881 resultados para Silicon oil, interface forces, surface potential, AFM forces, PDMS interface forces.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Diverse amorphous hydrogenated carbon-based films (a-C:H, a-C:H:F, a-C:H:N, a-C:H:Cl and a-C:H:Si:O) were obtained by radiofrequency plasma enhanced chemical vapor deposition (PECVD) and plasma immersion ion implantation and deposition (PIIID). The same precursors were used in the production of each pair of each type of film, such as a-C:H, using both PECVD and PIIID. Optical properties, namely the refractive index, n, absorption coefficient, α, and optical gap, ETauc, of these films were obtained via transmission spectra in the ultraviolet-visible near-infrared range (wavelengths from 300 to 3300 nm). Film hardness, elastic modulus and stiffness were obtained as a function of depth using nano-indentation. Surface energy values were calculated from liquid drop contact angle data. Film roughness and morphology were assessed using atomic force microscopy (AFM). The PIIID films were usually thinner and possessed higher refractive indices than the PECVD films. Determined refractive indices are consistent with literature values for similar types of films. Values of ETauc were increased in the PIIID films compared to the PECVD films. An exception was the a-C:H:Si:O films, for which that obtained by PIIID was thicker and exhibited a decreased ETauc. The mechanical properties - hardness, elastic modulus and stiffness - of films produced by PECVD and PIIID generally present small differences. An interesting effect is the increase in the hardness of a-C:H:Cl films from 1.0 to 3.0 GPa when ion implantation is employed. Surface energy correlates well with surface roughness. The implanted films are usually smoother than those obtained by PECVD. ©2013 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In a typical protocol for attaching DNA to a gold electrode, thiolated DNA is incubated with the electrode at neutral pH overnight. Here we report fast adsorption of non-thiolated DNA oligomers on gold electrodes at acidic pH (i.e., pH ~3.0). The peak-to-peak potential difference and the redox peak currents in typical cyclic voltammetry of [Fe(CN)6]3- are investigated to monitor the attachment. Compared with incubation at neutral pH, the lower pH can significantly promote the adsorption processes, enabling efficient adsorption even in 30min. The adsorption rate is DNA concentration-dependent, while the ionic strength shows no influence. Moreover, the adsorption is base-discriminative, with a preferred order of A>C≫G, T, which is attributed to the protonation of A and C at low pH and their higher binding affinity to gold surface. The immobilized DNA is functional and can hybridize with its complementary DNA but not a random DNA. This work is promising to provide a useful time-saving strategy for DNA assembly on gold electrodes, allowing fast fabrication of DNA-based biosensors and devices. © 2013 Elsevier Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O interesse no comportamento dinâmico de estruturas metálicas vem crescendo nas últimas décadas no Brasil, em decorrência de acidentes com colapso total de algumas estruturas devido às vibrações ambientes em diversas regiões do país. Na região amazônica, por exemplo, onde esse tipo de estrutura deve vencer obstáculos como florestas e rios de grande largura, casos de colapso total de estruturas metálicas também são relatados. O foco principal dessa dissertação é o estudo do comportamento modal de estruturas metálicas submetidas às vibrações ambientes cuja magnitude das forças de excitação é desconhecida. Dois estudos de caso são apresentados: no primeiro deles, o comportamento modal de uma torre de linha de transmissão de energia elétrica é investigado; e no segundo caso, tanto o comportamento modal como os níveis de desconforto de uma ponte são estudados. Os estudos realizados neste último caso visam avaliar os níveis de desconforto da ponte quando submetida às excitações ambientes como rajadas de vento e o tráfego de veículo de acordo a norma brasileira NBR 8800 (1986). Em ambos os estudos de caso foram realizadas análises experimentais e computacionais. Na etapa experimental, ambas as estruturas foram monitoradas com emprego de um conjunto de acelerômetros de baixa freqüência e também de um sistema de aquisição apropriados para ensaios de vibração de estruturas civis. Como é muito difícil medir a magnitude das forças de excitação ambientes, foram utilizados os métodos de identificação estocásticos SSI-DATA e SSI-COV para extração de parâmetros modais de estruturas civis a partir somente dos dados de resposta coletados nos ensaios de vibração. Entre as atividades desenvolvidas nessa etapa, destaca-se a criação de um programa computacional com recursos do Graphical User Interface (GUI) da plataforma Matlab®, destinado à identificação modal de estruturas civis com o emprego dos referidos métodos estocásticos. Esse programa é constituído de três módulos: o primeiro é destinado ao processamento e tratamento dos sinais coletados nos ensaios de vibração; o segundo é utilizado para adicionar as informações do posicionamento dos acelerômetros utilizados nos arquivos dos sinais de resposta; e o terceiro e último módulo é destinado à identificação a partir dos arquivos de dados de resposta processados nos dois primeiros módulos. Na etapa das análises teóricas, foram criados modelos numéricos utilizando o método dos elementos finitos para simular o comportamento dinâmico das estruturas analisadas. Comparando os resultados obtidos em ambas as etapas de análise, verifica-se que resultados experimentais e teóricos apresentaram parâmetros bastante próximos entre si nos primeiros modos de vibração. Os resultados experimentais mostraram que ambos os métodos estocásticos foram muito eficientes na identificação das estruturas ensaiadas.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, the transesterification of jupati (Raphia taedigera Mart.) oil using ethanol and acid catalyst was examined. The production of biodiesel was performed using a central composite design (CCD). A range of values for catalyst concentration (1 to 4.21%), temperature (70-80 °C), and the molar ratio of alcohol to oil (6:1-13.83:1) were tested, and ester content, viscosity, and yield were the response variables. The synthesis process was optimised using response surface methodology (RSM), resulting in the following optimal conditions for the production of jupati ethyl esters: a catalyst concentration of 3.85% at 80 °C and an alcohol-to-oil molar ratio of 10:1.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Root resorption is a variable to be considered in induced tooth movement (ITM). It is related to root morphology and alveolar bone crest, and also to the types of forces exerted by mechanotherapy. This histometric study evaluated the predominance of root resorption among roots of different dimensions, following ITM with different types of forces and at different time intervals. The study was conducted on 54 rats divided into three groups, according to the type of force: continuous (CF), continuous interrupted (CIF) and intermittent (IF), at periods of 5, 7 and 9 days. The percentage of resorption between mesiobuccal roots of larger dimension and intermediate roots of smaller dimension was assessed. The evaluations were performed on the AxioVision software, and the non-parametric analysis of variance for repeated measures in independent groups was further applied, consisting of a scheme of two factors, and complemented by the Dunn test at a significance level of 5%. The intermediate roots presented a higher percentage of resorption, which was gradual at the periods evaluated for the three types of forces, but mainly for CF. Comparing the intermediate roots with the mesiobuccal roots, there was a statistically significant difference (p < 0.05) in the CF group at day 7 and day 9, and in the FI group, at day 9. The intragroup analysis evidenced a statistically significant difference (p < 0.05) between the 5th and the 9th day for the intermediate root in the CF group. The intergroup analysis did not reveal any statistically significant difference (p > 0.05) in individually analyzed roots.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution on the pen-implant bone, simulating the influence of Nobel Select implants with straight or angulated abutments on regular and switching platform in the anterior maxilla, by means of 3-dimensional finite element analysis. Four mathematical models of a central incisor supported by external hexagon implant (13 mm x 5 mm) were created varying the platform (R, regular or S. switching) and the abutments (S, straight or A, angulated 15 degrees). The models were created by using Mimics 13 and Solid Works 2010 software programs. The numerical analysis was performed using ANSYS Workbench 10.0. Oblique forces (100 N) were applied to the palatine surface of the central incisor. The bone/implant interface was considered perfectly integrated. Maximum (sigma(max)) and minimum (sigma(min)) principal stress values were obtained. For the cortical bone the highest stress values (sigma(max)) were observed in the RA (regular platform and angulated abutment, 51 MPa), followed by SA (platform switching and angulated abutment, 44.8 MPa), RS (regular platform and straight abutment, 38.6 MPa) and SS (platform switching and straight abutment, 36.5 MPa). For the trabecular bone, the highest stress values (sigma(max)) were observed in the RA (6.55 MPa), followed by RS (5.88 MPa), SA (5.60 MPa), and SS (4.82 MPa). The regular platform generated higher stress in the cervical periimplant region on the cortical and trabecular bone than the platform switching, irrespective of the abutment used (straight or angulated).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of the current review was to investigate the implications of the surface and bulk properties of abutment implants and their degradation in relation to periodontal health. The success of dental implants is no longer a challenge for dentistry. The scientific literature presents several types of implants that are specific for each case. However, in cases of prosthetics components, such as abutments, further research is needed to improve the materials used to avoid bacterial adhesion and enhance contact with epithelial cells. The implanted surfaces of the abutments are composed of chemical elements that may degrade under different temperatures or be damaged by the forces applied onto them. This study showed that the resulting release of such chemical elements could cause inflammation in the periodontal tissue. At the same time, the surface characteristics can be altered, thus favoring biofilm development and further increasing the inflammation. Finally, if not treated, this inflammation can cause the loss of the implant.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)