949 resultados para Surfaces in the 3-dimensional Sphere


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. In dental rehabilitations that involve implants, the number of implants is sometimes smaller than the number of lost teeth. This fact can affect the biomechanical behavior and success of the implants.Purpose. The purpose of this study was to investigate the mechanical behavior of different implant positions in the rehabilitation of the anterior maxilla.Material and methods. Three-dimensional models of the maxilla were created based on computed tomography images for 3 different anterior prosthetic rehabilitations. In group IL, the implants were placed in the lateral incisor positions with pontics in the central incisor positions; in group IC, the implants were in the central incisor positions with cantilevers in the lateral incisor positions; and, in group ILIC, one implant was in a lateral incisor position and one was in a central incisor position, with a pontic and a cantilever in the remaining positions. A 150 N load was distributed and applied at the center of the palatal surface of each tooth at a 45-degree angle to the long axis of the tooth. The resulting stress-strain distribution was analyzed for each group.Results. The lowest displacement of the prosthetic structure was observed in group IC, although the same group exhibited the largest displacement of the bone tissue. In the bone tissue, the von Mises stress was mainly observed in the cortical bone in all groups. The maximum value of the von Mises stress shown in the cortical tissue was 35 MPa in the implant that neighbors the cantilever in group ILIC. The maximum von Mises stress in the trabecular bone was 3.5 MPa.Conclusion. The prosthetic configuration of group IC limited the displacement of the prosthetic structure but led to greater displacement of the bone structure. The use of a cantilever increased the stress concentration in the implant and in the bone structure adjacent to the cantilever under the conditions studied here.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The organic charge-transfer salt EtMe3P[Pd(dmit)(2)](2) is a quasi-two-dimensional Mott insulator with localized spins S = 1/2 residing on a distorted triangular lattice. Here we report measurements of the uniaxial thermal expansion coefficients alpha(i) along the in-plane i = a and c axis as well as along the out-of-plane b axis for temperatures 1.4 K <= T <= 200 K. Particular attention is paid to the lattice effects around the phase transition at T-VBS = 25 K into a low-temperature valence-bond-solid phase and the paramagnetic regime above where effects of short-range antiferromagnetic correlations can be expected. The salient results of our study include (i) the observation of strongly anisotropic lattice distortions accompanying the formation of the valence-bond-solid phase, and (ii) a distinct anomaly in the thermal expansion coefficients in the paramagnetic regime around 40 K. Our results demonstrate that upon cooling through T-VBS the in-plane c axis, along which the valence bonds form, contracts while the second in-plane a axis elongates by the same relative amount. Surprisingly, the dominant effect is observed for the out-of-plane b axis which shrinks significantly upon cooling through T-VBS. The pronounced anomaly in alpha(i) around 40 K is attributed to short-range magnetic correlations. It is argued that the position of this maximum, relative to that in the magnetic susceptibility around 70 K, speaks in favor of a more anisotropic triangular-lattice scenario for this compound than previously thought.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare with pristine sites bone resorption and soft tissue adaptation at implants placed immediately into extraction sockets (IPIES) in conjunction with deproteinized bovine bone mineral (DBBM) particles and a collagen membrane.Material and methods: The mesial root of the third premolar in the left side of the mandible was endodontically treated (Test). Flaps were elevated, the tooth hemi-sectioned, and the distal root removed to allow the immediate installation of an implant into the extraction socket in a lingual position. DBBM particles were placed into the defect and on the outer contour of the buccal bony ridge, concomitantly with the placement of a collagen membrane. A non-submerged healing was allowed. The premolar on the right side of the mandible was left in situ (control). Ground sections from the center of the implant as well as from the center of the distal root of the third premolar of the opposite side of the mandible were obtained. The histological image from the implant site was superimposed to that of the contralateral pristine distal alveolus, and dimensional variation evaluated for the hard tissue and the alveolar ridge.Results: After 3 months of healing, both histological and photographic evaluation revealed a reduction of hard and soft tissue dimensions.Conclusion: The contour augmentation performed with DBBM particles and a collagen membrane at the buccal aspects of implants placed IPIES was not able to maintain the tissue volume.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is very known that due to inflammatory processes the obesity leads to resistance to leptin, it reduces phosphorylation via JAK-2/STAT-3, which generates lower STAT-3 activity in the cell nucleus, and it leads to decrease the number of transcription of anorexigenic neurons (POMC/CART) and allowing transcription of orexigenic (NPY/AgRP). PURPOSE: The present study aimed to evaluate the effects of moderate aerobic training on food intake of obese mice through analysis of activity of hypothalamic proteins JAK-2/STAT-3. METHODS: It were used 30 Swiss mice (30 days old) divided into 3 groups: Control Group (C): sedentary animals fed with balanced diet ; Obese (OB) sedentary animals fed with high-fat diet throughout the experiment and Trained Obese (TOB) : animals fed with high fat diet throughout the experiment , kept sedentary during the first half of the experiment (8 weeks) and submitted to physical training protocol during the second half of the experiment (8 weeks). The exercise program consisted of treadmill running 1h, 5 days/week during 8 weeks at a speed equivalent to 60 % of maximum potency determined at the beginning of training period. To assess the leptin resistance, after rats were deprived of food for 6h with free access to water, they received i.p injection with leptin (2.0µl, 10-6M), after this, the chow was returned and food intake was determined by measuring the quantity and Kcal consumed at the end of 2h. The hypothalami was removed for determination of JAK-2 and STAt-3 activity. RESULTS: Our results showed that moderate physical exercise was effective in improving the JAK/STAT signaling pathway in the hypothalamus of obese animals. This has made these obese animals had reduced food intake and consequently lower body mass gain. CONCLUSION: It can be concluded that physical exercise, for restoring leptin signaling in the hypothalamus, controls the synthesis of neurons responsible for appetite and thus is an important tool in the treatment of obesity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The endopeptidase 22.19 (EC 3.4.22.19) has been associated with the metabolism of neuropeptides by its ability to convert small enkephalin-containing peptides (8 to 13 amino acids) into enkephalins. In addition, this enzyme cleaves the Arg8-Arg9 bond of neurotensin and the Phe5-Ser6 bond of bradykinin. We analyzed the circadian variation of endopeptidase 22.19 in the whole and individual areas of the rat brain. Endopeptidase 22.19 activity was analyzed by high-performance liquid chromatography (HPLC) using bradykinin as an operative substrate. Enzymatic specific activities were analyzed by rhythmometric methods and indicate a circadian fluctuation of endopeptidase 22.19 specific activity (mU of enzyme/mg of protein) in the whole brain [p < 0.001, mesor (M) = 7.62, amplitude (A) = 2.89, and acrophase (phi) = 23:08 h], striatum (p < 0.001, M = 2.92, A = 0.62, phi-23:03 h), hypothalamus (p < 0.001, M = 3.15, A = 0.86, phi-01:12 h), periaqueductal gray matter (p < 0.005, M = 2.62, A = 0.34, phi = 22:35 h), and cerebellum (p < 0.0 14, M = 4.27, A = 0.88, phi = 17:12 h). The circadian rhythmicity in endopeptidase 22.19 specific activity suggests that light may have an effect on the peptidase activity in whole brain and in areas of the central nervous system and may be essential for the mechanisms of circadian fluctuations of neuropeptides in the brain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we introduce a type of Hypercomplex Fourier Series based on Quaternions, and discuss on a Hypercomplex version of the Square of the Error Theorem. Since their discovery by Hamilton (Sinegre [1]), quaternions have provided beautifully insights either on the structure of different areas of Mathematics or in the connections of Mathematics with other fields. For instance: I) Pauli spin matrices used in Physics can be easily explained through quaternions analysis (Lan [2]); II) Fundamental theorem of Algebra (Eilenberg [3]), which asserts that the polynomial analysis in quaternions maps into itself the four dimensional sphere of all real quaternions, with the point infinity added, and the degree of this map is n. Motivated on earlier works by two of us on Power Series (Pendeza et al. [4]), and in a recent paper on Liouville’s Theorem (Borges and Mar˜o [5]), we obtain an Hypercomplex version of the Fourier Series, which hopefully can be used for the treatment of hypergeometric partial differential equations such as the dumped harmonic oscillation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel nanostructured composite, azide copper octa (3-aminopropyl)octasilsesquioxane (ASCA) was incorporated into a graphite paste electrode and the electrochemical studies were conducted with cyclic voltammetry. The cyclic voltammogram of the modified graphite paste electrode with ASCA (GPE-ASCA), showed one redox couple with formal potential (E  ) = 0.30 V and an irreversible process at 1.1 V (vs Ag/AgCl; NaCl 1.0 mol L-1 ; v = 20 mV s-1 ). The redox couple with (E  ) = 0.30V presents an electrocatalytic response for determination of ascorbic acid. The modified electrode gives a linear range from 1.010-4 – 1.010-3 mol L-1 (r = 0.998) for the determination of ascorbic acid with detection limit of 6.910-5 mol L-1 and standard deviation of 2.3% for n = 3 . The amperometric sensitivity was 122.1 mA/mol L-1 for ascorbic acid. The application this electrode was tested and ascorbic acid in three commercial pharmaceutical product (Cebion, Cewin and Redoxon) have been determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces. Methods: A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N.mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed. Results: When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 mu m strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 mu m strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws. Conclusions: We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.