974 resultados para modified replacement cost
Resumo:
El projecte es planteja el repte de cobrir un forat en l’oferta turística seguint la fórmula low cost: el guiatge turístic. La idea de la empresa que volem estudiar i crear (BREAKGUIDES) és la de poder oferir els serveis de guiatge, ja siguin guies correu o guies locals en destinació, seguint una fórmula low cost que s’adapti al nou perfil de turista i al seu pressupost. L’empresa tindrà un perfil semblant al d’una xarxa social que ofereixi serveis de guiatge a canvi d’un petit sou i la manutenció
Resumo:
The Andalusian Public Health System Virtual Library (Biblioteca Virtual del Sistema Sanitario Público de Andalucía, BV-SSPA), was created in June 2006. In this paper an evaluation is made to see whether the investment made by the Andalusian Government has been worthwhile. The cost-effectiveness and efficiency of the project together with the management criteria are explored.
Resumo:
BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
BACKGROUND: Enhanced recovery protocols may reduce postoperative complications and length of hospital stay. However, the implementation of these protocols requires time and financial investment. This study evaluated the cost-effectiveness of enhanced recovery implementation. METHODS: The first 50 consecutive patients treated during implementation of an enhanced recovery programme were compared with 50 consecutive patients treated in the year before its introduction. The enhanced recovery protocol principally implemented preoperative counselling, reduced preoperative fasting, preoperative carbohydrate loading, avoidance of premedication, optimized fluid balance, standardized postoperative analgesia, use of a no-drain policy, as well as early nutrition and mobilization. Length of stay, readmissions and complications within 30 days were compared. A cost-minimization analysis was performed. RESULTS: Hospital stay was significantly shorter in the enhanced recovery group: median 7 (interquartile range 5-12) versus 10 (7-18) days (P = 0·003); two patients were readmitted in each group. The rate of severe complications was lower in the enhanced recovery group (12 versus 20 per cent), but there was no difference in overall morbidity. The mean saving per patient in the enhanced recovery group was euro1651. CONCLUSION: Enhanced recovery is cost-effective, with savings evident even in the initial implementation period.
Resumo:
INTRODUCTION Associations of hormone-receptor positive breast cancer with excess adiposity are reasonably well characterized; however, uncertainty remains regarding the association of body mass index (BMI) with hormone-receptor negative malignancies, and possible interactions by hormone replacement therapy (HRT) use. METHODS Within the European EPIC cohort, Cox proportional hazards models were used to describe the relationship of BMI, waist and hip circumferences with risk of estrogen-receptor (ER) negative and progesterone-receptor (PR) negative (n = 1,021) and ER+PR+ (n = 3,586) breast tumors within five-year age bands. Among postmenopausal women, the joint effects of BMI and HRT use were analyzed. RESULTS For risk of ER-PR- tumors, there was no association of BMI across the age bands. However, when analyses were restricted to postmenopausal HRT never users, a positive risk association with BMI (third versus first tertile HR = 1.47 (1.01 to 2.15)) was observed. BMI was inversely associated with ER+PR+ tumors among women aged ≤49 years (per 5 kg/m2 increase, HR = 0.79 (95%CI 0.68 to 0.91)), and positively associated with risk among women ≥65 years (HR = 1.25 (1.16 to 1.34)). Adjusting for BMI, waist and hip circumferences showed no further associations with risks of breast cancer subtypes. Current use of HRT was significantly associated with an increased risk of receptor-negative (HRT current use compared to HRT never use HR: 1.30 (1.05 to 1.62)) and positive tumors (HR: 1.74 (1.56 to 1.95)), although this risk increase was weaker for ER-PR- disease (Phet = 0.035). The association of HRT was significantly stronger in the leaner women (BMI ≤22.5 kg/m2) than for more overweight women (BMI ≥25.9 kg/m2) for, both, ER-PR- (HR: 1.74 (1.15 to 2.63)) and ER+PR+ (HR: 2.33 (1.84 to 2.92)) breast cancer and was not restricted to any particular HRT regime. CONCLUSIONS An elevated BMI may be positively associated with risk of ER-PR- tumors among postmenopausal women who never used HRT. Furthermore, postmenopausal HRT users were at an increased risk of ER-PR- as well as ER+PR+ tumors, especially among leaner women. For hormone-receptor positive tumors, but not for hormone-receptor negative tumors, our study confirms an inverse association of risk with BMI among young women of premenopausal age. Our data provide evidence for a possible role of sex hormones in the etiology of hormone-receptor negative tumors.
Resumo:
OBJECTIVE: To estimate the incremental cost-effectiveness of the first-line pharmacotherapies (nicotine gum, patch, spray, inhaler, and bupropion) for smoking cessation across six Western countries-Canada, France, Spain, Switzerland, the United States, and the United Kingdom. DESIGN AND STUDY POPULATION: A Markov-chain cohort model to simulate two cohorts of smokers: (1) a reference cohort given brief cessation counselling by a general practitioner (GP); (2) a treatment cohort given counselling plus pharmacotherapy. Effectiveness expressed as odds ratios for quitting associated with pharmacotherapies. Costs based on the additional physician time required and retail prices of the medications. INTERVENTIONS: Addition of each first-line pharmacotherapy to GP cessation counselling. MAIN OUTCOME MEASURES: Cost per life-year saved associated with pharmacotherapies. RESULTS: The cost per life-year saved for counselling only ranged from US190 dollars in Spain to 773 dollars in the UK for men, and from 288 dollars in Spain to 1168 dollars in the UK for women. The incremental cost per life-year saved for gum ranged from 2230 dollars for men in Spain to 7643 dollars for women in the US; for patch from 1758 dollars for men in Spain to 5131 dollars for women in the UK; for spray from 1935 dollars for men in Spain to 7969 dollars for women in the US; for inhaler from 3480 dollars for men in Switzerland to 8700 dollars for women in France; and for bupropion from 792 dollars for men in Canada to 2922 dollars for women in the US. In sensitivity analysis, changes in discount rate, treatment effectiveness, and natural quit rate had the strongest influences on cost-effectiveness. CONCLUSIONS: The cost-effectiveness of the pharmacotherapies varied significantly across the six study countries, however, in each case, the results would be considered favourable as compared to other common preventive pharmacotherapies.
Resumo:
Thèse (Méd.) - Université de Lausanne, 1986. - Bibliographie p. 111-121
Resumo:
BACKGROUND: The objective of the present study was to compare current results of prosthetic valve replacement following acute infective native valve endocarditis (NVE) with that of prosthetic valve endocarditis (PVE). Prosthetic valve replacement is often necessary for acute infective endocarditis. Although valve repair and homografts have been associated with excellent outcome, homograft availability and the importance of valvular destruction often dictate prosthetic valve replacement in patients with acute bacterial endocarditis. METHODS: A retrospective analysis of the experience with prosthetic valve replacement following acute NVE and PVE between 1988 and 1998 was performed at the Montreal Heart Institute. RESULTS: Seventy-seven patients (57 men and 20 women, mean age 48 +/- 16 years) with acute infective endocarditis underwent valve replacement. Fifty patients had NVE and 27 had PVE. Four patients (8%) with NVE died within 30 days of operation and there were no hospital deaths in patients with PVE. Survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 70% +/- 9%, 59% +/- 10%, and 55% +/- 10% for PVE, respectively (p = 0.15). Reoperation-free survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 45% +/- 10%, 40% +/- 10%, and 36% +/- 9% for PVE (p = 0.003). Five-year survival for NVE averaged 75% +/- 9% following aortic valve replacement and 79% +/- 9% following mitral valve replacement. Five-year survival for PVE averaged 66% +/- 12% following aortic valve replacement and 43% +/- 19% following mitral valve replacement (p = 0.75). Nine patients underwent reoperation during follow-up: indications were prosthesis infection in 4 patients (3 mitral, 1 aortic), dehiscence of mitral prosthesis in 3, and dehiscence of aortic prosthesis in 2. CONCLUSIONS: Prosthetic valve replacement for NVE resulted in good long-term patient survival with a minimal risk of reoperation compared with patients who underwent valve replacement for PVE. In patients with PVE, those who needed reoperation had recurrent endocarditis or noninfectious periprosthetic dehiscence.
Resumo:
In Brazil, carbapenem-resistant Pseudomonas aeruginosa isolates are closely related to the São Paulo metallo-β-lactamase (SPM) Brazilian clone. In this study, imipenem-resistant isolates were divided in two sets, 2002/2003 and 2008/2009, analysed by pulsed field gel electrophoresis and tested for the Ambler class B metallo-β-lactamase (MBL) genes blaSPM-1, blaIMP and blaVIM. The results show a prevalence of one clone related to the SPM Brazilian clone in 2002/2003. In 2008/2009, P. aeruginosa isolates were mostly MBL negative, genetically diverse and unrelated to those that had been detected earlier. These findings suggest that the resistance to carbapenems by these recent P. aeruginosa isolates was not due to the spread of MBL-positive SPM-related clones, as often observed in Brazilian hospitals.
Resumo:
A fluorimetric microassay that uses a redox dye to determine the viability of the flagellate Trichomonas vaginalis has been optimised to provide a more sensitive method to evaluate potential trichomonacidal compounds. Resazurin has been used in recent years to test drugs against different parasites, including trichomonadid protozoa; however, the reproducibility of these resazurin-based methods in our laboratory has been limited because the flagellate culture medium spontaneously reduces the resazurin. The objective of this work was to refine the fluorimetric microassay method previously developed by other research groups to reduce the fluorescence background generated by the media and increase the sensitivity of the screening assay. The experimental conditions, time of incubation, resazurin concentration and media used in the microtitre plates were adjusted. Different drug sensitivity studies against T. vaginalis were developed using the 5-nitroimidazole reference drugs, new 5-nitroindazolinones and 5-nitroindazole synthetic derivatives. Haemocytometer count results were compared with the resazurin assay using a 10% solution of 3 mM resazurin dissolved in phosphate buffered saline with glucose (1 mg/mL). The fluorimetric assay and the haemocytometer counts resulted in similar percentages of trichomonacidal activity in all the experiments, demonstrating that the fluorimetric microtitre assay has the necessary accuracy for high-throughput screening of new drugs against T. vaginalis.
Resumo:
OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.
Resumo:
Dengue fever is the most important arbovirus infection found in tropical regions around the world. Dispersal of the vector and an increase in migratory flow between countries have led to large epidemics and severe clinical outcomes, such as dengue haemorrhagic fever and dengue shock syndrome. This study analysed the genetic variability of the dengue virus serotype 1 (DENV-1) in Brazil with regard to the full-length structural genes C/prM/M/E among 34 strains isolated during epidemics that occurred in the country between 1994-2011. Virus phylogeny and time of divergence were also evaluated with only the E gene of the strains isolated from 1994-2008. An analysis of amino acid differences between these strains and the French Guiana strain (FGA/89) revealed the presence of important nonsynonymous substitutions in the amino acid sequences, including residues E297 (Met→Thr) and E338 (Ser→Leu). A phylogenetic analysis of E proteins comparing the studied isolates and other strains selected from the GenBank database showed that the Brazilian DENV-1 strains since 1982 belonged to genotype V. This analysis also showed that different introductions of strains from the 1990s represented lineage replacement, with the identification of three lineages that cluster all isolates from the Americas. An analysis of the divergence time of DENV-1 indicated that the lineage circulating in Brazil emerged from an ancestral lineage that originated approximately 44.35 years ago.
Resumo:
Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien? XT stent-valve implantation through the fibrotic thin akinetic apical wall.
Resumo:
Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.
Resumo:
Schistosomiasis diagnosis is based on the detection of eggs in the faeces, which is laborious and lacks sensitivity, especially for patients with a low parasite burden. Immunological assays for specific antibody detection are available, but they usually demonstrate low sensitivity and/or specificity. In this study, two simple immunological assays were evaluated for the detection of soluble Schistosoma mansoni adult worm preparation (SWAP) and egg-specific IgGs. These studies have not yet been evaluated for patients with low parasite burdens. Residents of an endemic area in Brazil donated sera and faecal samples for our study. The patients were initially diagnosed by a rigorous Kato-Katz analysis of 18 thick smears from four different stool samples. The ELISA-SWAP was successful for human diagnosis with 90% sensitivity and specificity, confirming the Kato-Katz diagnosis with nearly perfect agreement, as seen by the Kappa index (0.85). Although the ELISA-soluble S. mansoni egg antigen was 85% sensitive, it exhibited low specificity (80%; Kappa index: 0.75) and was more susceptible to cross-reactivity. We believe that immunological assays should be used in conjunction with Kato-Katz analysis as a supplementary tool for the diagnosis of schistosomiasis for patients with low infection burdens, which are usually hard to detect.