1000 resultados para condicionamento térmico
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher
Resumo:
This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Macaíba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential.
Resumo:
The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air
Resumo:
O crescimento da demanda energética, prevista para a metade do século XXI, com números embasados no crescimento demográfico e de consumo dos países em desenvol- vimento, sugere a busca por fontes energéticas renováveis e de menor impacto ao meio ambiente, conforme os tratados da política internacional. Portanto, o fornecimento de energia suplementar se torna vital nas sociedades modernas e sua extensão até o mar tem se constituído uma recente preocupação do ponto de vista enérgico e ecológico. Várias formas de conversão de energia foram desenvolvidas no decorrer dos anos, com destaque para a energia dos gradientes térmicos. A Plataforma Continental Sul do Bra- sil (PSCB) possui alta variabilidade espacial e temporal nos campos de temperatura, de forma que existe a necessidade de uma análise das regiões de maior potencial energético com respeito ao gradiente vertical de temperatura. Neste estudo, foram utilizados dados do modelo OCCAM com uma grade de resolu- ção horizontal de 0, 25o e resolução vertical de 66 níveis, distribuídos ao longo de um sistema de coordenadas vertical. Foram utilizadas imagens de temperatura superfícial do mar (TSM) obtidas a partir do sensor AVHRR (Advanced Very High Resolution Ra- diometer) de forma a realizar a validação dos dados do modelo OCCAM. A análise da média dos dados do modelo indicou um sítio energético de maior viabilidade devido oC ao padrão médio do gradiente térmico de aproximadamente 0, 17 ao longo da coluna vertical (545 m de profundidade) no oceano. Neste local, foram coletados os dados, e aplicados a um módulo de conversão de energia térmica dos oceanos que vem sendo desenvolvido na Universidade Federal do Rio Grande - FURG. A região de estudo de- monstrou possuir um local com ótimo potencial energético, onde a produção máxima de energia pode alcançar 111, 9MW , associada com um padrão variabilidade tempo- ral dominante de 12 meses. Este sítio energético demonstra maior eficiência durante o período de verão e outono ao longo dos anos e sua média para todo o período é de 94, 3MW . Neste estudo, duas correntes: Corrente do Brasil (CB) e a Contra Corrente Costeira (CCC), com águas de origem tropical e subantártica com aportes continentais, respecti- vamente, tem alta correlação com os valores dos gradientes térmicos e com os significa- tivos eventos de conversão energética. O sítio energético demonstrou alta estabilidade à sazonalidade e à gama de eventos meteorológicos e oceanográficos, de forma que pode ser qualificado como uma fonte suplementar a matriz energética do país para um futuro próximo.
Resumo:
This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces
Resumo:
Natural air ventilation is the most import passive strategy to provide thermal comfort in hot and humid climates and a significant low energy strategy. However, the natural ventilated building requires more attention with the architectural design than a conventional building with air conditioning systems, and the results are less reliable. Therefore, this thesis focuses on softwares and methods to predict the natural ventilation performance from the point of view of the architect, with limited resource and knowledge of fluid mechanics. A typical prefabricated building was modelled due to its simplified geometry, low cost and occurrence at the local campus. Firstly, the study emphasized the use of computational fluid dynamics (CFD) software, to simulate the air flow outside and inside the building. A series of approaches were developed to make the simulations possible, compromising the results fidelity. Secondly, the results of CFD simulations were used as the input of an energy tool, to simulate the thermal performance under different rates of air renew. Thirdly, the results of temperature were assessed in terms of thermal comfort. Complementary simulations were carried out to detail the analyses. The results show the potentialities of these tools. However the discussions concerning the simplifications of the approaches, the limitations of the tools and the level of knowledge of the average architect are the major contribution of this study
Resumo:
Projeto de investigação no âmbito da Pós-Graduação em Educação Especial – Domínio Cognitivo e Motor, da Escola Superior de Educação de Paula Frassinetti.
Resumo:
O arroz (Oryza sativa, L.), como todos os cereais, pode ser contaminado por fungos responsáveis por danos tecnológicos, nutricionais e toxicológicos, dentre eles a produção de micotoxinas. Diversas toxinas fúngicas produzidas pelo gênero Fusarium tem sido relatadas em arroz, no entanto a fumonisina B1 (FB1) é pouco estudada neste grão. As principais características da FB1 é a alta solubilidade em solventes polares, estabilidade a altas temperaturas além de efeitos neurotóxicos e carcinogênicos. Assim o objetivo deste trabalho foi avaliar o efeito do tratamento térmico e hidrotérmico nos teores de fumonisina B1 e nas características químicas de arroz comercial. Na primeira etapa do trabalho foi adaptado um método para detecção e quantificação de FB1 em arroz cru e após cocção, por HPLC-FL. O método foi avaliado quanto aos indicativos de eficiência destacando-se o LOD (30 µg.kg-1) e a recuperação ( 90% para arroz cru e 86% pra arroz cozido). Na segunda etapa realizou-se o levantamento de ocorrência de FB1 em 05 diferentes amostras comerciais de arroz integral, branco e parboilizado da cidade de Rio Grande, RS, totalizando 9 amostras. Foi detectada a presença de FB1 em 7 das 9 amostras, sendo que os maiores índices foram encontrados em amostras de arroz parboilizado e integral apresentando níveis de contaminação entre 30 e 170 µg.kg-1. A terceira etapa do trabalho consistiu no estudo do efeito de tratamentos térmicos sobre os níveis de FB1 em amostras após aplicação de calor. Foram testados tratamento hidrotérmico com evaporação, tratamento hidrotérmico com autoclavagem e tratamento térmico seco. O maior nível de redução dos teores iniciais de FB1 foi 82,8% quando se empregou tratamento térmico seco a 125 °C/3 min. Ainda foram avaliados os efeitos do t ratamento hidrotérmico com evaporação de água na composição química e na digestibilidade protéica. Esta característica proporcionou aumento de até 100% na digestibilidade in vitro das proteínas e reduziu em média 73% do teor de contaminação com FB1.
Resumo:
Para avaliar os efeitos de diferentes tempos de pré-condicionamento isquêmico (IPC) em translocação bacteriana intestinal (BT). MÉTODOS: Trinta ratos Wistar pesando 280 ± 27g foram divididos em cinco grupos. No grupo IV (n = 6), a laparotomia foi realizada e a artéria mesentérica superior foi obstruído por um microclampe atraumática durante 30 minutos. Nos quatro grupos de pré-condicionamento (n = 6 cada) antes dos 30 minutos de isquemia-reperfusão (I / R), os ratos foram submetidos a IPC para duas, cinco, dez e 15 minutos, seguido pelo mesmo momento da reperfusão. A fim de avaliar se o tempo de pré-condicionamento influenciaram o surgimento de translocação bacteriana, as amostras de nódulos linfáticos mesentéricos, fígado e baço foram colhidas em condições estéreis, 24 horas após os procedimentos para a quantificação de unidades formadoras de colónias de bactérias por grama de tecido (CFU / g). O sangue foi recolhido para a medição de citoquinas. RESULTADOS: No grupo I / R, o total de CFU / g em gânglios linfáticos mesentéricos, baço, fígado, bem como o soro de TNF-a, IL-1A e IL-6 foram significativamente mais elevados do que nos outros grupos (p <0,05). Pré-condicionamento por 15 minutos significativamente atenuada BT e citocinas séricas quando comparado a outros períodos de pré-condicionamento (p <0,05). CONCLUSÃO: Nossos dados sugerem que o pré-condicionamento como um fator chave para reduzir a translocação bacteriana intestinal em I / R. Numa escala de dois a 15 minutos, o melhor tempo de pré-condicionamento isquémico pela atenuação da translocação bacteriana foi de 15 minutos
Resumo:
The chemical changes in clay minerals has been widely studied in order to improve its properties for use in various applications. However kaolinite has strong hydrogen bonds between their adjacent layers hindering the process changes in its structure. With the objective to facilitate the process of intercalation monobasic potassium phosphate, bibasic potassium phosphate and potassium acetate we was performed on kaolinite heat treatment at 600 °C and activated acidic with phosphoric acid and 5 to 10 mol L-1. The samples they were characterized by energy dispersive spectroscopy (EDS), X-Ray Diffraction (XRD), Infrared Spectroscopy Fourier Transform (FTIR) and Thermogravimetric Analysis (TG) and Differential Thermal Analysis (DTG) and the superficial and textural changes the samples with heat treatment and acid activation they were characterized by scanning electron microscopy (SEM) and Textural Analysis of Adsorption/desorption N2. With the help of the techniques found that, the heat treatment becomes more susceptible to acid activation kaolinite making the samples with two treatments show larger amounts of phosphorus. It was also found that bibasic potassium phosphate binds more strongly the structure of kaolinite by having a structure with two-coordinating oxygens and intercalation with potassium acetate in acid-activated kaolin increases the interlayer distance of the kaolinite and the intercalation occurs with higher response index (RI) for samples with acid activation to 5 mol /L.
Resumo:
Bogotá (Colombia) : Universidad de La Salle. Facultad de Ingeniería. Programa de Ingeniería Ambiental y Sanitaria
Resumo:
Tese (Doutorado em Tecnologia Nuclear)
Resumo:
Titanium is a biomaterial widely employed in biomedical applications (implants, prostheses, valves, stents). Several heat treatments are usually used in order to obtain physical properties required to different applications. This work studied the influence of the heat treatment on microstructure of commercial pure titanium, and their consequences in growth and proliferation of MC3T3-E1 cells. Discs of titanium were treated in different temperatures, and characterized by optical microscopy, image analysis, wettabillity, roughness, hardness and X-ray diffraction. After the heat treatment, significant modifications in these properties were observed. Pattern images of titanium, before and after the cell culture, were compared by overlapping to analyze the influence of microstructure in microstructure and preferences guidance cells. However, in general, titanium discs that showed a higher residual strength also presented an increase of cells numbers on surface
Resumo:
Population growth experienced in major cities, allied to society s need of infra-structure, especially ones related to habitational demands, increases the consumption of construction materials. As a consequence, consumption of natural resources itself. Thus, due to this process, concrete is one of the most produced materials in civil construction. This is also due to the great diversity of its application, easiness in its execution and adequate mechanical performance, as well as low production costs. Following the same tendencies in construction development, the ceramic industry has intensified the production of porcelain ceramic tiles and floors. These are achieved by a fine finishing and receive polishing at the end of the fabrication process. This work researched the use of porcelain residues in polishing for the production of concrete. All of which; due to economical and environmental issues. This process aims to prove adequate destiny for this type of residue, due to environmental issues, incorporating it to the concrete itself; all of which provides economy in consumption of the materials that constitute concrete. Thus, the main characteristics of concrete were investigated through the inclusion of different concentration of the porcelain residue as additional trait element. The residue rates incorporated to the trait varied from 10% to 50% in relation to the cement mass, in the traits with plastic additives and without plastic additives. It is observed that the inclusion of porcelain residue produced a meaningful alteration in the consistency of fresh concrete. This residue has a fine granulometry and it considerably absorbed the water used in the concrete spreading, influencing the way this material is dealt with. Thus, the value of cement striking decreases with the increase of residues present in trait. The maximal incorporation of the residue was of 50%, massively, for the same factor water/initial cement. The use of residues in concrete results in an 40% increase in the compression resistance. It is also proportional to residue concentration of porcelain in the trait. The microstructure was also favored once porosity and concrete absorption decreases with the use of this residue. The parameters demonstrate the quality and durability of the concrete produced with this residue. The use of porcelain residue in concrete composition has not produced meaningful thermal behavior changes. Thermal conductivity, heat capacity and thermal diffusivity have been maintained basically constant
Resumo:
La investigación abarca la evaluación de métodos para cálculos de elevaciones de temperatura y las respectivas pérdidas de vida útil del aislamiento en transformadores, de acuerdo a estándares internacionales. Las cargas no lineales que circulan por los bobinados de los transformadores de potencia, armónicos, producen efectos térmicos que pueden exceder la capacidad de temperatura que puede soportar el medio aislante, esto acorta la vida útil de los equipos y debe ser conocida