985 resultados para Bicuspid Aortic Valve
Resumo:
An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.
Resumo:
OBJECTIVE: This review describes and evaluates the results of laparoscopic aortic surgery. METHODS: We describe the different laparoscopic techniques used to treat aortic disease, including (1) total laparoscopic aortic surgery (TLS), (2) laparoscopy-assisted procedures including hand-assisted laparoscopic surgery (HALS), and (3) robot-assisted laparoscopic surgery, with their current indications. Results of these techniques are analyzed in a systematic review of the clinical series published between 1998 and 2008, each containing >10 patients with complete information concerning operative time, clamping time, conversion rate, length of hospital stay, morbidity, and mortality. RESULTS: We selected and reviewed 29 studies that included 1073 patients. Heterogeneity of the studies and selection of the patients made comparison with current open or endovascular surgery difficult. Median operative time varied widely in TLS, from 240 to 391 minutes. HALS had the shortest operating time. Median clamping time varied from 60 to 146 minutes in TLS and was shorter in HALS. Median hospital stay varied from 4 to 10 days regardless of the laparoscopic technique. The postoperative mortality rate was 2.1% (95% confidence interval, 1.4-3.0), with no significant difference between patients treated for occlusive disease or for aneurysmal disease. Conversion to open surgery was necessary in 8.1% of patients and was slightly higher with TLS than with laparoscopy-assisted techniques (P = .07). CONCLUSIONS: Analysis of these series shows that laparoscopic aortic surgery can be performed safely provided that patient selection is adjusted to the surgeon's experience and conversion is liberally performed. The future of this technique in comparison with endovascular surgery is still unknown, and it is now time for multicenter randomized trials to demonstrate the potential benefit of this type of surgery.
Resumo:
OBJECTIVES: The purpose of this study was to determine whether thoracic endovascular aortic repair (TEVAR) reduces death and morbidity compared with open surgical repair for descending thoracic aortic disease. BACKGROUND: The role of TEVAR versus open surgery remains unclear. Metaregression can be used to maximally inform adoption of new technologies by utilizing evidence from existing trials. METHODS: Data from comparative studies of TEVAR versus open repair of the descending aorta were combined through meta-analysis. Metaregression was performed to account for baseline risk factor imbalances, study design, and thoracic pathology. Due to significant heterogeneity, registry data were analyzed separately from comparative studies. RESULTS: Forty-two nonrandomized studies involving 5,888 patients were included (38 comparative studies, 4 registries). Patient characteristics were balanced except for age, as TEVAR patients were usually older than open surgery patients (p = 0.001). Registry data suggested overall perioperative complications were reduced. In comparative studies, all-cause mortality at 30 days (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.33 to 0.59) and paraplegia (OR: 0.42, 95% CI: 0.28 to 0.63) were reduced for TEVAR versus open surgery. In addition, cardiac complications, transfusions, reoperation for bleeding, renal dysfunction, pneumonia, and length of stay were reduced. There was no significant difference in stroke, myocardial infarction, aortic reintervention, and mortality beyond 1 year. Metaregression to adjust for age imbalance, study design, and pathology did not materially change the results. CONCLUSIONS: Current data from nonrandomized studies suggest that TEVAR may reduce early death, paraplegia, renal insufficiency, transfusions, reoperation for bleeding, cardiac complications, pneumonia, and length of stay compared with open surgery. Sustained benefits on survival have not been proven.
Resumo:
PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.
Resumo:
OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.
Resumo:
Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-delà de la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.
Resumo:
A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.
Resumo:
Lung volume reduction with valves is increasingly used to treat selected patients with severe emphysema. The indications for this procedure have been previously described; however, its contraindications have not yet been conclusively established. This case highlights the potentially severe complications of endobronchial one-way valve placement in the setting of a previous pleurodesis.
Resumo:
La rigidité anormalement haute des artères à grande conductance est un marqueur de l'augmentation du risque cardiovasculaire et est typiquement retrouvée chez les patients diabétiques ou hypertendus. Ces vaisseaux deviennent plus rigides avec l'âge, expliquant la haute prévalence d'hypertension systolique chez les personnes âgées. Cette rigidification agit sur la pression sanguine de plusieurs façons. Notamment la fonction windkessel est gênée, menant à l'augmentation de la pression systolique et de la pression puisée, la diminution de la pression diastolique, et ainsi à l'augmentation de la postcharge ventriculaire gauche associée à une probable diminution de la perfusion coronarienne. De plus, la propagation des ondes de pression le long de l'arbre vasculaire est accélérée, de sorte que les ondes réfléchies générées au site de décalage d'impédance atteignent l'aorte ascendante plus tôt par rapport au début de l'éjection ventriculaire, aboutissant à une augmentation de la pression systolique centrale, ce qui n'arriverait pas en présence de vaisseaux moins rigides. Dans ce cas, au contraire, les ondes de pression antérogrades et réfléchies voyages plus lentement, de sorte que les ondes de réflexion tendent à atteindre l'aorte centrale une fois l'éjection terminée, augmentant la pression diastolique et contribuant à la perfusion coronarienne. La tonométrie d'applanation est une méthode non invasive permettant l'évaluation de la forme de l'onde de pression au niveau l'aorte ascendante, basée sur l'enregistrement du pouls périphérique, au niveau radial dans notre étude. Nous pouvons dériver à partir de cette méthode un index d'augmentation systolique (sAIX) qui révèle quel pourcentage de la pression centrale est du aux ondes réfléchies. Plusieurs études ont montré que cet index est corrélé à d'autres mesures de la rigidité artérielle comme la vitesse de l'onde de pouls, qu'il augmente avec l'âge et avec les facteurs de risques cardiovasculaires, et qu'il est capable de préciser le pronostic cardiovasculaire. En revanche, peu d'attention a été portée à l'augmentation de la pression centrale diastolique due aux ondes réfléchies (dAIX). Nous proposons donc de mesurer cet index par un procédé d'analyse développé dans notre laboratoire, et ce dans la même unité que l'index systolique. Etant donné que les modifications de la paroi artérielle modulent d'une part la vitesse de l'onde de pouls (PWV) et d'autre part le temps de voyage aller-retour des ondes de pression réfléchies aux sites de réflexion, toute augmentation de la quantité d'énergie réfléchie atteignant l'aorte pendant la systole devrait être associée à une diminution de l'énergie arrivant au même point pendant la diastole. Notre étude propose de mesurer ces deux index, ainsi que d'étudier la relation de l'index d'augmentation diastolique (dAIX) avec la vitesse de propagation de l'onde de pouls (PWV) et avec le rythme cardiaque (HR), ce dernier étant connu pour influencer l'index d'augmentation systolique (sAIX) . L'influence de la position couchée et assise est aussi étudiée. Les mesures de la PWV et des sAIX et dAIX est réalisée chez 48 hommes et 45 femmes âgées de 18 à 70 ans, classés en 3 groupes d'âges. Les résultats montrent qu'en fonction de l'âge, le genre et la position du corps, il y a une relation inverse entre sAIX et dAIX. Lorsque PWV et HR sont ajoutés comme covariables à un modèle de prédiction comprenant l'âge, le genre et la position du corps comme facteurs principaux, sAIX est directement lié à PWV (p<0.0001) et inversement lié à HR (p<0.0001). Avec la même analyse, dAIX est inversement lié à PWV (p<0.0001) et indépendant du rythme cardiaque (p=0.52). En conclusion, l'index d'augmentation diastolique est lié à la rigidité vasculaire au même degré que l'index d'augmentation systolique, alors qu'il est affranchi de l'effet confondant du rythme cardiaque. La quantification de l'augmentation de la pression aortique diastolique due aux ondes réfléchies pourrait être une partie utile de l'analyse de l'onde de pouls.
Resumo:
BACKGROUND: Pharmacotherapy may represent a potential means to limit the expansion rate of abdominal aortic aneurysms (AAAs). Studies evaluating the efficacy of different pharmacological agents to slow down human AAA-expansion rates have been performed, but they have never been systematically reviewed or summarized. METHODS AND FINDINGS: Two independent reviewers identified studies and selected randomized trials and prospective cohort studies comparing the growth rate of AAA in patients with pharmacotherapy vs. no pharmacotherapy. We extracted information on study interventions, baseline characteristics, methodological quality, and AAA growth rate differences (in mm/year). Fourteen prospective studies met eligibility criteria. Five cohort studies raised the possibility of benefit of beta-blockers [pooled growth rate difference: -0.62 mm/year, (95%CI, -1.00 to -0.24)], but this was not confirmed in three beta-blocker RCTs [pooled RCT growth rate difference: -0.05 mm/year (-0.16 to 0.05)]. Statins have been evaluated in two cohort studies that yield a pooled growth rate difference of -2.97 (-5.83 to -0.11). Doxycycline and roxithromycin have been evaluated in two RCTs that suggest possible benefit [pooled RCT growth rate difference: -1.32 mm/year (-2.89 to 0.25)]. Studies assessing NSAIDs, diuretics, calcium channel blockers and ACE inhibitors, meanwhile, did not find statistically significant differences. CONCLUSIONS: Beta-blockers do not appear to significantly reduce the growth rate of AAAs. Statins and other anti-inflammatory agents appear to hold promise for decreasing the expansion rate of AAA, but need further evaluation before definitive recommendations can be made.
Resumo:
We report on a patient with Marfan syndrome who presented a Stanford type B dissection of the descending thoracic aorta in late pregnancy. After a cesarean section, the patient presented a severe obstruction of the mesenteric superior artery. An endovascular fenestration was performed (balloon and guidewire based fenestration). Computed tomography (CT) angiography revealed an intussusception 'like' image of the abdominal aortic layers as a consequence of the fenestration procedure. Because of aneurismal progression in the abdominal aorta, surgical repair of the abdominal aorta and intussusception material removal was achieved six weeks later. The patient is currently in good condition. We conclude that the intussusception could be induced by a guidewire. This fenestration procedure is not recommended in patients with structural aortic disorders.
Resumo:
Rapport de synthèse Ce travail de thèse s'articule autour de l'importance de l'évaluation de la fonction vasculaire et des répercussions au niveau central, cardiaque, des perturbations du réseau vasculaire. Les maladies cardiovasculaires sont prédominantes dans notre société et causes de morbidité et mortalité importante. La mesure de la pression artérielle classique reste le moyen le plus utilisé pour suivre la santé des vaisseaux, mais ne reflète pas directement ce qui se passe au niveau du coeur. La tonométrie d'aplanation permet depuis quelques années de mesurer l'onde de pouls radial, et par le biais d'une fonction mathématique de transfert validée, il est possible d'en déduire la forme et Γ amplitude de l'onde de pouls central, donc de la pression aortique centrale. Cette dernière est un reflet bien plus direct de la post-charge cardiaque, et de nombreuses études cliniques actuelles s'intéressent à cette mesure pour stratifier le risque ou évaluer l'effet d'un traitement vasculaire. Toutefois, bien que cet outil soit de plus en plus utilisé, il est rarement précisé si la latéralité de la mesure joue un rôle, sachant que certaines propriétés des membres supérieurs peuvent être affectées par un usage préférentiel (masse musculaire, densité osseuse, diamètre des artères, capillarisation musculaire, et même fonction endothéliale). On a en effet observé que ces divers paramètre étaient tous augmentés sur un bras entraîné. Dès lors on peut se poser la question de l'influence de ces adaptations physiologiques sur la mesure indirecte effectuée par le biais du pouls radial. Nous avons investigué les deux membres supérieurs de sujets jeunes et sédentaires (SED), ainsi que ceux de sujets sportifs avec un développement fortement asymétrique des bras, soit des joueurs de tennis de haut niveau (TEN). Des mesures anthropométriques incluant la composition corporelle et la circonférence des bras et avant-bras ont montré que TEN présente une asymétrie hautement significative aux deux mesures entre le bras dominant (entraîné) et l'autre, ce qui est aussi présent pour la force de serrage (mesurée au dynamomètre de Jamar). L'analyse des courbes centrales de pouls ne montre aucune différence entre les deux membres dans chaque groupe, par contre on peut observer une différence entre SED et TEN, avec un index d'augmentation diastolique qui est 50 % plus élevé chez TEN. Les index d'augmentation systolique sont identiques dans les deux groupes. On peut retenir de cette étude la validité de la méthode de tonométrie d'aplanation quel que soit le bras utilisé (dominant ou non-dominant) et ce même si une asymétrie conséquente est présente. Ces données sont clairement nouvelles et permettent de s'affranchir de cette variable dans la mesure d'un paramètre cardiovasculaire dont l'importance est actuellement grandissante. Les différences d'index diastolique sont expliquées par la fréquence cardiaque et la vitesse de conduction de l'onde de pouls plus basses chez TEN, causant un retard diastolique du retour de l'onde au niveau central, phénomène précédemment bien décrit dans la littérature.