997 resultados para Radiation sources.
Resumo:
We deal with a classical predictive mechanical system of two spinless charges where radiation is considered and there are no external fields. The terms (2,2)Paa of the expansion in the charges of the HamiltonJacobi momenta are calculated. Using these, together with known previous results, we can obtain the paa up to the fourth order. Then we have calculated the radiated energy and the 3-momentum in a scattering process as functions of the impact parameter and the incident energy for the former and 3-momentum for the latter. Scattering cross-sections are also calculated. Good agreement with well known results, including those of quantum electrodynamics, has been found.
Resumo:
Background: Molecular tools may help to uncover closely related and still diverging species from a wide variety of taxa and provide insight into the mechanisms, pace and geography of marine speciation. There is a certain controversy on the phylogeography and speciation modes of species-groups with an Eastern Atlantic-Western Indian Ocean distribution, with previous studies suggesting that older events (Miocene) and/or more recent (Pleistocene) oceanographic processes could have influenced the phylogeny of marine taxa. The spiny lobster genus Palinurus allows for testing among speciation hypotheses, since it has a particular distribution with two groups of three species each in the Northeastern Atlantic (P. elephas, P. mauritanicus and P. charlestoni) and Southeastern Atlantic and Southwestern Indian Oceans (P. gilchristi, P. delagoae and P. barbarae). In the present study, we obtain a more complete understanding of the phylogenetic relationships among these species through a combined dataset with both nuclear and mitochondrial markers, by testing alternative hypotheses on both the mutation rate and tree topology under the recently developed approximate Bayesian computation (ABC) methods. Results Our analyses support a North-to-South speciation pattern in Palinurus with all the South-African species forming a monophyletic clade nested within the Northern Hemisphere species. Coalescent-based ABC methods allowed us to reject the previously proposed hypothesis of a Middle Miocene speciation event related with the closure of the Tethyan Seaway. Instead, divergence times obtained for Palinurus species using the combined mtDNA-microsatellite dataset and standard mutation rates for mtDNA agree with known glaciation-related processes occurring during the last 2 my. Conclusion The Palinurus speciation pattern is a typical example of a series of rapid speciation events occurring within a group, with very short branches separating different species. Our results support the hypothesis that recent climate change-related oceanographic processes have influenced the phylogeny of marine taxa, with most Palinurus species originating during the last two million years. The present study highlights the value of new coalescent-based statistical methods such as ABC for testing different speciation hypotheses using molecular data.
Resumo:
OBJECTIVE: Examination of the rate of grade III or grade IV radiation dermatitis during treatment of head and neck cancer (HNC) with radiotherapy (RT) and concurrent cetuximab in EORTC centres. MATERIALS AND METHOD: A questionnaire was sent to all members of the EORTC Radiation Oncology Group and Head and Neck Group (111 institutions) to evaluate the widespread use of cetuximab and radiotherapy in HNC and to estimate the frequency of grades III and IV skin reactions in the radiation portals associated with this protocol. Co-morbidities, RT schedules and co-medications were also recorded. RESULTS: We received responses from 28 institutions in 11 countries. A total of 125 HNC patients from 15 institutions were treated with cetuximab and concurrent RT. Information about the skin reactions was available from 71 patients. Of these 36 had no grade III/IV adverse effects in the RT field, 15 had a grade III and 20 had grade IV radiation dermatitis. No detectable relation of grades III and IV radiation dermatitis with co-morbidities such as liver insufficiency or renal dysfunction was found. CONCLUSION: According to the results of the questionnaire, grade III/IV radiation dermatitis is observed in 49% of HNC patients treated with cetuximab and concurrent RT. A systematic clinical monitoring of cutaneous side effects during RT plus cetuximab is advised to ensure the safety of this protocol.
Resumo:
PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.
Resumo:
False identity documents constitute a potential powerful source of forensic intelligence because they are essential elements of transnational crime and provide cover for organized crime. In previous work, a systematic profiling method using false documents' visual features has been built within a forensic intelligence model. In the current study, the comparison process and metrics lying at the heart of this profiling method are described and evaluated. This evaluation takes advantage of 347 false identity documents of four different types seized in two countries whose sources were known to be common or different (following police investigations and dismantling of counterfeit factories). Intra-source and inter-sources variations were evaluated through the computation of more than 7500 similarity scores. The profiling method could thus be validated and its performance assessed using two complementary approaches to measuring type I and type II error rates: a binary classification and the computation of likelihood ratios. Very low error rates were measured across the four document types, demonstrating the validity and robustness of the method to link documents to a common source or to differentiate them. These results pave the way for an operational implementation of a systematic profiling process integrated in a developed forensic intelligence model.
Resumo:
Background: Preclinical data indicate activity of mammalian target of rapamycin inhibitors and synergistic activity together with radiotherapy in glioblastoma. The aim of this trial is to assess the therapeutic activity of temsirolimus (CCI-779), an intravenous mTOR inhibitor, in patients with newly diagnosed glioblastoma with unmethylated O6 methlyguanine-DNA-methlytransferase (MGMT)promoter. Methods: Patients (n=257) with newly diagnosed glioblastoma after open surgical biopsy or resection fulfilling basic eligibility criteria underwent a central MGMT promoter analysis using quantitative methylation specific PCR. Patients with glioblastoma harboring an unmethylated MGMT promoter (n=111) were randomized 1:1 between radiotherapy (60 Gy; 5 times 2 Gy per week) plus concomitant and six cycles of maintenance temozolomide or radiotherapy plus weekly temsirolimus at 25 mg flat dose to be continued until progression or undue toxicity. Primary endpoint was overall survival at 12 months (OS12). Sample size of the investigational treatment arm required 54 patients to assess adequacy of temsirolimus activity set at 80%. More than 38 patients alive at 12 months in the per protocol population was considered a positive signal. A control arm of 54 patients treated with the standard of care was implemented to evaluate the assumptions on OS12. Results: Between December 2009 and October 2012, 111 pts in 14 centers were randomized and treated. Median age was 55 and 58 years in the temsirolimus and standard arm, respectively. Most patients (95.5%) had a WHO performance status of 0 or 1. Both therapies were properly administered with a median of 13 cycles of maintenance temsirolimus. In the per protocolpopulation, exactly 38 patients treated with temsirolimus (out of 54 eligible) reached OS12. In the intention to treat population OS12 was 72.2% [95% CI (58.2, 82.2)] in the temozolomide arm and 69.6% [95% CI (55.8, 79.9) in the temsirolimus arm [HR=1.16 95% CI (0.77, 1.76), p=0.47]. Conclusions: The therapeutic activity of temsirolimus in patients with newly diagnosed glioblastoma with an unmethylated MGMT promoter is too low.
Resumo:
OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.
Resumo:
Purpose. To evaluate the impact of mobile devices and apps on the daily clinical activity of young radiation oncologists. Methods. A web-based questionnaire was sent to 382 young (≤40 years) members of the Italian Association of Radiation Oncology (AIRO). The 14 items investigated the diffusion of mobile devices (smartphones and/or tablets), their impact on daily clinical activity, and possible differences perceived by the participants over time. Results. A total of 158 questionnaires were available for statistical evaluation (response rate 41%). Up to 75% of respondents declared they used an electronic device during their clinical activity. Conversely, 82% considered the impact of smartphones/tables on daily practice low to moderate. Daily device use increased significantly from 2009 to 2012, with high daily use rates rising from 5% to 39.9%. Fulfillment of professional needs was declared by less than 42% of respondents and compliance with app indications by 32%. Almost all physicians desired in 2012 a comprehensive website concerning a variety of apps covering radiation oncologists' needs. Conclusions. Mobile devices are widely used by young Italian radiation oncologists in their daily clinical practice, while the indications so obtained are not always followed. Nevertheless, it would be important to verify the consistency of information found within apps, in order to avoid potential errors that might be detrimental to patients.
Resumo:
Depth-dose curves in LiF detectors of different effective thicknesses, together with their responses, were calculated for typical nuclear medicine radiation fields with 99mTc, 18F and 90Y sources. Responses were analysed in function of the radionuclide, detector effective thickness and irradiation geometry. On the other hand the results of the nuclear medicine measurement campaign of the ORAMED project were presented focussing on the dose distribution across the hand and on the appropriate position to wear the dosimeter.According to the results, thin LiF detectors provide better responses in all cases. Its use is essential for 18F, since thick dosimeters can underestimate Hp(0.07) up to a 50% because of the very inhomogeneous dose deposition on the active layer. The preliminary results of the measurement campaign showed that the index tip of the non-dominant hand is usually the most exposed position among the 22 monitored positions. It was also found that, in average, wrist dosimeters are likely to underestimate the maximum skin dose by a factor of the order of 20. This factor is reduced to around 6 for a ring dosimeter worn on the base of the index of the non-dominant hand. Thus, for typical nuclear medicine procedures, the base of the index of the non-dominant hand is recommended as the best monitoring option.