981 resultados para Test-problem Generator
Resumo:
“Cork taint” is a major problem in wine industry and is caused by contamination of wines. This contamination is usually attributed to wine cork stoppers and 2,4,6-trichloroanisole (2,4,6-TCA) is one of the compounds mostly associated to this off-flavour. In this work, a consumer panel performed “forced choice” triangular tests in order to measure Odour Detection Thresholds (ODT) and Taste Detection Thresholds (TDT) of 2,4,6-TCA in water, hydro-alcoholic solutions (11.5% and 18% ethanol) and white and red wines. A paired preference test was also performed by the panel in order to measure Odour Rejection Threshold (ORT) in white and red wine spiked with 2,4,6-TCA. Results obtained show that the ODT and the TDT for 2,4,6-TCA in water were 0.2 and 0.3 ng/L, respectively. In hydro-alcoholic solutions with 11.5% and 18% ethanol the ODT were 4 and 10 ng/L respectively. In red wine the ODT and the TDT were 0.9 and 1.7 ng/L and in white wine were 1.5 and 1.0 ng/L respectively. ORT for white was 10.4 ng/L and for red wines 16.0 ng/L. These results suggest that although this group of consumers detected very low concentrations of 2,4,6-TCA in wines, they did not reject the wine at these low concentration values.
Resumo:
A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.
Resumo:
A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática
Resumo:
Thesis submitted to the Faculty of Sciences and Technology, New University of Lisbon, for the degree of Doctor of Philosophy in Environmental Sciences
Resumo:
A capacidade de deambulação apresenta um significado bastante importante para a população em geral, uma vez que contribui para a manutenção do estado de saúde e para a reabilitação e melhoria da condição física, de uma forma geral. A amputação de um membro inferior, com ou sem abordagem protésica, impõe, ao amputado, um aumento no gasto energético durante a deambulação. A medição do gasto energético durante a marcha em amputados serve, não só para quantificar o esforço requerido, mas também para comparar a eficácia de diferentes componentes protésicos. Objetivos do estudo - Determinação dos fatores que influenciam a capacidade funcional dos amputados do membro inferior. Perceção do impacto das características pessoais, quadro clínico, hábitos e fatores comportamentais, bem como componentes protésicos no consumo de oxigénio e capacidade de deambulação.
Resumo:
Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.
Resumo:
XSLT is a powerful and widely used language for transforming XML documents. However, its power and complexity can be overwhelming for novice or infrequent users, many of whom simply give up on using this language. On the other hand, many XSLT programs of practical use are simple enough to be automatically inferred from examples of source and target documents. An inferred XSLT program is seldom adequate for production usage but can be used as a skeleton of the final program, or at least as scaffolding in the process of coding it. It should be noted that the authors do not claim that XSLT programs, in general, can be inferred from examples. The aim of Vishnu—the XSLT generator engine described in this chapter—is to produce XSLT programs for processing documents similar to the given examples and with enough readability to be easily understood by a programmer not familiar with the language. The architecture of Vishnu is composed by a graphical editor and a programming engine. In this chapter, the authors focus on the editor as a GWT Web application where the programmer loads and edits document examples and pairs their content using graphical primitives. The programming engine receives the data collected by the editor and produces an XSLT program.
Resumo:
IEEE International Symposium on Circuits and Systems, pp. 2713 – 2716, Seattle, EUA
Resumo:
We used the micro- and macroimmunodiffusion test for the qualitative and quantitative measurement of anti - P. brasiliensis antibodies in serum of patients with paracoccidioidomycosis. All 103 paracoccidioidomycosis sera (100%) were positive in the micro test versus 87% positivity index in the macrotest. All 83 control sera from patients with other diseases were negative in both tests. Titers of the positive sera tended to be higher in the microtest, which revealed sharper and easier to read precipiting bands. Microimmunodiffusion is simple to be performed, requires a minimum amount of reagents and allows the simultaneous testing of 102 sera. It may replace the macrotest specially in laboratories dealing with great serologic routine.
Resumo:
Introduction: Anxiety is a common problem in primary care and specialty medical settings. Treating an anxious patient takes more time and adds stress to staff. Unrecognized anxiety may lead to exam repetition, and impedance of exam performance. Objective: The aim of the study was to examine the anxiety levels of patients who are to undergo diagnostic exams related to cancer diagnostic: PET/CT and mammography. Methods: Two hundred and thirty two patients who undergo PET/CT and one hundred thirteen women who undergo mammography filled out one questionnaire after the procedure to determine their concerns, expectations and perceptions of anxiety. Results: Our results show that the main causes of anxiety in patients who are having a PET/CT is the fear of the procedure itself and fear of the results. Patients who suffered from greater anxiety were those who were scanned during the initial stage of an oncological disease. On the other hand, the diagnostic is the main cause of anxiety in women who are requiring a mammography. 28% of the women reported having experienced pain or intense pain. Conclusions: The performance of diagnostic exams related to cancer diagnostic like a PET/CT and a mammography are important and statistically generators of anxiety. Patients are often poorly informed and present with a range of anxieties that may ultimately affect examination quality. These results provide expertise that can be used in the development of future training programs to integrate post-graduate courses of health professionals.
Resumo:
Introduction: Anxiety is a common problem in primary care and specialty medical settings. Treating an anxious patient takes more time and adds stress to staff. Unrecognised anxiety may lead to exam repetition, image artifacts and hinder the scan performance. Reducing patient anxiety at the onset is probably the most useful means of minimizing artifactual FDG uptake, both fat brown and skeletal muscle uptake, as well patient movement and claustrophobia. The aim of the study was to examine the effects of information giving on the anxiety levels of patients who are to undergo a PET/CT and whether the patient experience is enhanced with the creation of a guideline. Methodology: Two hundred and thirty two patients were given two questionnaires before and after the procedure to determine their prior knowledge, concerns, expectations and experiences about the study. Verbal information was given by one of the technologists after the completion of the first questionnaire. Results: Our results show that the main causes of anxiety in patients who are having a PET/CT is the fear of the procedure itself, and fear of the results. The patients who suffered from greater anxiety were those who were scanned during the initial stage of a disease. No significant differences were found between the anxiety levels pre procedural and post procedural. Findings with regard to satisfaction show us that the amount of information given before the procedure does not change the anxiety levels and therefore, does not influence patient satisfaction. Conclusions: The performance of a PET/CT scan is an important and statistically generator of anxiety. PET/CT patients are often poorly informed and present with a range of anxieties that may ultimately affect examination quality. The creation of a guideline may reduce the stress of not knowing what will happen, the anxiety created and may increase their satisfaction in the experience of having a PET/CT scan.
Resumo:
In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.
Resumo:
The global warming due to high CO2 emission in the last years has made energy saving a global problem nowadays. However, manufacturing processes such as pultrusion necessarily needs heat for curing the resin. Then, the only option available is to apply all efforts to make the process even more efficient. Different heating systems have been used on pultrusion, however, the most widely used are the planar resistances. The main objective of this study is to develop another heating system and compares it with the former one. Thermography was used in spite of define the temperature profile along the die. FEA (finite element analysis) allows to understand how many energy is spend with the initial heating system. After this first approach, changes were done on the die in order to test the new heating system and to check possible quality problems on the product. Thus, this work allows to conclude that with the new heating system a significant reduction in the setup time is now possible and an energy reduction of about 57% was achieved.
Resumo:
Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.