991 resultados para THERMAL LENS SPECTROMETRY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metl oxalate hydrazinates MC2O4·2 N2H4 where M=Mg, Mn, Fe, Co, Ni, Cu, Zn and Cd have been prepared and characterised by chemical analysis and infrared spectra. Thermal reactivity and decomposition of these oxalato complexes have been studied using thermogravimetry and differential thermal analysis. Hydrazinates of Mn, Fe, Co, Ni and Cu oxalates exhibit autocatalytic decomposition behaviour whereas the others do not. This phenomenon can be attributed to the presence of a bridged hydrazine as well as the thermal stability of the anhydrous metal oxalates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract It is widely considered that high pressure processing (HPP) results in better retention of micronutrients and phytochemicals compared to thermal pasteurization (TP), although some studies indicate that this may not be true in all cases. The aims of this study were (1) to objectively compare the effects of HPP under commercial processing conditions with thermal pasteurization (TP) on the stability of phenolic antioxidants in strawberries following processing and during storage and (2) to evaluate the influence of varietal differences and hence differences in biochemical composition of strawberries on the stability of phenolic antioxidants. Strawberry puree samples from cultivars Camarosa, Rubygem, and Festival were subjected to HPP (600 MPa/20 °C/5 min) and TP (88 °C/2 min). The activities of oxidative enzymes were evaluated before and after processing. Furthermore, the antioxidant capacity (total phenolic content (TPC), oxygen radical absorbance capacity (ORAC), and ferric reducing antioxidant power (FRAP)) and individual anthocyanins (by HPLC) were determined prior to and following processing and after three months of refrigerated storage (4 °C). Depending on the cultivar, HPP caused 15–38% and 20–33% inactivation of polyphenol oxidase and peroxidase, respectively, compared to almost complete inactivation of these enzymes by TP. Significant decreases (p < 0.05) in ORAC, FRAP, TPC and anthocyanin contents were observed during processing and storage of both HPP and TP samples. Anthocyanins were the most affected with only 19–25% retention after three months of refrigerated storage (4 °C). Slightly higher (p < 0.05) loss of TPC and antioxidant capacity were observed during storage of HPP samples compared to TP. Industrial Relevance: The results of the study demonstrated that both high pressure processing and thermal pasteurization result in high retention of phenolic phytochemicals in strawberry products. Under the conditions investigated, high pressure processing did not result in a better retention of phenolic phytochemicals compared to thermal pasteurization. In fact, a slightly higher loss of total polyphenol content and antioxidant capacity were observed during refrigerated storage of HPP processed samples. Our results showed that, high pressure processing may not always be a better alternative to thermal processing for strawberry puree processing if the main objective is better retention of phenolic antioxidants. However, it should be noted that other quality attributes such as sensory properties, where distinct advantages of HPP are expected, were outside the scope of this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inorganic–organic clays (IOCs), clays intercalated with both organic cations such as cationic surfactants and inorganic cations such as metal hydroxy polycations have the properties of both organic and pillared clays, and thereby the ability to remove both inorganic and organic contaminants from water simultaneously. In this study, IOCs were synthesised using three different methods with different surfactant concentrations. Octadecyltrimethylammonium bromide (ODTMA) and hydroxy aluminium ([Al13O4 (OH)24(H2O)12]7+ or Al13) are used as the organic and inorganic modifiers (intercalation agents). According to the results, the interlayer distance, the surfactant loading amount and the Al/Si ratio of IOCs strictly depend on the intercalation method and the intercalation agent ratio. Interlayers of IOCs synthesised by intercalating ODTMA before Al13 and IOCs synthesised by simultaneous intercalation of ODTMA and Al13 were increased with increasing the ODTMA concentration used in the synthesis procedure and comparatively high loading amounts could be observed in them. In contrast, Al/Si decreased with increasing ODTMA concentration in these two types of IOCs. The results suggest that Al-pillars can be fixed within the interlayers by calcination and any increment in the amount of ODTMA used in the synthesis procedure did not affect the interlayer distance of the IOCs. Overall the study provides valuable insights into the structure and properties of the IOCs and their potential environmental applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the late 1990s, the International Contact Lens Prescribing Survey Consortium has prospectively gathered information about 285,000 contact lens fits from more than 50 countries. This article presents our 14th annual summary of current trends published in Contact Lens Spectrum. With only minor differences in the distribution of our surveys among markets, we have continued to adopt the same approach throughout the past 18 years. Through national coordinators, we approach contact lens prescribers in each country and ask them to record information about the first 10 patients whom they fit with contact lenses after receipt of our survey form. The information collected is generic, and respondents are weighted to reflect the volume of contact lens fits undertaken by each. For this 2014 report, we present information about 25,179 contact lens fits from 32 countries...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To eye care practitioners, citation metrics may seem to be a somewhat esoteric and irrelevant concept, far removed from the realities or real world, day-to-day clinical practice. However, quantitative analysis of the published literature is becoming increasingly important, and a beautiful example of this is presented in this issue of the Journal of Optometry. My former PhD student, Genís Cardona, has teamed up with Joan Sanz to undertake a thorough and telling analysis of current worldwide publishing trends in the contact lens field. When held in the mirror, this work reflects the growing contributions from Spanish researchers to the field...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Straylight, lens yellowing and ocular aberrations were assessed in a group of people with type 1 diabetes and in an age matched control group. Most of the former had low levels of neuropathy. Relative to the control group, the type 1 diabetes group demonstrated greater straylight, greater lens yellowing, and differences in some higher-order aberration co-efficients without significant increase in root-mean-square higher-order aberrations. Differences between groups did not increase significantly with age. The results are similar to the findings for ocular biometry reported previously for this group of participants, and suggest that age-related changes in the optics of the eyes of people with well-controlled diabetes need not be accelerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal degradation of polystyrene peroxide was carried out using differential scanning calorimetry. The activation energy (E) was found to be 136 kJ mole–1 at all extents of decomposition. TheE value was found to correspond to-O-O-dissociation. The order of reaction was found to decrease from 2 to 1 as the decomposition progresse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal polymerization of acrylamide has been followed by the DSC technique, and the activation energy (E) values at different stages of the fraction polymerized (a) have been determined from the exotherm of the thermograms obtained. The trend of variation of E with agr shows that E remains constant up to agr = 0.5 and decreases with a further increase in agr. A close look at the composite nature of the exotherms, agr-t, and agr-T curves shows that the polymerization of acrylamide involves two processes. The first process is the formation of linear polyacrylamide and the second is the simultaneous cross-linking of the linear chains together with the formation of linear polyacrylamide. Experiments such as NH3 detection by differential thermal analysis techniques and annealing studies have been made to shed further light on the polymerization process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To document contact lens prescribing patterns in the United States between 2002 and 2014. Methods A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. Results Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. Conclusions This survey has revealed prescribing trends and preferences in the United States over the past 13 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kinetics of the thermal decomposition of anhydrous barium zirconyl oxalate and a carbonate intermediate have been studied. Decomposition of the anhydrous oxalate, though it could be explained based on a contracting-cube model, is quite complex. Kinetics of decomposition of the intermediate carbonate Ba2Zr2O5CO3 is greatly influenced by thermal effects during its formation. (agr-t) curves are sigmoidal and obey a power law equation followed by first order decay. Presence of carbon in the vacuum-prepared carbonate has a strong deactivating effect. Decomposition of the carbonate is accompanied by growth in particle size of the product barium zirconate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efron, Morgan and Woods share the findings of their latest annual survey of Australian contact lens prescribing habits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal decomposition of ethyl and isopropyl amine perchlorates has been studied by methods such as DTA, TG, isothermal weight loss measurements and the decomposition products have been analyzed in a mass spectrometer. Activation energy values for thermal decomposition have been calculated fromagr-t plots. The proton transfer dissociation mechanism proposed for the thermal decomposition of ammonium perchlorate (AP) has been extended to explain the decomposition products of these twosubstituted amine perchlorates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have been collecting data on worldwide contact lens prescribing habits for almost 20 years. Over this time period, we have amassed prospective information about 315,000 contact lens fits in 59 countries. This article marks our 15th report in Contact Lens Spectrum and features a breakdown of more than 23,000 contact lens fits in 34 markets. As in previous years, our international network of coordinators distributed survey forms to eyecare practitioners in their market who then recorded generic information about the first 10 patients fit with contact lenses after receipt. Information is gathered about patient age and gender; whether the contact lenses are prescribed as a new fit or a refit; contact lens material, design, and replacement frequency; number of intended days per week of use; wearing modality; and care system. Contact lens fits are weighted to reflect the number of fits undertaken by each eyecare practitioner. The study data were entered and processed at the University of Manchester and at the University of Waterloo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare lens dimensions and refractive index distributions in type 1 diabetes and age-matched control groups. Methods: There were 17 participants with type 1 diabetes, consisting of two subgroups (7 young [23 ± 4 years] and 10 older [54 ± 4 years] participants), with 23 controls (13 young, 24 ± 4 years; 10 older, 55 ± 4 years). For each participant, one eye was tested with relaxed accommodation. A 3T clinical magnetic resonance imaging scanner was used to image the eye, employing a multiple spin echo (MSE) sequence to determine lens dimensions and refractive index profiles along the equatorial and axial directions. Results: The diabetes group had significantly smaller lens equatorial diameters and larger lens axial thicknesses than the control group (diameter mean ± 95% confidence interval [CI]: diabetes group 8.65 ± 0.26 mm, control group 9.42 ± 0.18 mm; axial thickness: diabetes group 4.33 ± 0.30 mm, control group 3.80 ± 0.14 mm). These differences were also significant within each age group. The older group had significantly greater axial thickness than the young group (older group 4.35 ± 0.26 mm, young group 3.70 ± 0.25 mm). Center refractive indices of diabetes and control groups were not significantly different. There were some statistically significant differences between the refractive index fitting parameters of young and older groups, but not between diabetes and control groups of the same age. Conclusions: Smaller lens diameters occurred in the diabetes groups than in the age-matched control groups. Differences in refractive index distribution between persons with and without diabetes are too small to have important effects on instruments measuring axial thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive measurements of the age dependence of refractive index distribution in human eye lenses in vitro using a novel X-ray Talbot Interferometry method. In their paper, the authors make frequent reference to our own work in which we employed magnetic resonance imaging (MRI) to make similar non-invasive measurements of the refractive index distribution in the human eye lens [2, 3]. Prior to the current work, ours was the only method for making such measurements both non-invasively and without prior assumptions about the shape of the refractive index distribution. For this reason, the latest work is to be welcomed. However at several points in the paper, Pierscionek et al. [1] make statements about our technique which are factually incorrect...