989 resultados para Service Measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Although acute pain is frequently reported by patients admitted to the emergency room, it is often insufficiently evaluated by physicians and is thus undertreated. With the aim of improving the care of adult patients with acute pain, we developed and implemented abbreviated clinical practice guidelines (CG) for the staff of nurses and physicians in our hospital's emergency room. METHODS: Our algorithm is based upon the practices described in the international literature and uses a simultaneous approach of treating acute pain in a rapid and efficacious manner along with diagnostic and therapeutic procedures. RESULTS: Pain was assessed using either a visual analogue scale (VAS) or a numerical rating scale (NRS) at ER admission and again during the hospital stay. Patients were treated with paracetamol and/or NSAID (VAS/NRS <4) or intravenous morphine (VAS/NRS > or =04). The algorithm also outlines a specific approach for patients with headaches to minimise the risks inherent to a non-specific treatment. In addition, our algorithm addresses the treatment of paroxysmal pain in patients with chronic pain as well as acute pain in drug addicts. It also outlines measures for pain prevention prior to minor diagnostic or therapeutic procedures. CONCLUSIONS: Based on published guidelines, an abbreviated clinical algorithm (AA) was developed and its simple format permitted a widespread implementation. In contrast to international guidelines, our algorithm favours giving nursing staff responsibility for decision making aspects of pain assessment and treatment in emergency room patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although stress has been a longstanding issue in organizations and management studies, it has never been studied in relation to Public Service Motivation. This article therefore aims to integrate PSM into the job demands-job resources model of stress in order to determine whether PSM might contribute to stress in public organizations. Drawing upon original data from a questionnaire in a Swiss municipality, this study unsurprisingly shows that "red tape" is an antecedent of stress perception, whereas satisfaction with organizational support, positive feedback, and recognition significantly decrease the level of perceived stress. Astonishingly, the empirical results show that PSM is positively and significantly related to stress perception. By increasing individuals' expectations towards their jobs, PSM might thus contribute to increased pressure on public agents. Ultimately, this article investigates the "dark side" of PSM, which has been neglected by the literature thus far.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of BMD by dual-energy X-ray absorptiometry (DXA) is the "gold standard" for diagnosing osteoporosis but does not directly reflect deterioration in bone microarchitecture. The trabecular bone score (TBS), a novel gray-level texture measurement that can be extracted from DXA images, correlates with 3D parameters of bone microarchitecture. Our aim was to evaluate the ability of lumbar spine TBS to predict future clinical osteoporotic fractures. A total of 29,407 women 50 years of age or older at the time of baseline hip and spine DXA were identified from a database containing all clinical results for the Province of Manitoba, Canada. Health service records were assessed for the incidence of nontraumatic osteoporotic fracture codes subsequent to BMD testing (mean follow-up 4.7 years). Lumbar spine TBS was derived for each spine DXA examination blinded to clinical parameters and outcomes. Osteoporotic fractures were identified in 1668 (5.7%) women, including 439 (1.5%) spine and 293 (1.0%) hip fractures. Significantly lower spine TBS and BMD were identified in women with major osteoporotic, spine, and hip fractures (all p < 0.0001). Spine TBS and BMD predicted fractures equally well, and the combination was superior to either measurement alone (p < 0.001). Spine TBS predicts osteoporotic fractures and provides information that is independent of spine and hip BMD. Combining the TBS trabecular texture index with BMD incrementally improves fracture prediction in postmenopausal women. © 2011 American Society for Bone and Mineral Research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is  the IPH response to the Department of Health, Social Services & Public Safety's Draft Framework for Mental Health and Wellbeing

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welcome to the easy access version of the Service Framework for Cardiovascular Health and Wellbeing. åÊ It sets out what you can expect from the Health and Social Care (HSC) services in Northern Ireland if you have a cardiovascular illness or you care for someone who does.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Easy Access Version

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Easy Access Version

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Learning Disability Service Framework - Easy Access Version

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Easy Access Version