754 resultados para Objective visual acuity
Resumo:
Purpose: The aims of this study were to compare angle of deviation, fusional vergence measurements and fusion reserve ratio between esophoria and exophoria. Methods: A cross-sectional study was performed in children with best-corrected visual acuity of 0.0 LogMAR in either eye, compensated heterophoria within 10 prism dioptres (PD), full ocular rotations, presence of fusional vergence and stereopsis (60 seconds of arc or better). Fusional amplitudes were compared between angle of deviation (2, 4, 6, 8 and 10 PD) in esophoria and exophoria. The fusion reserve ratio was calculated (to assess the effect of the underlying angle of deviation) as fusional convergence divided by prism alternating cover test measurements. Results: Two-hundred and eleven children (7.65±1.16 years) were recruited to this study. Exophoria was most common for near (n=181; 85.8%) and distance (n=20; 9.5%). Esophoria was present in 22 children for near (10.4%) and in 1 child for distance (0.5%). No significant differences were found between fusional amplitudes and angle of deviation for near (p>0.05). Children with exophoria of 10PD had a slight, but not, significant (p=0.264) increase in fusional convergence from 2PD (19.95±5.09) to 10PD (26.67±5.77). In esophoric children the variation of fusional convergence was smaller from 2P (25.00±0.00) to 10PD (22.50±3.54) and non significant (p=0.185). The fusion reserve ratio was significantly smaller in children with higher deviations (i.e. 10PD) for both esophoria (p=0.003) and exophoria (p>0.001). The fusion reserve ratio ranged between 12.50 (2PD) and 2.25±0.35 (10PD) for esophoria and between 9.98±2.55 (2PD) and 2.67±0.58 (10PD) for exophoria. Conclusions: Angle of deviation is not an efficient measure to predict fusional amplitudes. The fusion reserve ratio appears to be a better measurement to assess the effect of the underlying angle of deviation on fusional convergence. More studies are necessary to understand better the relationship between fusion amplitudes and angle of deviation.
Resumo:
Obiective. This study assesses the descriptive epidemiology of children with eye injuries presenting to the Emergency Department of a non exclusive Paediatric University Hospital - First Division of Ophthalmology of “Sapienza” University of Rome - over a period of 12 years. Study Design. A retrospective long term study of 12 years. Participants. All paediatric patients (up to 14 years of age) presenting with ocular injuries and hospitalized. Methods. It was analyzed the incidence of the ocular trauma among males and females. The situation in which the trauma occurred, type of trauma (contusive or perforating), the presence of endo-bulbar foreign bodies, visual acuity outcome. Results. There were 203 patients who presented to the Emergency Department in the period examined. Contusive traumas were 130 (90 males, 40 females). The perforating trauma were 73 (63 males, 10 females). The presence of an endo-bulbar foreign body was registered in 10 patients. A detailed analysis of the causes of the trauma is therefore provided. We evidence that males were almost exclusively involved in sport traumas (60 males versus 2 females), and in second instance accidental trauma is almost equally divided between two genders. Conclusions. Our retrospective study presents the paediatric cases of a non exclusive Paediatric University Hospital where 3% of ocular traumas requiring hospitalization were in children. Therefore our data could be useful in order to bring about the necessary preventive measures to minimize paediatric eye injuries.
Resumo:
This review evaluates the outcomes of intrastromal corneal ring segment (ICRS) implantation for the treatment of keratoconus considering a new grading system based on the preoperative visual impairment of the patient. Additionally, a five-year follow-up analysis of patients with stable and progressive keratoconus is performed in order to assess the long term stability of the surgical procedure. Corrected distance visual acuity decreased statistically significantly in patients with mild keratoconus (P < 0.01) but statistically significantly increased in all other grades (P < 0.05). The improvement in visual acuity and the decrease of keratometric and aberrometric values were stable throughout a long period of time in patients with stable keratoconus. In patients with progressive form keratoconus, a significant improvement was found immediately after the procedure, however clinically relevant regression greater than 3 D was observed at the end of the follow up period.
Resumo:
Purpose: Albinism is a rare genetic disorder of melanin production, which can affect only eyes or simultaneously eyes and skin/hair, resulting respectively in ocular (OA) or oculocutaneous albinism (OCA). Through of a case report of a child with OCA we pretend review ophthalmological manifestations of albinism. Case Report: A girl of West African descent was referenced to our appointment for ophthalmological evaluation of oculocutaneous albinism. Visual acuity was 20/310 OD e 20/630 OS by teller cards. In biomicroscopy, iris hypopigmentation and transillumination was visible, allowing to see spiral vessels and other iris details. Fundoscopy showed a denser and complex choroidal circulation due to lack of pigment in retinal pigment epithelium. Foveal hypoplasia was assumed because foveal pit is not apparent and vessels become less respectful of normal arcade and transverse the macula. Results: Melanin plays an important role in the development of the optic system and it’s absence leads to diverse ocular manifestations, such as: iris hypopigmentation and transillumination , reducted pigmentation of retinal pigment epithelium cells, photoreceptor rod cell deficits, foveal hypoplasia, optic nerve hypoplasia and misrouting of optic nerve at the chiasm, with temporal retina fibers inappropriately routed contralaterally instead of ipsilaterally. Photophobia, nystagmus, reduced visual acuity, color impairment and strabismus are other manifestations usually seen in albinism. Conclusion: Ophthalmologists must be familiar with the specific visual manifestations and needs of these patients. It is essential to correct refractive error to optimize visual acuity. Patients should also be advised to wear tinted glasses and sunblock. In more severely affected children they may benefit of low vision consultation and specialized low vision aids like telescopes.
Resumo:
Purtscher-like retinopathy is associated with retinal hemorrhages and ischaemia probably due to the complement-mediated leukoembolization. It is a rare and severe angiopathy found in conditions such as acute pancreatitis. Case. We present a case of a 53-year-old man who presented with a Purtscher-like retinopathy associated with the development of acute pancreatitis in the context of a Klatskin tumour (a hilar cholangiocarcinoma). The ophthalmologic evaluation revealed the best corrected visual acuity (BCVA) of 20/32 in the right eye (RE) and of 20/40 in the left eye (LE); biomicroscopy of anterior segment showed scleral icterus and fundoscopy revealed peripapillary cotton-wool spots, optic disc edema, and RPE hypo- and hyperpigmentation in the middle peripheral retina in both eyes with an intraretinal hemorrhage in the LE. 15 months after the initial presentation, without ophthalmological treatment, there was an improvement of BCVA to 20/20 in both eyes and optical coherence tomography (OCT) revealed areas of reduction of retinal nerve fiber layer thickness corresponding to the previous cotton-wool spots. Conclusion. Purtscher-like retinopathy should not be neglected in complex clinical contexts. Its unclear pathophysiology determines an uncertain treatment strategy, but a meticulous follow-up is compulsory in order to avoid its severe complications.
Resumo:
The crystalline lens allows the eye to focus on near and far objects. During the aging process, it loses its ability to focus and often becomes cloudy during cataract formation. At this point, traditional medical therapy replaces the lens with an artificial replacement lens. Although replacement lenses for the crystalline lens have been implanted since 1949 for cataract surgery, none of the FDA-approved lenses mimic the anatomy of the natural lens. Hence, they are not able to focus in a manner similar to the youthful lens. Instead, they function in a manner similar to the aged lens and only provide vision at a single distance or at a very limited range of focal distances. Patients with the newest implants are often obliged to use reading glasses when using near vision, or suffer from optical aberrations, halos, or glare. Therefore, there is a need to provide youthful vision after lens surgery in terms of focusing ability, accurate optical power, and sharp focus without distortion or optical aberrations.
This thesis presents an approach to restoring youthful vision after lens replacement. An intraocular lens (IOL) that can provide accurate visual acuity along with focusing ability is proposed. This IOL relies on the natural anatomy and physiology of the eye, and therefore is actuated in a manner identical to the natural lens. In addition, the lens has the capability for adjustment during or after implantation to provide high-acuity vision throughout life.
The natural anatomy and physiology of the eye is described, along with lens replacement surgery. A lens design is proposed to address the unmet need of lens-replacement patients. Specific care in the design is made for small surgical incisions, high visual acuity, adjustable acuity over years, and the ability to focus similar to the natural lens. Methods to test the IOL using human donor tissue are developed based upon prior experiments on the ex vivo natural lens. These tools are used to demonstrate efficacy of the newly developed accommodating intraocular lens.
To further demonstrate implant feasibility, materials and processes for building the lens are evaluated for biocompatibility, endurance, repeatable manufacture, and stability. The lens biomechanics are determined after developing an artificial anatomy testing setup inspired by the natural anatomy of the human focusing mechanism. Finally, based upon a mechanical and optical knowledge of the lens, several improved lens concepts are proposed and demonstrated for efficacy.
Resumo:
Purpose: the aim of this pilot study was to test whether retinitis pigmentosa patients would benefit from filter contact lenses as an effective optical aid against glare and photophobia. Methods: fifteen subjects with retinitis pigmentosa were enrolled in this study. All of them were evaluated with filter soft contact lenses (MaxSight), filter glasses (CPF 527) and without filters (control). All patients were assessed for the three aid conditions by means of best corrected visual acuity (BCVA), contrast sensitivity (without glare and with central and peripheral glare)(CSV-1000) and a specific subjective questionnaire about quality of vision. Results: BCVA was slightly better with filters than without filter but the differences were not statistically significant. Contrast sensitivity without glare improved significantly with the contact lenses (p<0.05). The central glare had significant differences for the frequencies of 3 cpd and 18 cpd between the contact lens filter and the control group (p=0.021 and p=0.044, respectively). For the peripheral glare contrast sensitivity improved with contact lens versus control group for highest frequencies, 12 and 18 cpd (p<0.001 and p=0.045, respectively). According to the questionnaire the contact lens filter gave them more visual comfort than the glasses filter under the scenarios of indoors glare, outdoors activities and indoors comfort. Conclusion: the filter contact lenses seem to be a good option to improve the quality of vision of patients with retinitis pigmentosa.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
El presente estudio tuvo como objetivo determinar las características epidemiológicas del desprendimiento regmatógeno de retina en la población atendida en la Clínica Oftalmológica Oftalmolaser en el periodo 2013 - 2015. Se realizó un estudio cuantitativo descriptivo basado en la revisión y análisis del registro de historias clínicas, obteniendo los siguientes resultados: la frecuencia del desprendimiento regmatógeno de retina fue mayor en el sexo masculino con 54%; el mayor numero de casos se presento en la sexta década de la vida con 30%, la edad promedio de la población en estudio fue 55 años, los antecedentes patológicos mas frecuentes fueron miopía y pseudofaquia con un 27,4% para cada uno, el 51,08% de la población no presentó ningún antecedente quirúrgico oftalmológico, el 36,02% refirió haber tenido cirugía de catarata, el 63,40% de pacientes presentaron alteración de la agudeza visual como manifestación sintomática mientras que defectos del campo visual se presentaron en un 20,85%, el ojo derecho fue el mas afectado con 56%, el 56% de los pacientes acudieron luego de cuatro semanas del inicio de la sintomatología, el 82,78% presentaron agudeza visual de 20/400 al momento del examen físico y el 56,11% presentaron PIO normal mientras que el 40% presento hipotonía ocular. La localización más frecuente fue la temporal superior con un 30,56% y el 71% presentaron afección de la mácula evidenciada en la retinoscopía
Resumo:
Aim: To investigate the qualitative aspects in patient selection and the quantitative impact of disease burden in real world treatment of vitreomacular traction (VMT) and implementation of the National Institute for Health and Care Excellence (NICE) guidance (TA297). Methods: A monocentric, retrospective review of consecutive patients undergoing optical coherence tomography (OCT) imaging over a 3 month period. Patients with VMT in at least one eye were identified for further data collection on laterality, visual acuity, symptoms, presence of epiretinal membrane, macular hole and treatment selection. Results: A total of 3472 patients underwent OCT imaging with a total of 6878 eyes scanned. Out of 87 patients, 74 patients had unilateral VMT (38 right, 36 left) and 13 patients had bilateral VMT. Eighteen patients with unilateral VMT satisfied NICE criteria of severe sight problems in the affected eye. Eight were managed for a coexisting pathology, one refused treatment, one patient did not attend, two closed spontaneously, and one received ocriplasmin prior to the study start date. Only two patients with unilateral VMT received ocriplasmin and three underwent vitrectomy. Those failing to meet NICE criteria for unilateral VMT were predominantly asymptomatic (n=49) or had coexisting ERM (n=5) or both (n=2). Conclusion: Ocriplasmin provides an alternative treatment for patients with symptomatic VMT. Our data shows that the majority of patients with VMT do not meet NICE TA297 primarily due to lack of symptoms. Those meeting NICE criteria, but not treated, tended to have coexisting macular pathology. Variation in patient selection due to subjective factors not outlined in NICE guidance suggests that real world outcomes of ocriplasmin therapy should be interpreted with caution.
Resumo:
To develop a disease activity index for patients with uveitis (UVEDAI) encompassing the relevant domains of disease activity considered important among experts in this field. The steps for designing UVEDAI were: (a) Defining the construct and establishing the domains through a formal judgment of experts, (b) A two-round Delphi study with a panel of 15 experts to determine the relevant items, (c) Selection of items: A logistic regression model was developed that set ocular inflammatory activity as the dependent variable. The construct “uveitis inflammatory activity” was defined as any intraocular inflammation that included external structures (cornea) in addition to uvea. Seven domains and 15 items were identified: best-corrected visual acuity, inflammation of the anterior chamber (anterior chamber cells, hypopyon, the presence of fibrin, active posterior keratic precipitates and iris nodules), intraocular pressure, inflammation of the vitreous cavity (vitreous haze, snowballs and snowbanks), central macular edema, inflammation of the posterior pole (the presence and number of choroidal/retinal lesions, vascular inflammation and papillitis), and global assessment from both (patient and physician). From all the variables studied in the multivariate model, anterior chamber cell grade, vitreous haze, central macular edema, inflammatory vessel sheathing, papillitis, choroidal/retinal lesions and patient evaluation were included in UVEDAI. UVEDAI is an index designed to assess the global ocular inflammatory activity in patients with uveitis. It might prove worthwhile to motorize the activity of this extraarticular manifestation of some rheumatic diseases.
Resumo:
Underwater video transect methods using small remotely operated vehicles (ROVs) and diveroperated video (DOV) are commonly used in benthic biodiversity assessments. Constraints posed by deeper waters have made surveys of the circalittoral zone ([30 m depth), a particularly challenging problem. Here we compare benthic diversity metrics and cluster analyses obtained with ROV and DOV between 45 and 65 m depth off southwest Iberia, across local (tens to hundreds of meters) and regional scales (tens of kilometers). Results showed no difference between methods in terms of the benthic species richness, taxonomic distinctness, and beta diversity, but only minor differences in the spatial structure depicted at the regional level. At the local scale, DOV performed better at discriminating patterns likely because of the divers visual acuity. We found that small ROV and DOV are reliable and comparable methods for the study of circalittoral benthic assemblages and can be used in a complimentary way to detect the greatest amount of variation in benthic ecosystems. Our study facilitates the understanding of capabilities and limitations of two underwater video methods and provides important insight into choice of the most appropriate technique.
Resumo:
RESUMEN Objetivo: Estimar la prevalencia de las diferentes enfermedades oftalmológicas que aparecen en el contexto de una enfermedad autoinmune (EAI) en pacientes de un centro de referencia reumatológica en Colombia, según características clínicas y sociodemográficas durante un período de 15 años, comprendido entre los años 2000 a 2015. Métodos: Se realizó un estudio descriptivo, observacional de prevalencia. El tipo de muestreo fue aleatorio estratificado con asignación proporcional en el programa Epidat 3.4. Los datos se analizaron en el programa SPSS v22.0 y se realizó análisis univariado de las variables categóricas, para las variables cuantitativas se realizaron medidas de tendencia central. Resultados: De 1640 historias clínicas revisadas, se encontraron 634 pacientes (38,65%) con compromiso ocular. Si excluimos los pacientes con SS, que por definición presentan ojo seco, 222 pacientes (13,53%) presentaron compromiso oftalmológico. Del total de pacientes, el 83,3% fueron mujeres. La AR fue la enfermedad autoinmune con mayor compromiso oftalmológico con 138 pacientes (62,2%), y en último lugar la sarcoidosis con 1 solo paciente afectado. La QCS fue la manifestación más común en todos los grupos diagnósticos de EAI, con 146 pacientes (63,5%). De 414 pacientes con Síndrome de Sjögren (SS) y QCS 8 presentaron compromiso ocular adicional, siendo la uveítis la segunda patología ocular asociada en pacientes con SS y la primera causa en las espondiloartropatias (71,4 %). Los pacientes con catarata (4,1%) presentaron la mayor prevalencia de uso de corticoide (88.8%). De 222 pacientes, 28 (12,6%) presentaron uveítis. Del total de pacientes, 16 (7,2%) presentaron maculopatía por antimalaráricos y 6 (18,75%) de los pacientes con LES. Los ANAS se presentaron en el 100% los pacientes con trastorno vascular de la retina. Los pacientes con epiescleritis presentaron la mayor proporción de positivización de anticuerpos anti-DNA. La EAI que más presentó epiescleritis fue LES con 4 pacientes (12,5%) El 22% de paciente con anticuerpos anti-RNP presentaron escleritis y 32,1% de los pacientes con uveítis presentaron HLA-B27 positivo. Las manifestaciones oftalmológicas precedieron a las sistémicas entre un 11,1% y un 33,3% de los pacientes. Conclusión: Las enfermedades oculares se presentan con frecuencia en los pacientes colombianos con EAI (38.65%), siendo la AR la enfermedad con mayor compromiso ocular (62,2%) y la QCS la enfermedad ocular con mayor prevalencia en todas las EAI (63,5%). La uveítis se presentó en 28 pacientes (12,6%). Las manifestaciones oftalmológicas pueden preceder a las sistémicas. El examen oftalmológico debe ser incluido en los pacientes con EAI, por ser la enfermedad ocular una comorbilidad frecuente. Adicionalmente, los efectos oftalmológicos de las medicaciones sistémicas utilizadas en EAI deben ser estrechamente monitorizados, durante el curso del tratamiento.
Resumo:
Visual sea-floor mapping is a rapidly growing application for Autonomous Underwater Vehicles (AUVs). AUVs are well-suited to the task as they remove humans from a potentially dangerous environment, can reach depths human divers cannot, and are capable of long-term operation in adverse conditions. The output of sea-floor maps generated by AUVs has a number of applications in scientific monitoring: from classifying coral in high biological value sites to surveying sea sponges to evaluate marine environment health.
Resumo:
In most visual mapping applications suited to Autonomous Underwater Vehicles (AUVs), stereo visual odometry (VO) is rarely utilised as a pose estimator as imagery is typically of very low framerate due to energy conservation and data storage requirements. This adversely affects the robustness of a vision-based pose estimator and its ability to generate a smooth trajectory. This paper presents a novel VO pipeline for low-overlap imagery from an AUV that utilises constrained motion and integrates magnetometer data in a bi-objective bundle adjustment stage to achieve low-drift pose estimates over large trajectories. We analyse the performance of a standard stereo VO algorithm and compare the results to the modified vo algorithm. Results are demonstrated in a virtual environment in addition to low-overlap imagery gathered from an AUV. The modified VO algorithm shows significantly improved pose accuracy and performance over trajectories of more than 300m. In addition, dense 3D meshes generated from the visual odometry pipeline are presented as a qualitative output of the solution.