967 resultados para Polyphosphates quantification
Resumo:
A scintillation proximity assay (SPA) has been used successfully to detect and quantify, in real-time, the kinetic progress of hydrolysis of [ H]acetate esters from scintillant-containing styrenic and poly(ethylene glycol) (PEG)-based polymer supports in both organic and aqueous media.
Resumo:
Background - An evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10–2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD. Methods - 10–2 SAP and SWAP Humphrey visual fields and stereoscopic fundus photographs were collected in 27 eyes of 27 patients with AMD and 22 eyes of 22 normal subjects. Results - Mean Deviation and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post hoc analysis revealed overlap of functional values among stages. In SWAP, indices of focal loss were more sensitive to detecting differences in AMD from normal. SWAP defects were greater in depth and area than those in SAP. Central sensitivity (within 1°) changed by -3.9 and -4.9 dB per stage in SAP and SWAP, respectively. Based on defect maps, an AMD Severity Index was derived. Conclusions - Global indices of focal loss were more sensitive to detecting early stage AMD from normal. The SWAP sensitivity decline with advancing stage of AMD was greater than in SAP. A new AMD Severity Index quantifies visual field defects on a continuous scale. Although not all patients are suitable for SWAP examinations, it is of value as a tool in research studies of visual loss in AMD.
Resumo:
Presentation Purpose:To determine methods of quantifying the sensitivity loss in the central 10o visual field in a cross section of patients at various stages of age-related macular degeneration (AMD). Methods:Standard and short-wavelength automated perimetry (SAP and SWAP) visual fields were collected using program 10-2 of the Humphrey Field Analyzer, in 44 eyes of 27 patients with AMD and 41 eyes of 22 normal subjects. Stereoscopic fundus photographs were graded by two independent observers and the stage of disease determined. Global indices were compared for their ability to delineate the normal visual field from early stages of AMD and to differentiate between stages. Results:Mean Deviation (MD) and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post-hoc analysis revealed overlap of functional values between stages. Global indices of focal loss, PSD and local spatial variability (LSV) were the most sensitive to detecting differences between normal subjects and early stage AMD patients, in SAP and SWAP, respectively. Overall, defects were confined to the central 5°. SWAP defects were consistently greater in depth and area than those in SAP. The most vulnerable region of the 10° field to sensitivity loss with increasing stage of AMD was the central 1°, in which the sensitivity decline was -4.8dB per stage in SAP and -4.9dB per stage in SWAP. Based on the pattern deviation defect maps, a severity index of AMD visual field loss was derived. Threshold variability was considerably increased in late stage AMD eyes. Conclusions:Global indices of focal loss were more sensitive to the detection of early stage AMD from normal. The sensitivity decline with advancing stage of AMD was greater in SWAP compared to SAP, however the trend was not strong across all stages of disease. The less commonly used index LSV represents relatively statistically unmanipulated summary measure of focal loss. A new severity index is described which is sensitive to visual field change in AMD, measures visual field defects on a continuous scale and may serve as a useful measure of functional change in AMD in longitudinal studies. Keywords: visual fields • age-related macular degeneration • perimetry
Resumo:
Presentation Purpose:To relate structural change to functional change in age-related macular degeneration (AMD) in a cross-sectional population using fundus imaging and the visual field status. Methods:10 degree standard and SWAP visual fields and other standard functional clinical measures were acquired in 44 eyes of 27 patients at various stages of AMD, as well as fundus photographs. Retro-mode SLO images were captured in a subset of 29 eyes of 19 of the patients. Drusen area, measured by automated drusen segmentation software (Smith et al. 2005) was correlated with visual field data. Visual field defect position was compared to the position of the imaged drusen and deposits using custom software. Results:The effect of AMD stage on drusen area within the 6000µm was significant (One-way ANOVA: F = 17.231, p < 0.001), however the trend was not strong across all stages. There were significant linear relationships between visual field parameters and drusen area. The mean deviation (MD) declined by 3.00dB and 3.92dB for each log % drusen area for standard perimetry and SWAP, respectively. The visual field parameters of focal loss displayed the strongest correlations with drusen area. The number of pattern deviation (PD) defects increased by 9.30 and 9.68 defects per log % drusen area for standard perimetry and SWAP, respectively. Weaker correlations were found between drusen area and visual acuity, contrast sensitivity, colour vision and reading speed. 72.6% of standard PD defects and 65.2% of SWAP PD defects coincided with retinal signs of AMD on fundus photography. 67.5% of standard PD defects and 69.7% of SWAP PD defects coincided with deposits on retro-mode images. Conclusions:Perimetry exhibited a stronger relationship with drusen area than other measures of visual function. The structure-function relationship between visual field parameters and drusen area was linear. Overall the indices of focal loss had a stronger correlation with drusen area in SWAP than in standard perimetry. Visual field defects had a high coincidence proportion with retinal manifestations of AMD.Smith R.T. et al. (2005) Arch Ophthalmol 123:200-206.
Resumo:
The standard reference clinical score quantifying average Parkinson's disease (PD) symptom severity is the Unified Parkinson's Disease Rating Scale (UPDRS). At present, UPDRS is determined by the subjective clinical evaluation of the patient's ability to adequately cope with a range of tasks. In this study, we extend recent findings that UPDRS can be objectively assessed to clinically useful accuracy using simple, self-administered speech tests, without requiring the patient's physical presence in the clinic. We apply a wide range of known speech signal processing algorithms to a large database (approx. 6000 recordings from 42 PD patients, recruited to a six-month, multi-centre trial) and propose a number of novel, nonlinear signal processing algorithms which reveal pathological characteristics in PD more accurately than existing approaches. Robust feature selection algorithms select the optimal subset of these algorithms, which is fed into non-parametric regression and classification algorithms, mapping the signal processing algorithm outputs to UPDRS. We demonstrate rapid, accurate replication of the UPDRS assessment with clinically useful accuracy (about 2 UPDRS points difference from the clinicians' estimates, p < 0.001). This study supports the viability of frequent, remote, cost-effective, objective, accurate UPDRS telemonitoring based on self-administered speech tests. This technology could facilitate large-scale clinical trials into novel PD treatments.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
Objective: Development and validation of a selective and sensitive LCMS method for the determination of methotrexate polyglutamates in dried blood spots (DBS). Methods: DBS samples [spiked or patient samples] were prepared by applying blood to Guthrie cards which was then dried at room temperature. The method utilised 6-mm disks punched from the DBS samples (equivalent to approximately 12 μl of whole blood). The simple treatment procedure was based on protein precipitation using perchloric acid followed by solid phase extraction using MAX cartridges. The extracted sample was chromatographed using a reversed phase system involving an Atlantis T3-C18 column (3 μm, 2.1x150 mm) preceded by Atlantis guard column of matching chemistry. Analytes were subjected to LCMS analysis using positive electrospray ionization. Key Results: The method was linear over the range 5-400 nmol/L. The limits of detection and quantification were 1.6 and 5 nmol/L for individual polyglutamates and 1.5 and 4.5 nmol/L for total polyglutamates, respectively. The method has been applied successfully to the determination of DBS finger-prick samples from 47 paediatric patients and results confirmed with concentrations measured in matched RBC samples using conventional HPLC-UV technique. Conclusions and Clinical Relevance: The methodology has a potential for application in a range of clinical studies (e.g. pharmacokinetic evaluations or medication adherence assessment) since it is minimally invasive and easy to perform, potentially allowing parents to take blood samples at home. The feasibility of using DBS sampling can be of major value for future clinical trials or clinical care in paediatric rheumatology. © 2014 Hawwa et al.
Resumo:
Background: Ketorolac, a potent nonsteroidal anti-inflammatory drug used for pain control in children, exists as a racemate of inactive R (+) and active S (-) enantiomers. Aim: To develop a microsampling assay for the enantioselective analysis of ketorolac in children. Methods: Ketorolac enantiomers were extracted from 50 µl of plasma by liquid–liquid extraction and separated on a ChiralPak AD-RH. Detection was by a TSQ quantum triple quadrupole mass spectrometer with an electrospray ionisation source operating in a positive ion mode. Five children (age 13.8 (1.6) years, weight 52.7 (7.2) kg), were administered intravenous ketorolac 0.5 mg/kg (maximum 10 mg) and blood samples were taken at 0, 0.25, 0.5, 1, 2, 4, 6, 8 and 12 h post administration. CL, VD and t1/2 were calculated based on non-compartmental methods. Results: The standard curves for R (+) and S (-) ketorolac were linear in the range 0–2000 ng/ml. The LLOQs of the method were 0.15 ng on column and 0.31 ng on column for R (+) and S (-) ketorolac, respectively. The median (range) VD and CL of R (+) and S (-) ketorolac were 0.12 l/kg (0.07–0.17), 0.017 l/h/kg (0.12–0.29) and 0.17 (0.09–0.31) l/kg, 0.049 (0.02–0.1) l/h/kg, p = 0.043), respectively. The median (range) elimination half-life (t1/2) of the R (+) and S (-) ketorolac was 5.0 h (2.5–5.8) and 3.1 h (1.8–4.4), p = 0.043), respectively. Conclusion: The development of a simple, rapid and reliable ketorolac assay suitable for paediatric PK studies is reported. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
An increasing number of publications on the dried blood spot (DBS) sampling approach for the quantification of drugs and metabolites have been spurred on by the inherent advantages of this sampling technique. In the present research, a selective and sensitive high-performance liquid chromatography method for the concurrent determination of multiple antiepileptic drugs (AEDs) [levetiracetam (LVT), lamotrigine (LTG), phenobarbital (PHB)], carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE)] in a single DBS has been developed and validated. Whole blood was spotted onto Guthrie cards and dried. Using a standard punch (6 mm diameter), a circular disc was punched from the card and extracted with methanol: acetonitrile (3:1, v/v) containing hexobarbital (Internal Standard) and sonicated prior to evaporation. The extract was then dissolved in water and vortex mixed before undergoing solid phase extraction using HLB cartridges. Chromatographic separation of the AEDs was achieved using Waters XBridge™ C18 column with a gradient system. The developed method was linear over the concentration ranges studied with r ≥ 0.995 for all compounds. The lower limits of quantification (LLOQs) were 2, 1, 2, 0.5 and 1 μg/mL for LVT, LTG, PHB, CBZE and CBZ, respectively. Accuracy (%RE) and precision (%CV) values for within and between day were <20% at the LLOQs and <15% at all other concentrations tested. This method was successfully applied to the analysis of the AEDs in DBS samples taken from children with epilepsy for the assessment of their adherence to prescribed treatments.
Resumo:
Introduction: Gene therapy continues to grow as an important area of research, primarily because of its potential in the treatment of disease. One significant area where there is a need for better understanding is in improving the efficiency of oligonucleotide delivery to the cell and indeed, following delivery, the characterization of the effects on the cell. Methods: In this report, we compare different transfection reagents as delivery vehicles for gold nanoparticles functionalized with DNA oligonucleotides, and quantify their relative transfection efficiencies. The inhibitory properties of small interfering RNA (siRNA), single-stranded RNA (ssRNA) and single-stranded DNA (ssDNA) sequences targeted to human metallothionein hMT-IIa are also quantified in HeLa cells. Techniques used in this study include fluorescence and confocal microscopy, qPCR and Western analysis. Findings: We show that the use of transfection reagents does significantly increase nanoparticle transfection efficiencies. Furthermore, siRNA, ssRNA and ssDNA sequences all have comparable inhibitory properties to ssDNA sequences immobilized onto gold nanoparticles. We also show that functionalized gold nanoparticles can co-localize with autophagosomes and illustrate other factors that can affect data collection and interpretation when performing studies with functionalized nanoparticles. Conclusions: The desired outcome for biological knockdown studies is the efficient reduction of a specific target; which we demonstrate by using ssDNA inhibitory sequences targeted to human metallothionein IIa gene transcripts that result in the knockdown of both the mRNA transcript and the target protein. © 2014 Jiwaji et al.
Resumo:
Nitration of tyrosine in proteins and peptides is a post-translational modification that occurs under conditions of oxidative stress. It is implicated in a variety of medical conditions, including neurodegenerative and cardiovascular diseases. However, monitoring tyrosine nitration and understanding its role in modifying biological function remains a major challenge. In this work, we investigate the use of electron-vibration-vibration (EVV) two-dimensional infrared (2DIR) spectroscopy for the study of tyrosine nitration in model peptides. We demonstrate the ability of EVV 2DIR spectroscopy to differentiate between the neutral and deprotonated states of 3-nitrotyrosine, and we characterize their spectral signatures using information obtained from quantum chemistry calculations and simulated EVV 2DIR spectra. To test the sensitivity of the technique, we use mixed-peptide samples containing various levels of tyrosine nitration, and we use mass spectrometry to independently verify the level of nitration. We conclude that EVV 2DIR spectroscopy is able to provide detailed spectroscopic information on peptide side-chain modifications and to detect nitration levels down to 1%. We further propose that lower nitration levels could be detected by introducing a resonant Raman probe step to increase the detection sensitivity of EVV 2DIR spectroscopy. (Graph Presented).
Resumo:
Oxidised biomolecules in aged tissue could potentially be used as biomarkers for age-related diseases; however, it is still unclear whether they causatively contribute to ageing or are consequences of the ageing process. To assess the potential of using protein oxidation as markers of ageing, mass spectrometry (MS) was employed for the identification and quantification of oxidative modifications in obese (ob/ob) mice. Lean muscle mass and strength is reduced in obesity, representing a sarcopenic model in which the levels of oxidation can be evaluated for different muscular systems including calcium homeostasis, metabolism and contractility. Several oxidised residues were identified by tandem MS (MS/MS) in both muscle homogenate and isolated sarcoplasmic reticulum (SR), an organelle that regulates intracellular calcium levels in muscle. These modifications include oxidation of methionine, cysteine, tyrosine, and tryptophan in several proteins such as sarcoplasmic reticulum calcium ATPase (SERCA), glycogen phosphorylase, and myosin. Once modifications had been identified, multiple reaction monitoring MS (MRM) was used to quantify the percentage modification of oxidised residues within the samples. Preliminary data suggests proteins in ob/ob mice are more oxidised than the controls. For example SERCA, which constitutes 60-70% of the SR, had approximately a 2-fold increase in cysteine trioxidation of Cys561 in the obese model when compared to the control. Other obese muscle proteins have also shown a similar increase in oxidation for various residues. Further analysis with complex protein mixtures will determine the potential diagnostic use of MRM experiments for analysing protein oxidation in small biological samples such as muscle needle biopsies.
Resumo:
Self-adaptive systems (SASs) should be able to adapt to new environmental contexts dynamically. The uncertainty that demands this runtime self-adaptive capability makes it hard to formulate, validate and manage their requirements. QuantUn is part of our longer-term vision of requirements reflection, that is, the ability of a system to dynamically observe and reason about its own requirements. QuantUn's contribution to the achievement of this vision is the development of novel techniques to explicitly quantify uncertainty to support dynamic re-assessment of requirements and therefore improve decision-making for self-adaption. This short paper discusses the research gap we want to fill, present partial results and also the plan we propose to fill the gap.
Resumo:
Degeneration of white matter fibre tracts occurs in several neurodegenerative disorders and results in various histological abnormalities including loss of axons, vacuolation, gliosis, axonal varicosities and spheroids, corpora amylacea, extracellular protein deposits, and glial inclusions (GI). This chapter describes quantitative studies that have been carried out on white matter pathology in a variety of neurodegenerative disease. First, in Alzheimer’s disease (AD), axonal loss quantified in histological sections stained with toluidine blue, occurs in several white matter fibre tracts including the optic nerve, olfactory tract, and corpus callosum. Second, in Creutzfeldt-Jakob disease (CJD), sections of cerebral cortex stained with haematoxylin and eosin (H/E) or immunolabelled with antibodies against the disease form of prion protein (PrPsc), reveal extensive vacuolation, gliosis of white matter, and deposition of PrPsc deposits. Third, GI immunolabelled with antibodies against various pathological proteins including tau, -synuclein, TDP-43, and FUS, have been recorded in white matter of a number of disorders including frontotemporal lobar degeneration (FTLD), progressive supranuclear palsy (PSP), multiple system atrophy (MSA), and neuronal intermediate filament inclusion disease (NIFID). Axonal varicosities have also been observed in NIFID. There are two important questions regarding white matter pathology that need further investigation: (1) what is the relative importance of white and gray matter pathologies in different disorders and (2) do white matter abnormalities precede or are they the consequence of gray matter pathology?
Resumo:
This dissertation combines three separate studies that measure coastal change using airborne laser data. The initial study develops a method for measuring subaerial and subaqueous volume change incrementally alongshore, and compares those measurements to shoreline change in order to quantify their relationship in Palm Beach County, Florida. A poor correlation (R2 = 0.39) was found between shoreline and volume change before the hurricane season in the northern section of Palm Beach County because of beach nourishment and inlet dynamics. However, a relatively high R2 value of 0.78 in the southern section of Palm Beach County was found due to little disturbance from tidal inlets and coastal engineering projects. The shoreline and volume change caused by the 2004 hurricane season was poorly correlated with R 2 values of 0.02 and 0.42 for the north and south sections, respectively. The second study uses airborne laser data to investigate if there is a significant relationship between shoreline migration before and after Hurricane Ivan near Panama City, Florida. In addition, the relationship between shoreline change and subaerial volume was quantified and a new method for quantifying subaqueous sediment change was developed. No significant spatial relationship was found between shoreline migration before and after the hurricane. Utilization of a single coefficient to represent all relationships between shoreline and subaerial volume change was found to be problematic due to the spatial variability in the linear relationship. Differences in bathymetric data show only a small portion of sediment was transported beyond the active zone and most sediment remained within the active zone despite the occurrence of a hurricane. The third study uses airborne laser bathymetry to measure the offshore limit of change, and compares that location with calculated depth of closures and subaqueous geomorphology. There appears to be strong geologic control of the depth of closure in Broward and Miami-Dade Counties. North of Hillsboro Inlet, hydrodynamics control the geomorphology which in turn indicates the location of the depth of closure.