993 resultados para rotary instrumentation
Resumo:
Recent advances in signal analysis have engendered EEG with the status of a true brain mapping and brain imaging method capable of providing spatio-temporal information regarding brain (dys)function. Because of the increasing interest in the temporal dynamics of brain networks, and because of the straightforward compatibility of the EEG with other brain imaging techniques, EEG is increasingly used in the neuroimaging community. However, the full capability of EEG is highly underestimated. Many combined EEG-fMRI studies use the EEG only as a spike-counter or an oscilloscope. Many cognitive and clinical EEG studies use the EEG still in its traditional way and analyze grapho-elements at certain electrodes and latencies. We here show that this way of using the EEG is not only dangerous because it leads to misinterpretations, but it is also largely ignoring the spatial aspects of the signals. In fact, EEG primarily measures the electric potential field at the scalp surface in the same way as MEG measures the magnetic field. By properly sampling and correctly analyzing this electric field, EEG can provide reliable information about the neuronal activity in the brain and the temporal dynamics of this activity in the millisecond range. This review explains some of these analysis methods and illustrates their potential in clinical and experimental applications.
Resumo:
OBJECTIVE: The aim of this study is to create a standard test to approve the efficacy of a surgical sealant. An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives. METHODS: Samples were composed of two circular layers of equine pericardium glued by the surgical sealant studied. The sample was fixed to a support with an industrial glue. The support and the bottom layer were perforated in the centre to allow injection of pressurised water. Water was progressively introduced through the hole in the support and the bottom layer to create a blister with constant radius, increasing height and internal pressure during this first step. At a critical pressure, delamination started, the radius and height of the blister increased and the pressure decreased. At this point, the adhesion energy could be determined. The experimental parameters were measured with a pressure sensor and an optical profilometry device for deflection. RESULTS: Adhesion testing was carried out in eight paired equine pericardium samples bonded with a Dermabond cyanoacrylate glue. The average value of the practical adhesion energy is 2.3 Jm(-2) with a standard deviation of 1.5 Jm(-2). CONCLUSION: Application of the bulge-and-blister test to the surgical field was achieved and allowed a quantification of adhesion of a surgical glue. Such information is essential to compare the different surgical glues presently available. The study of the impact of bonding conditions such as pressure, hygrometry or setting conditions will provide a better understanding of the characteristics of adhesion in the surgical field.
Resumo:
Acute massive pulmonary embolism (PE) is a life-threatening event. Before the era of cardiopulmonary bypass, acute pulmonary embolectomy had been historically attempted in patients with severe hemodynamic compromise. The Klippel-Trenaunay syndrome (KTS) represents a significant life-long risk for major thromboembolic events. We present two young patients with Klippel-Trenaunay syndrome who survived surgical embolectomy after massive PE and cardiopulmonary resuscitation, with good postoperative recovery. Even though the role of surgical embolectomy in massive PE is not clearly defined, with current technology it can be life saving and can lead to a complete recovery, especially in young patients as described in this study.
Resumo:
The quantity of interest for high-energy photon beam therapy recommended by most dosimetric protocols is the absorbed dose to water. Thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (TPS). However, when measurements are performed in a low-density medium, the presence of the ionization chamber generates a perturbation at the level of the secondary particle range. Therefore, the measured quantity is close to the absorbed dose to a volume of water equivalent to the chamber volume. This quantity is not equivalent to the dose calculated by a TPS, which is the absorbed dose to an infinitesimally small volume of water. This phenomenon can lead to an overestimation of the absorbed dose measured with an ionization chamber of up to 40% in extreme cases. In this paper, we propose a method to calculate correction factors based on the Monte Carlo simulations. These correction factors are obtained by the ratio of the absorbed dose to water in a low-density medium □D(w,Q,V1)(low) averaged over a scoring volume V₁ for a geometry where V₁ is filled with the low-density medium and the absorbed dose to water □D(w,QV2)(low) averaged over a volume V₂ for a geometry where V₂ is filled with water. In the Monte Carlo simulations, □D(w,QV2)(low) is obtained by replacing the volume of the ionization chamber by an equivalent volume of water, according to the definition of the absorbed dose to water. The method is validated in two different configurations which allowed us to study the behavior of this correction factor as a function of depth in phantom, photon beam energy, phantom density and field size.
Resumo:
RAPPORT DE SYNTHÈSE : Chez les patients présentant une pathologie de la colonne cervicale, l'instrumentation des voies aériennes peut s'avérer délicate. En effet, l'impossibilité d'effectuer une extension de la nuque afin d'aligner correctement l'axe oro-pharyngo-trachéal, ainsi que l'ouverture de bouche limitée par la présence d'une minerve cervicale, rendent la laryngoscopie standard extrêmement difficile. Le but de cette étude est de démontrer que l'intubation oro-trachéale avec une minerve cervicale semi-rigide est possible à l'aide d'un vidéolaryngoscope récemment développé, le GlideScope®. Celui-ci est formé d'une lame courbe présentant une angulation accentuée à 60° à partir de son milieu, avec une petite caméra haute résolution et une source lumineuse enchâssées dans la partie inférieure au point d'inflexion. Différents travaux ont montré les avantages du GlideScope® par rapport à la lame de Macintosh standard "pour l'instrumentation des voies aériennes de routine ou en situation difficile. Après acceptation par la Commission d'Ethique, 50 patients, adultes consentants et programmés pour une intervention chirurgicale élective nécessitant une anesthésie générale ont été inclus dans cette étude. Malgré la présence d'une minerve cervicale semi-rigide Philadelphia® Patriot correctement positionnée et la tête fixée à la table d'opération, tous les patients ont pu être intubés a l'aide du GlideScope®. Aucune complication n'a été documentée pendant la procédure ou en post-opératoire. De plus, nous avons démontré que dans cette situation la visualisation des structures laryngées est significativement améliorée grâce au GlideScope®, par rapport à la lame de Macintosh utilisée lors de toute intubation standard. En conclusion, l'intubation oro-trachéale chez les patients ayant une minerve cervicale et la tête fixée est possible à l'aide du GlideScope®. La meilleure façon de sécuriser les voies aériennes chez les patients présentant une instabilité de la colonne cervicale est un sujet fortement débattu. L'utilisation du GlideScope® pourrait s'avérer une alternative intéressante, en particulier dans les situations d'urgence.
Resumo:
The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.
Resumo:
Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.
Resumo:
Anterior spinal infection (prevertebral abscess and/or discitis) after posterior instrumentation for vertebral fractures is a challenging complication, since a new implant may become necessary anteriorly, in a septic environment. Generally accepted management guidelines are yet to be established. The authors present a case of posterior instrumentation for fractures of T12 and L1, complicated after 9 months with an anterior infection (prevertebral abscess and discitis) with extended-spectrum beta-lactamase (ESBL) producing Escherichia coli (E. coli). This case is unique in that the multi-resistant organism was isolated only after the second stage of infection treatment, which consisted of anterior débridement and anterior implantation of titanium cages and rods. In this particular case, infection was controlled despite implantation of multiple cages, screws and rods, and fusion was achieved, by means of intravenous antibiotic treatment for 12 months. At the latest follow-up, 24 months post surgery, there was no evidence of infection. This problem case may be helpful for surgeons confronted with spinal deformities secondary to infections with multi-resistant organisms.
Resumo:
A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.
Resumo:
Le présent cahier documente les différents programmes informatiques nécessaires à l'adaptation suisse des DRG.
Resumo:
The aim of this study was to propose a methodology allowing a detailed characterization of body sit-to-stand/stand-to-sit postural transition. Parameters characterizing the kinematics of the trunk movement during sit-to-stand (Si-St) postural transition were calculated using one initial sensor system fixed on the trunk and a data logger. Dynamic complexity of these postural transitions was estimated by fractal dimension of acceleration-angular velocity plot. We concluded that this method provides a simple and accurate tool for monitoring frail elderly and to objectively evaluate the efficacy of a rehabilitation program.
Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.
Resumo:
OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.
Resumo:
Most patients with symptomatic internal carotid artery occlusion have a single minor or major hemispheric stroke. A minority of patients have ipsilateral retinal ischemia, recurrent strokes, or transient ischemic attacks. Whereas spontaneous carotid recanalization is rare, acute surgical recanalization has been attempted, with mixed results. Recently, acute endovascular recanalization has been performed and described as feasible and relatively safe. We describe a patient with symptom recurrence related to hemodynamic factors after occlusion of the carotid artery who was successfully treated 14 days after symptom onset.
Resumo:
Monitoring of internal exposure for nuclear medicine workers requires frequent measurements due to the short physical half-lives of most radionuclides used in this field. The aim of this study was to develop screening measurements performed at the workplace by local staff using standard laboratory instrumentation, to detect whether potential intake has occurred. Such measurements do not enable to determine the committed effective dose, but are adequate to verify that a given threshold is not exceeded. For radioiodine, i.e. (123)I, (124)I, (125)I and (131)I, a calibrated surface contamination monitor is placed in front of the thyroid to detect whether the activity threshold has been exceeded. For radionuclides with very short physical half-lives (≤6 h), such as (99m)Tc and those used in positron emission tomography imaging, i.e. (11)C, (15)O, (18)F and (68)Ga, screening procedures consist in performing daily measurements of the ambient dose rate in front of the abdomen. Other gamma emitters used for imaging, i.e. (67)Ga, (111)In and (201)Tl, are measured with a scintillation detector located in front of the thorax. For pure beta emitters, i.e. (90)Y and (169)Er, as well as beta emitters with low-intensity gamma rays, i.e. (153)Sm, (177)Lu, (186)Re and (188)Re, the procedure consists in measuring hand contamination immediately after use. In Switzerland, screening procedures have been adopted by most nuclear medicine services since such measurements enable an acceptable monitoring while taking into account practical and economic considerations.
Resumo:
The aim of this experimental study is to evaluate the feasibility and the outcome of total endovascular stent implantation in the aortic arch. Indications for this operation-technique would be acute or chronic dissection of the aortic arch (non-A-non-B dissection) or type B dissection with retrograde extension. Four pigs were canulated via the distal abdominal aorta and a retrograde placement of a Djumbodis arch stent (4-9 cm) was controlled by using intravascular ultrasound and intracardiac ultrasound by the inferior cava vein and under radioscopic control. Cerebral perfusion, by using a flow meter placed on one prepared carotid artery, were controlled before, immediate post-procedural (<1 min), and in the early follow-up after aortic arch stent implantation. During the implantation process, especially during balloon inflation and deflation, mean carotid perfusion decreases slightly. A reactive increase of carotid perfusion after stent placements indicates transitory cerebral hypo-perfusion. Non-covered aortic arch stent implantation is technically feasible and could be a potential treatment option in otherwise inoperable arch dissections. The time required for balloon inflation and deflation causes an important risk of cerebral ischemia. The latter can be reduced by transaxillary perfusion.