1000 resultados para Ultra-sonografia doppler dupla


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the impact of consuming ultra-processed foods on the micronutrient content of the Brazilian population’s diet.METHODS This cross-sectional study was performed using data on individual food consumption from a module of the 2008-2009 Brazilian Household Budget Survey. A representative sample of the Brazilian population aged 10 years or over was assessed (n = 32,898). Food consumption data were collected through two 24-hour food records. Linear regression models were used to assess the association between the nutrient content of the diet and the quintiles of ultra-processed food consumption – crude and adjusted for family incomeper capita.RESULTS Mean daily energy intake per capita was 1,866 kcal, with 69.5% coming from natural or minimally processed foods, 9.0% from processed foods and 21.5% from ultra-processed foods. For sixteen out of the seventeen evaluated micronutrients, their content was lower in the fraction of the diet composed of ultra-processed foods compared with the fraction of the diet composed of natural or minimally processed foods. The content of 10 micronutrients in ultra-processed foods did not reach half the content level observed in the natural or minimally processed foods. The higher consumption of ultra-processed foods was inversely and significantly associated with the content of vitamins B12, vitamin D, vitamin E, niacin, pyridoxine, copper, iron, phosphorus, magnesium, selenium and zinc. The reverse situation was only observed for calcium, thiamin and riboflavin.CONCLUSIONS The findings of this study highlight that reducing the consumption of ultra-processed foods is a natural way to promote healthy eating in Brazil and, therefore, is in line with the recommendations made by the Guia Alimentar para a População Brasileira (Dietary Guidelines for the Brazilian Population) to avoid these foods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the modeling efforts on antenna design and frequency selection to monitor brain temperature during prolonged surgery using noninvasive microwave radiometry. A tapered log-spiral antenna design is chosen for its wideband characteristics that allow higher power collection from deep brain. Parametric analysis with the software HFSS is used to optimize antenna performance for deep brain temperature sensing. Radiometric antenna efficiency (eta) is evaluated in terms of the ratio of power collected from brain to total power received by the antenna. Anatomical information extracted from several adult computed tomography scans is used to establish design parameters for constructing an accurate layered 3-D tissue phantom. This head phantom includes separate brain and scalp regions, with tissue equivalent liquids circulating at independent temperatures on either side of an intact skull. The optimized frequency band is 1.1-1.6 GHz producing an average antenna efficiency of 50.3% from a two turn log-spiral antenna. The entire sensor package is contained in a lightweight and low-profile 2.8 cm diameter by 1.5 cm high assembly that can be held in place over the skin with an electromagnetic interference shielding adhesive patch. The calculated radiometric equivalent brain temperature tracks within 0.4 degrees C of the measured brain phantom temperature when the brain phantom is lowered 10. C and then returned to the original temperature (37 degrees C) over a 4.6-h experiment. The numerical and experimental results demonstrate that the optimized 2.5-cm log-spiral antenna is well suited for the noninvasive radiometric sensing of deep brain temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente,Perfil Engenharia Sanitária

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Engenharia Física, especialidade de Engenharia de Superfícies, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Atherosclerotic carotid disease represents approximately 20% of the causes of ischemic stroke. Effective treatment options, such as endovascular or surgical revascularization procedures, are available. Doppler Ultrasound (DUS) is a non-invasive, inexpensive, routine exam used to evaluate the presence of internal carotid artery (ICA) stenosis. We retrospectively analysed the prevalence of severe atherosclerotic carotid disease in a population of patients with acute ischemic stroke/transitory ischemic attacks (TIAs), and the role of DUS in the detection of ICA stenosis and treatment decisions in these patients. METHODS: A total of 318 patients with ischemic stroke or TIAs was admitted to our stroke unit, and 260 patients were studied by DUS. ICA stenosis was evaluated by DUS according to peak systolic velocity. All DUS exams were performed by the same operator. ICA stenosis was further assessed in 43 patients by digital subtraction angiography (DSA) using NASCET criteria. RESULTS: Of the total 318 patients, 260 (82%) had DUS evaluation. Of the total 520 ICAs studied by DUS, degrees of ICA stenosis were: 0-29% n= 438 (84%); 30-49% n= 8 (2%); 50-69% n= 27 (5%); 70-89% n= 15 (3%); 90-99% n= 20 (4%); oclusão n= 14 (2%). Of the total 260 patients studied, 43 (16.5%) underwent DSA. Sensibility and specificity of DUS in the diagnosis of carotid stenosis over 70% were, respectively, 91% e 84%. Of the total 31 patients with significant carotid stenosis (70-99%), 23 (74%) underwent subsequent carotid revascularization procedures. DISCUSSION: DUS is an important screening test in our stroke unit, justifying its use as a routine exam for all patients with ischemic stroke/TIAs. Moreover, our results show the relevance of severe carotid disease in a population with acute ischemic stroke/TIAs (16.5%), with a total of 9% of patients being submitted to carotid revascularization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Obesity is a chronic disease and a serious health problem that leads to increased prevalence of diabetes, hypertension, dyslipidemia and gallbladder disease. OBJECTIVE: To evaluate the efficacy of orlistat for weight loss and improved lipid profile compared to placebo in obese patients with hypercholesterolemia, treated over a period of 6 months. METHODOLOGY: In a 6-month, multicenter (10 centers in Portugal), double-blind, parallel, placebo-controlled study, 166 patients, aged 18-65 years, body mass index (BMI) > or = 27 kg/m2, LDL cholesterol > 155 mg/dl, were randomized to a reduced calorie diet (600 kcal/day deficit) plus orlistat three times a day or placebo. Exclusion criteria included triglycerides > 400 mg/dl, severe cardiovascular disease, uncontrolled hypertension, type 1 or 2 diabetes under pharmacological treatment, and gastrointestinal or pancreatic disease. RESULTS: The mean difference in weight from baseline was 5.9% (5.6 kg) in the orlistat group vs. 2.3% (2.2 kg) in the placebo group. In the orlistat group 49% of patients achieved 5-10% weight loss and 8.8% achieved > 10%. The orlistat group showed a significant reduction in total and LDL cholesterol, with similar changes for HDL in both treatment groups. The frequency of gastrointestinal adverse events was slightly higher in the orlistat group than in the placebo group, leading to discontinuation in 7 patients. CONCLUSION: Treatment with orlistat plus a reduced calorie diet for 6 months achieved significant reductions in weight, BMI and lipid parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Adults with repaired tetralogy of Fallot (TOF) may be at risk for progressive right ventricular (RV) dilatation and dysfunction, which is commonly associated with arrhythmic events. In frequently volume-overloaded patients with congenital heart disease, tissue Doppler imaging (TDI) is particularly useful for assessing RV function. However, it is not known whether RV TDI can predict outcome in this population. OBJECTIVE: To evaluate whether RV TDI parameters are associated with supraventricular arrhythmic events in adults with repaired TOF. METHODS: We studied 40 consecutive patients with repaired TOF (mean age 35 +/- 11 years, 62% male) referred for routine echocardiographic exam between 2007 and 2008. The following echocardiographic measurements were obtained: left ventricular (LV) ejection fraction, LV end-systolic volume, LV end-diastolic volume, RV fractional area change, RV end-systolic area, RV end-diastolic area, left and right atrial volumes, mitral E and A velocities, RV myocardial performance index (Tei index), tricuspid annular plane systolic excursion (TAPSE), myocardial isovolumic acceleration (IVA), pulmonary regurgitation color flow area, TDI basal lateral, septal and RV lateral peak diastolic and systolic annular velocities (E' 1, A' 1, S' 1, E' s, A' s, S' s, E' rv, A' rv, S' rv), strain, strain rate and tissue tracking of the same segments. QRS duration on resting ECG, total duration of Bruce treadmill exercise stress test and presence of exercise-induced arrhythmias were also analyzed. The patients were subsequently divided into two groups: Group 1--12 patients with previous documented supraventricular arrhythmias (atrial tachycardia, fibrillation or flutter) and Group 2 (control group)--28 patients with no previous arrhythmic events. Univariate and multivariate analysis was used to assess the statistical association between the studied parameters and arrhythmic events. RESULTS: Patients with previous events were older (41 +/- 14 vs. 31 +/- 6 years, p = 0.005), had wider QRS (173 +/- 20 vs. 140 +/- 32 ms, p = 0.01) and lower maximum heart rate on treadmill stress testing (69 +/- 35 vs. 92 +/- 9%, p = 0.03). All patients were in NYHA class I or II. Clinical characteristics including age at corrective surgery, previous palliative surgery and residual defects did not differ significantly between the two groups. Left and right cardiac chamber dimensions and ventricular and valvular function as evaluated by conventional Doppler parameters were also not significantly different. Right ventricular strain and strain rate were similar between the groups. However, right ventricular myocardial TDI systolic (Sa: 5.4+2 vs. 8.5 +/- 3, p = 0.004) and diastolic indices and velocities (Ea, Aa, septal E/Ea, and RV free wall tissue tracking) were significantly reduced in patients with arrhythmias compared to the control group. Multivariate linear regression analysis identified RV early diastolic velocity as the sole variable independently associated with arrhythmic history (RV Ea: 4.5 +/- 1 vs. 6.7 +/- 2 cm/s, p = 0.01). A cut-off for RV Ea of < 6.1 cm/s identified patients in the arrhythmic group with 86% sensitivity and 59% specificity (AUC = 0.8). CONCLUSIONS: Our results suggest that TDI may detect RV dysfunction in patients with apparently normal function as assessed by conventional echocardiographic parameters. Reduction in RV early diastolic velocity appears to be an early abnormality and is associated with occurrence of arrhythmic events. TDI may be useful in risk stratification of patients with repaired tetralogy of Fallot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os autores descrevem o caso clínico de uma doente que se encontrava sob dupla antiagregação plaquetária com hemotórax traumático maciço e choque hemorrágico, no Serviço de Urgência do nosso hospital. Foi submetida a uma toracotomia de emergência, durante a qual se verificou instabilidade hemodinâmica grave. No pós-operatório, observou-se boa evolução clínica com alta para o domicílio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have shown that a ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus (E/E') of > 15, obtained by tissue Doppler imaging (TDI), correlates with left ventricular filling pressure. OBJECTIVE: The aim of our study was to assess whether E/E' provides prognostic information in patients with dilated cardiomyopathy. METHODS: We studied 33 patients with dilated cardiomyopathy and mean ejection fraction of 31%. All the patients underwent routine two-dimensional and Doppler echocardiographic examination and TDI to determine early peak velocity of the mitral annulus. Pro-B-type natriuretic peptide (pro-BNP) and peak oxygen consumption (VO2max) were also measured. Patients were divided into two groups according to the value of E/E': Group I (n = 15 patients) with E/E' > or = 15 and Group II (n = 18 patients) with E/E' < 15. Patients were followed for 12+/-4 months; new hospital admission due to heart failure, heart transplantation and death were considered as cardiac events. RESULTS: There were significant differences between the two groups in conventional two-dimensional echocardiographic measurements (dimensions and ejection fraction) and Doppler parameters (mitral inflow). With regard to mitral annular velocities obtained by TDI at two different points (septum and lateral wall), the E', A' and S' velocities differed significantly between the two groups, with lower velocities in Group I. Systolic velocity measured in the lateral portion of the mitral annulus showed the most significant difference: Group I - 4.46 cm/sec versus Group II - 7.19 cm/sec, p < 0.00001. Pro-BNP was 5622 pg/ml in Group I, and 1254 pg/ml in Group II, p = 0.004. VO2 max was significantly different between the two groups: Group I - 17.6 ml/kg/min versus Group II - 22.8 ml/kg/min, p = 0.004. During follow-up, events were more common in Group I, with 9 patients (60%) having events, while in Group II, the event rate was 11.1% (2 patients), p = 0.004. CONCLUSION: The ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus is a powerful predictor of clinical outcome. Lower velocities of mitral annulus on TDI are expected in patients with E/E' > or = 15. Systolic velocities of under 5 cm/sec measured in the lateral portion of the mitral annulus appeared to be strongly related to prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O método de união com ligações adesivas está cada vez mais a ser utilizado na conceção de estruturas mecânicas, por causa das vantagens significativas desta técnica em comparação com as ligações tradicionais. De facto, as juntas com ligação adesiva estão sob investigação intensa há bastante tempo. Entre as vantagens, destaca-se a redução de peso e possibilidade de unir diferentes materiais, incluindo compósitos, sem danificar as estruturas a ligar. Os adesivos comerciais variam desde resistentes e frágeis (por exemplo, Araldite® AV138) a menos resistentes e dúcteis (por exemplo, Araldite® 2015). Uma nova família de adesivos de poliuretano combina elevada resistência e ductilidade (por exemplo, Sikaforce® 7888). Este trabalho compara o desempenho à tração dos três adesivos supracitados, em juntas de alumínio (Al6082-T651) de sobreposição simples e dupla, com variação dos valores de comprimento de sobreposição (LO). A análise numérica de modelos de dano coesivo (MDC) foi realizada para analisar as tensões de arrancamento (oy) e as de corte (txy) na camada adesiva, para estudar a variável de dano do MDC durante o processo de rotura e para avaliar a capacidade MDC na previsão da resistência da junta. A análise da resistência e da variável de dano ajudou na compreensão das diferenças entre os adesivos no que se refere ao processo de rotura e resistência da junta. Observou-se que as juntas de sobreposição dupla apresentam uma distribuição de tensões bastante mais favorável relativamente às juntas de sobreposição simples, principalmente devido à eliminação da flexão do substrato interior. Como resultado, a resistência destas juntas foi tipicamente superior ao dobro da observada para as juntas de sobreposição simples, com exceção de algumas configurações de junta em que houve plastificação extensa ou mesmo rotura dos substratos por tração. O trabalho proposto permitiu também concluir que as previsões MDC são tipicamente precisas, e qual a família de adesivos é mais adequada para cada configuração de junta, com a clara vantagem para o Sikaforce® 7888. Como resultado deste trabalho, foram propostas diretrizes de conceção para juntas adesivas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their detrimental effects on human health, scientific interest in ultrafine particles (UFP), has been increasing but available information is far from comprehensive. Children, who represent one of the most susceptible subpopulation, spend the majority of time in schools and homes. Thus, the aim of this study is to (1) assess indoor levels of particle number concentrations (PNC) in ultrafine and fine (20–1000 nm) range at school and home environments and (2) compare indoor respective dose rates for 3- to 5-yr-old children. Indoor particle number concentrations in range of 20–1000 nm were consecutively measured during 56 d at two preschools (S1 and S2) and three homes (H1–H3) situated in Porto, Portugal. At both preschools different indoor microenvironments, such as classrooms and canteens, were evaluated. The results showed that total mean indoor PNC as determined for all indoor microenvironments were significantly higher at S1 than S2. At homes, indoor levels of PNC with means ranging between 1.09 × 104 and 1.24 × 104 particles/cm3 were 10–70% lower than total indoor means of preschools (1.32 × 104 to 1.84 × 104 particles/cm3). Nevertheless, estimated dose rates of particles were 1.3- to 2.1-fold higher at homes than preschools, mainly due to longer period of time spent at home. Daily activity patterns of 3- to 5-yr-old children significantly influenced overall dose rates of particles. Therefore, future studies focusing on health effects of airborne pollutants always need to account for children’s exposures in different microenvironments such as homes, schools, and transportation modes in order to obtain an accurate representation of children overall exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Num grupo de 64 doentes de uma Unidade de Cuidados Intensivos, 24 dos quais submetidos a ventilação mecânica, foi determinada a influência da modificação da volémia nas características do Doppler cardíaco, através da negativização do balanço hídrico e correspondente modificação da pressão venosa central. Com a modificação da volémia, a relação E/A do fluxo transvalvular mitral mostrou uma tendência para reduzir, o tempo de desaceleração da onda E mitral para diminuir, o tempo de relaxamento isovolumétrico para aumentar, e a veia cava inferior reduziu o seu diâmetro expiratório e aumentou o valor do colapso inspiratório. Não se observou uma correlação significativa entre os valores das variáveis estudadas e a modificação da volémia, inclusivamente entre a pressão venosa central e o balanço hídrico. A modificação da volémia em doentes críticos modifica as características de determinados parâmetros de ecocardiografia- -Doppler, mas não é possível predizer a magnitude dessa variação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apresenta-se um caso clínico de dissecção da aorta abdominal - tipo B - diagnosticada por eco-Doppler e tomografia axial computorizada (TC). Discute-se o interesse do eco-Doppler no diagnóstico de dissecção da aorta abdominal e na avaliação do envolvimento arterial visceral. É ainda um método útil no follow-up dos doentes com terapêutica conservadora.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Patient-controlled epidural analgesia with low concentrations of anesthetics is effective in reducing labor pain. The aim of this study was to assess and compare two ultra-low dose regimens of ropivacaine and sufentanil (0.1% ropivacaine plus 0.5 μg.ml-1 sufentanil vs. 0.06% ropivacaine plus 0.5 μg.ml-1 sufentanil) on the intervals between boluses and the duration of labor. MATERIAL AND METHODS: In this non-randomized prospective study, conducted between January and July 2010, two groups of parturients received patient-controlled epidural analgesia: Group I (n = 58; 1 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil) and Group II (n = 57; 0.6 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil). Rescue doses of ropivacaine at the concentration of the assigned group without sufentanil were administered as necessary. Pain, local anesthetic requirements, neuraxial blockade characteristics, labor and neonatal outcomes, and maternal satisfaction were recorded. RESULTS: The ropivacaine dose was greater in Group I (9.5 [7.7-12.7] mg.h-1 vs. 6.1 [5.1-9.8 mg.h-1], p < 0.001). A time increase between each bolus was observed in Group I (beta = 32.61 min, 95% CI [25.39; 39.82], p < 0.001), whereas a time decrease was observed in Group II (beta = -1.40 min, 95% CI [-2.44; -0.36], p = 0.009). The duration of the second stage of labor in Group I was significantly longer than that in Group II (78 min vs. 65 min, p < 0.001). CONCLUSIONS: Parturients receiving 0.06% ropivacaine exhibited less evidence of cumulative effects and exhibited faster second stage progression than those who received 0.1% ropivacaine.