682 resultados para Plastic film covering
Resumo:
The photoelectrochemical degradation of p-nitrophenol (PNP) was investigated using titanium dioxide thin-film photoelectrode. The effects of different supporting electrolytes, pH, applied potential and PNP concentration were examined and discussed. Complete photodegradation was obtained in perchlorate medium at pH 2 when the photoanode was biased at +1.0 V (versus SCE) during a 3-h experiment. Under these conditions, carbon removal of approximately 60% was achieved. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
The determination of lead ions directly in water, for application in analysis of samples of environmental interest, was studied by electroanalytical techniques. Linear sweep anodic stripping voltammetry with a carbon fiber disk ultramicroelectrode (7.0 mu m in diameter), without mercury film, has been used for lead determination, by standard addition, in purified water in the absence of supporting electrolyte. The response was linear in the range from 10.0 to 50.0 mu g L-1, with a detection limit of 0.8 mu g L-1, for 300 s preconcentration time, at -1.2 V and 1.0 V s(-1) scan rate. The reliability of the analytical procedure was evaluated by precision using relative standard deviations (5.6%, for three repetitive stripping current measurements of solution with 10.0 mu g L-1 lead ions) and by the accuracy with recovery experiments (mean of 110.8%) for the same concentration.
Resumo:
Stingrays are elasmobranchs found along the seacoast and in some rivers of Brazil. Pain is the most conspicuous symptom observed in patients wounded by the bilaterally retroserrate stingers located in the tail, which are covered by glandular and integument tissues. In addition, cutaneous necrosis is commonly observed in injuries caused by freshwater stingrays. The aim of this work was to characterize and compare certain properties of tissue extracts obtained from the glandular tissues covering the stinger apparatus of Potamotrygon falkneri and Dasyatis guttata stingrays. By sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), tissue extracts have similar bands above 80kDa, but most differences were observed below this molecular mass. Lethal, dermonecrotic and myotoxic activities were detected only in P. falkneri tissue extract. Edematogenic activity was similar and dose dependent in both tissue extracts. Nociceptive activity was verified in both tissue extracts, but P. falkneri presented a two-fold higher activity than D. guttata tissue extract. No direct hemolysis, phospholipase A(2) and coagulant activities were observed in both tissue extracts. Antigenic cross-reactivity was noticed by ELISA and Western blotting, using antisera raised in rabbits. Species-specific sera reacted with several components of both tissue extracts, noticeably above 22 kDa. Both tissue extracts presented gelatinolytic, caseinolytic and fibrinogenolytic activities, which were not caused by the action of metalloproteinases. Hyaluronidase activity was detected only in P. falkneri tissue extract. Our experimental observations suggest that P. falkneri tissue extract is more toxic than D. guttata tissue extract. These results may explain why injuries caused by freshwater stingrays are more severe in human accidents. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A sensitive method based on square wave voltammetry is described for the quantitative determination of elemental sulfur, disulfide and mercaptan in gasoline using a mercury film electrode. These sulfur compounds can be quantified by direct dissolution of gasoline in a supporting electrolyte followed by subsequent voltammetric measurement. The supporting electrolyte is 1.4 mol L-1 sodium acetate and No acetic acid in methanol. Chemical and optimum operational conditions for the formation of the mercury film were analyzed in this study. The values obtained were a 4.3 mu m thickness for the mercury film, a 1000 rpm rotation frequency, -0.9 V applied potential and 600 s depositing time. Voltammetric measurements were obtained using square wave voltammetry with detection limits of the 3.0 x 10(-9), 1.6 x 10(-7) and 4.9 x 10(-7) mol L-1 for elemental sulfur, disulfide and mercaptan, respectively. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)