1000 resultados para technique de soi


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A process of heat treating Mas min at 125°C for 15 minutes and hermetically packing them up has been investigated. This method has been found to be successful in controlling insect infestation in Mas min. The Japanese method of packing Mas min in BHC coated containers has also been simultaneously examined and found successful under certain conditions. However, this process is found to impart slight undesirable flavors to the product. In addition, this chemical treatment is also likely to be more costly.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel technique for automated topographical analysis in the SEM has been investigated. It utilizes a 16-bit minicomputer arranged to act as an automatic focusing unit. The computer is coupled to the objective lens of the microscope, by means of a digital to analogue converter, and may regulate the excitation of the lens under program control. Further digital-to-analogue converters allow the computer to act as a programmable scan generator by applying ramp waveforms to the scan amplifiers, permitting the beam to be swept over a small sub-region of the field of interest. The video signal is sampled and applied to an analogue-to-digital converter; the resultant binary numbers are stored in computer memory as an array of values representing relative image intensities within a subregion. A differencing algorithm applied to the collected data allows the level of objective lens excitation to be found at which the sharpness of the image is optimized, and the excitation may be related to the working distance for that subregion through a previous calibration experiment. The sensitivity of the method for detecting small height changes is theoretically of the order of 1 μm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An explanation for the observed variations in the output behaviour of SOI transistors with different buried oxide thicknesses is presented. At low drain bias, the temperature effects are relatively insignificant while at high drain bias, the temperature effects dominate the nonlinear behaviour of the output characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wavelength conversion device was demonstrated at the bit rate of 2.488 Gb/s with 2R (reamplification and reshaping) regenerative properties. A low frequency pilot tone was removed during the conversion process and a new one added. The wavelength converter is shown to operate well at 10 Gb/s, and tone identification/replacement should also be possible at this data rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To overcome reduced breakdown voltage and self-heating effects inherent in silicon-on-insulator (SOI) power integrated circuits while still maintaining good isolation between low power CMOS circuits and the high power cells, partial SOI (PSOI) technology has been proposed. PSOI devices make use of both buried oxide and substrate depletion to support the breakdown voltage. 2D analyses and modeling of parasitic capacitances in PSOI structures show that PSOI-lightly doped MOSFETs can increase the switching speed by as much as four times compared to conventional SOI structures, making them very attractive for high switching applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Etched VCSEL sources are reported which avoid bandwidth collapse in multimode fibre using a simple coupling technique to control the launch. These devices have allowed better than over-filled launch bandwidth for alignment tolerances of ±7 microns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique to measure wall flow variation in Diesel Particle Filters (DPFs) is described. In a recent paper, it was shown how the flow distribution in DPFs could be measured in a non-destructive manner. This involved measuring the progressive dilution of a tracer gas introduced at the "outlet" channel upstream end. In the present paper, a significant further improvement to this technique is described, in which only a single probe is required, rather than the two of the previous technique. The single, traversable, probe consists of a controllable flow sink, and slightly downstream, a tracer gas supply. By controlling the sink flow rate such that a very small concentration of tracer gas is aspirated into it, the total flow up to that location in the channel is determined. Typical results showing the axial variation in the wall flow for known wall blockage cases are presented. It is suggested that this technique could be used to interpret the soot loading in the filter channels in a non-intrusive way.