925 resultados para Cervical length


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eugenol is a phenylpropene obtained from the essential oils of plants such as clove and basil which has ample use in dentistry. Eugenol possesses analgesic effects that may be related to the inhibition of voltage-dependent Na(+) channels and/or to the activation of TRPV1 receptors or both. In the present study, electrophysiological parameters were taken from the compound action potentials of the isolated rat sciatic nerve and from neurons of the superior cervical ganglion (SCG) impaled with sharp microelectrodes under current-clamp conditions. In the isolated rat sciatic nerve, eugenol inhibited the compound action potential in a concentration-dependent manner. Action potentials recorded from SCG neurons were inhibited by eugenol with an IC(50) of 0.31 mM. At high concentrations (2 mM), during brief applications. eugenol caused significant action potential blockade while it did not interfere with the resting membrane potential or the membrane input resistance. Surprisingly, however, at low eugenol concentrations (0.6 mM), during long time applications, a reversible reduction (by about 50%) in the input membrane resistance was observed, suggesting the possible involvement of a secondary delayed effect of eugenol to reduce neuronal excitability. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In magnetic resonance imaging (MRI), either on human or animal studies, the main requirements for radiofrequency (RF) coils are to produce a homogeneous RF field while used as a transmitter coil and to have the best signal-to-noise ratio (SNR) while used as a receiver. Besides, they need to be easily frequency adjustable and have input impedance matching 50 Omega to several different load conditions. New theoretical and practical concepts are presented here for considerable enhancing of RF coil homogeneity for MRI experiments on small animals. To optimize field homogeneity, we have performed simulations using Blot and Savart law varying the coil`s window angle, achieving the optimum one. However, when the coil`s dimensions are the same order of the wave length and according to transmission line theory, differences in electrical length and effects of mutual inductances between adjacent strip conductors decrease both field homogeneity and SNR. The problematic interactions between strip conductors by means of mutual inductance were eliminated by inserting crossings at half electrical length, avoiding distortion on current density, thus eliminating sources of field inhomogeneity. Experimental results show that measured field maps and simulations are in good agreement. The new coil design, dubbed double-crossed saddle described here have field homogeneity and SNR superior than the linearly driven 8-rung birdcage coil. One of our major findings was that the effects of mutual inductance are more significant than differences in electrical length for this frequency and coil dimensions. In vitro images of a primate Cebus paela brain were acquired, confirming double-crossed saddle superiority. (C) 2010 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 37B: 193-201, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recovery and stability of DNA for the detection and genotyping of HPV in UCM-containing specimens, after exposure to denaturing reagents and stored for up to 2 years were evaluated. Samples were collected from 60 women who had cervical cytology specimens harboring cervical intraepithelial neoplasia (CIN) 2 or 3. All samples were stored in UCM and had been frozen at -20 degrees C following the addition of the denaturing reagent (sodium hydroxide) and the removal of the aliquot required for Hybrid Capture 2 testing for the identification of HPV DNA. The samples had been stored for 6, 12 and 24 months (20 samples for each storage time). HPV DNA extraction was performed according to a protocol designed specifically and the presence and quality of DNA was confirmed by human P-globin detection using the consensus primers G73 and G74. HPV DNA was amplified using the consensus primers PGMY09 and PGMY11, and reverse line-blot hybridization was used to detect type-specific amplicons for 37 HPV types. The DNA extracted from the denatured specimen was recovered in 57/60 (95%) of the samples. HPV DNA was detected in 56/57 (98%) of the recovered samples. Twenty-six of the 56 samples recovered (48%) were genotyped successfully. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Raman band assigned to the nu(C=O)mode in N,N-dimethylformamide (at ca. 1660 cm(-1)) was used as a probe to study a group of ionic liquids 1-alkyl-3-methylimidazolium bromide ([C(n)Mlm]Br) with different alkyl groups (n = 2, 4, 6, 8 and 10 carbons) in binary equimolar binary mixtures with dimethylformamide. Due to the high electric dipole moment of the group C=O, there is a substantial coupling between adjacent molecules in the solution, and the corresponding Raman band involves both vibrational and reorientational modes. Different chain lengths of the ILs lead to different extents of the uncoupling of adjacent molecules of dimethylformamide, resulting in different shifts for this band in the mixtures. Information about the organization of ionic liquids in solution was obtained and a model of aggregation for these systems is proposed. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several studies indicate that molecular variants of HPV-16 have different geographic distribution and risk associated with persistent infection and development of high-grade cervical lesions. In the present study, the frequency of HPV-16 variants was determined in 81 biopsies from women with cervical intraepithelial neoplasia grade III or invasive cervical cancer from the city of Belem, Northern Brazil. Host DNAs were also genotyped in order to analyze the ethnicity-related distribution of these variants. Ninie different HPV-16 LCR variants belonging to four phylogenetic branches were identified. Among these, two new isolates were characterized. The most prevalent HPV-16 variant detected was the Asian-American B-2,followed by the European B-12 and the European prototype. Infections by multiple variants were observed in both invasive cervical cancer and cervical intraepithelial neoplasia grade III cases. The analysis of a specific polymorphism within the E6 viral gene was performed in a subset of 76 isolates. The E6-350G polymorphism was significantly more frequent in Asian-American variants. The HPV-16 variability detected followed the same pattern of the genetic ancestry observed in Northern Brazil, with European, Amerindian and African roots. Although African ancestry was higher among women infected by the prototype, no correlation between ethnical origin and HPV-16 variants was found. These results corroborate previous data showing a high frequency of Asian-American variants in cervical neoplasia among women with multiethnic origin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi de avaliar in vitro a microinfiltração cervical imediata em restaurações ocluso-proximais de resina composta, onde foram utilizados dois sistemas adesivos (Scotchbond Multi Purpose - 3M; Clearfil Mega Bond - Kuraray) através de uma técnica de baixa intensidade de luz polimerizável. Em cada um dos 11 molares decíduos foram confeccionados dois preparos cavitários ocluso-proximais padronizados (um ocluso-mesial e outro ocluso-distal), com o auxílio de uma ponta diamantada cilíndrica de extremidade plana n°2094, (KG Sorensen), fixada a uma caneta de alta rotação sob refrigeração ar/água. Os sistemas adesivos foram aplicados seguindo as instruções do fabricante, um na cavidade ocluso-mesial e outro na ocluso distal, sendo inserida, posteriormente, uma resina composta híbrida (Z250 - 3M) pela técnica incremental LUTZ (1986). O primeiro incremento foi inserido na parede cervical da caixa proximal (sentido horizontal) e fotopolimerizado (fotopolimerizador VIPTM - Bisco) a uma intensidade de 100 mW/cm2 por 60 segundos. Dois outros incrementos foram inseridos diagonalmente na porção vestibular e lingual/palatina, a uma intensidade de 200 mW/cm2, também pelo tempo de 60 segundos. As restaurações foram submetidas a acabamento e polimento com o auxílio de um bisturi lâmina n°12 e com discos Sof-lex Pop-on (3M). Após o acabamento, foi realizada a impermeabilização, em seguida os dentes foram imersos em solução azul de metileno a 0,5% por um período de 24 horas, sendo posteriormente seccionados longitudinalmente no sentido mésio-distal para avaliação da penetração do corante, usando para tal o estereo-microscópio. Os resultados foram submetidos à análise estatística através dos testes Qui-quadrado e o teste não-paramétrico U de Mann-Whitney. Os resultados demonstraram não haver diferença estatisticamente significante entre os dois sistemas adesivos testados, podendo-se concluir que a utilização deste protocolo restaurador de cavidades ocluso-proximais com resina composta em molares decíduos resultou em baixos níveis de microinfiltração cervical imediata.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Avaliar a acurácia da colposcopia utilizando a Classificação Colposcópica Internacional de 2002. Métodos: 3040 pacientes de população geral foram rastreadas para patologia cervical através de exame citopatológico, captura híbrida para HPV de alto risco e inspeção cervical. As colposcopias que resultaram em biópsia (n=468) executadas no rastreamento e acompanhamento destas pacientes foram gravadas, revistas por dois colposcopistas cegados e incluídas para análise. Resultados: Os observadores apresentaram excelente concordância (Kappa=0.843) no relato dos achados pela nova nomenclatura. A colposcopia apresentou sensibilidade de 86% e especificidade de 30.3% em diferenciar colo normal de colo anormal (LSIL, HSIL ou carcinoma); quando a colposcopia objetivava diferenciar colo normal ou LSIL de HSIL ou carcinoma, apresentou sensibilidade de 61.1% e especificidade de 94.4%. Os achados colposcópicos classificados como “maiores” pela nova classificação apresentaram valores preditivos positivos elevados para HSIL. Presença do achado colposcópico na zona de transformação e tamanho da lesão estavam associados a HSIL. Bordas externas definidas, associação de múltiplos achados distintos e presença de zona iodo negativa não estavam relacionados à gravidade das lesões. Conclusão: A colposcopia utilizando a Classificação Internacional de 2002 mostra-se um bom método de rastreamento, mas como método diagnóstico apresenta falhas, não podendo substituir a avaliação histológica. A categorização em achados colposcópicos “maiores” e “menores” apresentada pela nova classificação é adequada. Na realização da colposcopia, é importante também que a lesão seja situada em relação à zona de transformação e que seu tamanho seja indicado, já que estes foram fatores associados a lesões de alto grau.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo apresenta o método utilizado e os resultados obtidos na avaliação dos efeitos, na musculatura cervical, de duas facas de corte de frango, de mesma forma e tamanho com cabos confeccionados com dois materiais diferentes (emborrachado, ou SOFT e de polipropileno ou PP). A comparação foi feita com base nos resultados da eletromiografia sensitiva (Myovision) da coluna cervical de dez funcionários voluntários de uma empresa de processamento de aves no Rio Grande do Sul. O protótipo de cabo SOFT mostrou uma menor tensão muscular na coluna cervical em comparação com o protótipo com cabo de polipropileno, o que pode impactar na sensação de maior conforto de manuseio da faca com cabo SOFT.