960 resultados para Radiation use efficiency


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the feasibility and efficacy of subcutaneous amifostine therapy in patients with head and neck cancer treated with curative accelerated radiotherapy (RT). DESIGN: Retrospective study. SETTING: University of Lausanne, Lausanne, Switzerland. PATIENTS: Thirty-three consecutive patients (male-female ratio, 4.5; median age, 54 years [age range, 39-76 years]). INTERVENTIONS: Between November 2000 and January 2003, the 33 patients were treated with curative definitive (n = 19) or postoperative (n = 14) RT with (n = 26) or without (n = 7) chemotherapy. All patients received conformal RT. Fractionation schedule consisted of concomitant-boost (Friday afternoon session) accelerated RT using 70 Gy (2 Gy per fraction) in 6 weeks in patients treated with definitive RT and 66 Gy (2 Gy per fraction) in 5 weeks and 3 days in the postoperative setting. Parotid glands received at least 50 Gy in all patients. Amifostine was administered to a total dose of 500 mg subcutaneously, 15 to 30 minutes before morning RT sessions. RESULTS: All patients received their planned treatment (including chemotherapy). Ten patients received the full schedule of amifostine (at least 25 injections), 9 received 20 to 24 doses, 4 received 10 to 19 doses, 5 received 5 to 9 doses, and 5 received fewer than 5 doses. Fifteen patients (45%) did not show any intolerance related to amifostine use. Amifostine therapy was discontinued because of nausea in 11 patients (33%) and hypotension in 6 patients (18%), and 1 patient refused treatment. No grade 3, amifostine-related, cutaneous toxic effects were observed. Radiotherapy-induced grade 3 acute toxic effects included mucositis in 14 patients (42%), erythema in 14 patients (42%), and dysphagia in 13 patients (39%). Late toxic effects included grade 2 or more xerostomia in 17 patients (51%) and fibrosis in 3 patients (9%). Grade 2 or more xerostomia was observed in 8 (42%) of 19 patients receiving 20 injections or more vs 9 (64%) of 14 patients receiving fewer than 20 injections (P = .15). CONCLUSIONS: Subcutaneous amifostine administration in combination with accelerated concomitant-boost RT with or without chemotherapy is feasible. The major adverse effect of subcutaneous administration was nausea despite prophylactic antiemetic medication, and hypotension was observed in only 6 patients (18%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study shows the efficiency of passive sampling to reveal industrial and agricultural pollution trends. Two practical applications for nonpolar and polar contaminants are presented. Low-density polyethylene (LDPE) samplers were deployed for one year in the Venoge River (VD) to monitor indicator PCBs (iPCBs, IUPAC nos. 28, 52, 101, 138, 153 and 180). The results showed that the impact of PCB emissions into the river is higher in summer than in other seasons due to the low flow rate of the river during this period. P,olar organic chemical integrative samplers (POCIS) were deployed for 4 months in the Sion-Riddes canal (VS) to investigate herbicides (terbuthylazine, diuron and linuron). Desisopropylatrazine-d5 (DIA-d5) was tested as a performance reference compound (PRC) to estimate aqueous concentration. The results showed an increase of water contamination due to the studied agricultural area. The maximal contamination was observed in April and corresponds to the period of herbicide application on the crops.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It was observed in the city of Salvador, State of Bahia, the highest seroprevalence of human T cell lymphotropic virus type 1 (HTLV-I) infection in Brazil as demonstrated by national wide blood bank surveys. In this paper, we report results of an investigation of drug use and sexual behavior associated with HTLV-I infection among male and female injecting drug users (IDUs) in Salvador. A cross sectional study was conducted in the Historical District of Salvador from 1994-1996 (Projeto Brasil-Salvador) and 216 asymptomatic IDUs were selected using the snowball contact technique. Blood samples were collected for serological assays. Sera were screened for human immunodeficiency virus (HIV-1/2) and HTLV-I/II antibodies by ELISA and confirmed by Western blot. The overall prevalence of HTLV-I/II was 35.2% (76/216). The seroprevalence of HTLV-I, HTLV-II and HIV-1 was for males 22%, 11.3% and 44.1% and for females 46.2%, 10.3% and 74.4% respectively. HTLV-I was identified in 72.4% of HTLV positive IDUs. Variables which were significantly associated with HTLV-I infection among males included needle sharing practices, duration of injecting drug use, HIV-1 seropositivity and syphilis. Among women, duration of injecting drug use and syphilis were strongly associated with HTLV-I infection. Multivariate analysis did not change the direction of these associations. Sexual intercourse might play a more important role in HTLV-I infection among women than in men.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BackgroundThe importance of hybridisation during species diversification has long been debated among evolutionary biologists. It is increasingly recognised that hybridisation events occurred during the evolutionary history of numerous species, especially during the early stages of adaptive radiation. We study the effect of hybridisation on diversification in the clownfishes, a clade of coral reef fish that diversified through an adaptive radiation process. While two species of clownfish are likely to have been described from hybrid specimens, the occurrence and effect of hybridisation on the clade diversification is yet unknown.ResultsWe generate sequences of three mitochondrial genes to complete an existing dataset of nuclear sequences and document cytonuclear discordance at a node, which shows a drastic increase of diversification rate. Then, using a tree-based jack-knife method, we identify clownfish species likely stemming from hybridisation events. Finally, we use molecular cloning and identify the putative parental species of four clownfish specimens that display the morphological characteristics of hybrids.ConclusionsOur results show that consistently with the syngameon hypothesis, hybridisation events are linked with a burst of diversification in the clownfishes. Moreover, several recently diverged clownfish lineages likely originated through hybridisation, which indicates that diversification, catalysed by hybridisation events, may still be happening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The hypothesis of ecological divergence giving rise to premating isolation in the face of gene flow is controversial. However, this may be an important mechanism to explain the rapid multiplication of species during adaptive radiation following the colonization of a new environment when geographical barriers to gene flow are largely absent but underutilized niche space is abundant. Using cichlid fish, we tested the prediction of ecological speciation that the strength of premating isolation among species is predicted by phenotypic rather than genetic distance. We conducted mate choice experiments between three closely related, sympatric species of a recent radiation in Lake Mweru (Zambia/DRC) that differ in habitat use and phenotype, and a distantly related population from Lake Bangweulu that resembles one of the species in Lake Mweru. We found significant assortative mating among all closely related, sympatric species that differed phenotypically, but none between the distantly related allopatric populations of more similar phenotype. Phenotypic distance between species was a good predictor of the strength of premating isolation, suggesting that assortative mating can evolve rapidly in association with ecological divergence during adaptive radiation. Our data also reveals that distantly related allopatric populations that have not diverged phenotypically, may hybridize when coming into secondary contact, e.g. upon river capture because of diversion of drainage systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The flexible derotator is one of the therapeutic resources used to combat primary and secondary abnormalities in walking cerebral palsy children. It was developed to reduce abnormal femoral and tibial torsions and lessen the latter's negative functional impact. Objective To determine the effect of wearing a flexible derotator on anatomic and functional parameters in walking cerebral palsy children. Methods We performed a retrospective study of walking cerebral palsy children by gathering data on bone-related parameters (femoral and tibial torsion) and functional parameters (distance and speed gait, and the energy expenditure index (EEI)). Fifteen walking cerebral palsy children were treated with the flexible derotator for one year and 15 untreated walking cerebral palsy children were included as controls. The two groups were compared in terms of the various parameters' change over time between the initial examination (the last examination prior to the start of the study or prior to use of the flexible derotator) and the final examination (after one year of follow-up). Results Right femoral anteversion and right and left external tibial torsion improved. There was a significant increase in distance and speed gait and a decrease in the EEI in walking cerebral palsy children. Conclusion Our retrospective study revealed a significant improvement in functional parameters in children with cerebral palsy, as a result of wearing the flexible derotator for at least 6 hours a day for a year. Bone parameters only improved slightly. Use of the flexible derotator could improve these children's quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new and original reagent based on the use of highly fluorescent cadmium telluride (CdTe) quantum dots (QDs) in aqueous solution is proposed to detect weak fingermarks in blood on non-porous surfaces. To assess the efficiency of this approach, comparisons were performed with one of the most efficient blood reagents on non-porous surfaces, Acid Yellow 7 (AY7). To this end, four non-porous surfaces were studied, i.e. glass, transparent polypropylene, black polyethylene, and aluminium foil. To evaluate the sensitivity of both reagents, sets of depleted fingermarks were prepared, using the same finger, initially soaked with blood, which was then successively applied on the same surface without recharging it with blood or latent secretions. The successive marks were then cut in halves and the halves treated separately with each reagent. The results showed that QDs were equally efficient to AY7 on glass, polyethylene and polypropylene surfaces, and were superior to AY7 on aluminium. The use of QDs in new, sensitive and highly efficient latent and blood mark detection techniques appears highly promising. Health and safety issues related to the use of cadmium are also discussed. It is suggested that applying QDs in aqueous solution (and not as a dry dusting powder) considerably lowers the toxicity risks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In population surveys of the exposure to medical X-rays both the frequency of examinations and the effective dose per examination are required. The use of the Swiss medical tariffication system (TARMED) for establishing the frequency of X-ray medical examinations was explored. The method was tested for radiography examinations performed in 2008 at the Lausanne University Hospital. The annual numbers of radiographies determined from the "TARMED" database are in good agreement with the figures extracted from the local RIS (Radiology Information System). The "TARMED" is a reliable and fast method for establishing the frequency of radiography examination, if we respect the context in which the "TARMED" code is used. In addition, this billing context provides most valuable information on the average number of radiographs per examination as well as the age and sex distributions. Radiographies represent the major part of X-ray examinations and are performed by about 4,000 practices and hospitals in Switzerland. Therefore this method has the potential to drastically simplify the organisation of nationwide surveys. There are still some difficulties to overcome if the method is to be used to assess the frequency of computed tomography or fluoroscopy examinations; procedures that deliver most of the radiation dose to the population. This is due to the poor specificity of "TARMED" codes concerning these modalities. However, the use of CT and fluoroscopy installations is easier to monitor using conventional survey methods since there are fewer centres. Ways to overcome the "TARMED" limitations for these two modalities are still being explored.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Consumption of nicotine in the form of smokeless tobacco (snus, snuff, chewing tobacco) or nicotine-containing medication (gum, patch) may benefit sport practice. Indeed, use of snus seems to be a growing trend and investigating nicotine consumption amongst professional athletes is of major interest to sport authorities. Thus, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide in urine was developed. Sample preparation was performed by liquid-liquid extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in electrospray positive ionization (ESI) mode with selective reaction monitoring (SRM) data acquisition. The method was validated and calibration curves were linear over the selected concentration ranges of 10-10,000 ng/mL for nicotine, cotinine, trans-3-hydroxycotinine and 10-5000 ng/mL for nicotine-N'-oxide and cotinine-N-oxide, with calculated coefficients of determination (R(2)) greater than 0.95. The total extraction efficiency (%) was concentration dependent and ranged between 70.4 and 100.4%. The lower limit of quantification (LLOQ) for all analytes was 10 ng/mL. Repeatability and intermediate precision were ?9.4 and ?9.9%, respectively. In order to measure the prevalence of nicotine exposure during the 2009 Ice Hockey World Championships, 72 samples were collected and analyzed after the minimum of 3 months storage period and complete removal of identification means as required by the 2009 International Standards for Laboratories (ISL). Nicotine and/or metabolites were detected in every urine sample, while concentration measurements indicated an exposure within the last 3 days for eight specimens out of ten. Concentrations of nicotine, cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide were found to range between 11 and 19,750, 13 and 10,475, 10 and 8217, 11 and 3396, and 13 and 1640 ng/mL, respectively. When proposing conservative concentration limits for nicotine consumption prior and/or during the games (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide and cotinine-N-oxide), about half of the hockey players were qualified as consumers. These findings significantly support the likelihood of extensive smokeless nicotine consumption. However, since such conclusions can only be hypothesized, the potential use of smokeless tobacco as a doping agent in ice hockey requires further investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Glucose control is the cornerstone of Diabetes Mellitus (DM) treatment. Although self-regulation using capillary glycemia (SRCG) still remains the best procedure in clinical practice, continuous glucose monitoring systems (CGM) offer the possibility of continuous and dynamic assessment of interstitial glucose concentration. CGM systems have the potential to improve glycemic control while decreasing the incidence of hypoglycemia but the efficiency, compared with SRCG, is still debated. CGM systems have the greatest potential value in patients with hypoglycemic unawareness and in controlling daily fluctuations in blood glucose. The implementation of continuous monitoring in the standard clinical setting has not yet been established but a new generation of open and close loop subcutaneous insulin infusion devices are emerging making insulin treatment and glycemic control more reliable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Metastases are detected in 20% of patients with solid tumours at diagnosis and a further 30% after diagnosis. Radiation therapy (RT) has proven effective in bone (BM) and brain (BrM) metastases. The objective of this study was to analyze the variability of RT utilization rates in clinical practice and the accessibility to medical technology in our region. PATIENTS AND METHODS We reviewed the clinical records and RT treatment sheets of all patients undergoing RT for BM and/or BrM during 2007 in the 12 public hospitals in an autonomous region of Spain. Data were gathered on hospital type, patient type and RT treatment characteristics. Calculation of the rate of RT use was based on the cancer incidence and the number of RT treatments for BM, BrM and all cancer sites. RESULTS Out of the 9319 patients undergoing RT during 2007 for cancer at any site, 1242 (13.3%; inter-hospital range, 26.3%) received RT for BM (n = 744) or BrM (n = 498). These 1242 patients represented 79% of all RT treatments with palliative intent, and the most frequent primary tumours were in lung, breast, prostate or digestive system. No significant difference between BM and BrM groups were observed in: mean age (62 vs. 59 yrs, respectively); gender (approximately 64% male and 36% female in both); performance status (ECOG 0-1 in 70 vs. 71%); or mean distance from hospital (36 vs. 28.6 km) or time from consultation to RT treatment (13 vs. 14.3 days). RT regimens differed among hospitals and between patient groups: 10 × 300 cGy, 5 × 400 cGy and 1x800cGy were applied in 32, 27 and 25%, respectively, of BM patients, whereas 10 × 300cGy was used in 49% of BrM patients. CONCLUSIONS Palliative RT use in BM and BrM is high and close to the expected rate, unlike the global rate of RT application for all cancers in our setting. Differences in RT schedules among hospitals may reflect variability in clinical practice among the medical teams.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nepal has a long history of medical radiology since1923 but unfortunately, we still do not have any Radiation Protection Infrastructure to control the use of ionizing radiations in the various fields. The objective of this study was an assessment of the radiation protection in medical uses of ionizing radiation. Twenty-eight hospitals with diagnostic radiology facility were chosen for this study according to patient loads, equipment and working staffs. Radiation surveys were also done at five different radiotherapy centers. Questionnaire for radiation workers were used; radiation dose levels were measured and an inventory of availability of radiation equipment made. A corollary objective of the study was to create awareness in among workers on possible radiation health hazard and risk. It was also deemed important to know the level of understanding of the radiation workers in order to initiate steps towards the establishment of Nepalese laws, regulation and code of radiological practice in this field. Altogether, 203 Radiation workers entertained the questionnaire, out of which 41 are from the Radiotherapy and 162 are from diagnostic radiology. The radiation workers who have participated in the questionnaire represent more than 50% of the radiation workers working in this field in Nepal. Almost all X-ray, CT and Mammogram installations were built according to protection criteria and hence found safe. Radiation dose level at the reference points for all the five Radiotherapy centers are within safe limit. Around 65% of the radiation workers have never been monitored for radiation. There is no quality control program in any of the surveyed hospitals except radiotherapy facilities.