994 resultados para antigen-antibody
Resumo:
Leishmania braziliensis is a causative agent of American Cutaneous Leishmaniasis (ACL). The 034-JCG strain, isolated from a patient from the northern region of Paraná State, Brazil, was cultivated in Blood Agar Base medium, lyophilized and submitted to phenol-water extraction. The extract was treated with RNase I. The carbohydrate containing-antigen (Ag-CHO) was immunogenic to rabbits and showed at least a fraction with some negative charge at pH 8.2. This antigen showed cross-reactivity with the phenol-water extract of the growth medium used for the culture of promastigotes and with the surface antigens of promastigotes. Its composition is: 24.3% of total sugars, from which 11.2% of galactose, 7.5% of mannose and 5.6% of ribose. Protein content was 5.4% and phosphate 18.5%. The antigenic activity was maintained after: repeated freezing-thawing; lyophilization; heating at 100ºC for 30 minutes; treatment with RNase, trichloroacetic acid and sodium metaperiodate. The precipitin line obtained is Periodic Acid Schiff positive. The application of the Ag-CHO in counterimmunoelectrophoresis reaction for the immunodiagnosis of ACL showed 60% sensitivity, and no cross-reaction with the five sera of Chagas' disease patients tested. The use of this antigen in a more sensitive technique, with more samples of sera, may improve these results.
Resumo:
Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.
Resumo:
A simple method of rubella antigen production by treatment with sodium desoxycholate for use in enzyme immunoassay (IMT-ELISA) is presented. When this assay was compared with a commercial test (Enzygnost-Rubella, Behring), in the study of 108 sera and 118 filter paper blood samples, 96.9% (219/226) overall agreement and correlation coefficient of 0.90 between absorbances were observed. Seven samples showed discordant results, negative by the commercial kit and positive by our test. Four of those 7 samples were available, being 3 positive by HI.
Resumo:
Serum samples from 242 HIV-positive persons were studied for the detection of capsular polysaccha-ride antigen of Cryptococcus neoformans; 193 of these patients presented less than 300 CD4+ cells/µl of blood and 49 patients had more than 300 CD4+ cells/µl. None of them had symptoms or signs characteristic of cryptococcosis. The capsular antigen of C. neofarmans was detected by latex agglutination technique with pronase pre-treatment (IMMY, Crypto-Latex Antigen Detection System, Immunomycologics Inc., OK, USA); in 61% of the samples, ELISA technique was also used (Premier, Cryptococcal Antigen, Meridian Diagnostic Inc., Cincinatti, Oh, USA). The comparative study of both methods showed that the results obtained were similar in 96.9% of the cases. The capsular antigen was detected in 13 out of 193 (6.7%) patients with less than 300 CD4+ cells/µl. Cryptococcosis was confirmed mycologically in 3 of these 13 cases (23%) by the isolation of C. neoformans in CSF or blood cultures. Three patients, who had presented negative results of both tests for capsular antigen, suffered disseminated cryptococcosis 4 to 8 months later. The predictive diagnostic value of capsular antigen detection of C. neoformans seems tobe low and we believe that it should not be done routinely in asymptomatic HIV-positive persons.
Resumo:
We studied the susceptibility to Leishmania (Viannia) panamensis in strains of mice. The C57BL/6 strain was resistant and showed self-controlled lesion at the injected foot pad. The BALB/c and DBA/2J strains were susceptible and showed a foot swelling that started day 20 post-infection and progressed to a tumour-like lesion in later period of observation. The CBA/HJ strain was found to be of intermediary resistance. In contrast to other known cutaneous leishmaniasis in mice, the lesion in L. (V.) panamensis-infected mice was restricted to the inoculation site in the skin. In addition, we studied the development of cellular response and antibodies against Leishmania antigen in BALB/c and C57BL/6 strains. The proliferative response of lymph node cells against L. (V.) panamensis antigen was biphasic in both strains. An initial response was seen on day 20, followed by a refractory period between 40 and 80 days and a second response around fourth month post-infection. The response in the latter period was higher in C57BL/6 strain than in BALB/c strain. BALB/c strain presented much higher anti-Leishmania antibody level than C57BL/6 strain. The model and the correlation of immunological variables and the course of the infection are discussed.
Resumo:
Three months after a mass vaccination campaign (coverage: 100%) against measles a random seroepidemiological survey was carried out in students aged 1 to 19 years old in the Municipality of Niterói, State of Rio de Janeiro. Blood samples were tested for measles antibodies by enzyme immunosorbent assay (EIA) and negative cases were tested again using hemagglutination inhibition (HI) and plaque reduction neutralization (PRN). Of the 798 samples tested by EIA, 718 (90.2%) were positive for measles antibodies. PRN test was more sensitive than EIA and HI in detecting measles specific antibodies. The total antibody prevalence increased from 90.2% to 93.2% when HI was employed in EIA negative specimens and to 98.9% when PRN was used. After the mass vaccination campaign a marked decrease in measles incidence was observed in the municipality studied, showing the effectiveness of the strategy used for measles control in developing countries.
Resumo:
In the search for Leishmania recombinant antigens that can be used as a vaccine against American Cutaneous Leishmaniasis, we identified a Leishmania (Leishmania) amazonensis recombinant protein of 33 kD (Larp33) which is recognized by antibodies and peripheral blood leukocytes (PBL) from subjects vaccinated with Leishvacin ®, Larp33 was expressed in Escherichia coli after cloning of a 2,2 kb Sau3A digested genomic fragment of L. (L.) amazonensis into the pDS56-6 His vector. Immunoblotting analysis indicated that Larp33 corresponds to an approximately 40-kD native protein expressed in promastigotes of L.(L.) amazonensis and L. (Viannia) braziliensis. Northern blots of total RNA also demonstrated that the gene coding for this protein is expressed in promastigotes of the major lineages of Leishmania causing American Cutaneous Leishmaniasis. Larp33 induced partial protection in susceptible mouse strains (BALB/c and C57BL/10) against L. (L.) amazonensis after vaccination using Bacille Calmette-Guerin (BCG) as adjuvant. In vitro stimulation of splenocytes from BALB/c protected mice with Larp33 elicited the secretion of IL-2 and IFN-g, suggesting that a Th1 cell-mediated protective response is associated with the resistance observed in these mice. As revealed by its immunogenic and antigenic properties, this novel recombinant antigen is a suitable candidate to compose a vaccine against cutaneous leishmaniasis
Resumo:
Crude Toxoplasma gondii antigens represent raw material used to prepare reagents to be employed in different serologic tests for the diagnosis of toxoplasmosis, including the IgM and IgG indirect hemagglutination (IgG-HA and IgM-HA) tests. So far, the actual antigenic molecules of the parasite involved in the interaction with agglutinating anti-T. gondii antibodies in these tests are unknown. The absorption process of serum samples from toxoplasmosis patients with the IgG-HA reagent (G-toxo-HA) demonstrated that red cells from this reagent were coated with T. gondii antigens with Mr of 39, 35, 30, 27, 22 and 14 kDa. The immune-absorption process with the IgM-HA reagent (M-toxo-HA), in turn, provided antibody eluates which recognized antigenic bands of the parasite corresponding to Mr of 54, 35 and 30 kDa, implying that these antigens are coating red cells from this reagent. The identification of most relevant antigens for each type of HA reagent seems to be useful for the inspection of the raw antigenic material, as well as of reagent batches routinely produced. Moreover the present findings can be used to modify these reagents in order to improve the performance of HA tests for the diagnosis of toxoplasmosis
Resumo:
This work was planned by taking into account all the knowledge accumulated from the immunological study of paracoccidioidomycosis. It aimed at comparing a polysaccharide antigen from Histoplasma capsulatum to a classic histoplasmin with the help of intradermal tests of delayed type of hypersensitivity. Tests were applied to 115 individuals in Santo Amaro, a town in the state of São Paulo. Positive results using classic histoplasmin were obtained in 46.0% cases whereas positive results using the polysaccharide antigen at its hightest concentration were obtained in 51.30% cases. The major conclusion in this investigation is that it is possible to use the polysaccharide antigen as histoplasmin instead of the filtrate antigen
Resumo:
Twenty-seven mycologically proven cases of paracoccidioidomycosis (PCM) were treated with itraconazole (100-200 mg/day in month 1 and 100 mg/day until month 6-8) and evaluated clinically and serologically, up to 3.5 years post-therapy, using Dot-blot and ELISA for measuring the titers of IgG, IgA and IgM anti-P. brasiliensis antibodies and Western-blot for determining IgG, IgA and IgM antibodies against the antigen components of the fungus. Before treatment, 81.5% (Dot-blot) and 84% (ELISA) of the patients presented elevated IgG anti-P. brasiliensis antibody titers which dropped slightly with treatment. On the other hand, the percentages of pre-treatment high-titered sera for IgA and IgM anti-P.brasiliensis were lower (5l.9% and 5l.8%: Dot-blot; 16.5 and 36%: ELISA, respectively) but the titers tended to become negative more frequently with treatment. Prior to treatment, the percentages of positivity for IgG, IgA and IgM anti-P.brasiliensis antibodies in Western-blot were 96%, 20.8% and 41.6%, respectively. Antigens with molecular weights varying from 16-78 kDa, from 21-76 kDa and from 27-78 kDa were reactive for IgG, IgA and IgM antibodies, respectively. The most frequently reactive antigenic components had molecular weights of 27, 33 and 43 kDa for IgG, and 70 for IgA and IgM antibodies. During the period of study, the patients responded well to treatment. The present data confirm the diversity and complexity of the humoral response in PCM, and the importance of utilizing different serological tests to detect IgG, IgA and IgM anti-P. brasiliensis antibodies
Resumo:
Antibodies to a number of parasite antigens are found in schistosomiasis patients, and antibodies to early developmental stages were demonstrated to be efficient immunologic markers for the diagnosis of schistosomiasis. In the present study, decay patterns of IgM and IgG antibodies against cercariae and schistosomula were investigated, in comparison to antibodies against worms and eggs in schistosomiasis patients after chemotherapy, for an investigation of seroepidemiologic aspects. Data obtained in the study of 359 serum samples from patients with Schistosoma mansoni infection, noninfected individuals, and patients followed-up for a period of 12 to 15 months after treatment provided the basis to postulate a general pattern for the kinetics of antibody decay. Before treatment, the antibody pattern was represented by a unimodal curve, which shifted to a bimodal curve after treatment, and ended with a unimodal curve similar to that for the noninfected group. Different types of antibodies were classified into four categories according to their decay features, and anti-schistosomulum IgM was classified into the moderate-decay caterogy, whereas other antibodies to early parasite stages were classified into the slow-decay category. The present methodology permits the identification of the most suitable antibodies to be detected in field control programs for schistosomiasis or other parasitoses
Resumo:
Cryo-microtome sections of larvae of Strongyloides stercoralis and S. ratti respectively obtained from human and rat feces cultures, were used as antigens. Fluoresceinate conjugates against human IgG were employed at the ideal titer of 10 for S. stercoralis and 100 for S. ratti. The sensitivity of the indirect immunofluorescence reaction (IIF) was 94.4% and 92.5% and the specificity 94.2% and 97.1% for the two specific larval antigens, respectively. Sera from 123 persons (54 from carriers of S. stercoralis infections and 69 from controls) were submitted to the reaction. The titers of different sera varied from 20 to 2560. There was a significant linear correlation (r = 0.85 p £ 0.001) between the antibodies from the two species of larval antigens. We conclude that both antigens may be used in the IIF reaction for the diagnosis of human strongyloidiasis. Due to the feasibility of safe and low-cost mass production of S. ratti larvae in the laboratory with a considerable economy of conjugate, their utilization in the serum diagnosis of human strongyloidiasis is recommended
Resumo:
The persistence, in some subjects, of specific IgM antibodies to Toxoplasma gondii for several months after the acute phase of infection has complicated the interpretation of serological test results for toxoplasmosis. Several reports have emphasized the value of the detection of Toxoplasma-specific IgA antibodies for the diagnosis of acute toxoplasmosis. In this article, we report the follow-up profiles of Toxoplasma-specific IgM and IgA antibodies in serum samples obtained from 12 patients at various intervals after the onset of the clinical manifestations of infection. IgM antibodies were detected by the indirect immunofluorescence (IIF) test, antibody capture enzyme-linked immunosorbent assay (cELISA) and enzyme-mediated chemilluminescent technique (CmL). IgA antibodies were quantified by the direct ELISA (dELISA) and cELISA procedures. As defined by the manufacturer of the cELISA test for IgA used, most patients with acute toxoplasmosis have antibody levels > 40 arbritary units per ml (AU/ml). At values > 40 AU/ml, the cELISA for IgA detected significant antibody levels for a shorter time than the other techniques used for IgM and IgA detection. However, IgA levels £ 40 AU/ml do not exclude the possibility of acute toxoplasmosis since such levels can be reached very soon after infection with T. gondii. The results obtained in the present study show that the serological diagnosis of acute toxoplasmosis may not be such an easy task. Our data suggest that use of the IgA-cELISA concomitantly with IgM antibody screening could permit, in some circumstances, a more efficient diagnosis of acute acquired toxoplasmosis
Resumo:
O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.