854 resultados para stress analysis methods
Resumo:
The mucosa that covers the residual ridges of edentulous patients may present some distortion or displacement when occlusal loading is applied in complete dentures. This distortion and movement of the denture can result in acceleration of residual ridge resorption and loss of retention and stability. The aim of this study was to analyze the pattern of upper complete denture movement related to underlying mucosa displacement. A sample of 10 complete denture wearers was randomly selected, which had acceptable upper and lower dentures and normal volume and resilience of residual ridges. The kinesiographic instrument K6-I Diagnostic System was used to measure denture movements, according to the method proposed by Maeda et al.7, 1984. Denture movements were measured under the following experimental conditions: (A) 3 maximum voluntary clenching cycles and (B) unilateral chewing for 20 seconds. The results showed that under physiological load, oral mucosa distortion has two distinct phases: a fast initial displacement as load is applied and a slower and incomplete recovery when load is removed. Intermittent loading such as chewing progressively reduces the magnitude of the denture displacement and the recovery of the mucosa is gradually more incomplete.
Resumo:
Distribution systems with distributed generation require new analysis methods since networks are not longer passive. Two of the main problems in this new scenario are the network reconfiguration and the loss allocation. This work presents a distribution systems graphic simulator, developed with reconfiguration functions and a special focus on loss allocation, both considering the presence of distributed generation. This simulator uses a fast and robust power flow algorithm based on the current summation backward-forward technique. Reconfiguration problem is solved through a heuristic methodology and the losses allocation function, based on the Zbus method, is presented as an attached result for each obtained configuration. Results are presented and discussed, remarking the easiness of analysis through the graphic simulator as an excellent tool for planning and operation engineers, and very useful for training. © 2004 IEEE.
Resumo:
This study investigated the flexural strength of eight fiber posts (one carbon fiber, one carbon/quartz fiber, one opaque quartz fiber, two translucent quartz fiber, and three glass fiber posts). Eighty fiber posts were used and divided into eight groups (n = 10): G1: C-POST (Bisco); G2: ÆSTHETI-POST (Bisco); G3: ÆSTHETI-PLUS (Bisco); G4: LIGHT-POST (Bisco); G5: D.T. LIGHT-POST (Bisco); G6: PARAPOST WHITE (Coltene); G7: FIBERKOR (Pentron); G8: REFORPOST (Angelus). All of the samples were tested using the three-point bending test. The averages obtained were submitted to the ANOVA and to Tukey's test (p < 0.05). The mean values (MPa) of the groups ÆSTHETI-POST - carbon/ quartz fiber post (Bisco) and ÆSTHETI-PLUS - quartz fiber post (Bisco) were statistically similar and higher than the mean values of the other groups. The mean values of the groups C-POST - carbon fiber post (Bisco), LIGHT-POST - translucent quartz fiber post (Bisco), D.T. LIGHT-POST - double tapered translucent quartz fiber post (Bisco), PARAPOST WHITE - glass fiber post (Coltene) and FIBREKOR - glass fiber post (Pentron) were similar and higher than the group REFORPOST - glass fiber post (Angelus). Copyright © 2005 by the American Association of Endodontists.
Resumo:
Purpose: This study intends to evaluate BMP (Bone Morphogenetic Protein) implant and BMP implant plus PRP (Platelet Rich Plasma) in rabbit orbital fractures, searching for tissue reaction, by radiological and morfometrical analysis. Methods:Third six white rabbits were submitted to orbital floor fracture and distributed in three groups: G1, with rabbits receiving a plate containing decalcified bone matrix and BMP; G2, with rabbits receiving the implant with BMP wrapped by PRP; G3, the control group where it was made the fracture only. The animals were evaluated radiologically after surgery and at sacrifice time in 7, 30, 90 and 180th day after surgery. After sacrifice, a block containing the right orbital tissue was extracted and prepared to morphological and morphometrical analysis. Results: An intensive linfomononuclear inflammatory reaction was observed at 7th day in G1 e G2, witch decreased after the 30th day; mesenchimal cells, osteoblasts, new bone and progressive cavitation of the implant were also observed, besides signs of calcium deposition by radiological study. In the control group fibrosis at the site of fracture was identified only. Conclusion: BMP seemed a good orbital implant producing new bone at the implant site and correcting bone defect.There was not observed acceleration of osteoinduction when the implant was associated with PRP.
Resumo:
Objective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.
Resumo:
This study aimed to compare the microtensile bond strength of resin cement to alumina-reinforced feldspathic ceramic submitted to acid etching or chairside tribochemical silica coating. Ten blocks of Vitadur-α were randomly divided into 2 groups according to conditioning method: (1) etching with 9.6% hydrofluoric acid or (2) chairside tribochemical silica coating. Each ceramic block was luted to the corresponding resin composite block with the resin cement (Panavia F). Next, bar specimens were produced for microtensile testing. No significant difference was observed between the 2 experimental groups (Student t test, P> .05). Both surface treatments showed similar microtensile bond strength values.
Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization.
Resumo:
OBJECTIVES: To evaluate, at different times, the diametral tensile strength (DTS) of dual-curing resin cements that were not photopolymerized. METHOD AND MATERIALS: Equal amounts of base and catalyst pastes of Panavia F (Kuraray), Variolink II (Vivadent), Rely X (3M ESPE), and Enforce (Dentsply) were mixed and inserted into cylindrical molds (4 x 2 mm) (n = 10). Cements were not photopolymerized. DTS test was performed in a testing machine at 30 minutes, 1 hour, 24 hours, and 7 days. The specimens were stored in light-proof containers with distilled water at 37 degrees C until the time of assay. An autopolymerizing resin cement (Cement-It, Jeneric Pentron) and a zinc phosphate cement served as controls. One-way analysis of variance (ANOVA) and Tukey test were performed separately for each cement and for each time (P <.05). RESULTS: All cements showed an increase in DTS when tested at 1 and 24 hours. Tests at 24 hours and 7 days revealed no statistically significant differences. In all groups, the zinc phosphate cement had the lowest DTS mean values (2.1 MPa, 3.6 MPa, 6.5 MPa, and 6.9 MPa), while Cement-It (35.1 MPa, 33.6 MPa, 46.9 MPa, and 46.3 MPa) and Enforce (31.9 MPa, 31.7 MPa, 43.4 MPa, and 47.6 MPa) presented the highest DTS mean values. CONCLUSION: All cements presented maximal strength at 24 hours. The dual-curing resin cements, even when nonphotopolymerized, demonstrated higher DTS than the zinc phosphate cement and similar or lower values than the autopolymerizing resin cement.
Resumo:
This study evaluated the effect of post surface conditioning on the fatigue resistance of bovine teeth restored with resin-bonded fiber-reinforced composite (FRC). Root canals of 20 single-rooted bovine teeth (16 mm long) were prepared to 12 mm using a preparation drill of a double-tapered fiber post system. Using acrylic resin, each specimen was embedded (up to 3.0 mm from the cervical part of the specimen) in a PVC cylinder and allocated into one of two groups (n = 10) based on the post surface conditioning method: acid etching plus silanization or tribochemical silica coating (30 μm SiOx + silanization). The root canal dentin was etched (H2PO3 for 30 seconds), rinsed, and dried. A multi-step adhesive system was applied to the root dentin and the fiber posts were cemented with resin cement. The specimens were submitted to one million fatigue cycles. After fatigue testing, a score was given based on the number of fatigue cycles until fracture. All of the specimens were resistant to fatigue. No fracture of the root or the post and no loss of retention of the post were observed. The methodology and the results of this study indicate that tribochemical silica coating and acid etching performed equally well when dynamic mechanical loading was used.
Resumo:
This study verified the effect of unilateral teeth extraction on the periodontal ligament in gerbils (Meriones unguiculatus). Ten adult male gerbils weighing about 50 g had induced occlusal alterations by upper left molar extractions while the other ten animals, only submitted to surgical stress, were considered as controls. The periodontal ligament was characterized by qualitative and quantitative analysis, histological description and histomorphometric quantification. Significant alterations were observed on the left side of the experimental group (P < 0.05), the hypofunctional region, when it was compared with the contralateral side and the corresponding region of the control group. Two months after occlusal alterations induced by unilateral teeth extraction, atrophic histological alterations and a decrease in the periodontal space on the ipsilateral side characterized the periodontal ligament. In this study it was possible to conclude that the gerbil can be used in experimental models attempting to correlate the periodontium's biological response to various mechanical stresses, as the periodontal ligament was shown to be highly sensitive to occlusal alterations. © 2008 The Authors.
Resumo:
This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74°C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (α=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.
Resumo:
This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.
Resumo:
The Paraguay River is the main tributary of the Paraná River and has an extension of 1.693 km in Brazilian territory. The navigability conditions are very important for the regional economy because most of the central-west Brazilian agricultural and mineral production is transported by the Paraguay waterway. Increased sedimentation along the channel requires continuous dredging to waterway maintenance. Systematic bathymetric surveys are periodically carried out in order to check depth condition along the channel using echo-sounding devices. In this paper, digital image processing and geostatistical analysis methods were used to analyze the applicability of the ASTER sensor to estimate channel depths in a segment of the upper Paraguay River. The results were compared with field data in order to choose the band with better adjustment and to evaluate the standard deviation. Comparing the VNIR bands, the best fit was presented by the red wavelength (band 2; 0,63 - 0,69 μm), showing a good representation of the channel depths shallow than 1,7 m. Applying geostatistical methods, the model accuracy was enhanced from 43 cm to 36 cm and undesired components were slacked. It was concluded that the digital number of band 2, converted to bathymetry information allows a good estimation of river depths and channel morphology.
Resumo:
The aim of this study was to evaluate the dimensional stability and detail reproduction of two silicones used for facial prosthesis, under the influence of chemical disinfection and storage time. Twenty-eight test specimens were obtained, half made of Silastic MDX 4-4210 silicone, and the other half of Silastic 732 RTV silicone. The test specimens were divided into 4 groups: Silastic 732 RTV and Silastic MDX 4-4210, with disinfection 3 times a week with Efferdent and without disinfection. Dimensional change was analyzed using an electronic comparison microscope and detail reproduction was observed under a stereo microscope, immediately and 2 months after the test specimens were made. Once the results were obtained, an analisis of variance (ANOVA) was applied, followed by the Tukey's Test with 1% confidence. The storage time factor had a statistical influence on dimensional stability: Silastic MDX 4-4210 had less contraction than Silastic 732 RTV. Chemical disinfection did not significantly alter the dimensional stability of the materials used. Regarding detail reproduction, no alteration of values was observed in any of the materials analyzed, regardless of storage period or disinfection.
Resumo:
The aim of this study was to evaluate the effect of radiotherapy on the radiopacity and flexural strength of composite resin. Forty Z250 composite resin specimens were polymerized using a halogen light-curing unit and divided into 5 groups, in accordance with the radiotherapy dose: G1- without irradiation, G2- 30 Gy, G3- 40 Gy, G4- 50 Gy and GS- 60 Gy Digital images were obtained using a GE 100 X-ray. Radiopacity values were obtained with the Digora digital imaging system and the flexural strength was evaluated with an EMIC universal testing machine. Data were submitted to ANOVA and Tukey 's test. G1 presented the highest radiopacity value, followed by G3, G5, G4 and G2. For flexural strength, G1 presented the lowest value, followed by G2, G5, G3 and G4. Differences were no significant (p>0.05). The commonly used dosage of radiotherapy treatment, did not cause alteration in the radiopacity and flexural strength of resin-based composites.