966 resultados para Automated neonatal seizure detection
Resumo:
A previously healthy seven-year-old boy was admitted to the intensive care unit because of toxaemia associated with varicella. He rapidly developed shock and multisystem organ failure associated with the appearance of a deep-seated soft tissue infection and, despite aggressive treatment, died on hospital day 4. An M-non-typable, spe A and spe B positive Group A Streptococcus was cultured from a deep soft tissue aspirate. The criteria for defining Streptococcal toxic shock-like syndrome were fulfilled. The authors discuss the clinical and pathophysiological aspects of this disease as well as some unusual clinical findings related to this case.
Resumo:
It is known that fecal examination to detect Giardia lamblia cysts or trophozoites produces a high percentage of false-negative results. A commercially available immunoenzymatic assay (ProSpecT Giardia Microplate Assay, Alexon, Inc., BIOBRÁS) to detect G. lamblia specific coproantigen was evaluated for the first time in Brazil. A total of 90 specimens were tested. Each specimen was first tested as unpreserved stool, and then it was preserved in 10% Formalin to be tested 2 months later. The assay was able to identify all the 30 positive patients (sensitivity = 100.0%) by visual or spectrophotometric examination in the unpreserved specimens and was negative in 57 of the 60 patients without G. lamblia (specificity = 95.0%). The assay identified 27 of the 30 positive patients (sensitivity = 90.0%) and was negative in 59 of the 60 negatives (specificity = 98.3%) in the preserved stools according to both readings. A marked difference was observed in the optical densities in both groups, preserved and unpreserved stools, when the G. lamblia-positive specimens were compared to the negative or positive for other intestinal parasites than G. lamblia. The assay seems a good alternative for giardiasis diagnosis, especially when the fecal examination was repeatedly negative and the patient presents giardiasislike symptoms.
Resumo:
We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial Para obtenção do grau de Mestre em Engenharia Informática
Resumo:
Active infection by T. gondii was evaluated by immunoassay for soluble SAG-1 (p30), the major surface antigen from T. gondii, specific antibodies and immune complexes in human cerebrospinal fluid (CSF) samples. A total of 263 samples of CSF were collected from hospitalized patients presenting neurological disorders and analyzed for antibodies to HIV. Patients were divided into two groups: HIV positive (n = 96) or HIV negative (n =167). The results of the assays showed that 45% of all samples were positive for soluble SAG-1. Toxoplasma Ag/Ab immune complexes were detected in 19% of the CSF samples and 62% were positive for T. gondii- specific IgG. A combination of these assays in the presence of clinical findings consistent with active Toxoplasma infection may predict the presence of toxoplasmic encephalitis. Moreover, detection of soluble SAG-1 in the CSF of these individuals appears consistent with active infection.
Resumo:
Cytomegalovirus (CMV) infection is the most common congenital infection, affecting 0.4% to 2.3% newborns. Most of them are asymptomatic at birth, but later 10% develop handicaps, mainly neurological disturbances. Our aim was to determine the prevalence of CMV shed in urine of newborns from a neonatal intensive care unit using the polymerase chain reaction (PCR) and correlate positive cases to some perinatal aspects. Urine samples obtained at first week of life were processed according to a PCR protocol. Perinatal data were collected retrospectively from medical records. Twenty of the 292 cases (6.8%) were CMV-DNA positive. There was no statistical difference between newborns with and without CMV congenital infection concerning birth weight (p=0.11), gestational age (p=0.11), Apgar scores in the first and fifth minutes of life (p=0.99 and 0.16), mother's age (p=0.67) and gestational history. Moreover, CMV congenital infection was neither related to gender (p=0.55) nor to low weight (<2,500g) at birth (p=0.13). This high prevalence of CMV congenital infection (6.8%) could be due to the high sensitivity of PCR technique, the low socioeconomic level of studied population or the severe clinical status of these newborns.
Resumo:
The possibility of detecting acute infection and immunity using body fluids that are easier to collect than blood, mainly in children, would facilitate the investigation and follow-up of outbreaks of hepatitis A (HAV). Our study was carried out to evaluate the detection of anti-HAV IgM, IgA and total antibodies in saliva using serum samples as reference. Forty three paired serum and saliva samples were analyzed. From this total, 24 samples were obtained from children and 1 from one adult during the course of acute hepatitis A; an additional 18 samples were obtained from health professionals from Adolfo Lutz Institute. The sensitivity to detect anti-HAV IgM was 100% (95%CI: 79.1 to 100.0%), employing saliva as clinical samples. In detecting anti-HAV IgA, the sensitivity was 80.8% (95%CI: 60.0 to 92.7%) and for the total antibodies was 82.1% (95%CI: 62.4 to 93.2%). The specificity was 100% for each. The rate of agreement was high comparing the results of serum and saliva samples for detecting HAV antibodies. We conclude that saliva is an acceptable alternative specimen for diagnosing acute hepatitis A infection, and for screening individuals to receive hepatitis A vaccine or immunoglobulin.
Resumo:
In today’s highly competitive market, it is critical to provide customers services with a high level of configuration to answer their business needs. Knowing in advance the performance associated with a specific choreography of services (e.g., by taking into account the expected results of each component service) represents an important asset that allows businesses to provide a global service tailored to customers’ specific requests. This research work aims at advancing the state-of-the-art in this area by proposing an approach for service selection and ranking using services choreography, predicting the behavior of the services considering customers’ requirements and preferences, business process constraints and characteristics of the execution environment.
Resumo:
Group B Streptococcus is the most common pathogen found in neonatal sepsis in North America. OBJECTIVES: We describe 15 cases of neonatal infections by Group B Streptococcus (Streptococcus agalactiae) at a Neonatal Intensive Care Unit of a public and teaching hospital. METHODS: We conducted a study at Hospital de Clínicas de Porto Alegre, from January 1st, 1996 to June 30, 1999. Diagnosis of neonatal infection was established according to the findings of Group B Streptococcus in blood culture associated with alterations resembling sepsis on the basis of clinical picture and laboratory findings. RESULTS: Fifteen cases of neonatal infections by Group B Streptococcus were detected. Eleven cases consisted of early-onset sepsis, 2 cases of occult bacteremia and 2 cases of late-onset sepsis. Eight cases had septic shock (53%), 8 cases had pneumonia (53%), and 4 cases had meningitis (27%). Fourteen cases were diagnosed from a positive blood culture, and 1 case from evidence of these bacteria in pulmonary anatomopathological examination. Thirteen cases (87%) were diagnosed before 72 hours of life. We had 3 deaths (20%), and 3 cases of meningitis developing neurological deficits. CONCLUSIONS: Streptococcus Group B is one of the most important pathogens in the etiology of early-onset neonatal sepsis at our hospital, with high mortality and morbidity. However, we do not know the incidence of GBS neonatal infections at other hospitals. More data are needed to establish a basis for trials of different strategies to reduce these infections.
Resumo:
The aim of this study was to develop a polymerase chain reaction (PCR) protocol for the detection of Salmonella in artificially contaminated chicken meat. Tests were performed with different dilutions of Salmonella Typhimurium or Salmonella Enteritidis cells (10-7, 10-8 or 10-9 CFU/mL) inoculated in chicken meat samples, in order to establish the limits of detection, incubation times (0, 6, 8 and 24 hours of pre-enrichment in PBW 1%) and three DNA extraction protocols (phenol-chloroform, thermal treatment and thermal treatment and Sephaglass). The assay was able to detect until 10-9 CFU/mL of initial dilution of Salmonella cells inoculated in chicken meat, which allows detection of Salmonella within 48 hours, including 24 hours of pre-enrichment and using the phenol-chloroform DNA extraction protocol. As the results are obtained in a shorter time period than that of microbiological culture, this procedure will be useful in the methodology for detection of Salmonella in chicken.
Resumo:
Eighty-one cerebrospinal fluid (CSF) samples mainly from cases of aseptic meningitis and motor deficiency syndrome were sent to the Virology Section of Evandro Chagas Institute, Belém Pará, in the period of January 1995 to January 1996 in order to isolate viruses. All samples were inoculated onto HEp-2 cell culture and newborn mice, with negative results. The probability of isolating viruses by these methods is reduced because of the low concentration of viral particles in these specimens. In order to obtain more information about the etiology of these cases, a group of 23 samples were selected to be tested by a more sensitive technique than the virus isolation - the reverse transcription polymerase chain reaction (RT-PCR). Specific primers directed to conserved regions in the enterovirus genome were used, considering that this group of viruses is frequently associated with these neurological disorder. The age of the patients ranged from 1 to 55 years and nearly all of them lived in Belém, State of Pará, North of Brazil. Of 15 samples analyzed by RT PCR nine (60%) were positive; of these, 6 (66.6%) had motor deficiency and 3 (33.3%) developed aseptic meningitis. These results show that it is important to investigate enterovirus as cause of these syndromes.
Resumo:
Evidence indicates that exposure to high levels of noise adversely affects human health, and these effects are dependent upon various factors. In hospitals, there are many sources of noise, and high levels exert an impact on patients and staff, increasing both recovery time and stress, respectively. The goal of this pilot study was to develop, implement and evaluate the effectiveness of a training program (TP) on noise reduction in a Neonatal Intensive Care Units (NICU) by comparing the noise levels before and after the implementation of the program. A total of 79 health professionals participated in the study. The measurements of sound pressure levels took into account the layout of the unit and location of the main sources of noise. General results indicated that LAeq levels before implementation of the training program were often excessive, ranging from 48.7 ± 2.94 dBA to 71.7 ± 4.74 dBA, exceeding international guidelines. Similarly following implementation of the training program noise levels remained unchanged (54.5 ± 0.49 dBA to 63.9 ± 4.37 dBA), despite a decrease in some locations. There was no significant difference before and after the implementation of TP. However a significant difference was found for Lp, Cpeak, before and after training staff, suggesting greater care by healthcare professionals performing their tasks. Even recognizing that a TP is quite important to change behaviors, this needs to be considered in a broader context to effectively control noise in the NICU.
Resumo:
Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Ciências do Ambiente pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecn