867 resultados para Águas profundas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blooms of phytoplankton can be a risk to human health and aquatic biota, so the adoption of monitoring methods of phytoplankton and mechanisms for preventing its occurrence are needed. Thus, traditional monitoring methods could be more effective if complemented by approaches using the optical properties of phytoplankton pigments by means of Remote Sensing. In order to evaluate the potential of multi-scale remote sensing for detection of the phytoplankton activity, a study area was selected in Nova Avanhandava reservoir, located in the Tiete River, SP. For this analysis, hyperspectral field data and multispectral images of low and medium spatial resolution (Modis and RapidEye) were acquired and were related to indicator limnological variables of phytoplankton behavior; chlorophyll a and phycocyanin. The results show that a specific spectral band of RapidEye system (690-730 nm) allowed detect chlorophyll a and to evaluate the phytoplankton biomass, however hyperspectral data are needed to detect the phycocyanin pigment, indicative of cyanobacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water and soil pollution caused by the waste from the swine production causes severe environmental impacts in producing areas. An efficient alternative to reduce these impacts can be the use of high-rate anaerobic reactors. In this work, it was evaluated the effect of the swine wastewater with total suspended solids concentrations around 6.000 mg.L-1 in the anaerobic baffled reactor with three compartments. The volume of the first compartment was 210 L and of the second and third ones of 160 L. The anaerobic baffled reactor was submitted at hydraulic detention times of 56, 28 and 18 hours and to organic load rates of 5.0 to 10.1 g total COD (L.d)(-1). The highest total COD removals, of 42 to 68%, and volumetric methane productions, of 0.261 to 0.454 L CH4 (L reactor d)(-1), occurred in the second compartment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The fluoridation surveillance in the public water supply came up with the need to develop mechanisms that would help society in the control of water quality. To perform reliable analysis, variables such as depth of the wells and pluvial variations should be subject of research and study. Objectives: To analyze the fluoride levels of deep wells in periods of rain and drought, corresponding to four brazilian cities and compare the results. Methodology: It was made the mapping of the water supply network and the identification of the sampling points according to the number of deep wells in each locality, selecting those who had the natural fluoride level. Three points were defined for each source of water supply, and the addresses were randomly selected. The samples were analyzed in duplicate at the laboratory of the Center for Research in Public Health of the Dentistry School of Araçatuba – UNESP, during 8 months, in periods of rain and drought (total absence of rain). Results: 174 analysis were conducted, the mean fluoride levels for rain and drought times were, respectively: 0,71 and 0,73. It was used the Student’s t test (p <0.05). Conclusion: There wasn’t statistically significant differences for the periods of rain and drought in any of the cities, at the year of 2010. This study highlights the importance of health surveillance, because beyond of ensuring social control, there is also the search for investigating variables that may have directly and / or indirectly influence on the results of the analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maintaining the levels of fluoride ion in public water supply within the parameters of adequacy it becomes essential so the measure carries a greater impact on caries prevention and control, without increasing the prevalence of dental fluorosis. Thus, it is necessary a rigorous control of the process, avoiding the undesired effects at levels above recommended levels, as well as avoiding levels below the recommended that do not offer the highest benefit. The aim of this study was to analyze the content of fluoride in public water supply in the city of Birigui, SP, with different sources of supply, checking if the fluoride levels are within the recommended. The samples were collected monthly from points previously established, with the knowledge of the distribution network of water and identifying the amount and location of supply sources and water treatment plant. Analyses were performed in duplicate in the period from January to December of 2009, in the laboratory - NEPESCO - of the Dental School of Araçatuba, Univ Estadual Paulista – UNESP, using an ion analyzer coupled to a specific electrode for fluoride. Of the total samples (n = 512), 44% (n = 224) had adequate levels and 56% (n = 288) inadequate levels, 10% (n = 49) lower levels and 46% (n = 239) showed levels above the recommended. There were differences in results when comparing the analysis of different sources. The fluoride concentration in the majority of the samples from deep wells was classified as inadequate not offering the desired benefit, or exposing the population to the risk of dental fluorosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo a Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluoridation of water for human consumption is a method of caries prevention that brings great social benefit, if kept at optimal levels. The increase in the production of bottled water emphasizes the need to verify whether fluoride presence in these waters occurs in sufficient quantity to prevent decay, or if it represents a significant risk of fluorosis. Objective: to compare the concentrations of fluoride present in bottled water to those declared on the labels, and to make a critical analysis of legal norms on the subject. Materials and method: this was a cross-sectional study, through which 22 samples of bottled water sold in state of Ceará, Brazil, were analyzed. Analyses were performed in duplicate by the electrometric method, and results were compared to those printed on the labels. Detailed searches by laws, resolutions, ordinances, and other official documents in force, related to the topic were performed. Results: the fluoride concentrations found ranged from 0.01 to 0.36 mgF/l. Although 72.7% of the samples were classified as fluoridated, the fluoride concentrations observed were shown to be insufficient for caries prevention. As for the rules, situations where they are not clear or even divergent were found. Conclusion: the current legislation on the subject requires updates to become more objective and to create new criteria on the use of the term “fluoridated water”.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water quality is very important for the health and the population welfare, and the public supply system must provide water quality and suffi cient quantity for the entire population. Water treatment stations, are the main way to obtain water quality. When this doesn’t occur, several problems can affect the population, in this case, using water with poor quality is a constant risk of emergence causing various diseases. The elimination of microorganisms in treated water reduces competition, encouraging the multiplication of chlorine resistant bacteria as Mycobacterium genus frequently isolated from treated and chlorinated water. Considering the lack of indication from examinations of mycobacteria routine laboratory for quality control of drinking water and other human uses, the objective was to verify the presence isolate and identify the environmental mycobacteria in the system water source surface of Araraquara - SP. We analyzed 40 water samples, distributed as follows: ten water gross collected at Station Water Treatment Plant (WTP), harvested after ten fi ltration; ten collected in the reservoir after chlorination and ten in the network distribution. Were recovered 43 isolates of mycobacteria. All isolates were subjected to PCR-PRA. The mycobacteria were identifi ed as M. lentifl avum, M. parafortuitum, M. genavense, M. gordonae, M. fortuitum, M. confl uent, M. duvalii, M. avium subspecies paratuberculosis and M. szulgai. With these results, was concluded that water is an important source of environmental mycobacteria probably related to several human diseases, suggesting the carrying out continuous monitoring of the microorganisms in the system drinking water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência Animal - FMVA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Microbiologia Aplicada) - IBRC