963 resultados para Tricuspid Valve


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A forty eight year old woman, who had undergone mitral comissurotomy and subsequently developed early restenosis, presented with major comissural fusion and verrucous lesions on the cuspid edges of the mitral valve, with normal subvalvar apparatus. Patient did well for the first six months after surgery when she began to present dyspnea on light exertion. A clinical diagnosis of restenosis was made, which was confirmed by an echocardiogram and cardiac catheterization. She underwent surgery, and a stenotic mitral valve with verrucous lesions suggesting Libman-Sacks' endocarditis was found. Because the diagnosis of systemic lupus erythematosus (SLE) had not been confirmed at that time, a bovine pericardium bioprosthesis (FISICS-INCOR) was implanted. The patient did well in the late follow-up and is now in NYHA Class I .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report the result of patients treated with IV methylprednisolone divided into three groups and compare their follow-up during the last 12 years. METHODS: Seventy children with active rheumatic carditis (76 episodes) in heart failure Class III and IV (NYHA) were studied. The diagnosis was based on modified Jones' criteria. After ruling out infections and strongyloidiasis, treatment with IV methylprednisolone bolus was started three times a week until the laboratory tests became negative. Patients were divided into 3 groups, according to the time of hospital admittance: Groups 1, 2 and 3, comprising of 40, 18 and 12 children, respectively. RESULTS: Eighteen children in Group 1 (45%) were in their 1st attack: 2 series of pulsetherapy were used in 10 (25%), 3 in 9 (23%) and 4 in 21 (52%). In Group 2, 14 cases (77%) were in their 1st attack: 2 series were used in 7 (39%), 4 in 9 (50%) and 5 in 2 (11%). The echocardiogram showed a flail mitral valve in 12 (66%) of these patients (1 death occurred after mitral valvoplasty). In Group 3, 6 patients needed 5 or more series of pulsetherapy and a flail mitral valve was present in 5 (41%). One child underwent mitral valve replacement while still in the active phase, after 8 series of pulsetherapy, and another died. The number of patients who needed 5 or more series was significantly higher in Group 3. CONCLUSION: There were variations in the presentation and evolution of the cases during these 12 year. The established pulsetherapy protocol continues to be useful to treat severe cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVE: To evaluate by Doppler echocardiography (DE) early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A) and 25 with CD4 cell count <500/mm³ (Group B), were analyzed. CD4 cells were counted and matched with structural data and systolic and diastolic function of the left ventricle (LV), as analyzed by DE. The results were compared with those obtained in 47 healthy individuals (Group C). RESULTS: 8% of patients in Group B had mild pericardial effusion; 31.5% showed decreased systolic function of the LV, and 12% had moderate mitral regurgitation. A wave velocity from the mitral inflow was different among the 3 groups, being higher in Group B, where the deceleration time of the E wave of the mitral inflow and the E/A ratio were significantly lower with a normal value of the isovolumic relaxation time (IVRT). CONCLUSION: HIV-positive patients with a CD4 cell count >500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³), had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE - To assess neonates with aortic stenosis with early decompensation operated upon. (LCO) (CHF). METHODS - A and retrospective study analyzing 6 neonates with LCO, group I (GI), and 12 neonates with CHF, group II (GII). Clinical radiographic, electrocardiographic and echocardiographic findings also provided comparative bases for the study, as did surgical and evolutional findings. RESULTS - The mean ages at hospitalization and surgery (p = 0.0031) were 14.3 and 14.8 days in GI and 35.4 and 42.8 days in GII, respectively. Cardiac murmurs were more intense in GII (p = 0.0220). The aortic ring was smaller in GI (8.0 ± 2.5mm) as compared to GII (11.4±1.4mm) (p = 0.2882). Ventricular function was reduced to 18±5.5% and 33.3±7.6% in GI and GII, respectively (p = 0.0162). Aortic atresia, however, was present only in 2 neonates in GI. Five of 6 patients in GI died but all patients in GII survived (p=0.0007). In the latter group, 84.6% of the patients were in functional class I (FC-I) in the long-term follow-up, with moderate residual lesions in 6 neonates, discrete residual lesions in 4, and reoperation in 2. CONCLUSION - Aortic stenosis is a severe anomaly of the neonate, whose immediate evolution depends on the pre-operative anatomic and functional findings, and the late evolution essentially depends on the anatomic features of the valve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the sphygmomanometers calibration accuracy and the physical conditions of the cuff-bladder, bulb, pump, and valve. METHODS: Sixty hundred and forty five aneroid sphygmomanometers were evaluated, 521 used in private practice and 124 used in hospitals. Aneroid manometers were tested against a properly calibrated mercury manometer and were considered calibrated when the error was <=3mm Hg. The physical conditions of the cuffs-bladder, bulb, pump, and valve were also evaluated. RESULTS: Of the aneroid sphygmomanometers tested, 51% of those used in private practice and 56% of those used in hospitals were found to be not accurately calibrated. Of these, the magnitude of inaccuracy ranged from 4 to 8mm Hg in 70% and 51% of the devices, respectively. The problems found in the cuffs - bladders, bulbs, pumps, and valves of the private practice and hospital devices were bladder damage (34% vs. 21%, respectively), holes/leaks in the bulbs (22% vs. 4%, respectively), and rubber aging (15% vs. 12%, respectively). Of the devices tested, 72% revealed at least one problem interfering with blood pressure measurement accuracy. CONCLUSION: Most of the manometers evaluated, whether used in private practice or in hospitals, were found to be inaccurate and unreliable, and their use may jeopardize the diagnosis and treatment of arterial hypertension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the early outcome of mitral valve prostheses implantation and left ventricular remodeling in 23 patients with end-stage cardiomyopathy and secondary mitral regurgitation (NYHA class III and IV). METHODS: Mitral valvular prosthesis implantation with preservation of papillary muscles and chordae tendinae, and plasty of anteriun cuspid for remodeling of the left ventricle. RESULTS: The surgery was performed in 23 patients, preoperative ejection fraction (echocardiography) varied from 13% to 44% (median: 30%). In 13 patients associated procedures were performed: myocardial revascularization (9), left ventricle plicature repair (3) and aortic prosthese implantation (1). Early deaths (2) occurred on the 4th PO day (cardiogenic shock) and on the 20th PO day (upper gastrointestinal bleeding), and a late death in the second month PO (ventricular arrhythmia). Improvement occurred in NYHA class in 82.6% of the patients (P<0.0001), with a survival rate of 86.9% (mean of 8.9 months of follow-up). CONCLUSION: This technique offers a promising therapeutic alternative for the treatment of patients in refractory heart failure with cardiomyopathy and secondary mitral regurgitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A patient with tertiary syphilis presenting with bilateral coronary ostial lesions and aortic regurgitation underwent surgical reconstruction of the coronary ostia by the anterior approach with autogenous saphenous vein grafting and substitution of the aortic valve with a bovine bioprosthesis. The procedure was easily performed and had good outcomes both early and late. The rarity of the association of a lesion in both coronary ostia with aortic regurgitation in syphilis and the surgical technique employed are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess by Doppler echocardiography the structural and functional alterations of rat heart with surgical induced extensive myocardial infarction. METHODS: Five weeks after surgical ligature of the left coronary artery, 38 Wistar-EPM rats of both sexes, 10 of them with extensive infarction, undergone anatomical and functional evaluation by Doppler echocardiography and then euthanized for anatomopathological analysis. RESULTS: Echocardiography was 100% sensible and specific to anatomopathological confirmed extensive miocardial infarction. Extensive infarction lead to dilatation of left ventricle (diastolic diameter: 0.89cm vs.0.64cm; systolic: 0.72cm vs. 0.33cm) and left atrium (0.55cm vs. 0.33cm); thinning of left ventricular anterior wall (systolic: 0.14cm vs. 0.23cm, diastolic: 0.11cm vs. 0.14cm); increased mitral E/ A wave relation (6.45 vs. 1.95). Signals of increased end diastolic ventricle pressure, B point in mitral valve tracing in 62.5% and signs of pulmonary hypertension straightening of pulmonary valve (90%) and notching of pulmonary systolic flow (60%) were observed in animals with extensive infarction. CONCLUSION: Doppler echocardiography has a high sensitivity and specificity for detection of chronic extensive infarction. Extensive infarction caused dilatation of left cardiac chambers and showed in Doppler signals of increased end diastolic left ventricular pressure and pulmonary artery pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identifity characteristics associated with complications during pregnancy and puerperium in patients with rheumatic mitral stenosis. METHODS: Forty-one pregnant women (forty-five pregnancies) with mitral stenosis, followed-up from 1991 to 1999 were retrospectively evaluated. Predictor variables: the mitral valve area (MVA), measured by echocardiogram, and functional class (FC) before pregnancy (NYHA criteria).Maternal events: progression of heart failure, need for cardiac surgery or balloon mitral valvulotomy, death, and thromboembolism. Fetal/neonatal events: abortion, fetal or neonatal death, prematurity or low birth weight (<2,500g), and extended stay in the nursery or hospitalization in newborn ICU. RESULTS: The mean ± SD of age of the patients was 28.8±4.6 years. The eventful and uneventful patients were similar in age and percentage of first pregnancies. As compared with the level 1 MVA, the relative risk (RR) of maternal events was 5.5 (95% confidence interval (CI) =0.8-39.7) for level 2 MVA and 11.4 (95% CI=1.7-74.5) for level 3 MVA. The prepregnancy FC (FC > or = II and III versus I) was also associated with a risk for maternal events (RR=2.7; 95% CI=1.4-5.3).MVA and FC were not importantly associated with these events, although a smaller frequency of fetal/neonatal events was observed in patients who had undergone balloon valvulotomy. CONCLUSION: In pregnant women with mitral stenosis, the MVA and the FC are strongly associated with maternal complications but are not associated with fetal/neonatal events. Balloon mitral valvulotomy could have contributed to reducing the risks of fetal/neonatal events in the more symptomatic patients who had to undergo this procedure during pregnancy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate cardiac findings in 31 Noonan syndrome patients. METHODS: Thirty-one (18 males and 13 females)patients from 26 families affected with Noonan's syndrome were evaluated from the cardiac point of view with electrocardiography and echodopplercardiography. RESULTS: Twenty patients had some type of cardiac abnormality. The most frequent was pulmonary valve stenosis followed by hypertrophic myocardiopathy, commonly associated with valve defects. Upper deviation of the QRS axis was observed in 80% of these patients. CONCLUSION: In view of the high frequency and diversity of cardiac abnormalities present in Noonan syndrome, cardiac evaluation with electrocardiography and echocardiography should be performed in all patients diagnostically suspected of having this disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate prior mitral surgical commissurotomy and echocardiographic score influence on the outcomes and complications of percutaneous mitral balloon valvuloplasty. METHODS: We performed 459 complete mitral valvuloplasty procedures. Four hundred thirteen were primary valvuloplasty and 46 were in patients who had undergone prior surgical commissurotomy. The prior commissurotomy group was older, had higher echo scores, and a tendency toward a higher percentage of atrial fibrillation. RESULTS: When the groups were compared with each other, no differences were found in pre- and postprocedure mean pulmonary artery pressure, mean mitral gradient, mitral valve area, and mitral regurgitation . Because we found no significant differences, we subdivided the entire group based on echo scores, those with echo scores <=8 and those with echo scores >8 the mitral valve area being higher in the <=8 echo score group 2.06±0.42 versus 1.90±0.40cm² (p=0.0090) in the >8 echo score group. CONCLUSION: Dividing the groups based on echo score revealed that the higher echo score group had smaller mitral valve areas postvalvuloplasty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a case report of a double-outlet left ventricle associated with tricuspid atresia and hypoplasia of the right ventricle, diagnosed during echocardiography with color-flow imaging, in a three-month-old child who presented with fatigue and cyanosis. The child underwent palliative pulmonary arterial banding without an invasive procedure, and showed sustained improvement during follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the immediate results of percutaneous mechanical mitral commissurotomy. METHODS: Thirty patients underwent percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome from 8/11/99 to 2/4/00. Mean age was 30.7 years, and 73.3% were women. With regards to functional class, 63.3% were class III, and 36.7% were class IV. The echocardiographic score had a mean value of 7.5± 1.8. RESULTS: The mitral valve area increased from 0.97±0.15cm² to 2.16±0.50cm² (p>0.0001). The mean diastolic gradient decreased from 17.9±5.0mmHg to 3.2±1.4mmHg. The mean left atrial pressure decreased from 23.6±5.4mmHg to 8.6±3.1mmHg, (p>0.0001). Systolic pressure in the pulmonary artery decreased from 52.7±18.3mmHg to 32.2±7.4mmHg. Twenty-nine cases were successful. One patient developed severe mitral regurgitation. Interatrial septal defect was observed and one patient. One patient had cardiac tamponade due to left ventricular perforation. No deaths occurred. CONCLUSION: This method has proven to be safe and efficient in the treatment of rheumatic mitral stenosis. The potential advantage is that it can be used multiple times after sterilization, which decreases procedural costs significantly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Few patients with corrected transposition of the great arteries survive past 50 years of age because of the association with congenital defects, development of total atrioventricular block, and right ventricular dysfunction. We report the case of a male patient with dextrocardia in situs solitus and corrected transposition of the great arteries associated with a wide atrial septal defect and severe pulmonary valvar and subvalvar stenoses. The patient also developed a large aneurysm on the pulmonary artery, total atrioventricular block diagnosed 8 years earlier, symptoms of dysfunction of the systemic ventricle in the previous 2 years, insufficiency of the left atrioventricular valve, and aortic regurgitation. Despite all these associated anomalies, the patient developed class III cardiac decompensation only at the age of 68 years, which makes this case a rarity. The patient was clinically treated, and was discharged from the hospital in good condition.