955 resultados para critical cooling rate


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reexamined the association between speech rate and memory span in children from kindergarten to sixth grade (N = 152) in order to potentially account for the inconsistencies within the published literature on this topic. Some of the inconsistencies in past research may reflect the different methods adopted in assessing speech rate. In particular, repeating word triples may itself involve memory demands, contaminating the correlation between speech rate and memory span in younger children. Analyses using composite speech rate and memory span measures showed that speech rate for word triples shared variance with memory span that was independent of speech rate for single words. Moreover, speech rate for word triples was largely redundant with age in explaining additional variation in memory span once the effects of speech rate for single words were controlled. (C) 2002 Elsevier Science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complex chemical reactions in the gas phase can be decomposed into a network of elementary (e.g., unimolecular and bimolecular) steps which may involve multiple reactant channels, multiple intermediates, and multiple products. The modeling of such reactions involves describing the molecular species and their transformation by reaction at a detailed level. Here we focus on a detailed modeling of the C(P-3)+allene (C3H4) reaction, for which molecular beam experiments and theoretical calculations have previously been performed. In our previous calculations, product branching ratios for a nonrotating isomerizing unimolecular system were predicted. We extend the previous calculations to predict absolute unimolecular rate coefficients and branching ratios using microcanonical variational transition state theory (mu-VTST) with full energy and angular momentum resolution. Our calculation of the initial capture rate is facilitated by systematic ab initio potential energy surface calculations that describe the interaction potential between carbon and allene as a function of the angle of attack. Furthermore, the chemical kinetic scheme is enhanced to explicitly treat the entrance channels in terms of a predicted overall input flux and also to allow for the possibility of redissociation via the entrance channels. Thus, the computation of total bimolecular reaction rates and partial capture rates is now possible. (C) 2002 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the skeletal muscle cell at the onset of muscular contraction, phosphocreatine (PCr) represents the most immediate reserve for the rephosphorylation of adenosine triphosphate (ATP). As a result, its concentration can be reduced to less than 30% of resting levels during intense exercise. As a fall in the level of PCr appears to adversely affect muscle contraction, and therefore power output in a subsequent bout, maximising the rate of PCr resynthesis during a brief recovery period will be of benefit to an athlete involved in activities which demand intermittent exercise. Although this resynthesis process simply involves the rephosphorylation of creatine by aerobically produced ATP (with the release of protons), it has both a fast and slow component, each proceeding at a rate that is controlled by different components of the creatine kinase equilibrium. The initial fast phase appears to proceed at a rate independent of muscle pH. Instead, its rate appears to be controlled by adenosine diphosphate (ADP) levels; either directly through its free cytosolic concentration, or indirectly, through its effect on the free energy of ATP hydrolysis. Once this fast phase of recovery is complete, there is a secondary slower phase that appears almost certainly rate-dependant on the return of the muscle cell to homeostatic intracellular pH. Given the importance of oxidative phosphorylation in this resynthesis process, those individuals with an elevated aerobic power should be able to resynthesise PCr at a more rapid rate than their sedentary counterparts. However, results from studies that have used phosphorus nuclear magnetic resonance (P-31-NMR) spectroscopy, have been somewhat inconsistent with respect to the relationship between aerobic power and PCr recovery following intense exercise. Because of the methodological constraints that appear to have limited a number of these studies, further research in this area is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is currently unclear whether it is the need to maintain metabolic efficiency, the need to keep skeletal loading below critical force levels, or simple mechanical factors that drive the walk-to-run (W R) and run-to-walk (R-W) transitions in human gait. Eighteen adults (9 males and 9 females) locomoted on an instrumented treadmill using their preferred gait. Each completed 2 ascending (W-R) and 2 descending (R-W) series of trials under three levels of loading (0%, 15% and 30% body weight). For each trial, participants locomoted for 60 s at each of 9 different speeds -4 speeds both above and below their preferred transition speed (PTS) plus their PTS. Evidence was sought for critical levels of key kinetic (maximum vertical force, impulse, first peak force, time to first peak force and maximum loading rate), energetic (oxygen consumption, transport cost) and mechanical variables (limb lengths, strength) predictive of the gait transition. Analyses suggested the kinetic variables of time to first peak force and loading rate as the most likely determinants of the W-R and R-W transitions. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to determine the mortality rate and the functional outcomes of stroke patients admitted to the intensive care unit (ICU) and to identify predictors of poor outcome in this population. The records of all patients admitted to the ICU with the diagnosis of stroke between January 1994 and December 1999 were reviewed. Patients with subarachnoid haemorrhage were excluded. Data were collected on clinical and biological variables, risk factors for stroke and the presence of comorbidities. Mortality (ICU, in-hospital and three-month) and functional outcome were used as end-points. In the six-year-period, 61 patients were admitted to the ICU with either haemorrhagic or ischaemic stroke. Medical records were available for only 58 patients. There were 23 ischaemic and 35 haemorrhagic strokes. The ICU, in-hospital and three-month mortality rates were 36%, 47% and 52% respectively. There were no significant differences in the prevalence of premorbid risk factors between survivors and non-survivors. The mean Barthel score was significantly different between the independent and dependent survivors (94 +/- 6 vs 45 +/- 26, P < 0.001). A substantial number of patients with good functional outcomes had lower Rankin scores (92% vs 11%, P < 0.001). Only 46% of those who were alive at three months were functionally independent. Intensive care admission was associated with a high mortality rate and a high likelihood of dependent lifestyle after hospital discharge. Haemorrhagic stroke, fixed dilated pupil(s) and GCS < 10 during assessment were associated with increased mortality and poor functional outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passive techniques as an alternative to artificial cooling can bring important energy, environmental, financial, operational and qualitative benefits. However, regions such as the wet tropics can reach high levels of thermal stress in which passive means alone are unable to provide appropriate thermal comfort standards for some parts of the year. Despite a great accumulation of empirical information on the passive performance of houses for either free-running or conditioned modes, very little work has been done on the thermal performance of buildings that can operate with a mixed-running strategy in warm-humid climates. Buildings with such design features are able to balance the needs for comfort, privacy, and energy efficiency during different periods of the year. As free-running and conditioned modes are believed by many to be 'opposite' approaches, and have been presented as separate strategies, this paper demonstrates that not all parameters are directly opposite and a possible dual-mode integrated operation can be used for warm-humid locations for maximum comfort and minimum energy requirements. For this purpose, simulation runs using ESP-R (University of Strathclyde, ESRU, UK) were based on the climate data of Darwin (Australia) and on the ventilation styles of the house: free running and conditioned. Design features applicable to both, i.e. for a dual mode operation could be identified and the differences between conditioned and free running were demonstrated and proved not to be totally conflicting and therefore suitable for a dual mode operation. Different daily usage profiles (five use patterns were defined), and zoning of sleeping and living areas are presented. The dual mode use patterns compared to the base case house, for all the user possibilities, had improved performances of 17-52%, when compared to the free-running mode and 66-98% when compared to the conditioned mode. Simulation runs using other warm-humid climates (Miami, USA; Sao Luis, Brazil; Kuala Lumpur, Malaysia) were also conducted and compared to the results found for Darwin. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors investigated the effect of manual hyperinflation (MHI) with set parameters applied to patients on mechanical ventilation on hemodynamics, respiratory mechanics, and gas exchange. Sixteen critically ill patients post-septic shock, with acute lung injury, were studied. Heart rate, arterial pressure, and mean pulmonary artery pressure were recorded every minute. pulmonary artery occlusion pressure, cardiac output, arterial blood gases, and dynamic compliance (C-dyn) were recorded pre- and post-MHI. From this, systemic vascular resistance index (SVRI), cardiac index, oxygen delivery, and partial pressure of oxygen:fraction of inspired oxygen (PaO2:FiO(2)) ratio were calculated. There were significant increases in SVRI (P < 0.05) post-MHI and diastolic arterial pressure (P < 0.01)during MHI. C-dyn increased post-MHI (P < 0.01) and was sustained at 20 minutes post-MHI (P < 0.01). Subjects with an intrapulmonary cause of lung disease had a significant decrease (P = 0.02) in PaO2:FiO(2), and those with extrapulmonary causes of lung disease had a significant increase (P < 0.001) in PaO2:FiO(2) post-MHI. In critically ill patients, MHI resulted in an improvement in lung mechanics and an improvement in gas exchange in patients with lung disease due to extrapulmonary events and did not result in impairment of the cardiovascular system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of the performance of the APACHE III (Acute Physiology and Chronic Health Evaluation) ICU (intensive care unit) and hospital mortality models at the Princess Alexandra Hospital, Brisbane is reported. Prospective collection of demographic, diagnostic, physiological, laboratory, admission and discharge data of 5681 consecutive eligible admissions (1 January 1995 to 1 January 2000) was conducted at the Princess Alexandra Hospital, a metropolitan Australian tertiary referral medical/surgical adult ICU. ROC (receiver operating characteristic) curve areas for the APACHE III ICU mortality and hospital mortality models demonstrated excellent discrimination. Observed ICU mortality (9.1%) was significantly overestimated by the APACHE III model adjusted for hospital characteristics (10.1%), but did not significantly differ from the prediction of the generic APACHE III model (8.6%). In contrast, observed hospital mortality (14.8%) agreed well with the prediction of the APACHE III model adjusted for hospital characteristics (14.6%), but was significantly underestimated by the unadjusted APACHE III model (13.2%). Calibration curves and goodness-of-fit analysis using Hosmer-Lemeshow statistics, demonstrated that calibration was good with the unadjusted APACHE III ICU mortality model, and the APACHE III hospital mortality model adjusted for hospital characteristics. Post hoc analysis revealed a declining annual SMR (standardized mortality rate) during the study period. This trend was present in each of the non-surgical, emergency and elective surgical diagnostic groups, and the change was temporally related to increased specialist staffing levels. This study demonstrates that the APACHE III model performs well on independent assessment in an Australian hospital. Changes observed in annual SMR using such a validated model support an hypothesis of improved survival outcomes 1995-1999.