921 resultados para denaturing high-performance liquid chromatography (DHPLC) sequencing
Resumo:
The susceptibility of Drosophila melanogaster to carbofuran and the use of this organism in biomonitoring residues of the insecticide in cabbage was evaluated. Under the conditions of the bioassay, residues-film bioassay in Petri dish, carbofuran degraded depending on the temperature and time of exposure. Bioassays conducted with D. melanogaster showed that its toxicity increases with temperature (20 to 35 °C). LC50 values, calculated as a function of temperature, ranged from 3.6 to 10.5 mg/g body weight (bw) for males and from 2.9 to 8.7 mg/g bw for females. The formulated product Furadan® G was applied on cabbage (Brassica oleracea, var. capitata) and the residues of carbofuran were determined by bioassay. The determination limit of the bioassay was 0.1 mg/kg and the method presented reproducibility with coefficient variation of 17 %. The validation of the bioassay by high performance liquid chromatography confirms the viability of the bioassay with D. melanogaster in monitoring the residues of carbofuran in cabbage.
Resumo:
The genus Plumbago belongs to the family Plumbaginaceae, order Plumbaginales. Comparative chemical profile of P. scandens (native) and P. auriculata (cultivated) was obtained by normal and reversed-phase high performance liquid chromatography with photodiode array detector. Comparison of the ultraviolet espectra and the retention times for the compounds allowed to find similar metabolic patterns in roots, stems and leaves. Four flavonoids, one phenolic acid or derivative and the naphtoquinone plumbagin were comparatively identified to standards.
Resumo:
The effects of 60Co ionizing radiations in doses of 0, 75, 100, 150, 200 and 250Gy on garlic, upon the alpha-tocopherol concentration were studied. The alpha-tocopherol contents were established by high performance liquid chromatography (HPLC), after direct hexane extraction from the garlic samples. The alpha-tocopherol was determined through normal-phase column, and mobile phase was composed by hexane: iso-propyl alcohol (99:01 v/v), with 2mL/min flow rate and fluorescence detector. It is statistically shown that an irradiation dose of up to 150 Gy does not affect the garlic alpha-tocopherol content.
Resumo:
Synthetic dyes were determined by high performance liquid chromatography in 76 samples of regular jelly and diet jelly powders, of several flavors produced by seven different manufacturers. Three sample of each product, from different batches, were analyzed. The same qualitative composition was observed for products of the same flavor from different manufacturers, but the quantitative composition varied markedly from one manufacturer to the other. There were no or few significant differences between batches from a given manufacturer, demonstrating good quality control in the use of these additives by the food industry. None of the samples exceeded the limit stipulated by Brazilian legislation.
Resumo:
This paper presents the study of adsorption/desorption of the explosive tetryl (2,4,6-trinitrophenylmethyl-nitramine) in different matrices, such as in natura soil, roasted soil, humic acid of soil, in natura peat, roasted peat and humic acid of peat. The aim of the study is to evaluate the interaction capacity of those matrices with the explosive. The analytic technique used was HPLC (high performance liquid chromatography), with UV-detection at 230 nm. The Freundlich isotherms were utilized for the mathematical treatment of the data. The results indicated that in natura soil and in natura peat (with organic substances) are excellent matrices for the retention of tetryl, adsorbing it and keeping it immovable, preventing it from contaminating the groundwater. The largest adsorption of the explosive ocurred in in natura soil, while the smallest desorption was observed in in natura peat. After the calcination of the matrices, the smallest adsorption was observed, indicating that the retention occurs in the organic substance.
Resumo:
Bisphosphonates are drugs that have been widely used in different bone diseases, and have recently been used successfully against many parasites. Various synthetic routes to prepare different types of bisphosphonates have been described, with distinct potency and pharmacological activity. A number of analytical techniques are currently being used to analyze these drugs; among these, the high performance liquid chromatography (HPLC), with different systems of detection, is worth highlighting. However, the development of more sensitive methods is still necessary, once they are essential for bioavailability and bioequivalence studies. This paper reports the major synthesis routes, chemical analysis methodologies and pharmacological applications of bisphosphonates.
Resumo:
This work presents an alternative method for determination of the herbicides tebuthiuron and hexazinone in ground water. The extraction was made with dichloromethane and the analyses by high performance liquid chromatography (HPLC), using reversed-phase column, C-18, mobile phase methanol/water 50:50, v/v, detection and quantification at 247 nm. The following validation parameters were obtained: limit of detection of method 0.02 and 0.03 µg L-1, limit of quantification of method 0.07 and 0.09 µg L-1; linear range limit of quantification of instrument - 300 µg L-1 (r² > 0.998); recoveries from 90.3 to 108.2% and 90.3 to 101.6%; intermediary precision (%RSD) < 8 and < 6%, for hexazinone and tebuthiuron, respectively. The method showed to be efficient and reliable for determination of the herbicides in ground water.
Resumo:
Maltodextrin was produced from cassava and corn starch by enzymatic hydrolysis with alpha-amylase. The cassava starch hydrolysis rate was higher than that of corn starches in maltodextrin production with shorter dextrose equivalent (DE). DE values do not show directly the nature of the obtained oligosaccharides. Maltodextrin produced from cassava and corn starch was analysed by high performance liquid chromatography (HPLC), and the analysis showed that maltodextrin production differs according to the source of the starch. This is important in defining the application of the maltodextrin, according to its desired function.
Resumo:
The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.
Resumo:
A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.
Resumo:
Monolithic stationary phases represent a new generation of chromatographic separation media. These phases consist of a continuous separation bed prepared by in situ polymerization or consolidation inside the column tubing. In recent years, their simple preparation procedure, unique properties and excellent performance have attracted quite remarkable attention in liquid chromatography and capillary electrochromatography. This review summarizes the preparation, characterization and applications of monolithic stationary phases. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different separation modes.
Resumo:
A high performance liquid chromatography method was developed to quantify lamivudine, stavudine and nevirapine combined in tablets. The separation was carried out in less than 10 min using a phosphate buffer of pH 3.0 and acetonitrile (75:25, v/v) as mobile phase, a LiChrospher ODS column and UV detection at 266 nm. The method was linear over the range of 15-135 µg/mL (lamivudine), 4-36 µg/mL (stavudine) and 20-180 µg/mL (nevirapine). The accuracy ranged from 98.56 to 102.04% and intra-day and inter-day precision was less than 1% for the three drugs. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.
Resumo:
Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.
Resumo:
Paclobutrazol is a plant growth retardant which is used world-wide for increasing the yield of cereal crops. However, this compound remains active in the soil for several years and can severely affect the growth and development of subsequent crops, mainly by reducing vegetative vigor. The aim of this work was to develop and validate methods for the determination of paclobutrazol concentrations by both high performance liquid chromatography and spectroscopy. Both methods were satisfactory and showed appropriately low quantification limits. The determination by spectroscopy has, however, the advantage of being a method significantly less expensive than high performance liquid chromatography.
Resumo:
Itraconazole is a synthetic antifungal drug administered orally with a broad spectrum of activity against mycotic infections. The present work consists of the development and validation of analytical methodology for evaluation of itraconazole in pharmaceutical products by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/diethylamine 0.05% v/v, 60:40 v/v, pH 8.0 as mobile phase, methanol as solvent and detection and quantification at 254 nm. The results here obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 8.0-12.0 µg/mL of itraconazole. The method was applied to pharmaceutical capsules containg itraconazole pellets and showed to be efficient, yielding good results.