832 resultados para pacs: design and graphics it applications


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Switzerland, organ procurement is well organized at the national-level but transplant outcomes have not been systematically monitored so far. Therefore, a novel project, the Swiss Transplant Cohort Study (STCS), was established. The STCS is a prospective multicentre study, designed as a dynamic cohort, which enrolls all solid organ recipients at the national level. The features of the STCS are a flexible patient-case system that allows capturing all transplant scenarios and collection of patient-specific and allograft-specific data. Beyond comprehensive clinical data, specific focus is directed at psychosocial and behavioral factors, infectious disease development, and bio-banking. Between May 2008 and end of 2011, the six Swiss transplant centers recruited 1,677 patients involving 1,721 transplantations, and a total of 1,800 organs implanted in 15 different transplantation scenarios. 10 % of all patients underwent re-transplantation and 3% had a second transplantation, either in the past or during follow-up. 34% of all kidney allografts originated from living donation. Until the end of 2011 we observed 4,385 infection episodes in our patient population. The STCS showed operative capabilities to collect high-quality data and to adequately reflect the complexity of the post-transplantation process. The STCS represents a promising novel project for comparative effectiveness research in transplantation medicine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper analyzes the possibilities of integrating cost information and engineering design. Special emphasis is put on finding the potential of using the activity-based costing (ABC) method. Today, the problem of cost estimation in engineering design is that there are two separate extremes of knowledge. On the one extreme, the engineers model the technical parametres behindcosts in great detail but do not get appropriate cost information to their elegant models. On the other extreme, the accounting professionals are stuck with traditional cost accounting methods driven by the procedures and cycles of financial accounting. Therefore, in many cases, the cost information needs of various decision making groups, for example design engineers, are not served satisfactorily. This paper studies if the activity-based costing (ABC) method could offer a compromise between the two extremes. Recognizing activities and activity chains as well as activity and cost drivers could be specially beneficial for design engineers. Also, recognizing the accurate and reliable product costs of existing products helps when doing variant design. However, ABC is not at its best if the cost system becomes too complicated. This is why a comprehensive ABC-cost information system with detailed cost information for the use of design engineers should be examined critically. ABC is at its best when considering such issues as which activities drive costs, the cost of product complexity, allocating indirect costs on the products, the relationships between processes and costs, and the cost of excess capacity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Self-nanoemulsifying drug delivery systems of gemfibrozil were developed under Quality by Design approach for improvement of dissolution and oral absorption. Preliminary screening was performed to select proper components combination. BoxBehnken experimental design was employed as statistical tool to optimize the formulation variables, X1 (Cremophor® EL), X2 (Capmul® MCM-C8), and X3 (lemon essential oil). Systems were assessed for visual characteristics (emulsification efficacy), turbidity, droplet size, polydispersity index and drug release. Different pH media were also assayed for optimization. Following optimization, the values of formulation components (X1, X2, and X3) were 32.43%, 29.73% and 21.62%, respectively (16.22% of gemfibrozil). Transmission electron microscopy demonstrated spherical droplet morphology. SNEEDS release study was compared to commercial tablets. Optimized SNEDDS formulation of gemfibrozil showed a significant increase in dissolution rate compared to conventional tablets. Both formulations followed Weibull mathematical model release with a significant difference in td parameter in favor of the SNEDDS. Equally amodelistic parameters were calculated being the dissolution efficiency significantly higher for SNEDDS, confirming that the developed SNEDDS formulation was superior to commercial formulation with respect to in vitro dissolution profile. This paper provides an overview of the SNEDDS of the gemfibrozil as a promising alternative to improve oral absorption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tässä diplomityössä perehdytään WAP:in Push -viitekehykseen. WAP-standardit määrittelevät kuinka Internet-tyyppisiä palveluita, joita voidaan käyttää erilaisia mobiileja päätelaiteitteita käyttäen, toteutetaan tehokkaalla ja verkkoteknologiasta riippumattomalla tavalla. WAP pohjautuu Internet:iin, mutta huomioi pienten päätelaitteiden ja mobiiliverkkojen rajoitukset ja erikoisominaisuudet. WAP Push viitekehys määrittelee verkon aloittaman palvelusisällön toimittamisen. Työn teoriaosassa käydään läpi yleinen WAP-arkkitehtuuri ja WAP-protokollapino käyttäen vertailukohtina lanka-Internetin arkkitehtuuria ja protokollapinoa. Edellistä perustana käyttäen tutustaan WAP Push -viitekehykseen. Käytännönosassa kuvataan WAP Push -välityspalvelimen suunnittelu ja kehitystyö. WAP Push -välityspalvelin on keskeinen verkkoelementti WAP Push -viitekehyksessä. WAP Push -välityspalvelin yhdistää Internetin ja mobiiliverkon tavalla, joka piilottaa teknologiaeroavaisuudet Internetissä olevalta palveluntuottajalta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The networking and digitalization of audio equipment has created a need for control protocols. These protocols offer new services to customers and ensure that the equipment operates correctly. The control protocols used in the computer networks are not directly applicable since embedded systems have resource and cost limitations. In this master's thesis the design and implementation of new loudspeaker control network protocols are presented. The protocol stack was required to be reliable, have short response times, configure the network automatically and support the dynamic addition and removal of loudspeakers. The implemented protocol stack was also required to be as efficient and lightweight as possible because the network nodes are fairly simple and lack processing power. The protocol stack was thoroughly tested, validated and verified. The protocols were formally described using LOTOS (Language of Temporal Ordering Specifications) and verified using reachability analysis. A prototype of the loudspeaker network was built and used for testing the operation and the performance of the control protocols. The implemented control protocol stack met the design specifications and proved to be highly reliable and efficient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Personalized medicine is a challenging research area in paediatric treatments. Elaborating new paediatric formulations when no commercial forms are available is a common practice in pharmacy laboratories; among these, oral liquid formulations are the most common. But due to the lack of specialized equipment, frequently studies to assure the efficiency and safety of the final medicine cannot be carried out. Thus the purpose of this work was the development, characterization and stability evaluation of two oral formulations of sildenafil for the treatment of neonatal persistent pulmonary hypertension. After the establishment of a standard operating procedure (SOP) and elaboration, the physicochemical stability parameters appearance, pH, particle size, rheological behaviour and drug content of formulations were evaluated at three different temperatures for 90 days. Equally, prediction of long term stability, as well as, microbiological stability was performed. Formulations resulted in a suspension and a solution slightly coloured exhibiting fruity odour. Formulation I (suspension) exhibited the best physicochemical properties including Newtonian behaviour and uniformity of API content above 90% to assure an exact dosification process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Network virtualisation is considerably gaining attentionas a solution to ossification of the Internet. However, thesuccess of network virtualisation will depend in part on how efficientlythe virtual networks utilise substrate network resources.In this paper, we propose a machine learning-based approachto virtual network resource management. We propose to modelthe substrate network as a decentralised system and introducea learning algorithm in each substrate node and substrate link,providing self-organization capabilities. We propose a multiagentlearning algorithm that carries out the substrate network resourcemanagement in a coordinated and decentralised way. The taskof these agents is to use evaluative feedback to learn an optimalpolicy so as to dynamically allocate network resources to virtualnodes and links. The agents ensure that while the virtual networkshave the resources they need at any given time, only the requiredresources are reserved for this purpose. Simulations show thatour dynamic approach significantly improves the virtual networkacceptance ratio and the maximum number of accepted virtualnetwork requests at any time while ensuring that virtual networkquality of service requirements such as packet drop rate andvirtual link delay are not affected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Personalized medicine is a challenging research area in paediatric treatments. Elaborating new paediatric formulations when no commercial forms are available is a common practice in pharmacy laboratories; among these, oral liquid formulations are the most common. But due to the lack of specialized equipment, frequently studies to assure the efficiency and safety of the final medicine cannot be carried out. Thus the purpose of this work was the development, characterization and stability evaluation of two oral formulations of sildenafil for the treatment of neonatal persistent pulmonary hypertension. After the establishment of a standard operating procedure (SOP) and elaboration, the physicochemical stability parameters appearance, pH, particle size, rheological behaviour and drug content of formulations were evaluated at three different temperatures for 90 days. Equally, prediction of long term stability, as well as, microbiological stability was performed. Formulations resulted in a suspension and a solution slightly coloured exhibiting fruity odour. Formulation I (suspension) exhibited the best physicochemical properties including Newtonian behaviour and uniformity of API content above 90% to assure an exact dosification process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influences of the spray-drying parameters and the type of nanoparticles (nanocapsules or nanospheres) on the characteristics of nanoparticle-coated diclofenac-loaded microparticles were investigated by using a factorial design 3². Gastrointestinal tolerance following oral administration in rats was evaluated. Formulations were selected considering the best yields, the best encapsulation efficiencies and the lowest water contents, presenting surfaces completely coated by nanostructures and a decrease in the surface areas in relation to the uncoated core. In vitro drug release demonstrated the influence of the nanoparticle-coating on the dissolution profiles of diclofenac. Nanocapsule-coated microparticles presented a protective effect on the gastrointestinal mucosa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An evaluation of the performance of a continuous flow hydride generator-nebulizer for flame atomic absorption spectrometry was carried out. Optimization of nebulizer gas flow rate, sample acid concentration, sample and tetrahydroborate uptake rates and reductant concentration, on the As and Se absorbance signals was carried out. A hydrogen-argon flame was used. An improvement of the analytical sensitivity relative to the conventional bead nebulizer used in flame AA was obtained (2 (As) and 4.8 (Se) µg L-1). Detection limits (3σb) of 1 (As) and 1.3 (Se) µg L-1 were obtained. Accuracy of the method was checked by analyzing an oyster tissue reference material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Depression is a major cause of disability and disease with significant costs to the health system and for the whole society. Regarding the treatment, in recent years has questioned the effectiveness of antidepressant drugs, with a recognition that although depressive disorders tend to improve with these treatments, residual symptoms seems to be still the norm, which is associated with the risk of new episodes or relapses, and faster its appearance. Otherwise many of the specialized clinical guidelines, propose a based on stepped-care model intervention, prioritizing less intrusive actions, including low-intensity psychosocial-interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acetylation was performed to reduce the polarity of wood and increase its compatibility with polymer matrices for the production of composites. These reactions were performed first as a function of acetic acid and anhydride concentration in a mixture catalyzed by sulfuric acid. A concentration of 50%/50% (v/v) of acetic acid and anhydride was found to produced the highest conversion rate between the functional groups. After these reactions, the kinetics were investigated by varying times and temperatures using a 3² factorial design, and showed time was the most relevant parameter in determining the conversion of hydroxyl into carbonyl groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Broadcasting systems are networks where the transmission is received by several terminals. Generally broadcast receivers are passive devices in the network, meaning that they do not interact with the transmitter. Providing a certain Quality of Service (QoS) for the receivers in heterogeneous reception environment with no feedback is not an easy task. Forward error control coding can be used for protection against transmission errors to enhance the QoS for broadcast services. For good performance in terrestrial wireless networks, diversity should be utilized. The diversity is utilized by application of interleaving together with the forward error correction codes. In this dissertation the design and analysis of forward error control and control signalling for providing QoS in wireless broadcasting systems are studied. Control signaling is used in broadcasting networks to give the receiver necessary information on how to connect to the network itself and how to receive the services that are being transmitted. Usually control signalling is considered to be transmitted through a dedicated path in the systems. Therefore, the relationship of the signaling and service data paths should be considered early in the design phase. Modeling and simulations are used in the case studies of this dissertation to study this relationship. This dissertation begins with a survey on the broadcasting environment and mechanisms for providing QoS therein. Then case studies present analysis and design of such mechanisms in real systems. The mechanisms for providing QoS considering signaling and service data paths and their relationship at the DVB-H link layer are analyzed as the first case study. In particular the performance of different service data decoding mechanisms and optimal signaling transmission parameter selection are presented. The second case study investigates the design of signaling and service data paths for the more modern DVB-T2 physical layer. Furthermore, by comparing the performances of the signaling and service data paths by simulations, configuration guidelines for the DVB-T2 physical layer signaling are given. The presented guidelines can prove useful when configuring DVB-T2 transmission networks. Finally, recommendations for the design of data and signalling paths are given based on findings from the case studies. The requirements for the signaling design should be derived from the requirements for the main services. Generally, these requirements for signaling should be more demanding as the signaling is the enabler for service reception.