987 resultados para Valvular prosthesis
Resumo:
An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
This study compared splinted and non-splinted implant-supported prosthesis with and without a distal proximal contact using a digital image correlation method. An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants replacing the second premolar and first molar. Splinted and non-splinted metal-ceramic screw-retained crowns were fabricated and loaded with and without the presence of the second molar. A single-camera measuring system was used to record the in-plane deformation on the model surface at a frequency of 1.0 Hz under a load from 0 to 250 N. The images were then analyzed with specialist software to determine the direct (horizontal) and shear strains along the model. Not splinting the crowns resulted in higher stress transfer to the supporting implants when the second molar replica was absent. The presence of a second molar and an effective interproximal contact contributed to lower stress transfer to the supporting structures even for non-splinted restorations. Shear strains were higher in the region between the molars when the second molar was absent, regardless of splinting. The opposite was found for the region between the implants, which had higher shear strain values when the second molar was present. When an effective distal contact is absent, non-splinted implant-supported restorations introduce higher direct strains to the supporting structures under loading. Shear strains appear to be dependent also on the region within the model, with different regions showing different trends in strain changes in the absence of an effective distal contact. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Background: The role of osteocytes in bone structure and function remains partially unresolved. Their participation in mechanotransduction, i.e., the conversion of a physical stimulus into a cellular response, has been hypothesized. The present study was an evaluation of the osteocyte density in the peri-implant bone of immediately loaded and submerged dental implants. Methods: Fourteen male patients were included in the study; all of them were partially edentulous and needed a posterior mandibular restoration. Implants were inserted in these areas; half of the sample was loaded immediately (included in a fixed provisional prosthesis on the same day as implant surgery), whereas the other half was left to heal submerged. Fourteen implants (seven immediately loaded and seven unloaded) were retrieved with a trephine after a healing period of 8 weeks. The specimens were treated to obtain thin ground sections, and histomorphometry was used to evaluate the osteocyte index in the peri-implant bone. Results: A higher and statistically significant number of osteocytes was found in the peri-implant bone around immediately loaded implants (P=0.0081). A correlation between the percentage of bone-implant contact and osteocyte density was found for immediately loaded implants (P=0.0480) but not for submerged implants (P=0.2667). Conclusion: The higher number of osteocytes in the peri-implant bone around immediately loaded implants could be related to the functional adaptation required by the loading stimulus, which also explains the hypothesized involvement of the osteocytes in the maintenance of the bone matrix. J Periodontol 2009;80:499-504.
Resumo:
This paper reports a case in which a previous traumatic injury at the age of 2 and pulp necrosis to a primary incisor resulted in a rare injury to the permanent successor tooth. The radiographic examination at the age of 9 showed the arrest of root formation of the permanent maxillary right central incisor, which did not erupt. Tooth 11 was extracted and a functional removable space maintainer was prepared. At the age of 17, the patient received an anterior fixed prosthesis for re-establishment of the esthetics, phonetics and deglutition.
Resumo:
Purpose: The aim of the present study was to investigate the healing, integration, and maintenance of autogenous onlay bone grafts and implant osseointegration either loaded in the early or the delayed stages. Materials and Methods: A total of 5 male clogs received bilateral blocks of onlay bone grafts harvested from the contralateral alveolar ridge of the mandible. On one side, the bone block was secured by 3 dental implants (3.5 mm x 13.0 mm, Osseospeed; Astra Tech AB, Molndal, Sweden). Two implants at the extremities of the graft were loaded 2 clays after installation by abutment connection and prosthesis (simultaneous implant placement group); the implant in the middle remained unloaded and served as the control. On the other side, the block was fixed with 2 fixation screws inserted in the extremities of the graft. Four weeks later, the fixation screws were replaced with 3 dental implants. The loading procedure (delayed implant placement group) was performed 2 clays later, as described for the simultaneous implant placement sites. The animals were sacrificed 12 weeks after the grafting procedure. Implant stability was measured through resonance frequency analysis. The bone volume and density were assessed on computed tomography. The bone to implant contact and bone area in a region of interest were evaluated on histologic slides. Results: The implant stability quotient showed statistical significance in favor of the delayed loaded grafts (P=.001). The bone-to-implant contact (P=.008) and bone area in a region of interest (P=0.005) were significantly greater in the delayed group. Nevertheless, no difference was found in terms of graft volume and density between the early loaded and delayed-loaded approaches. Conclusions: The protocol in which the implant and bone graft were given delayed loading allows for effective quality of implant osseointegration and stabilization, with healing and remodeling occurring in areas near the implant resulting in denser bone architecture. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Sing 68:825-832, 2010
Resumo:
Objectives: The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-J circle divide rgensen Index) by means of a computerised comparison method. Background: Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Materials and methods: Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-J circle divide rgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. Results: The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Conclusion: Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-J circle divide rgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.
Resumo:
Objective: Self-rating provides a simple direct way of capturing perceptions of health. The objective of this study was to estimate the prevalence and associated factors of poor self-rated oral health among elders. Methods: National data from a cross-sectional population-based study with a multistage random sample of 4786 Brazilian older adults (aged 65-74) in 250 towns were analysed. Data collection included oral examinations (WHO 1997) and struct-ured interviews at elderly households. The outcome was measured by a single five-point-response-scale question dichotomized into `poor` (fair/poor/very poor) and `good` (good/very good) self-rated oral health. Data analyses used Poisson regression models stratified by sex. Results: The prevalence of poor self-rated oral health was 46.6% (95% CI: 45.2-48%) in the whole sample, 50.3% (48-52.5) in men and 44.2% (42.4-46) in women. Higher prevalence ratios (PR) were found in elders reporting unfavourable dental appearance (PR = 2.31; 95% CI: 2.02-2.65), poor chewing ability (PR = 1.64; CI: 1.48-1.8) and dental pain (PR = 1.44; CI: 1.04-1.23) in adjusted analysis. Poor self-perception was also associated with being men, black, unfavourable socioeconomic circumstances, unfavourable clinical oral health and with not using or needing a dental prosthesis. Conclusion: Assessment and understanding of self-rated oral health should take into account social factors, subjective and clinical oral symptoms.
Resumo:
Systemic inflammation after augmentation mammaplasty with modern silicone implants is not currently recognized. In a prospective controlled study, C-reactive protein and other variables were monitored, aiming to test this hypothesis in a young cohort of patients. Females (18-30 years old, BMI = 18.5-30 kg/m(2), N = 52) were consecutively recruited for breast implant (n = 24, Group I) and for abdominal liposuction (n = 28, Group II/Controls). Patients were interviewed at baseline and followed until 6 months after operation. Variables included demographic and clinical information, surgical outcome, inflammatory markers and autoantibodies. Operations were well tolerated, without surgical or infectious complications. Mean prosthesis size was 258 +/- A 21 ml (range = 220-280) and mean aspirate of liposuction was 1972 +/- A 499 ml (range = 1200-3000). Preoperative, 2-month, and 6-month C-reactive protein concentrations for breast implant patients were 1.3 +/- A 1.2, 4.8 +/- A 3.0, and 4.3 +/- A 6.4 mg/l and for liposuction 3.5 +/- A 2.7, 3.5 +/- A 2.1, and 2.2 +/- A 2.2 mg/l, respectively. Change at 2 months was significant (p = 0.001). Autoantibody investigation failed to reveal remarkable aberrations, except for anticardiolipin elevation, which was nearly symmetrical in the two groups. C-reactive protein levels increased after operation and correlated with proinflammatory and procoagulatory indices. A mild increase in anticardiolipin IgM occurred but differences between populations were lacking. Despite excellent cosmetic outcomes and lack of complications, acute phase reaction could signal ongoing immunogenicity of silicone and long-term monitoring is recommended.
Resumo:
Objective: To evaluate the effect of the neuregulins 1-alpha and 1-beta on the regeneration the sciatic nerves of male adult C57BL/6J mice, using the tubulization technique. Methods: Eighteen animals were used, divided into three groups. A polyethylene prosthesis was implanted in a 4.0 mm defect of the left sciatic nerve, as follows: group 1 containing only purified collagen (Vitrogen (R)); group 2, collagen with neuregulin 1-alpha; group 3, collagen with neuregulin 1-beta. The control group consisted of six segments of right sciatic nerves. After four weeks, the animals were sacrificed. A segment from the midpoint of the nerve regenerated inside the prostheses was extracted; histological sections were standardized, and slides were made up for histomorphometric analysis. Results: the results were statistically compared using the Tukey multiple comparisons test and The Student`s t test. The animals treated with neuregulins had greater numbers of myelinized axons, with a statistically significant difference in relation to the collagen-only group. There was no statistical difference between the neuregulin 1-alpha and 1-beta groups. Conclusion: The addition of neuregulins provided a significant increase in the number of myelinized fibers.
Resumo:
Baseada na perspectiva teórica do campo dos Estudos Culturais e sócio-históricos sobre o corpo, esta dissertação analisou os significados culturais que os indivíduos atribuíam aos seus corpos e suas vidas cotidianas após terem sido submetidos a amputação e se tornarem usuários de prótese. O material empírico foi coletado através da observação participante, do diário de campo e da entrevista semi-estruturada, realizada numa clínica ortopédica privada, situada em Porto Alegre, especializada na reabilitação e protetização de indivíduos que foram submetidos a amputação. O grupo participante do estudo foi: o fisioterapeuta e o protesista, e por nove pacientes da clínica, homens e mulheres, todos amputados de um membro inferior, com idades variando entre 18 e 82 anos, sendo que apresentavam em comum o fato de terem se tornado amputados após um acidente ou em decorrência da diabete. A pesquisa de campo foi desenvolvida no período de Fevereiro de 2003 a Setembro de 2003, através da participação de sessões de fisioterapia, das reuniões mensais dos grupos de apoio aos amputados, onde foi acompanhado o processo de adaptação à prótese. O estudo consistiu em problematizar os efeitos provocados na vida cotidiana destes indivíduos pelas transformações ocorridas em seus corpos secundários à amputação, bem como aqueles produzidos pelo "acoplamento" com a prótese, buscando tornar visível o processo vivenciado por eles, ou seja, o estranhamento e a naturalização do seu "novo" corpo fabricado pelas tecnologias. A dissertação representa, portanto, as reflexões construídas a partir da investigação desenvolvida especificamente neste grupo, onde o corpo amputado e protetizado foi vislumbrado como algo produzido e ressignificado na cultura, sendo assim moldável, provisório e reinventado continuamente.
Resumo:
Human multipotent mesenchymal stromal cells (MSCs), also known as mesenchymal stem cells, have become an important and attractive therapeutic tool since they are easily isolated and cultured, have in vitro expansion potential, substantial plasticity and secrete bioactive molecules that exert trophic effects. The human umbilical cord as a cell source for cell therapy will help to avoid several ethical, political, religious and technical issues. One of the main issues with SC lines from different sources, mainly those of embryonic origin, is the possibility of chromosomal alterations and genomic instability during in vitro expansion. Cells isolated from one umbilical cord exhibited a rare balanced paracentric inversion, likely a cytogenetic constitutional alteration, karyotype: 46,XY,inv(3)(p13p25~26). Important genes related to cancer predisposition and others involved in DNA repair are located in 3p25~26. Titanium is an excellent biomaterial for bone-implant integration; however, the use can result in the generation of particulate debris that can accumulate in the tissues adjacent to the prosthesis, in the local bone marrow, in the lymph nodes, liver and spleen. Subsequently may elicit important biological responses that aren´t well studied. In this work, we have studied the genetic stability of MSC isolated from the umbilical cord vein during in vitro expansion, after the cryopreservation, and under different concentrations and time of exposition to titanium microparticles. Cells were isolated, in vitro expanded, demonstrated capacity for osteogenic, adipogenic and chondrogenic differentiation and were evaluated using flow cytometry, so they met the minimum requirements for characterization as MSCs. The cells were expanded under different concentrations and time of exposition to titanium microparticles. The genetic stability of MSCs was assessed by cytogenetic analysis, fluorescence in situ hybridization (FISH) and analysis of micronucleus and other nuclear alterations (CBMN). The cells were able to internalize the titanium microparticles, but MSCs preserve their morphology, differentiation capacity and surface marker expression profiles. Furthermore, there was an increase in the genomic instability after long time of in vitro expansion, and this instability was greater when cells were exposed to high doses of titanium microparticles that induced oxidative stress. It is necessary always assess the risks/ benefits of using titanium in tissue therapy involving MSCs, considering the biosafety of the use of bone regeneration using titanium and MSCs. Even without using titanium, it is important that the therapeutic use of such cells is based on analyzes that ensure quality, security and cellular stability, with the standardization of quality control programs appropriate. In conclusion, it is suggested that cytogenetic analysis, FISH analysis and the micronucleus and other nuclear alterations are carried out in CTMH before implanting in a patient
Resumo:
A frequently encountered difficulty in oral prosthetics is associated with the loss of metallic alloys during the melting stage of the production of metal-ceramic replacement systems. Remelting such materials could impar their use in oral rehabilitation due to loss in esthetics, as well as in the chemical, physical, electrochemical and mechanical properties. Nowadays, the Ni-Cr-Mo-Ti alloy is widely used in metal-ceramic systems. Manufacturers state that this material can be remelted without significant alterations in its behavior, however little has been established as to the changes in the performance of this alloy after successive remelting, which is common practice in oral prosthetics. Therefore, the objective of this study was to evaluate possible changes in the esthetics and associated properties of metalceramic samples consisting of Ni-Cr-Mo-Ti and dental porcelain. Three to five remelting steps were carried out. The results revealed that Ni-Cr-Mo-Ti can be safely used even after three remelting steps. Further remelting significantly affect the characteristics of the alloys and should not be recommended for the manufacture of metal-ceramic systems
Resumo:
The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit, as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles
Resumo:
At present, the material of choice for performing aesthetic dental prosthetic work is in the ceramic. Among them, the ceramic base of stabilized zirconia with 3% yttria (3Y - TZP) stand out for having excellent physical and mechanical properties. During the machining of blocks of zirconia in the laboratory to prepare the various types of prostheses, much of the material is given off in the form of powder, which is subsequently discarded. The waste of this material results in financial loss, reflecting higher final cost treatment for patients, as well as damage to the environment, thanks to the processes involved in the manufacture and disposal of the ceramic. This research, pioneered the recycling of zirconium oxide powder obtained during milling of dental crowns and bridges, we highlight the social and environmental aspects and aims to establish a protocol for the reuse of waste (powder of zirconia Zirkonzahn® system) discarded to obtain a new block of compacted zirconia to maintain the same mechanical and microstructural properties of commercial high-cost imported material. To compare with the commercial material, samples were uniaxially (20 MPa) and isostatically (100 MPa), and its mechanical and microstructural characterization was performed through tests of density, porosity, dilatometry, X-ray diffraction (XRD), hardness, fracture toughness, resistance to fracture electron microscopy (SEM) and analysis of grain size. The results observed in the samples were isostatically pressed similiares those obtained with samples from the commercial material demonstrating the viability of the process
Resumo:
The present study seeks to understand tooth loss by investigating the social representations in the daily life of elderly individuals, thus characterizing itself as a comparative and analytic research. It is known that tooth loss is a common occurrence in elderly individuals, interfering at the psychosocial and biological levels, through its functional, esthetical and social implications. The area of oral health in Brazil is lacking studies on this topic, especially with respect to the psychosocial aspects of the elderly. The Theory of Social Representations and the Central Nucleus Theory were selected for theoretical-methodological support. The Free Association of Words Test was used, whose inducing stimulus were the words tooth loss , in which each subject was asked to associate 3 words, to respond to a questionnaire related to socio-economic conditions and containing an investigation of tooth loss, access to odontological services and the need for dental treatment, and to undergo a focus group interview. The study sample consisted of 120 individuals 60 years of age or over, resident in Natal, RN, Brazil and participants of the Live Together to Live Better group of the Basic Health Unit of Felipe Camarão Residential District and Unati (Open University of the Elderly); an interview was performed with 36 subjects. Data analysis was performed by Evoc 2000, SPSS/99, Graph Pad and Alceste softwares. The results demonstrate that the central nucleus of the social representations of tooth loss for the Live Together group emerged from the difficulty in eating categories, showing a relation between physiologic necessity, desire and pleasure from eating, not to mention the pain that resulted from justifying the tooth loss. Besides the central discourses, the following peripheral elements were gathered: difficulty in adapting to the prosthesis, treatment and difficulty in speaking. All of these categories, except the last, also comprised the class themes of the group interview. For the Unati group the central nucleus emerged from the socio-economic difficulties categories, demonstrating a narrow relation between poverty, access to health and education and esthetics, confirming in the discourse of common sense, the association between tooth loss and aging. At the margin of the central discourses was collected the peripheral element difficulty in adapting to the prosthesis, found both in the Live Together and Unati groups, which expresses the resistance of the subject to this new situation and the failure of the rehabilitation treatment in the sense of reviving the memory of their natural teeth. All of these categories also constitute the class themes of the of the group interview. Thus, through the study of the social representations, we can reveal a reality in the perspective of the social subjects, contemplating the multiple facets of the social-cultural reality experienced by these individuals