998 resultados para Radiation injury


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the impact of mobile devices and apps on the daily clinical activity of young radiation oncologists. Methods. A web-based questionnaire was sent to 382 young (≤40 years) members of the Italian Association of Radiation Oncology (AIRO). The 14 items investigated the diffusion of mobile devices (smartphones and/or tablets), their impact on daily clinical activity, and possible differences perceived by the participants over time. Results. A total of 158 questionnaires were available for statistical evaluation (response rate 41%). Up to 75% of respondents declared they used an electronic device during their clinical activity. Conversely, 82% considered the impact of smartphones/tables on daily practice low to moderate. Daily device use increased significantly from 2009 to 2012, with high daily use rates rising from 5% to 39.9%. Fulfillment of professional needs was declared by less than 42% of respondents and compliance with app indications by 32%. Almost all physicians desired in 2012 a comprehensive website concerning a variety of apps covering radiation oncologists' needs. Conclusions. Mobile devices are widely used by young Italian radiation oncologists in their daily clinical practice, while the indications so obtained are not always followed. Nevertheless, it would be important to verify the consistency of information found within apps, in order to avoid potential errors that might be detrimental to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To analyze the effect of tight glycemic control with the use of intensive insulin therapy on cerebral glucose metabolism in patients with severe brain injury. DESIGN: Retrospective analysis of a prospective observational cohort. SETTING: University hospital neurologic intensive care unit. PATIENTS: Twenty patients (median age 59 yrs) monitored with cerebral microdialysis as part of their clinical care. INTERVENTIONS: Intensive insulin therapy (systemic glucose target: 4.4-6.7 mmol/L [80-120 mg/dL]). MEASUREMENTS AND MAIN RESULTS: Brain tissue markers of glucose metabolism (cerebral microdialysis glucose and lactate/pyruvate ratio) and systemic glucose were collected hourly. Systemic glucose levels were categorized as within the target "tight" (4.4-6.7 mmol/L [80-120 mg/dL]) vs. "intermediate" (6.8-10.0 mmol/L [121-180 mg/dL]) range. Brain energy crisis was defined as a cerebral microdialysis glucose <0.7 mmol/L with a lactate/pyruvate ratio >40. We analyzed 2131 cerebral microdialysis samples: tight systemic glucose levels were associated with a greater prevalence of low cerebral microdialysis glucose (65% vs. 36%, p < 0.01) and brain energy crisis (25% vs.17%, p < 0.01) than intermediate levels. Using multivariable analysis, and adjusting for intracranial pressure and cerebral perfusion pressure, systemic glucose concentration (adjusted odds ratio 1.23, 95% confidence interval [CI] 1.10-1.37, for each 1 mmol/L decrease, p < 0.001) and insulin dose (adjusted odds ratio 1.10, 95% CI 1.04-1.17, for each 1 U/hr increase, p = 0.02) independently predicted brain energy crisis. Cerebral microdialysis glucose was lower in nonsurvivors than in survivors (0.46 +/- 0.23 vs. 1.04 +/- 0.56 mmol/L, p < 0.05). Brain energy crisis was associated with increased mortality at hospital discharge (adjusted odds ratio 7.36, 95% CI 1.37-39.51, p = 0.02). CONCLUSIONS: In patients with severe brain injury, tight systemic glucose control is associated with reduced cerebral extracellular glucose availability and increased prevalence of brain energy crisis, which in turn correlates with increased mortality. Intensive insulin therapy may impair cerebral glucose metabolism after severe brain injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A nation-wide survey on radiation doses in diagnostic and interventional radiology was conducted in Switzerland in 1998 aiming at establishing their collective radiological impact on the Swiss population. The study consisted on the one hand of surveying the frequency of more than 250 types of examinations, covering conventional radiology, mammography, fluoroscopy, angiography, interventional radiology, CT, bone densitometry, conventional tomography and dental radiology. On the other hand, for each type of examination the associated patient dose was established by modeling. The results of this study show that about 9.5 million diagnostic and interventional examinations are performed annually in Switzerland (1.34 per caput) and that the associated annual collective dose is of the order of 7100 person.Sv (1.0 mSv per caput). Switzerland is similar to other European countries in terms of the frequency of examinations and the collective dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about radiation protection for endoscopic procedures, in particular endoscopic retrograde cholangiopancreatography (ERCP). Particular cases, including pregnant women and pediatric patients, are also discussed. This Guideline was developed by a group of endoscopists and medical physicists to ensure that all aspects of radiation protection are adequately dealt with. A two-page executive summary of evidence statements and recommendations is provided. The target readership for this Guideline mostly includes endoscopists, anesthesiologists, and endoscopy assistants who may be exposed to X-rays during endoscopic procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brain Injury Quick Guide was developed as a resource tool for educators and school staff. Functional challenges (including social, physical, communication, and cognitive) are common following brain injury. This booklet serves as a resource outlining common challenges students may face in the classroom as well as strategies for addressing these challenges. Case studies outlining common challenges with possible strategies are provided with suggestions for IEP/504 plan accommodations. Basic brain anatomy and brain injury statistics are also reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefit of induced hyperventilation for intracranial pressure (ICP) control after severe traumatic brain injury (TBI) is controversial. In this study, we investigated the impact of early and sustained hyperventilation on compliances of the cerebral arteries and of the cerebrospinal (CSF) compartment during mild hyperventilation in severe TBI patients. We included 27 severe TBI patients (mean 39.5 ± 3.4 years, 6 women) in whom an increase in ventilation (20% increase in respiratory minute volume) was performed during 50 min as part of a standard clinical CO(2) reactivity test. Using a new mathematical model, cerebral arterial compliance (Ca) and CSF compartment compliance (Ci) were calculated based on the analysis of ICP, arterial blood pressure, and cerebral blood flow velocity waveforms. Hyperventilation initially induced a reduction in ICP (17.5 ± 6.6 vs. 13.9 ± 6.2 mmHg; p < 0.001), which correlated with an increase in Ci (r(2) = 0.213; p = 0.015). Concomitantly, the reduction in cerebral blood flow velocities (CBFV, 74.6 ± 27.0 vs. 62.9 ± 22.9 cm/sec; p < 0.001) marginally correlated with the reduction in Ca (r(2) = 0.209; p = 0.017). During sustained hyperventilation, ICP increased (13.9 ± 6.2 vs. 15.3 ± 6.4 mmHg; p < 0.001), which correlated with a reduction in Ci (r(2) = 0.297; p = 0.003), but no significant changes in Ca were found during that period. The early reduction in Ca persisted irrespective of the duration of hyperventilation, which may contribute to the lack of clinical benefit of hyperventilation after TBI. Further studies are needed to determine whether monitoring of arterial and CSF compartment compliances may detect and prevent an adverse ischemic event during hyperventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. METHODS: We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDIvol), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. RESULTS: For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDIvol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. CONCLUSION: We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background : Numerous studies have shown that immune cells infiltrate the spinal cord after peripheral nerve injury and that they play a major contribution to sensory hypersensitivity in rodents. In particular, the role of monocyte-derived cells and T lymphocytes seems to be prominent in this process. This exciting new perspective in research on neuropathic pain opens many different areas of work, including the understanding of the function of these cells and how they impact on neural function. However, no systematic description of the time course or cell types that characterize this infiltration has been published yet, although this seems to be the rational first step of an overall understanding of the phenomenon. Objective : Describe the time course and cell characteristics of T lymphocyte infiltration in the spinal cord in the Spared Nerve Injury (SNI) model of neuropathic pain in rats. Methods : Collect of lumbar spinal cords of rats at days 2, 7, 21 and 40 after SNI or sham operation (n=4). Immunofluorescence detecting different proteins of T cell subgroups (CD2+CD4+, CD2+CD8+, Th1 markers, Th2 markers, Th17 markers). Quantification of the infiltration rate of the different subgroups. Expected results : First, we expect to see an infiltration of T cells in the spinal cord ipsilateral to nerve injury, higher in SNI rats than in sham animals. Second, we anticipate that different subtypes of T cells penetrate at different time points. Finally, the number of T lymphocytes are expected to decrease at the latest time point, showing a resolution of the process underlying their infiltrating the spinal cord in the first place. Impact : A systematic description of the infiltration of T cells in the spinal cord after peripheral nerve injury is needed to have a better understanding of the role of immune cells in neuropathic pain. The time course that we want to establish will provide the scientific community with new perspectives. First, it will confirm that T cells do indeed infiltrate the spinal cord after SNI in rats. Second, the type of T cells infiltrating at different time points will give clues about their function, in particular their inflammatory or anti-inflammatory profile. From there on, other studies could be lead, investigating the functional side of the specific subtypes put to light by us. Ultimately, this could lead to the discovery of new drugs targeting T cells or their infiltration, in the hope of improving neuropathic pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: p53 point mutations represent potential tumor-specific cytolytic T lymphocyte (CTL) epitopes. Whether ionizing radiation (IR) alters the immunological properties of cells expressing mutant p53 in respect of the CTL epitope generated by a defined point mutation has not been evaluated. METHODS: Mutant p53-expressing syngeneic, nontumor forming BALB/c 3T3 fibroblasts, tumor forming ras-transfected BALB/c 3T3 sarcomas, and DBA/2-derived P815 mastocytoma cells, which differ at the level of minor histocompatibility antigens, were used as cellular vaccines. Cells were either injected with or without prior IR into naive BALB/c mice. Cellular cytotoxicity was assessed after secondary restimulation of effector spleen cells in vitro. RESULTS: Injection of P815 mastocytoma cells expressing the mutant p53 induced mutation-specific CTL in BALB/c mice irrespective of prior irradiation. However, syngeneic fibroblasts or fibrosarcomas endogenously expressing mutant p53 were able to induce significant mutation-specific CTL only when irradiated prior to injection into BALB/c mice. IR of fibroblasts did not detectably alter the expression of cell surface molecules involved in immune response induction, nor did it alter the short-term in vitro viability of the fibroblasts. Interestingly, radioactively-labeled fibroblasts injected into mice after irradiation showed altered organ distribution, suggesting that the in vivo fate of these cells may play a crucial role in their immunogenicity. CONCLUSIONS: These findings indicate that IR can alter the immunogenicity of syngeneic normal as well as tumor forming fibroblasts in vivo, and support the view that ionizing radiation enhances immunogenicity of cellular tumor vaccines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the albedo (r) and estimates of net radiation and global solar irradiance for green beans crop (Phaseolus vulgaris L.), cultivated in greenhouse with cover of polyethylene and field conditions, in Botucatu, SP, Brazil (22º 54' S; 48º 27' W; 850 m). The solar global irradiance (Rg) and solar reflected radiation (Rr) were used to estimate the albedo through the ratio between Rr and Rg. The diurnal curves of albedo were obtained for days with clear sky and partially cloudy conditions, for different phenological stages of the crop. The albedo ranged with the solar elevation, the environment and the phenological stages. The cloudiness range have almost no influence on the albedo diurnal amount. The estimation of radiation were made by linear regression, using the global solar irradiance (Rg) and net short-waves radiation (Rc) as independent variables. All estimates of radiation showed better adjustment for specific phenological periods compared to the entire crop growing cycle. The net radiation in the greenhouse has been estimated by the global solar irradiance measured at field conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper was to describe the radiation and energy balance, during the lettuce (Lactuca sativa, L. cv. Verônica) crop cycle inside a polyethylene greenhouse. The radiation and energy balance was made inside a tunnel greenhouse with polyethylene cover (100 mum) and in an external area, both areas with 35 m². Global, reflected and net radiation, soil heat flux and air temperature (dry and humid) were measured during the crop cycle. A Datalogger, which operated at 1 Hz frequency, storing 5 minutes averages was utilized. The global (K¯) and reflected (K­) radiations showed that the average transmission of global radiation (K¯in / K¯ex) was almost constant, near to 79.59%, while the average ratio of reflected radiation (K­in / K­ex) was 69.21% with 8.47% standard-deviation. The normalized curves of short-wave net radiation, in relation to the global radiation (K*/ K¯), found for both environments, were almost constant at the beginning of cycle; this relation decreased in the final stage of culture. The normalized relation (Rn/ K¯) was bigger in the external area, about 12%, when the green culture covered the soil surface. The long-wave radiation balance average (L*) was bigger outside, about 50%. The energy balance, estimated in terms of vertical fluxes, showed that, for the external area, in average, 83.07% of total net radiation was converted in latent heat evaporation (LE), and 18% in soil heat flux (G), and 9.96% in sensible heat (H), while inside of the greenhouse, 58.71% of total net radiation was converted in LE, 42.68% in H, and 28.79% in G.