989 resultados para Schottky Diode


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposal presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results of a 15kW prototype are also presented in this paper. © 2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results are also presented in this paper. © 2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm X 5 mm) and covered with a Mylar strip. The tip of the lightcuring unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37°C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (α=0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the lightcuring unit and by its light energy density. © Operative Dentistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Authors - Magno AFF, Martins RP, Vaz LG, Martins LP Objectives - Evaluate the shear bond strength (SBS) and the adhesive remnant index (ARI) of indirect bonded lingual brackets using xenon plasma arc light, light-emitting diode (LED) and conventional quartz-tungsten-halogen light. Material and Methods - Lingual brackets were bonded indirectly to 60 premolars divided to three groups according to the curing light used: Group 1, plasma arc for 6 s; Group 2, LED for 10 s; and Group 3, halogen light for 40 s. After bonding, the specimens were subjected to a shear force until debonding. The debonding pattern was assessed and classified according to the ARI scores. The mean shear bond strengths were accessed by anova followed by the Student-Newman-Keuls test for multiple comparisons. ARI scores were assessed using the chi-square test. Results - The three groups showed significant differences (p < 0.001), with the averages of group 1 < group 2 < group 3. Groups showed no differences regarding ARI scores. Conclusion - Bonding lingual brackets indirectly with plasma arc, during 60% of the time used for the LED, produced lower SBS than obtained with the latter. Using LED during 25% of the time of the halogen light produced lower SBS than obtained with the latter. These differences did not influence the debonding pattern and are clinically acceptable according to the literature. © 2010 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: This study evaluated the temperature rise of the adhesive system Single Bond (SB) and the composite resins Filtek Z350 flow (Z) and Filtek Supreme (S), when polymerized by light-emitting diode (LED XL 3000) and quartz-tungsten halogen (QTH Biolux). METHODS: Class V cavities (3 yen2 mm) were prepared in 80 bovine incisors under standardized conditions. The patients were divided as follows: G1: Control; G2: SB; G3: SB + Z; G4: SB + S. The groups were subdivided into two groups for polymerization (A: QTH, B: LED). Light curing was performed for 40 s and measurement of temperature changes during polymerization was performed with a thermocouple positioned inside the pulp chamber. Data were statistically analyzed using ANOVA and Tukey tests. RESULTS: The factors material (P<0.00001) and curing unit (P<0.00001) had significant influence on temperature rise. The lowest temperature increase (0.15 degrees C) was recorded in G2 B and the highest was induced in G1 A (0.75 degrees C, P<0.05). In all groups, lower pulp chamber temperature measurements were obtained when using LED compared to QTH (P<0.05). CONCLUSION: QTH caused greater increases in tooth temperature than LED. However, both sources did not increase pulpal temperature above the critical value that may cause pulpal damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study measured the critical temperature reaching time and also the variation of temperature in the surface of the cervical region and within the pulp chamber of human teeth submitted to dental bleaching using 35% hydrogen peroxide gel activated by three different light sources. The samples were randomly divided into 3 groups (n = 15), according to the catalyst light source: Halogen Light (HL), High Intensity Diode Laser (DL), and Light Emmited Diode (LED). The results of temperature variation were submitted to the analysis of variance and Tukey test with p < 0.05. The temperature increase (mean value and standard deviation) inside the pulp chamber for the HL group was 6.8 ± 2.8°C; for the DL group was 15.3 ± 8.8°C; and for the LED group was 1.9 ± 1.0°C for. The temperature variation (mean value and standard deviation) on the tooth surface, for the group irradiated with HL was 9.1 ± 2.2°C; for the group irradiated with DL were 25.7 ± 18.9°C; and for the group irradiated with LED were 2.6 ± 1.4°C. The mean temperature increase values were significantly higher for the group irradiated with DL when compared with groups irradiated with HL and LED (p < 0.05). When applying the inferior limits of the interval of confidence of 95%, an application time of 38.7 s was found for HL group, and 4.4 s for DL group. The LED group did not achieve the critical temperatures for pulp or the periodontal, even when irradiated for 360 s. The HL and DL light sources may be used for dental bleaching for a short period of time. The LED source did not heat the target tissues significantly within the parameters used in this study. © 2010 Pleiades Publishing, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of low-level laser (LLL) may be an useful tool to promote reduction of muscular pain caused by TMD. Aim: This study evaluated the immediate efficacy of low-level laser therapy on women reporting pain and diagnosed with temporomandibular dysfunction (TMD). Methods: Diode laser (GaAlAs) at 790 nm wavelength (infrared spectrum) was applied as experimental treatment. Irradiations of 1.5 J/cm2 were made at 4 points of the temporomandibular joint (TMJ) and of 3 J/cm2 at 3 points in the temporal muscle. An electromyographic (EMG) evaluation of the masseter and anterior temporal was done at the following intervals: before, immediately after, 5 min and 20 min after laser application. Results: Comparison of the electrical activity at the times of measurement revealed a statistically significant difference in masseter muscles before (P=0.025) and immediately after (P=0.013) LLLT. Conclusions: Both masseter and temporal muscles showed a reduction in the measured EMG activities at all times after LLLT, and the temporal muscle showed higher EMG activity than the masseter muscle at all the evaluation times. LLLT caused significant immediate relaxation of the masseter muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports on the changes of performance of solid-state cells dye-sensitized solar cells with the variation of concentration of spiro-OMeTAD between 5% and 25% in the fabrication of the cell. Variations of charge recombination and capacitance correlate with the improvement of current-potential characteristics at increasing spiro-OMeTAD content, which is explained by reduction of transport resistance for hole transport, the increase of charge separation in the dye molecules, and importantly, with the increase of the β-factor in the recombination resistance, that causes a reduction of the diode ideality factor. © 2010 Materials Research Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This prospective randomized trial evaluated if there is an improvement in clinical outcomes when assisted hatching is performed in embryos derived from vitrified oocytes in an ovum donation program. Methods: Sixty oocyte recipients undergoing donation program using egg-cryobanking were randomly allocated to the assisted hatched (AH, n=30) or control group (n=30). Pregnancy and implantation rates were compared between the groups. Vitrification and warming procedure were carried out according to the Cryotopmethod. Immediately before embryo transfer, embryos undergoing laser-assisted hatching had the zona pellucida thinned using a 1.48 μm wavelength diode laser. Results: A total of 288 vitrified MII oocytes were warmed for the 60 recipients (4.8 oocytes per recipient). Out of 288 vitrified oocytes, 273 (94.8%) survived. All surviving oocytes were sperm injected and 228 displayed 2 pronucleus 16-18h after injection (83.5%). There were 172 good quality embryos transferred. Twenty four patients achieved clinical pregnancy (total pregnancy rate of 40%). The clinical pregnancy rate did not differ between AH and control groups (44.4% and 33.3%, respectively, p=0.1967), however AH resulted in a significant higher implantation rate (31.6% and 18.4%, p=0.0206). These findings were confirmed by the regression models either for pregnancy (OR = 1.14; IC 95% = 0.80-.72; p= 0.766), as for the implantation rate (RC:19.45, P=0.041). Conclusions: Our evidences demonstrated the effectiveness of the AH in embryos derived from warmed oocytes and suggest that oocyte cryopreservation is a valuable tool to provide successful outcomes in an egg donor program. © Todos os direitos reservados a SBRA - Sociedade Brasileira de Reprodução Assistida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of specific parameters of low-level laser therapy (LLLT) on biofilms formed by Streptococcus mutans, Candida albicans or an association of both species. Single and dual-species biofilms - SSB and DSB - were exposed to laser doses of 5, 10 or 20 J/cm 2 from a near infrared InGaAsP diode laser prototype (LASERTable; 780 ± 3 nm, 0.04 W). After irradiation, the analysis of biobilm viability (MTT assay), biofilm growth (cfu/mL) and cell morphology (SEM) showed that LLLT reduced cell viability as well as the growth of biofilms. The response of S. mutans (SSB) to irradiation was similar for all laser doses and the biofilm growth was dose dependent. However, when associated with C. albicans (DSB), S. mutans was resistant to LLLT. For C. albicans, the association with S. mutans (DSB) caused a significant decrease in biofilm growth in a dose-dependent fashion. The morphology of the microorganisms in the SSB was not altered by LLLT, while the association of microbial species (DSB) promoted a reduction in the formation of C. albicans hyphae. LLLT had an inhibitory effect on the microorganisms, and this capacity can be altered according to the interactions between different microbial species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recovery of phenolic compounds of Eugenia pyriformis using different solvents was investigated in this study. The compounds were identified and quantified by reverse-phase high-performance liquid chromatography coupled with ultraviolet-visible diode-array detector (RP-HPLC-DAD/UV-vis). Absolute methanol was the most effective extraction agent of phenolic acids and flavonols (588.31 mg/Kg) from Eugenia pyriformis, although similar results (p ≤ 0.05) were observed using methanol/water (1:1 ratio). Our results clearly showed that higher contents of phenolic compounds were not obtained either with the most or the least polar solvents used. Several phenolic compounds were identified in the samples whereas gallic acid and quercetin were the major compounds recovered. © 2012 Association of Food Scientists & Technologists (India).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine adequate energy doses using specific parameters of LLLT to produce biostimulatory effects on human gingival fibroblast culture. Cells (3 10 4 cells/cm 2) were seeded on 24-well acrylic plates using plain DMEM supplemented with 10 fetal bovine serum. After 48-hour incubation with 5 CO2 at 37C, cells were irradiated with a InGaAsP diode laser prototype (LASERTable; 780 3 nm; 40mW) with energy doses of 0.5, 1.5, 3, 5, and 7J/cm 2. Cells were irradiated every 24h totalizing 3 applications. Twenty-four hours after the last irradiation, cell metabolism was evaluated by the MTT assay and the two most effective doses (0.5 and 3J/cm 2) were selected to evaluate the cell number (trypan blue assay) and the cell migration capacity (wound healing assay; transwell migration assay). Data were analyzed by the Kruskal-Wallis and Mann-Whitney nonparametric tests with statistical significance of 5. Irradiation of the fibroblasts with 0.5 and 3J/cm 2 resulted in significant increase in cell metabolism compared with the nonrradiated group (P 0.05). Both energy doses promoted significant increase in the cell number as well as in cell migration (P 0.05). These results demonstrate that, under the tested conditions, LLLT promoted biostimulation of fibroblasts in vitro. Copyright © 2012 Fernanda G. Basso et al.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lead zirconate titanate Pb(Zr 0.50Ti 0.50)O 3 (PZT) thin films were deposited by a polymeric chemical method on Pt(111)/Ti/SiO2/Si substrates to understand the mechanisms of phase transformations and the effect of film thickness on the structure, dielectric and piezoelectric properties in these films. PZT films pyrolyzed at temperatures higher than 350 °C present a coexistence of pyrochlore and perovskite phases, while only perovskite phase grows in films pyrolyzed at temperatures lower than 300 °C. For pyrochlore-free PZT thin films, a small (100) orientation tendency near the film-substrate interface was observed. Finally, we demonstrate the existence of a self-polarization effect in the studied PZT thin films. Results suggest that Schottky barriers and/or mechanical coupling near the filmsubstrate interface are not primarily responsible for the observed self-polarization effect in our films. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multipulse rectifiers can replace a conventional six pulse three-phase rectifier (diode bridge) providing a DC voltage with low ripple, low Total Harmonic Distortion of current (THDi) and a high Power Factor (PF). In this context is presented a multipulse rectifier with generalized Delta-differential autotransformer topology, which can provide any level of DC output voltage for any level of three-phase AC input voltage. This paper presents all the possible configurations for Delta topology in order to choose, through graphics, one configuration that presents reduced weight and volume. The average voltage on the DC bus must be compatible with the DC voltage in the six pulse rectifier used in commercial ASDs. Therefore, it is possible to apply the retrofit technique to replace the conventional bridge rectifier by the proposed multipulse rectifier. Based on mathematic models and simulation results, an 18-pulse rectifier with Delta topology, 220 V of line voltage, 315 V of DC output, and rating 2.5 kW of power was designed, implemented and applied for three different commercial ASDs. Experimental results as voltage and current waveforms and results about PF and THDi will be presented. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present a new approach for thermal lens analysis using a two-wavelength DSPI (Digital Speckle Pattern Interferometry) setup for wavefront sensing. The employed geometry enables the sensor to detect wavefronts with small phase differences and inherent aberrations found in induced lenses. The wavefronts was reconstructed by four-stepping fringe evaluation and branch-cut unwrapping from fringes formed onto a diffusive glass. Real-time single-exposure contour interferograms could be obtained in order to get discernible and low-spacial frequency contour fringes and obtain low-noise measurements. In our experiments we studied the thermal lens effect in a 4% Er-doped CaO-Al2O3 glass sample. The diode lasers were tuned to have a contour interval of around 120 μm. The incident pump power was longitudinally and collinearly oriented with the probe beams. Each interferogram described a spherical-like wavefront. Using the ABCD matrix formalism we obtained the induced lens dioptric power from the thermal effect for different values of absorbed pump power. © 2012 Copyright SPIE.