956 resultados para saturation magnetization
Resumo:
Multi-parametric and quantitative magnetic resonance imaging (MRI) techniques have come into the focus of interest, both as a research and diagnostic modality for the evaluation of patients suffering from mild cognitive decline and overt dementia. In this study we address the question, if disease related quantitative magnetization transfer effects (qMT) within the intra- and extracellular matrices of the hippocampus may aid in the differentiation between clinically diagnosed patients with Alzheimer disease (AD), patients with mild cognitive impairment (MCI) and healthy controls. We evaluated 22 patients with AD (n=12) and MCI (n=10) and 22 healthy elderly (n=12) and younger (n=10) controls with multi-parametric MRI. Neuropsychological testing was performed in patients and elderly controls (n=34). In order to quantify the qMT effects, the absorption spectrum was sampled at relevant off-resonance frequencies. The qMT-parameters were calculated according to a two-pool spin-bath model including the T1- and T2 relaxation parameters of the free pool, determined in separate experiments. Histograms (fixed bin-size) of the normalized qMT-parameter values (z-scores) within the anterior and posterior hippocampus (hippocampal head and body) were subjected to a fuzzy-c-means classification algorithm with downstreamed PCA projection. The within-cluster sums of point-to-centroid distances were used to examine the effects of qMT- and diffusion anisotropy parameters on the discrimination of healthy volunteers, patients with Alzheimer and MCIs. The qMT-parameters T2(r) (T2 of the restricted pool) and F (fractional pool size) differentiated between the three groups (control, MCI and AD) in the anterior hippocampus. In our cohort, the MT ratio, as proposed in previous reports, did not differentiate between MCI and AD or healthy controls and MCI, but between healthy controls and AD.
Resumo:
The hippocampal formation (HF) of healthy control subjects and schizophrenic patients was examined using an MRI experiment that implements sequences for relaxometry and magnetization transfer (MT) quantification. In addition to the semi-quantitative magnetization transfer ratio (MTR), all of the observable properties of the binary spin bath model were included. The study demonstrates that, in contrast to the MTR, quantitative MT parameters (especially the T2 relaxation time of restricted protons, T2b) are capable to differentiate functionally significant subregions within the HF. The MT methodology appears to be a promising new tool for the differential microstructural evaluation of the HF in neuropsychiatric disorders accompanied by memory disturbances.
Resumo:
1 Natural soil profiles may be interpreted as an arrangement of parts which are characterized by properties like hydraulic conductivity and water retention function. These parts form a complicated structure. Characterizing the soil structure is fundamental in subsurface hydrology because it has a crucial influence on flow and transport and defines the patterns of many ecological processes. We applied an image analysis method for recognition and classification of visual soil attributes in order to model flow and transport through a man-made soil profile. Modeled and measured saturation-dependent effective parameters were compared. We found that characterizing and describing conductivity patterns in soils with sharp conductivity contrasts is feasible. Differently, solving flow and transport on the basis of these conductivity maps is difficult and, in general, requires special care for representation of small-scale processes.
Resumo:
Field soils show rather different spreading behavior at different water saturations, frequently caused by layering of the soil material. We performed tracer experiments in a laboratory sand tank. Such experiments complement and help comprehension of field investigations. We estimated, by image analysis, the first two moments of small plumes traveling through a two-dimensional, heterogeneous medium with strongly anisotropic correlation structure. Three steady state regimes were analyzed. Two main conclusions were drawn. First, low saturation led to very large heterogeneity and to strong preferential flow. Thus the description of the flow paths and the prediction of the solute arrival times require, in this case, more accurate knowledge about the topological structure. Second, saturation-dependent macroscopic anisotropy is an essential element of transport in unsaturated media. For this reason, small structural soil features should be properly upscaled to give appropriate effective soil parameters to be input in transport models.
Resumo:
Cardiovascular magnetization transfer ratio (MTR) imaging by steady state free precession is a promising imaging method to assess microstructural changes within the myocardium. Hence, MTR imaging was correlated to histological analysis. Three postmortem cases were selected based on a suspicion of myocardial infarction. MTR and T2 -weighted (T2w ) imaging was performed, followed by autopsy and histological analysis. All tissue abnormalities, identified by autopsy or histology, were retrospectively selected on visually matched MTR and T2w images, and corresponding MTR values compared with normal appearing tissue. Regions of elevated MTR (up to approximately 20%, as compared to normal tissue), appearing hypo-intense in T2w -images, revealed the presence of fibrous tissue in microscopic histological analysis. Macroscopic observation (autopsy) described scar tissue only in one case. Regions of reduced MTR (up to approximately 20%) corresponded either to (i) the presence of edema, appearing hyperintense in T2w -images and confirmed by autopsy, or to (ii) inflammatory granulocyte infiltration at a microscopic level, appearing as hypo-intense T2w -signal, but not observed by autopsy. Findings from cardiovascular MTR imaging corresponded to histology results. In contrast to T2w -imaging, MTR imaging discriminated between normal myocardium, scar tissue and regions of acute myocardial infarction in all three cases. J. Magn. Reson. Imaging 2013. © 2013 Wiley Periodicals, Inc.
Resumo:
PURPOSE To gain a deeper understanding of the influence of skeletal muscle fiber orientation on metabolite visibility, magnetization transfer from water, and water proton relaxation rates in (1) H MR spectra. METHODS Non-water-suppressed MR spectroscopy was performed in tibialis anterior muscle (TA) of 10 healthy adults, with the TA oriented either parallel or at the magic angle to the 3T field. Spectra were acquired with metabolite-cycled PRESS, and water inversion from 50 to 2510 ms before excitation. Water proton T2 relaxation was sampled with STEAM with echo times from 12 to 272 ms. RESULTS Apparent concentrations of total creatine (tCr), taurine, and trimethylammonium compounds were reduced by 29% to 67% when TA was parallel to B0 . Both tCr peak areas were strongly correlated to the methylene peak splitting. Magnetization transfer rates from water to tCr CH3 were not significantly different between orientations. Water T1 s were similar between orientations, but T2 s were statistically significantly shorter by 1 ms in the parallel orientation (P = 0.002). CONCLUSION Muscle metabolite visibilities in MR spectroscopy and water T2 times depend substantially on muscle fiber orientation relative to B0 . In contrast, magnetization transfer rates appear to depend on muscle composition, rather than fiber orientation. Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.
Resumo:
Using quantum Monte Carlo, we study the nonequilibrium transport of magnetization in large open strongly correlated quantum spin-12 systems driven by purely dissipative processes that conserve the uniform or staggered magnetization, disregarding unitary Hamiltonian dynamics. We prepare both a low-temperature Heisenberg ferromagnet and an antiferromagnet in two parts of the system that are initially isolated from each other. We then bring the two subsystems in contact and study their real-time dissipative dynamics for different geometries. The flow of the uniform or staggered magnetization from one part of the system to the other is described by a diffusion equation that can be derived analytically.
Resumo:
Purpose To investigate whether nonhemodynamic resonant saturation effects can be detected in patients with focal epilepsy by using a phase-cycled stimulus-induced rotary saturation (PC-SIRS) approach with spin-lock (SL) preparation and whether they colocalize with the seizure onset zone and surface interictal epileptiform discharges (IED). Materials and Methods The study was approved by the local ethics committee, and all subjects gave written informed consent. Eight patients with focal epilepsy undergoing presurgical surface and intracranial electroencephalography (EEG) underwent magnetic resonance (MR) imaging at 3 T with a whole-brain PC-SIRS imaging sequence with alternating SL-on and SL-off and two-dimensional echo-planar readout. The power of the SL radiofrequency pulse was set to 120 Hz to sensitize the sequence to high gamma oscillations present in epileptogenic tissue. Phase cycling was applied to capture distributed current orientations. Voxel-wise subtraction of SL-off from SL-on images enabled the separation of T2* effects from rotary saturation effects. The topography of PC-SIRS effects was compared with the seizure onset zone at intracranial EEG and with surface IED-related potentials. Bayesian statistics were used to test whether prior PC-SIRS information could improve IED source reconstruction. Results Nonhemodynamic resonant saturation effects ipsilateral to the seizure onset zone were detected in six of eight patients (concordance rate, 0.75; 95% confidence interval: 0.40, 0.94) by means of the PC-SIRS technique. They were concordant with IED surface negativity in seven of eight patients (0.88; 95% confidence interval: 0.51, 1.00). Including PC-SIRS as prior information improved the evidence of the standard EEG source models compared with the use of uninformed reconstructions (exceedance probability, 0.77 vs 0.12; Wilcoxon test of model evidence, P < .05). Nonhemodynamic resonant saturation effects resolved in patients with favorable postsurgical outcomes, but persisted in patients with postsurgical seizure recurrence. Conclusion Nonhemodynamic resonant saturation effects are detectable during interictal periods with the PC-SIRS approach in patients with epilepsy. The method may be useful for MR imaging-based detection of neuronal currents in a clinical environment. (©) RSNA, 2016 Online supplemental material is available for this article.
Resumo:
Changes in the dissolved oxygen content, the alkalinity, and the pH in sea water near the ocean floor are interpreted in terms of chemical and biochemical processes at the sediment water interface. A simple model provides a plausible explanation of the observed phenomena. Special emphasis is given to the importance of borate corrections in the calculation of the solution effects of calcium carbonate.
Resumo:
Detailed paleomagnetic investigations are reported for 283 specimens, sampled from three closely spaced Ocean Drilling Program Leg 135 cores from the Lau Basin. These specimens cover three rather similar records of the reversed Cobb Mountain short polarity event, having an age of about 1.12 m.y. On the basis of a very detailed subsampling every 0.6 cm, we found that the transition times for the Cobb Mountain geomagnetic polarity event, as seen in the three Lau Basin sediment records, appear to have been as short as 0.6-1.0 k.y., although the duration of the normal-polarity event itself lasted only about 17 ± 4 k.y. The older (R to N) transition as well as the younger (N to R) transition show virtual geomagnetic paths roughly along the Americas, but shifted some 30° ± 10° to the east. These paths conflict with Cobb Mountain transition paths recorded in sediments from the Labrador Sea and the North Atlantic, but they are in fair accordance with sediment records from the Celebes and Sulu seas when corrected for differences in site longitude, suggesting that the transitional fields are dominated by nonaxial, high-order spherical harmonics.