for injection laryngoplasty in unilateral vocal cord paresis. Objective and subjective parameters confirm its effectiveness. It is suitable for obtaining satisfying results in the reestablishment of the patient's voice and communication ability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 38-year-old homeless man was admitted with a 2-week history of a sore throat, increasing shortness of breath, and high fever. Clinical examination showed enlarged and tender submandibular and anterior cervical lymph nodes and a pronounced enlargement of the left peritonsillar region (Figure 1a). CT scan of the throat and the chest showed left peritonsillar abscess formation, occlusion of the left internal jugular vein with inflammatory wall thickening and perijugular soft tissue infiltration, pulmonary abscesses, and bilateral pleural effusions (Figures 1b-e, arrowed). Anaerobe blood cultures grew Fusobacterium necrophorum, leading to the diagnosis of Lemierre's syndrome. Treatment with high-dose amoxicillin and clavulanic acid improved the oropharyngeal condition, but the patient's general status declined further, marked by dyspnea and tachypnea. Repeated CT scans showed progressive lung abscesses and bilateral pleural empyema. Bilateral tonsillectomy, ligation of the left internal jugular vein, and staged decortication of bilateral empyema were performed. Total antibiotic therapy duration was 9 weeks, including a change to peroral clindamycin. Clinical and laboratory findings had returned to normal 12 weeks after surgery.The patient's history and the clinical and radiological findings are characteristic for Lemierre's syndrome. CT scans of the neck and the chest are the diagnostic methods of choice. F. necrophorum is found in over 80% of cases of Lemierre's syndrome and confirms the diagnosis. Prolonged antibiotic therapy is usually sufficient, but in selected patients, a surgical intervention may be necessary. Reported mortality rates are high, but in surviving patients, the recovery of pulmonary function is usually good.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Neurally adjusted ventilatory assist (NAVA) delivers assist in proportion to the patient's respiratory drive as reflected by the diaphragm electrical activity (EAdi). We examined to what extent NAVA can unload inspiratory muscles, and whether unloading is sustainable when implementing a NAVA level identified as adequate (NAVAal) during a titration procedure. METHODS: Fifteen adult, critically ill patients with a Pao(2)/fraction of inspired oxygen (Fio(2)) ratio < 300 mm Hg were studied. NAVAal was identified based on the change from a steep increase to a less steep increase in airway pressure (Paw) and tidal volume (Vt) in response to systematically increasing the NAVA level from low (NAVAlow) to high (NAVAhigh). NAVAal was implemented for 3 h. RESULTS: At NAVAal, the median esophageal pressure time product (PTPes) and EAdi values were reduced by 47% of NAVAlow (quartiles, 16 to 69% of NAVAlow) and 18% of NAVAlow (quartiles, 15 to 26% of NAVAlow), respectively. At NAVAhigh, PTPes and EAdi values were reduced by 74% of NAVAlow (quartiles, 56 to 86% of NAVAlow) and 36% of NAVAlow (quartiles, 21 to 51% of NAVAlow; p < or = 0.005 for all). Parameters during 3 h on NAVAal were not different from parameters during titration at NAVAal, and were as follows: Vt, 5.9 mL/kg predicted body weight (PBW) [quartiles, 5.4 to 7.2 mL/kg PBW]; respiratory rate (RR), 29 breaths/min (quartiles, 22 to 33 breaths/min); mean inspiratory Paw, 16 cm H(2)O (quartiles, 13 to 20 cm H(2)O); PTPes, 45% of NAVAlow (quartiles, 28 to 57% of NAVAlow); and EAdi, 76% of NAVAlow (quartiles, 63 to 89% of NAVAlow). Pao(2)/Fio(2) ratio, Paco(2), and cardiac performance during NAVAal were unchanged, while Paw and Vt were lower, and RR was higher when compared to conventional ventilation before implementing NAVAal. CONCLUSIONS: Systematically increasing the NAVA level reduces respiratory drive, unloads respiratory muscles, and offers a method to determine an assist level that results in sustained unloading, low Vt, and stable cardiopulmonary function when implemented for 3 h.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An 80-year-old nonsmoking man was referred to our hospital with bilateral perihilar pulmonary opacities. He had a history of epilepsy, sclerosing cholangitis, cutaneous lesions previously diagnosed as localised Langerhans cell histiocytosis. Symptoms included dry cough and dyspnea. Chest CT showed bilateral perihilar alveolar consolidation with bronchiectasis. Histological examination of a lung biopsy showed typical features of Langerhans cell granulomatosis. Investigations revealed anterior and posterior hypopituitarism. An important improvement occurred with corticosteroid and vinblastine treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study will look at the passenger air bag (PAB) performance in a fix vehicle environment using Partial Low Risk Deployment (PLRD) as a strategy. This development will follow test methods against actual baseline vehicle data and Federal Motor Vehicle Safety Standards 208 (FMVSS 208). FMVSS 208 states that PAB compliance in vehicle crash testing can be met using one of three deployment methods. The primary method suppresses PAB deployment, with the use of a seat weight sensor or occupant classification sensor (OCS), for three-year old and six-year old occupants including the presence of a child seat. A second method, PLRD allows deployment on all size occupants suppressing only for the presents of a child seat. A third method is Low Risk Deployment (LRD) which allows PAB deployment in all conditions, all statures including any/all child seats. This study outlines a PLRD development solution for achieving FMVSS 208 performance. The results of this study should provide an option for system implementation including opportunities for system efficiency and other considerations. The objective is to achieve performance levels similar too or incrementally better than the baseline vehicles National Crash Assessment Program (NCAP) Star rating. In addition, to define systemic flexibility where restraint features can be added or removed while improving occupant performance consistency to the baseline. A certified vehicles’ air bag system will typically remain in production until the vehicle platform is redesigned. The strategy to enable the PLRD hypothesis will be to first match the baseline out of position occupant performance (OOP) for the three and six-year old requirements. Second, improve the 35mph belted 5th percentile female NCAP star rating over the baseline vehicle. Third establish an equivalent FMVSS 208 certification for the 25mph unbelted 50th percentile male. FMVSS 208 high-speed requirement defines the federal minimum crash performance required for meeting frontal vehicle crash-test compliance. The intent of NCAP 5-Star rating is to provide the consumer with information about crash protection, beyond what is required by federal law. In this study, two vehicles segments were used for testing to compare and contrast to their baseline vehicles performance. Case Study 1 (CS1) used a cross over vehicle platform and Case Study 2 (CS2) used a small vehicle segment platform as their baselines. In each case study, the restraints systems were from different restraint supplier manufactures and each case contained that suppliers approach to PLRD. CS1 incorporated a downsized twins shaped bag, a carryover inflator, standard vents, and a strategic positioned bag diffuser to help disperse the flow of gas to improve OOP. The twin shaped bag with two segregated sections (lobes) to enabled high-speed baseline performance correlation on the HYGE Sled. CS2 used an A-Symmetric (square shape) PAB with standard size vents, including a passive vent, to obtain OOP similar to the baseline. The A-Symmetric shape bag also helped to enabled high-speed baseline performance improvements in HYGE Sled testing in CS2. The anticipated CS1 baseline vehicle-pulse-index (VPI) target was in the range of 65-67. However, actual dynamic vehicle (barrier) testing was overshadowed with the highest crash pulse from the previous tested vehicles with a VPI of 71. The result from the 35mph NCAP Barrier test was a solid 4-Star (4.7 Star) respectfully. In CS2, the vehicle HYGE Sled development VPI range, from the baseline was 61-62 respectively. Actual NCAP test produced a chest deflection result of 26mm versus the anticipated baseline target of 12mm. The initial assessment of this condition was thought to be due to the vehicles significant VPI increase to 67. A subsequent root cause investigation confirmed a data integrity issue due to the instrumentation. In an effort to establish a true vehicle test data point a second NCAP test was performed but faced similar instrumentation issues. As a result, the chest deflect hit the target of 12.1mm; however a femur load spike, similar to the baseline, now skewed the results. With noted level of performance improvement in chest deflection, the NCAP star was assessed as directional for 5-Star capable performance. With an actual rating of 3-Star due to instrumentation, using data extrapolation raised the ratings to 5-Star. In both cases, no structural changes were made to the surrogate vehicle and the results in each case matched their perspective baseline vehicle platforms. These results proved the PLRD is viable for further development and production implementation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of progressive, multifocal melorheostosis in a 28-year-old woman, with involvement of the left arm, chest, spine, and impressive soft tissue involvement. In the past, she had undergone multiple vascular interventions. She presented with spontaneous massive bilateral chylothorax. After conservative treatment without success, we conducted bilateral pleurodesis. This resulted in a clear reduction of pleural effusions, but her medical condition subsequently worsened due to progressive parenchymatous infiltrates, and increased interlobal pleural effusions. She ultimately died of global respiratory insufficiency. In patients with melorheostosis, involvement of the soft tissue can result in distinctive morbidity, and whenever possible, treatment should be conservative.