984 resultados para ABSOLUTE STEREOSTRUCTURES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leaf wetness duration (LWD) models based on empirical approaches offer practical advantages over physically based models in agricultural applications, but their spatial portability is questionable because they may be biased to the climatic conditions under which they were developed. In our study, spatial portability of three LWD models with empirical characteristics - a RH threshold model, a decision tree model with wind speed correction, and a fuzzy logic model - was evaluated using weather data collected in Brazil, Canada, Costa Rica, Italy and the USA. The fuzzy logic model was more accurate than the other models in estimating LWD measured by painted leaf wetness sensors. The fraction of correct estimates for the fuzzy logic model was greater (0.87) than for the other models (0.85-0.86) across 28 sites where painted sensors were installed, and the degree of agreement k statistic between the model and painted sensors was greater for the fuzzy logic model (0.71) than that for the other models (0.64-0.66). Values of the k statistic for the fuzzy logic model were also less variable across sites than those of the other models. When model estimates were compared with measurements from unpainted leaf wetness sensors, the fuzzy logic model had less mean absolute error (2.5 h day(-1)) than other models (2.6-2.7 h day(-1)) after the model was calibrated for the unpainted sensors. The results suggest that the fuzzy logic model has greater spatial portability than the other models evaluated and merits further validation in comparison with physical models under a wider range of climate conditions. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leaf wetness duration (LWD) is related to plant disease occurrence and is therefore a key parameter in agrometeorology. As LWD is seldom measured at standard weather stations, it must be estimated in order to ensure the effectiveness of warning systems and the scheduling of chemical disease control. Among the models used to estimate LWD, those that use physical principles of dew formation and dew and/or rain evaporation have shown good portability and sufficiently accurate results for operational use. However, the requirement of net radiation (Rn) is a disadvantage foroperational physical models, since this variable is usually not measured over crops or even at standard weather stations. With the objective of proposing a solution for this problem, this study has evaluated the ability of four models to estimate hourly Rn and their impact on LWD estimates using a Penman-Monteith approach. A field experiment was carried out in Elora, Ontario, Canada, with measurements of LWD, Rn and other meteorological variables over mowed turfgrass for a 58 day period during the growing season of 2003. Four models for estimating hourly Rn based on different combinations of incoming solar radiation (Rg), airtemperature (T), relative humidity (RH), cloud cover (CC) and cloud height (CH), were evaluated. Measured and estimated hourly Rn values were applied in a Penman-Monteith model to estimate LWD. Correlating measured and estimated Rn, we observed that all models performed well in terms of estimating hourly Rn. However, when cloud data were used the models overestimated positive Rn and underestimated negative Rn. When only Rg and T were used to estimate hourly Rn, the model underestimated positive Rn and no tendency was observed for negative Rn. The best performance was obtained with Model I, which presented, in general, the smallest mean absolute error (MAE) and the highest C-index. When measured LWD was compared to the Penman-Monteith LWD, calculated with measured and estimated Rn, few differences were observed. Both precision and accuracy were high, with the slopes of the relationships ranging from 0.96 to 1.02 and R-2 from 0.85 to 0.92, resulting in C-indices between 0.87 and 0.93. The LWD mean absolute errors associated with Rn estimates were between 1.0 and 1.5h, which is sufficient for use in plant disease management schemes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Impaired immune system by environmental stressors can lead fishes to be more susceptible to diseases that limit the economic development of aquaculture systems. This study was set out to determine the effect of six levels of mannan oligosaccharides (MOS; ActiveMOS((R)); Biorigin, Lencois Paulista, Sao Paulo, Brazil) on the performance index and hematology of Nile tilapia, Oreochromis niloticus juveniles. Fish (13.62 g) were randomly distributed into 18 plastic aquaria (300 L; 20 fishes per aquarium) and fed during 45 d with a commercial diet supplemented with 0, 0.2, 0.4, 0.6, 0.8, and 1% dietary MOS, in a totally randomized design trial (n = 3); biometrical and hematological data were collected and analyzed. There were no significant differences in hematological parameters between fish fed control and MOS supplementation diets, and daily feed consumption (FC) decreased (P < 0.05) with increasing levels of dietary MOS. Dietary MOS did not increase leukocyte count and presented negative effects on FC of Nile tilapia. At 0.4% MOS supplementation, the individual weight gain was higher in absolute values but not different (P > 0.05) compared to control diet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was conducted to evaluate the natural variability of total, extractable and non-extractable phenolics in pigmented and non-pigmented rice genotypes (Oryza sativa L.) and to estimate whether the contents and distribution of these compounds are typical for genotypes from indica and japonica subspecies. Twenty-one samples of commercial as well as new genotypes of brown rice, including seven pigmented genotypes were obtained from two Agronomic Institutes in South Brazil. Free and conjugated phenolics were extracted with ethanol, while bound phenolics were released by alkaline hydrolysis. Total phenolics were estimated in both fractions by the Folin-Ciocalteau method. Genotypes from Japonica and indica non-pigmented subspecies were not statistically distinguishable from each other, but differences in phenolic contents were associated with pericarp color. Despite individual differences, total phenolics were four times higher in pigmented than in non-pigmented genotypes (4246 and 1073 mg ferulic acid equiv. kg(-1), respectively). These high amounts were mostly due to the presence of extractable (free and conjugated) phenolics, which comprised up to 81% of total phenolics for pigmented genotypes. Non-extractable (bound) phenolics comprised 40% of total phenolics of non-pigmented rice genotypes while pigmented genotypes presented greater absolute amounts, but their contribution on total phenolics was small. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The resazurin microtitre plate assay (REMA) was evaluated to determine the susceptibility of Mycobacterium tuberculosis to pyrazinamide, and was compared with the broth microdilution method (BMM), the absolute concentration method (ACM) and pyrazinamidase (PZase) determination. Methods: Thirty-four M. tuberculosis clinical isolates (26 susceptible and 8 resistant to pyrazinamide) and reference strains M. tuberculosis H37Rv ATCC 27294 and Mycobacterium bovis AN5 were tested. Results: REMA and BMM showed 100% specificity and sensitivity when compared with ACM; BMM, however, demanded more reading time. The PZase determination assay showed 87.50% and 100% sensitivity and specificity, respectively. Conclusions: All tested methods in this preliminary study showed excellent sensitivity and specificity for the determination of pyrazinamide susceptibility of M. tuberculosis, but REMA was faster, low-cost and easy to perform and interpret. Additional studies evaluating REMA for differentiating pyrazinamide-resistant and-susceptible M. tuberculosis should be conducted on an extended panel of clinical isolates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Imatinib (IMAT) is a tyrosine kinase inhibitor that has been used for the treatment of chronic myeloid leukemia (CML). Despite the efficacy of IMAT therapy, some cases of treatment resistance have been described in CML. Developing a plasma method is important since there are several studies that provided a higher correlation between IMAT plasma concentration and response to treatment. Therefore, in this investigation we validated a method by CE as an alternative, new, simple and fast electrophoretic method for IMAT determination in human plasma. The analysis was performed using a fused silica capillary (50 mm id x 46.5 cm total length, 38.0 cm effective length); 50 mmol/L sodium phosphate buffer, pH 2.5, as BGE; hydrodynamic injection time of 20 s (50 mbar); voltage of 30 kV; capillary temperature of 35 degrees C and detection at 200 nm. Plasma samples pre-treatment involved liquid-liquid extraction with methyl-tert-butyl ether as the extracting solvent. The method was linear from 0.125 to 5.00 mg/mL. The LOQ was 0.125 mg/mL. Mean absolute recovery of IMAT was 67%. The method showed to be precise and accurate with RSD and relative error values lower than 15%. Furthermore, the application of the method was performed in the analysis of plasma samples from CML patients undergoing treatment with IMAT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high-performance liquid chromatographic method with triple-quadrupole mass spectrometry detection (LC-MS-MS) was developed and validated for the first time for the simultaneous quantification of zopiclone and its metabolites in rat plasma samples. The analytes were isolated from rat plasma by liquid-liquid extraction and separated using a chiral stationary phase based on an amylose derivative, Chiralpak ADR-H column, and ethanol-methanol-acetonitrile (50:45:5, v/v/v) plus 0.025% diethylamine as the mobile phase, at a flow-rate of 1.0 mL min(-1). Moclobemide was used as the internal standard. The developed method was linear over the concentration range of 7.5-500 ng mL(-1). The mean absolute recoveries were 74.6 and 75.7; 61.6 and 56.9; 72.5, and 70.7 for zopiclone enantiomers, for N-desmethyl zopiclone enantiomers and for zopiclone-N-oxide enantiomers, respectively, and 75.9 for the internal standard. Precision and accuracy were within acceptable levels of confidence (<15%). The method application in a pilot study of zopiclone kinetic disposition in rats showed that the levels of (+)-(S)-zopiclone were always higher than those of (-)-R-zopiclone. Higher concentrations were also observed for (+)-(S)-N-desmethyl zopiclone and (+)-(S)-N-oxide zopiclone, confirming the stereoselective disposition of zopiclone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the determination of artemether (ART) and its main metabolite dihydroartemisinin (DHA) in plasma employing liquid-phase microextraction (LPME) for sample preparation prior to liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed. The analytes were extracted from 1 nil, of plasma utilizing a two-phase LPME procedure with artemisinin as internal standard. Using the optimized LPME conditions, mean absolute recovery rates of 25 and 32% for DHA and ART, respectively, were achieved using toluene-n-octanol (1:1, viv) as organic phase with an extraction time of 30 min. After extraction, the analytes were resolved within 5 min using a mobile phase consisting of methanol-ammonium acetate (10 mmol L(-1) pH 5.0, 80:20. v/v) on a laboratory-made column based on poly(methyltetradecylsiloxane) attached to a zirconized-silica support. MS-MS detection was employed using an electrospray interface in the positive ion mode. The method developed was linear over the range of 5-1000 ng mL(-1) for both analytes. Precision and accuracy were within acceptable levels of confidence (<15%). The assay was applied to the determination of these analytes in plasma from rats treated with ART. The two-phase LPME procedure is affordable and the solvent consumption was very low compared to the traditional methods of sample preparation. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flavone C-glucoside, vicenin-2, in semi-purified extracts of the leaves of Lychnophora ericoides was quantified in rat plasma samples using a method based on reversed-phase high performance liquid chromatography coupled to tandem mass spectrometry. Vicenin-2 was analyzed on a LiChrospher (R) RP18 column using an isocratic mobile phase consisting of a mixture of methanol: water (30:70, v/v) plus 2.0% glacial acetic acid at a flow rate of 0.8 mL min(-1). Genistein was used as internal standard. The mass spectrometer was operated in positive ionization mode and analytes were quantified by multiple reaction monitoring at m/z 595 > 457 for vicenin-2 and m/z 271 > 153 for internal standard. Prior to the analysis, each rat plasma sample was acidified with 200 mu L of 50 mmol L(-1) acetic acid solution and extracted by solid-phase extraction using a C18 cartridge. The absolute recoveries were reproducible and the coefficients of variation values were lower than 5.2%. The method was linear over the 12.5 - 1500 ng mL(-1) concentration range and the quantification limit was 12.5 ng mL(-1). Within-day and between-day assay precision and accuracy were studied at three concentration levels (40, 400 and 800 ng mL(-1)) and were lower than 15%. The developed and validated method seems to be suitable for analysis of vicenin-2 in plasma samples obtained from rats that receive a single i.p. dose of 200 mg kg(-1) vicenin-2 extract.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the simultaneous analysis of the enantiomers of mefloquine (MQ) and its main metabolite carboxymefloquine (CMQ) in plasma is described for the first time. The assay involves two-step liquid-phase micro-extraction (LPME) and enantioselective high-performance liquid chromatography. In the first LPME step, the enantiomers of MQ were extracted from an alkalinized sample through a thin layer of di-n-hexyl ether immobilized in the pores of the hollow fiber and into 0.01 M perchloric acid as acceptor solution. In the second LPME step, the same sample was acidified to enable the extraction of CMQ using the same organic solvent and 0.05 M sodium hydroxide as acceptor phase. The analytes were resolved on a Chirobiotic T column in the polar-organic mode of elution and detected at 285 nm. The recovery rates from 1 mL of plasma were in the range 35-38%. The method presented limits of quantification of 50 ng/mL for all analytes and was linear up to 1,500 and 3,000 ng/mL for the enantiomers of MQ and CMQ, respectively. The plasmatic concentrations of (+)-(RS)-MQ were higher than those of (-)-(SR)-MQ after oral administration of the racemic drug to rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and fast method is described for simultaneous determination of methylmercury (MeHg), ethylmercury (Et-Hg) and inorganic mercury (Ino-Hg) in blood samples by using capillary gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS) after derivatization and alkaline digestion. Closed-vessel microwave assisted digestion conditions with tetramethylammonium hydroxide (TMAH) have been optimized. Derivatization by using ethylation and propylation procedures have also been evaluated and compared. The absolute detection limits (using a 1 mu L injection) obtained by GC-ICP-MS with ethylation were 40 fg for MeHg and Ino-Hg, respectively, and with propylation were 50, 20 and 50 fg for MeHg, Et-Hg and Ino-Hg, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). Additional validation is provided based on the comparison of results obtained for mercury speciation in blood samples with the proposed procedure and with a previously reported LC-ICP-MS method. With the new proposed procedure no tedious clean-up steps are required and a considerable improvement of the time of analysis was achieved compared to other methods using GC separation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report absolute values for the radiative relaxation quantum yield of synthetic eumelanin as a function of excitation energy. These values were determined by correcting for pump beam attenuation and emission reabsorption in both eumelanin samples and fluorescein standards over a large range of concentrations. Our results confirm that eumelanins are capable of dissipating >99.9% of absorbed UV and visible radiation through nonradiative means. Furthermore, we have found that the radiative quantum yield of synthetic eumelanin is excitation energy dependent. This observation is supported by corrected emission spectra, which also show a clear dependence of both peak position and peak width on excitation energy. Our findings indicate that photoluminescence emission in eumelanins is derived from ensembles of small chemically distinct oligomeric units that can be selectively pumped. This hypothesis lends support to the theory that the basic structural unit of eumelanin is oligomeric rather than heteropolymeric.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show that quantum mechanics predicts a contradiction with local hidden variable theories for photon number measurements which have limited resolving power, to the point of imposing an uncertainty in the photon number result which is macroscopic in absolute terms. We show how this can be interpreted as a failure of a new premise, macroscopic local realism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reviews the potential use of three types of spatial technology to land managers, namely satellite imagery, satellite positioning systems and supporting computer software. Developments in remote sensing and the relative advantages of multispectral and hyperspectral images are discussed. The main challenge to the wider use of remote sensing as a land management tool is seen as uncertainty whether apparent relationships between biophysical variables and spectral reflectance are direct and causal, or artefacts of particular images. Developments in satellite positioning systems are presented in the context of land managers’ need for position estimates in situations where absolute precision may or may not be required. The role of computer software in supporting developments in spatial technology is described. Spatial technologies are seen as having matured beyond empirical applications to the stage where they are useful and reliable land management tools. In addition, computer software has become more user-friendly and this has facilitated data collection and manipulation by semi-expert as well as specialist staff.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Investigation of a southern Australian marine sponge, Mycale sp., resulted in isolation of the known norsesterterpenes 1-3 as well as two new isomeric norsesterterpenes, mycaperoxide C methyl ester (4) and mycaperoxide D methyl ester (5), and six new norterpenes (6-11).