920 resultados para Subtalar joint
Resumo:
This paper deals with the joint economic design of (x) over bar and R charts when the occurrence times of assignable causes follow Weibull distributions with increasing failure rates. The variable quality characteristic is assumed to be normally distributed and the process is subject to two independent assignable causes (such as tool wear-out, overheating, or vibration). One cause changes the process mean and the other changes the process variance. However, the occurrence of one kind of assignable cause does not preclude the occurrence of the other. A cost model is developed and a non-uniform sampling interval scheme is adopted. A two-step search procedure is employed to determine the optimum design parameters. Finally, a sensitivity analysis of the model is conducted, and the cost savings associated with the use of non-uniform sampling intervals instead of constant sampling intervals are evaluated.
Resumo:
A lot sizing and scheduling problem from a foundry is considered in which key materials are produced and then transformed into many products on a single machine. A mixed integer programming (MIP) model is developed, taking into account sequence-dependent setup costs and times, and then adapted for rolling horizon use. A relax-and-fix (RF) solution heuristic is proposed and computationally tested against a high-performance MIP solver. Three variants of local search are also developed to improve the RF method and tested. Finally the solutions are compared with those currently practiced at the foundry.
Resumo:
1. The present study compared the duration of the electromyographic silent period (SP) of the masseter muscles elicited by chin-tapping in normal asymptomatic adults (N = 39) and in a group with symptoms of temporomandibular joint dysfunction (TMJD) (N = 31).2. EMG activity was recorded from right (RM) and left (LM) masseter muscles using bipolar surface electrodes coupled to a DISA 1500 EMG-System. During maximal clenching, ten taps were applied downwards to the chin with a reflex hammer.3. The mean SP durations obtained for the normal group were 25.45 +/- 4.20 ms (RM) and 25.33 +/- 4.18 ms (LM), whereas the TMJD group presented significantly greater values (P < 0.01, Student t-test) of 41.89 +/- 12.94 ms (RM) and 42.40 +/- 12.99 ms (LM). The upper limits of normality calculated for RM and LM were 32.36 ms and 31.21 ms, respectively. Eighty-four percent of patients with TMJD showed SP durations above these limits.4. The results indicate that the measurement of masseteric SP duration may be used as an objective diagnostic method of TMJ disorders, provided that borderline values are interpreted with caution along with clinical impressions.
Resumo:
When joint (X) over bar and R charts are in use, samples of fixed size are regularly taken from the process, and their means and ranges are plotted on the (X) over bar and R charts, respectively. In this article, joint (X) over bar and R charts have been used for monitoring continuous production processes. The sampling is performed, in two stages. During the first stage, one item of the sample is inspected and, depending on the result, the sampling is interrupted if the process is found to be in control; otherwise, it goes on to the second stage, where the remaining sample items are inspected. The two-stage sampling procedure speeds up the detection of process disturbances. The proposed joint (X) over bar and R charts are easier to administer and are more efficient than the joint (X) over bar and R charts with variable sample size where the quality characteristic of interest can be evaluated either by attribute or variable. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Strong photoluminescent emission has been measured at room temperature for noncrystalline BaT'O-3 (BT) perovskite powders. A joint experimental and theoretical study has been carried out to rationalize this phenomenon. From the experimental side, BT powder samples have been synthesized following a soft chemical processing, their crystal structure has been confirmed by x-ray data and the corresponding photoluminescence (PL) properties have been measured. Only the structurally disordered samples present PL at room temperature. From the theoretical side, first-principles quantum-mechanical techniques, based on density-functional theory at the B3LYP level, have been employed to study the electronic structure of crystalline (BT-c) and asymmetric (BT-a) models. Theoretical and experimental results are found to be consistent and their confrontation leads to an interpretation of the PL apparition at room temperature in the structurally disordered powders.
Resumo:
A joint experimental and theoretical study has been carried out to rationalize for the first time the photoluminescence (PL) properties of disordered CaWO4 (CWO) thin films. From the experimental side, thin films of CWO have been synthesized following a soft chemical processing, their structure has been confirmed by X-ray diffraction data and corresponding PL properties have been measured using the 488 nm line of an argon ion laser. Although we observe PL at room temperature for the crystalline thin films, the structurally disordered samples present much more intense emission. From the theoretical side, first principles quantum mechanical calculations, based on density functional theory at B3LYP level, have been employed to study the electronic structure of a crystalline (CWO-c) and asymmetric (CWO-a) periodic model. Electronic properties are analyzed in the light of the experimental results and their relevance in relation to the PL behavior of CWO is discussed. The symmetry breaking process on going from CWO-c to CWO-a creates localized electronic levels above the valence band and a negative charge transfer process takes place from threefold, WO3, to fourfold, WO4,. tungsten coordinations. The correlation of both effects seems to be responsible for the PL of amorphous CWO. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The joint sound is a common sign in TMD, the diagnosis is important to establish the treatment of pathological alterations which occur in the TMJ. In this study, two groups were selected: 1, Asymptomatic volunteers; and 2, Symptomatic patients who were diagnosed in a clinical examination. After the initial examination, they were submitted to evaluation using electrovibratography (SonoPAK II, BioResearch Assoc., Inc., Milwaukee, Wisconsin). The analysis of results indicated that the averages of the vibratory energy in the symptomatic group presented higher values in all stages of the mandibular movement when compared to the averages of vibratory energy registered in the asymptomatic group.
Resumo:
The articular disc of the temporomandibular joint was studied in a foetuses and children group (GI), a dentate group of adults (GII) and an edentulous, elderly group of humans (GIII) by light microscopy. The main, constituent bundles of type I collagen fibres are stratified and are orientated sagittally, transversely and obliquely in the middle portion of the disc. In the thick, posterior portion, transverse bundles constitute the main feature. In the anterior portion of the disc, the fibres are sagittally and obliquely orientated. Type III. collagen fibres, intermingled with type I collagen fibres are present in all groups. The disc is cellular in nature in foetuses and children becoming more fibrous with age. Chondroid cells are observed in all portions of the discs in groups GII and GIII. Elastic fibres are numerous in GI discs and decrease in number in the disc with age. These fibres lie parallel to the collagen fibres in all three portions of the three groups.
Resumo:
Background. The authors compared the efficacy of bilateral balanced and canine guidance (occlusal) splints in the treatment of temporomandibular joint (TMJ) pain in subjects who experienced joint clicking with a nonoccluding splint in a double-blind, controlled randomized clinical trial.Methods. The authors randomly assigned 57 people with signs of disk displacement and TMJ pain into three groups according to the type of splint: bilateral balanced, canine guidance and nonoccluding. The authors followed the groups for six months using analysis of a visual analog scale (VAS), palpation of the TMJ and masticatory muscles, mandibular movements and joint sounds. They used repeated analysis of variance and a XI test to test the hypothesis.Results. The type of guidance used did not influence the pain reduction; yet both occlusal splints were superior to the nonoccluding splint, on the basis of the VAS. Despite similar outcomes in relation to opening, left; lateral and protrusive movements, TMJ and muscle pain on palpation, subjects who used the occlusal splints had improved clinical outcomes. The frequency of joint noises decreased over time, with no significant differences among groups. Subjects in the groups using the occlusal splints reported more comfort.Conclusion. The type of lateral guidance did not influence the subjects'; improvement: All of the subjects had a general improvement on the VAS, though subjects in the occlusal splint groups had better results that did subjects in the nonoccluding splint group.