907 resultados para Variable Velocity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a control method for a class of continuous-time switched systems, using state feedback variable structure controllers. The method is applied to the control of a two-cell dc-dc buck converter and a control circuit design using the software PSpice is proposed. The design is based on Lyapunov-Metzler-SPR systems and the performance of the resulting control system is superior to that afforded by a recently-proposed alternative sliding-mode control technique. The dc-dc power converters are very used in industrial applications, for instance, in power systems of hybrid electric vehicles and aircrafts. Good results were obtained and the proposed design is also inexpensive because it uses electric components that can be easily found for the hardware implementation. Future researches on the subject include the hardware validation of the dc-dc converter controller and the robust control design of switched systems, with structural failures. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work is to predict the minimum fluidization velocity Umf in a gas-solid fluidized bed. The study was carried out with an experimental apparatus for sand particles with diameters between 310μm and 590μm, and density of 2,590kg/m3. The experimental results were compared with numerical simulations developed in MFIX (Multiphase Flow with Interphase eXchange) open source code [1], for three different sizes of particles: 310mum, 450μm and 590μm. A homogeneous mixture with the three kinds of particles was also studied. The influence of the particle diameter was presented and discussed. The Ergun equation was also used to describe the minimum fluidization velocity. The experimental data presented a good agreement with Ergun equation and numerical simulations. Copyright © 2011 by ASME.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a control method for a class of continuous-time switched systems, using state feedback variable structure controllers. The method is applied to the control of a non-trivial dc-dc power converter and a simple and inexpensive control circuit design, that was simulated using the software PSpice, is proposed. The design is based on Lyapunov-Metzler-SPR systems and the performance of the resulting control system is superior to that afforded by a recently proposed alternative sliding-mode control technique. © 2011 IFAC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a bridgeless boost interleaved PFC (power factor correction) converter with variable duty cycle control. The application of bridgeless technique causes reduction of conduction losses, while the interleaving technique of converters cells allows division of efforts in semiconductor devices and reduction of weight and volume of the input EMI filter. The use of variable duty cycle control has the functions of regulating the output voltage and eliminating the low order harmonic components that appears in the input current of the common interleaved power factor converters working in Discontinuous Conduction Mode (DCM). The simulation results of the proposed converter presented high power factor and a good transient response in relation to the output voltage regulation in presence of high load variations and supply voltage variations. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Documento disponible en inglés (565.03)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A search for supersymmetry in final states with jets and missing transverse energy is performed in pp collisions at a centre-of-mass energy of s=7 TeV. The data sample corresponds to an integrated luminosity of 4.98 fb-1 collected by the CMS experiment at the LHC. In this search, a dimensionless kinematic variable, α T, is used as the main discriminator between events with genuine and misreconstructed missing transverse energy. The search is performed in a signal region that is binned in the scalar sum of the transverse energy of jets and the number of jets identified as originating from a bottom quark. No excess of events over the standard model expectation is found. Exclusion limits are set in the parameter space of the constrained minimal supersymmetric extension of the standard model, and also in simplified models, with a special emphasis on compressed spectra and third-generation scenarios.[Figure not available: see fulltext.] © 2013 CERN for the benefit of the CMS Collaboration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In most studies on beef cattle longevity, only the cows reaching a given number of calvings by a specific age are considered in the analyses. With the aim of evaluating all cows with productive life in herds, taking into consideration the different forms of management on each farm, it was proposed to measure cow longevity from age at last calving (ALC), that is, the most recent calving registered in the files. The objective was to characterize this trait in order to study the longevity of Nellore cattle, using the Kaplan-Meier estimators and the Cox model. The covariables and class effects considered in the models were age at first calving (AFC), year and season of birth of the cow and farm. The variable studied (ALC) was classified as presenting complete information (uncensored = 1) or incomplete information (censored = 0), using the criterion of the difference between the date of each cow's last calving and the date of the latest calving at each farm. If this difference was >36 months, the cow was considered to have failed. If not, this cow was censored, thus indicating that future calving remained possible for this cow. The records of 11 791 animals from 22 farms within the Nellore Breed Genetic Improvement Program ('Nellore Brazil') were used. In the estimation process using the Kaplan-Meier model, the variable of AFC was classified into three age groups. In individual analyses, the log-rank test and the Wilcoxon test in the Kaplan-Meier model showed that all covariables and class effects had significant effects (P < 0.05) on ALC. In the analysis considering all covariables and class effects, using the Wald test in the Cox model, only the season of birth of the cow was not significant for ALC (P > 0.05). This analysis indicated that each month added to AFC diminished the risk of the cow's failure in the herd by 2%. Nonetheless, this does not imply that animals with younger AFC had less profitability. Cows with greater numbers of calvings were more precocious than those with fewer calvings. Copyright © The Animal Consortium 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poor posture control has been associated with an increased risk of falls and mobility disability among older adults. This study was conducted to assess the test-retest reliability and sensitivity to group differences regarding the time-limit (TLimit) of one-leg standing and selected balance parameters obtained with a force platform in older and young adults. A secondary purpose was to assess the relationship between TLimit and these balance parameters. Twenty-eight healthy older adults (age: 69±5years) and thirty young adults (age: 21±4years) participated in this study. Two one-leg stance tasks were performed: (1) three trials of 30s maximum and (2) one TLimit trial. The following balance parameters were computed: center of pressure area, RMS sway amplitude, and mean velocity and mean frequency in both the anterio-posterior and medio-lateral directions. All balance parameters obtained with the force platform as well as the TLimit variable were sensitive to differences in balance performance between older and young adults. The test-retest reliability of these measures was found to be acceptable (ICC: 0.40-0.85), with better ICC scores observed for mean velocity and mean frequency in the older group. Pearson correlations coefficients (r) between balance parameters and TLimit ranged from -0.16 to -0.54. These results add to the current literature that can be used in the development of measurement tools for evaluating balance in older and young adults. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to verify whether there is an association between anaerobic running capacity (ARC) values, estimated from two-parameter models, and maximal accumulated oxygen deficit (MAOD) in army runners. Methods: Eleven, trained, middle distance runners who are members of the armed forces were recruited for the study (20 ± 1 years). They performed a critical velocity test (CV) for ARC estimation using three mathematical models and an MAOD test, both tests were applied on a motorized treadmill. Results: The MAOD was 61.6 ± 5.2 mL/kg (4.1 ± 0.3 L). The ARC values were 240.4 ± 18.6 m from the linear velocity-inverse time model, 254.0 ± 13.0 m from the linear distance-time model, and 275.2 ± 9.1 m from the hyperbolic time-velocity relationship (nonlinear 2-parameter model), whereas critical velocity values were 3.91 ± 0.07 m/s, 3.86 ± 0.08 m/s and 3.80 ± 0.09 m/s, respectively. There were differences (P < 0.05) for both the ARC and the CV values when compared between velocity-inverse time linear and nonlinear 2-parameter mathematical models. The different values of ARC did not significantly correlate with MAOD. Conclusion: In conclusion, estimated ARC did not correlate with MAOD, and should not be considered as an anaerobic measure of capacity for treadmill running. © 2013 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effect of fast-velocity concentric isokinetic resistance training (FV) on the rate of force development (RFD) at early (<100 ms) and late phases (>100 ms) of rising muscle force. Nine men participated in a 6-week resistance training intervention for the lower body, and nine matched subjects participated as controls (CON). During concentric isokinetic (180°s-1) knee extension training, subjects were instructed to do each contraction 'as fast and forcefully as possible'. Maximal muscle strength (MVC) and RFD (0-10, 0-20, ..., 0-250 ms from the onset of contraction) were measured during maximal voluntary isometric contraction of the knee extensors (KE). There were no significant changes in MVC of KE in both groups after intervention (FV = 314·2 ± 101·1 versus 338·7 ± 88·0 N{bullet operator}m, P>0·05; CON = 293·3 ± 94·8 versus 280·0 ± 72·2 N{bullet operator}m, P>0·05). The RFD increased 39-71% at time intervals up to 90 ms from the onset of the contraction (P<0·05), whereas no change occurred at later time intervals. Similarly, relative RFD (i.e.%MVC{bullet operator}s-1) (RFDr) increased 33-56% at time intervals up to 70 ms from the onset of the contraction (P<0·05). It can be concluded that a short period of resistance training performed with concentric fast-velocity isokinetic muscle contractions is able to enhance RFD and RFDr obtained at the early phase of rising muscle force. © 2013 The Authors Clinical Physiology and Functional Imaging © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exercise capacity and quality of life (QOL) are important outcome predictors in patients with systolic heart failure (HF), independent of left ventricular (LV) ejection fraction (LVEF). LV diastolic function has been shown to be a better predictor of aerobic exercise capacity in patients with systolic dysfunction and a New York Heart Association (NYHA) classification >II. We hypothesized that the currently used index of diastolic function E/e' is associated with exercise capacity and QOL, even in optimally treated HF patients with reduced LVEF. This prospective study included 44 consecutive patients aged 55±11 years (27 men and 17 women), with LVEF,0.50 and NYHA functional class I-III, receiving optimal pharmacological treatment and in a stable clinical condition, as shown by the absence of dyspnea exacerbation for at least 3 months. All patients had conventional transthoracic echocardiography and answered the Minnesota Living with HF Questionnaire, followed by the 6-min walk test (6MWT). In a multivariable model with 6MWT as the dependent variable, age and E/e' explained 27% of the walked distance in 6MWT (P=0.002; multivariate regression analysis). No association was found between walk distance and LVEF or mitral annulus systolic velocity. Only normalized left atrium volume, a sensitive index of diastolic function, was associated with decreased QOL. Despite the small number of patients included, this study offers evidence that diastolic function is associated with physical capacity and QOL and should be considered along with ejection fraction in patients with compensated systolic HF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we improve the regularity in time of the gradient of the pressure field in the solution of relaxed version of variational formulation proposed by V. I. Arnold and by Y. Brenier, for the incompressible Euler equations with variable density. We obtain that the pressure field is not only a measure, but a function in Lloc2((0,T);BVloc(D)) as an extension of the work of Ambrosio and Figalli (2008) in [1] to the variable density case. © 2013 Elsevier Ltd.