998 resultados para Agents Map
Resumo:
Despite their widespread use, there is a paucity of information concerning the effect of storage on the rheological properties of pharmaceutical gels that contain organic and inorganic additives. Therefore, this study examined the effect of storage (1 month at either 4 or 37 degrees C) on the rheological and mechanical properties of gels composed of either hydroxypropylmethylcellulose (3-5% w/w, HPMC) or hydroxyethylcellulose (3-5% w/w, HEC) and containing or devoid of dispersed organic (tetracycline hydrochloride 2% w/w) or inorganic (iron oxide 0.1% w/w) agents. The mechanical properties were measured using texture profile analysis whereas the rheological properties were analyzed using continuous shear rheometry and modeled using the Power Law model. All formulations exhibited pseudoplastic flow with minimal thixotropy. Increasing polymer concentration (3-5% w/w) significantly increased the consistency, hardness, compressibility, and adhesiveness of the formulations due to increased polymer chain entanglement. Following storage (I month at 4 and 37 degrees C) the consistency and mechanical properties of additive free HPMC gets (but not HEC gels) increased, due to the time-dependent development of polymer chain entanglements. Incorporation of tetracycline hydrochloride significantly decreased and increased the rheological and mechanical properties of HPMC and HEC gels, respectively. Conversely, the incorporation of iron oxide did not affect these properties. Following storage, the rheological and mechanical properties of HPMC and HEC formulations were markedly compromised. This effect was greater following storage at 37 than at 4 degrees C and, additionally, greater in the presence of tetracycline hydrochloride than iron oxide. It is suggested that the loss of rheological/mechanical structure was due to chain depolymerization, facilitated by the redox properties of tetracycline hydrochloride and iron oxide. These observations have direct implications for the design and formulation of gels containing an active pharmaceutical ingredient. (c) 2005 Wiley Periodicals, Inc.
Resumo:
The effects of three non-antibiotic, antimicrobial agents (taurolidine, chlorhexidine acetate and providone-iodine) on the surface hydrophobicity of the clinical strains Escherichia coli, Staphylococcus saprophyticus, Staphylococcus epidermidis and Candida albicans were examined. Three recognized techniques for hydrophobicity measurements, Bacterial Adherence to Hydrocarbons (BATH), the Salt Aggregation Test (SAT) and Hydrophobic Interaction Chromatography (HIC) were compared. At concentrations reported to interfere with microbial-epithelial cell adherence, all three agents altered the cell surface hydrophobicity. However, these effects failed to exhibit a uniform relationship. Generally, taurolidine and povidone-iodine treatments decreased the hydrophobicity of the strains examined whereas chlorhexidine acetate effects depended upon the micro-organism treated. Subsequently, the exact contribution of altered cell surface hydrophobicity to the reported microbial anti-adherence effects is unclear. Comparison of the three techniques revealed a better correlation between the results obtained with the BATH test and HIC than the results obtained with the BATH and SAT or SAT and HIC. However, these differences may be due to the inaccuracy associated with the visual assessment of results employed by the SAT.
Resumo:
Gold nanoparticles are emerging as promising agents for cancer therapy and are being investigated as drug carriers, photothermal agents, contrast agents and radiosensitisers. This review introduces the field of nanotechnology with a focus on recent gold nanoparticle research which has led to early-phase clinical trials. In particular, the pre-clinical evidence for gold nanoparticles as sensitisers with ionising radiation in vitro and in vivo at kilovoltage and megavoltage energies is discussed.
Resumo:
In this paper, we report the synthesis and biological activity of a series of dihydroisocoumarin analogues Conjugated with fatty acids, alcohols, or amines, of varying hydrocarbon chain length and degree of unsaturation, to (he dihydroisocoumarins, kigelin and mellein, at the C-7 and C-8 positions on the core dihydroisocoumarin structure. These compounds were evaluated for their antiproliferative activity against human breast cancer (MCF-7 and MDA-MB-468) and melanoma cells (SK-MEL-28 and Malme-3M) using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay. Two compounds Conjugated with gamma-linolenyl alcohol (18:3 n-6) demonstrated potent antiproliferative activity in vitro with one of these 4-hydroxy-3-oxo-1.3-dihydro-isobenzofuran-5-carboxylic acid octadeca-6,9,12-trienyl ester, demonstrating significant antitumor activity in vivo ill a number of human tumor xenograft models.
Resumo:
The biennial meeting on 'Exploiting Bacteriophages for Bioscience, Biotechnology and Medicine', held in London, UK, on 20 January 2012, and chaired by George Salmond (University of Cambridge, UK) hosted over 50 participants representing 13 countries. The highly multidisciplinary meeting covered a diverse range of topics, reflecting the current expansion of interest in this field, including the use of bacteriophages as the source of biochemical reagents for molecular biology, bacteriophages for the treatment of human and animal diseases, bacteriophage-based diagnostics and therapeutic delivery technologies and necessity for, and regulatory challenges associated with, robust clinical trials of phage-based therapeutics. This report focuses on a number of presentations from the meeting relating to cutting-edge research on bacteriophages as anti-infective agents.
Resumo:
Barr and Clark published a series of maps depicting the distribution of end moraines across Far NE Russia. These
moraines outlined the former distribution and dimensions of glaciers, and were identified through the analysis of
Landsat ETM+ satellite images (15- and 30-m resolution). Now, a number of freely available digital elevation
model (DEM) datasets are available, which cover the entire 4 million km2 of Far NE Russia. These include
the 30-m resolution ASTER GDEM and the 90-m resolution Viewfinder Panorama DEM. Here we use these
datasets, in conjunction with Landsat ETM+ images, to complete the process of systematically and
comprehensively mapping end moraines. With the aid of the DEMs described above, here we present a total
dataset of 8414 moraines, which almost quadruples the inventory of Barr and Clark. This increase in the
number of moraines is considered to reflect the utility of the DEMs for mapping glacial landforms. In terms of
moraine distribution, the Barr and Clark map and the one presented here are comparable, with moraines found
to cluster in highland regions and upon adjacent lowlands, attesting to the former occupation of the region by
mountain-centred ice masses. This record is considered to reflect palaeoclimatic and topographic controls upon
the extent and dynamics of palaeoglaciers, as well as spatial variability in moraine preservation.
Resumo:
This paper describes an investigation of map width enhancement and a detailed analysis of the inducer flow field due to various bleed slot configurations and vanes in the annular cavity of a turbocharger centrifugal compressor. The compressor under investigation is used in a turbocharger application for a heavy duty diesel engine of approximately 400 hp. This investigation has been undertaken using a computational fluid dynamics (CFD) model of the full compressor stage, which includes a manual multiblock-structured grid generation method. The influence of the bleed slot flow on the inducer flow field at a range of operating conditions has been analyzed, highlighting the improvement in surge and choked flow capability. The impact of the bleed slot geometry variations and the inclusion of cavity vanes on the inlet incidence angle have been studied in detail by considering the swirl component introduced at the leading edge by the recirculating flow through the slot. Further, the overall stage efficiency and the nonuniform flow field at the inducer inlet have been also analyzed. The analysis revealed that increasing the slot width has increased the map width by about 17%. However, it has a small impact on the efficiency, due to the frictional and mixing losses. Moreover, adding vanes in the cavity improved the pressure ratio and compressor performance noticeably. A detail analysis of the compressor with cavity vanes has also been presented.
Resumo:
This paper presents an investigation of map width enhancement and the performance improvement of a turbocharger compressor using a series of static vanes in the annular cavity of a classical bleed slot system. The investigation has been carried out using both experimental and numerical analysis. The compressor stage used for this study is from a turbocharger unit used in heavy duty diesel engines of approximately 300 kW. Two types of vanes were designed and added to the annular cavity of the baseline classical bleed slot system. The purpose of the annular cavity vane technique is to remove some of the swirl that can be carried through the bleed slot system, which would influence the pressure
ratio. In addition to this, the series of cavity vanes provides a better guidance to the slot recirculating flow before it mixes with the impeller main inlet flow. Better guidance of the flow improves the mixing at the inducer inlet in the circumferential direction. As a consequence, the stability of the compressor is improved at lower flow rates and a wider map can be achieved. The impact of two cavity vane designs on the map width and performance of the compressor was highlighted through a detailed analysis of the impeller flow field. The numerical and experimental study revealed that an effective vane design can improve the map width and pressure ratio characteristic without an efficiency penalty compared to the classical bleed slot system without vanes. The comparison study between the cavity vane and noncavity vane configurations presented in this paper showed that the map width was improved by 14.3% due to a significant reduction in surge flow and the peak pressure ratio was improved by 2.25% with the addition of a series of cavity vanes in the annular cavity of the bleed slot system.