908 resultados para SMALL-ANGLE X-RAY SCATTERING
Resumo:
Lean meat percentage (LMP) is an important carcass quality parameter. The aim of this work is to obtain a calibration equation for the Computed Tomography (CT) scans with the Partial Least Square Regression (PLS) technique in order to predict the LMP of the carcass and the different cuts and to study and compare two different methodologies of the selection of the variables (Variable Importance for Projection — VIP- and Stepwise) to be included in the prediction equation. The error of prediction with cross-validation (RMSEPCV) of the LMP obtained with PLS and selection based on VIP value was 0.82% and for stepwise selection it was 0.83%. The prediction of the LMP scanning only the ham had a RMSEPCV of 0.97% and if the ham and the loin were scanned the RMSEPCV was 0.90%. Results indicate that for CT data both VIP and stepwise selection are good methods. Moreover the scanning of only the ham allowed us to obtain a good prediction of the LMP of the whole carcass.
Resumo:
BACKGROUND: To test the hypothesis that intervals with superior beat-to-beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance. METHODS: Coronary repositioning precision in consecutive heartbeats was measured on x-ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T2 -prep now follows (T2 -post) rather than precedes the imaging part of the sequence. The performance of T2 -post was quantitatively compared (signal-to-noise [SNR], contrast-to-noise [CNR], vessel sharpness) to that of T2 -prep in vivo. RESULTS: Coronary repositioning precision is <1 mm at peak systole and in mid diastole. When comparing systolic T2 -post to diastolic T2 -prep, CNR and vessel sharpness remained unchanged (both P = NS) but SNR for muscle and blood increased by 104% and 36% (both P < 0.05), respectively. CONCLUSION: Windows with improved coronary repositioning precision exist in the cardiac cycle: one in peak systole and one in mid diastole. Peak-systolic imaging necessitates a re-design of conventional coronary MRA pulse sequences and leads to image quality very similar to that of conventional mid-diastolic data acquisition but improved SNR. J. Magn. Reson. Imaging 2015;41:1251-1258. © 2014 Wiley Periodicals, Inc.
Resumo:
Summary : Aim: To assess the number of immigrants with pulmonary tuberculosis detected by chest x-ray screening at the Swiss border. Method: All adult immigrants entering Switzerland in 2004 were screened by chest x-ray (CXR). The number of radiological abnormalities suggestive of pulmonary tuberculosis, and the proportion requiring treatment for tuberculosis, were assessed retrospectively. The frequency of symptoms among immigrants with documented TB was compared with a sample of immigrants with a normal CXR. Results: Among 8995 immigrants, 8240 had a normal CXR, 630 had some abnormality not suggestive of active TB and 125 (1.4%) had a CXR suggestive of pulmonary TB. A final diagnosis of tuberculosis requiring treatment was made in SO (1 l with positive smear and culture, 16 with positive culture and 23 with negative culture), 57 had fibrotic lesions and 18 had another disease or a normal x-ray on control. The prevalence of symptoms did not differ between 27 immigrants with documented TB (smear+/culture+: 82%, smear-/ culture+: 75%), and 23 with smear-/culturetuberculosis (91%), but lower in 57 immigrants with fibrotic lesions (60%). Cough was more frequent among the 27 immigrants with documented TB (70%) than among 198 smokers without TB (37%) and among 229 non-smokers without TB (15%) Conclusions: Only 22% (27/125) of immigrants with CXR abnormalities suggestive of pulrnonary tuberculosis were documented by smear and/or culture and 40% (50/125) needed antituberculous treatment. 2/11 smear-positive immigrants would not have been detected by a questionnaire on symptoms. Rapport de synthèse : Le but de l'étude est d'évaluer le rendement du dépistage radiologique de la tuberculose pulmonaire chez les immigrés à l'entrée en Suisse. Méthode: parmi les immigrés adultes entrés en Suisse en 2004, qui ont tous passé un contrôle radiologique, le nombre de porteurs de clichés thoraciques suspects de tuberculose et la proportion de cas chez lesquels un traitement antituberculeux a été prescrit ont été évalués rétrospectivement. La fréquence des symptômes chez les immigrés atteints de tuberculose a été comparée à celle d'un groupe contrôle sans tuberculose. Résultats: parmi 8995 immigrés, 8240 avaient un cliché thoracique normal, 630 étaient porteurs d'une anomalie non suspecte de tuberculose active et 125 (1.4%) montraient des signes radiologiques suspects de tuberculose. Un diagnostic final de tuberculose nécessitant un traitement a été posé dans 50 cas (11 cas à frottis et culture positifs, 16 cas à culture positive, 23 cas à culture négative), 57 présentaient des lésions cicatricielles compatibles avec une ancienne tuberculose et 18 avaient une autre affection pulmonaire ou un cliché normal au contrôle. La prévalence des plaintes n'était pas différente entre les 27 immigrés porteurs d'une tuberculose documentée (frottis+ /culture+: 82%, frottis-/culture+ : 75%) et les 23 immigrés atteints d'une tuberculose non documentée (frottis-/culture-: 91%), mais elle était plus élevée que chez les 57 immigrés porteurs de lésions cicatricielles (59%). La toux était plus fréquente chez les 27 tuberculeux documentés (70%) que chez 198 fumeurs sans tuberculose (37%) et chez 229 non fumeurs sans tuberculose (15%). Conclusions: seuls 22% (27/125) des immigrés dont le cliché thoracique est suspect de tuberculose sont porteurs d'une tuberculose documentée par examen direct ou culture et 40% (50/125) nécessitent un traitement antituberculeux. Deux immigrants sur les 11 cas frottis positifs n'auraient pas été dépistés par un questionnaire.
Resumo:
The age of the patient is of prime importance when assessing the radiological risk to patients due to medical X-ray exposures and the total detriment to the population due to radiodiagnostics. In order to take into account the age-specific radiosensitivity, three age groups are considered: children, adults and the elderly. In this work, the relative number of examinations carried out on paediatric and geriatric patients is established, compared with adult patients, for radiodiagnostics as a whole, for dental and medical radiology, for 8 radiological modalities as well as for 40 types of X-ray examinations. The relative numbers of X-ray examinations are determined based on the corresponding age distributions of patients and that of the general population. Two broad groups of X-ray examinations may be defined. Group A comprises conventional radiography, fluoroscopy and computed tomography; for this group a paediatric patient undergoes half the number of examinations as that of an adult, and a geriatric patient undergoes 2.5 times more. Group B comprises angiography and interventional procedures; for this group a paediatric patient undergoes a one-fourth of the number of examinations carried out on an adult, and a geriatric patient undergoes five times more.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
We performed a pilot study to compare vertebral fracture assessments (VFA) and lateral X-rays in terms of inter- and intraobserver reliability and degree of correlation for the detection of syndesmophytes in ankylosing spondylitis (AS). We recruited 19 patients with AS and recent lumbar or cervical lateral X-rays with at least one syndesmophyte. Each patient underwent dual-energy X-ray absorptiometry with measurement of bone mineral density and dorso-lumbar VFA. Intra- and interreader reliability for VFA and X-rays were measured using 2 independent, blinded observers and Cohen's kappa values. An adapted modified Stoke Ankylosing Spondylitis Spinal Score (amSASSS) was generated with each method, and these 2 values correlated. For X-rays, intraobserver and interobserver agreement were 94.3% (κ = 0.83) and 98.6% (κ = 0.96), respectively; for VFA, corresponding values were 92.8% (κ = 0.79) and 93.8% (κ = 0.82). Overall agreement between the 2 techniques was 88.6% (κ = 0.72). The Pearson correlation coefficient for the 2 methods was 0.95 for the modified Stoke Ankylosing Spondylitis Spinal Score . Per dual-energy X-ray absorptiometry-generated bone mineral density, >50% of patients were osteopenic and 10% osteoporotic. In terms of reproducibility and correlation with X-rays, performing a VFA appears to be a candidate for assessing radiographic damage in AS, thought further research is necessary to justify this indication.
Resumo:
Synchrotron radiation X-ray tomographic microscopy is a nondestructive method providing ultra-high-resolution 3D digital images of rock microstructures. We describe this method and, to demonstrate its wide applicability, we present 3D images of very different rock types: Berea sandstone, Fontainebleau sandstone, dolomite, calcitic dolomite, and three-phase magmatic glasses. For some samples, full and partial saturation scenarios are considered using oil, water, and air. The rock images precisely reveal the 3D rock microstructure, the pore space morphology, and the interfaces between fluids saturating the same pore. We provide the raw image data sets as online supplementary material, along with laboratory data describing the rock properties. By making these data sets available to other research groups, we aim to stimulate work based on digital rock images of high quality and high resolution. We also discuss and suggest possible applications and research directions that can be pursued on the basis of our data.
Resumo:
Proteolytic activity is an important virulence factor for Candida albicans (C. albicans). It is attributed to the family of the secreted aspartic proteinases (Saps) from C. albicans with a minimum of 10 members. Saps show controlled expression and regulation for the individual stages of the infection process. Distinct isoenzymes can be responsible for adherence and tissue damage of local infections, while others cause systemic diseases. Earlier, only the structures of Sap2 and Sap3 were known. In our research, we have now succeeded in solving the X-ray crystal structures of the apoenzyme of Sap1 and Sap5 in complex with pepstatin A at 2.05 and 2.5 A resolution, respectively. With the structure of Sap1, we have completed the set of structures of isoenzyme subgroup Sap1-3. Of subgroup Sap4-6, the structure of the enzyme Sap5 is the first structure that has been described up to now. This facilitates comparison of structural details as well as inhibitor binding modes among the different subgroup members. Structural analysis reveals a highly conserved overall secondary structure of Sap1-3 and Sap5. However, Sap5 clearly differs from Sap1-3 by its electrostatic overall charge as well as through structural conformation of its entrance to the active site cleft. Design of inhibitors specific for Sap5 should concentrate on the S4 and S3 pockets, which significantly differ from Sap1-3 in size and electrostatic charge. Both Sap1 and Sap5 seem to play a major part in superficial Candida infections. Determination of the isoenzymes' structures can contribute to the development of new Sap-specific inhibitors for the treatment of superficial infections with a structure-based drug design program.
Resumo:
The subject of this project is about “Energy Dispersive X-Ray Fluorescence ” (EDXRF).This technique can be used for a tremendous variety of elemental analysis applications.It provides one of the simplest, most accurate and most economic analytical methods for thedetermination of the chemical composition of many types of materials.The purposes of this project are:- To give some basic information about Energy Dispersive X-ray Fluorescence.- To perform qualitative and quantitative analysis of different samples (water-dissolutions,powders, oils,..) in order to define the sensitivity and detection limits of the equipment.- To make a comprehensive and easy-to-use manual of the ‘ARL QUANT’X EnergyDispersive X-Ray Fluorescence’ apparatus
Resumo:
A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.
Resumo:
OBJECTIVE: A new tool to quantify visceral adipose tissue (VAT) over the android region of a total body dual-energy x-ray absorptiometry (DXA) scan has recently been reported. The measurement, CoreScan, is currently available on Lunar iDXA densitometers. The purpose of the study was to determine the precision of the CoreScan VAT measurement, which is critical for understanding the utility of this measure in longitudinal trials. DESIGN AND METHODS: VAT precision was characterized in both an anthropomorphic imaging phantom (measured on 10 Lunar iDXA systems) and a clinical population consisting of obese women (n = 32). RESULTS: The intrascanner precision for the VAT phantom across 9 quantities of VAT mass (0-1,800 g) ranged from 28.4 to 38.0 g. The interscanner precision ranged from 24.7 to 38.4 g. There was no statistical dependence on the quantity of VAT for either the inter- or intrascanner precision result (p = 0.670). Combining inter- and intrascanner precision yielded a total phantom precision estimate of 47.6 g for VAT mass, which corresponds to a 4.8% coefficient of variance (CV) for a 1 kg VAT mass. Our clinical population, who completed replicate total body scans with repositioning between scans, showed a precision of 56.8 g on an average VAT mass of 1110.4 g. This corresponds to a 5.1% CV. Hence, the in vivo precision result was similar to the phantom precision result. CONCLUSIONS: The study suggests that CoreScan has a relatively low precision error in both phantoms and obese women and therefore may be a useful addition to clinical trials where interventions are targeted towards changes in visceral adiposity.
Resumo:
We report millimetre-wave continuum observations of the X-ray binaries Cygnus X-3, SS 433, LSI+61 303, Cygnus X-1 and GRS 1915+105. The observations were carried out with the IRAM 30 m-antenna at 250 GHz (1.25 mm) from 1998 March 14 to March 20. These millimetre measurements are complemented with centimetre observations from the Ryle Telescope, at 15 GHz (2.0 cm) and from the Green Bank Interferometer at 2.25 and 8.3 GHz (13 and 3.6 cm). Both Cygnus X-3 and SS 433 underwent moderate flaring events during our observations, whose main spectral evolution properties are described and interpreted. A significant spectral steepening was observed in both sources during the flare decay, that is likely to be caused by adiabatic expansion, inverse Compton and synchrotron losses. Finally, we also report 250 GHz upper limits for three additional undetected X-ray binary stars: LSI+65 010, LSI+61 235 and X Per.
Resumo:
Developing a novel technique for the efficient, noninvasive clinical evaluation of bone microarchitecture remains both crucial and challenging. The trabecular bone score (TBS) is a new gray-level texture measurement that is applicable to dual-energy X-ray absorptiometry (DXA) images. Significant correlations between TBS and standard 3-dimensional (3D) parameters of bone microarchitecture have been obtained using a numerical simulation approach. The main objective of this study was to empirically evaluate such correlations in anteroposterior spine DXA images. Thirty dried human cadaver vertebrae were evaluated. Micro-computed tomography acquisitions of the bone pieces were obtained at an isotropic resolution of 93μm. Standard parameters of bone microarchitecture were evaluated in a defined region within the vertebral body, excluding cortical bone. The bone pieces were measured on a Prodigy DXA system (GE Medical-Lunar, Madison, WI), using a custom-made positioning device and experimental setup. Significant correlations were detected between TBS and 3D parameters of bone microarchitecture, mostly independent of any correlation between TBS and bone mineral density (BMD). The greatest correlation was between TBS and connectivity density, with TBS explaining roughly 67.2% of the variance. Based on multivariate linear regression modeling, we have established a model to allow for the interpretation of the relationship between TBS and 3D bone microarchitecture parameters. This model indicates that TBS adds greater value and power of differentiation between samples with similar BMDs but different bone microarchitectures. It has been shown that it is possible to estimate bone microarchitecture status derived from DXA imaging using TBS.