984 resultados para Numerical-solution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Calcium is one of the triggers involved in ischemic neuronal death. Because hypotension is a strong predictor of outcome in traumatic brain injury (TBI), we tested the hypothesis that early fluid resuscitation blunts calcium influx in hemorrhagic shock associated to TBI. Methods: Fifteen ketamine-halothane anesthetized mongrel dogs (18.7 kg +/- 1.4 kg) underwent unilateral cryogenic brain injury. Blood was shed in 5 minutes to a target mean arterial pressure of 40 mm Hg to 45 mm Hg and maintained at these levels for 20 minutes (shed blood volume = 26 mL/kg +/- 7 mL/kg). Animals were then randomized into three groups: CT (controls, no fluid resuscitation), HS (7.5% NaCl, 4 mL/kg, in 5 minutes), and LR (lactate Ringer`s, 33 mL/kg, in 15 minutes). Twenty minutes later, a craniotomy was performed and cerebral biopsies were obtained next to the lesion (""clinical penumbra"") and from the corresponding contralateral side (""lesion`s mirror"") to determine intracellular calcium by fluorescence signals of Fura-2-loaded cells. Results: Controls remained hypotensive and in a low-flow state, whereas fluid resuscitation improved hemodynamic profile. There was a significant increase in intracellular calcium in the injured hemisphere in CT (1035 nM +/- 782 nM), compared with both HS (457 nM +/- 149 nM, p = 0.028) and LR (392 nM +/- 178 nM, p = 0.017), with no differences between HS and LR (p = 0.38). Intracellular calcium at the contralateral, uninjured hemisphere was 438 nM +/- 192 nM in CT, 510 nM +/- 196 nM in HS, and 311 nM +/- 51 nM in LR, with no significant differences between them. Conclusion: Both small volume hypertonic saline and large volume lactated Ringer`s blunts calcium influx in early stages of TBI associated to hemorrhagic shock. No fluid resuscitation strategy promotes calcium influx and further neural damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field studies have shown that the elevation of the beach groundwater table varies with the tide and such variations affect significantly beach erosion or accretion. In this paper, we present a BEM (Boundary Element Method) model for simulating the tidal fluctuation of the beach groundwater table. The model solves the two-dimensional flow equation subject to free and moving boundary conditions, including the seepage dynamics at the beach face. The simulated seepage faces were found to agree with the predictions of a simple model (Turner, 1993). The advantage of the present model is, however, that it can be used with little modification to simulate more complicated cases, e.g., surface recharge from rainfall and drainage in the aquifer may be included (the latter is related to beach dewatering technique). The model also simulated well the field data of Nielsen (1990). In particular, the model replicated three distinct features of local water table fluctuations: steep rising phase versus flat falling phase, amplitude attenuation and phase lagging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-pressure homogenization is a key unit operation used to disrupt cells containing intracellular bioproducts. Modeling and optimization of this unit are restrained by a lack of information on the flow conditions within a homogenizer value. A numerical investigation of the impinging radial jet within a homogenizer value is presented. Results for a laminar and turbulent (k-epsilon turbulent model) jet are obtained using the PHOENICS finite-volume code. Experimental measurement of the stagnation region width and correlation of the cell disruption efficiency with jet stagnation pressure both indicate that the impinging jet in the homogenizer system examined is likely to be laminar under normal operating conditions. Correlation of disruption data with laminar stagnation pressure provides a better description of experimental variability than existing correlations using total pressure drop or the grouping 1/Y(2)h(2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is presented for computing the fields produced by radio frequency probes of the type used in magnetic resonance imaging. The effects of surrounding the probe with a shielding coil, intended to eliminate stray fields produced outside the probe, are included. An essential feature of these devices is the fact that the conducting rungs of the probe are of finite width relative to the coil radius, and it is therefore necessary to find the distribution of current within the conductors as part of the solution process. This is done here using a numerical method based on the inverse finite Hilbert transform, applied iteratively to the entire structure including its shielding coils. It is observed that the fields are influenced substantially by the width of the conducting rungs of the probe, since induced eddy currents within the rungs become more pronounced as their width is increased. The shield is also shown to have a significant effect on both the primary current density and the resultant fields. Quality factors are computed for these probes and compared with values measured experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The venoms of Conus snails contain small, disulfide-rich inhibitors of voltage-dependent sodium channels. Conotoxin GS is a 34-residue polypeptide isolated from Conus geographus that interacts with the extracellular entrance of skeletal muscle sodium channels to prevent sodium ion conduction. Although conotoxin GS binds competitively with mu conotoxin GIIIA to the sodium channel surface, the two toxin types have little sequence identity with one another, and conotoxin GS has a four-loop structural framework rather than the characteristic three-loop mu-conotoxin framework. The structural study of conotoxin GS will form the basis for establishing a structure-activity relationship and understanding its interaction with the pore region of sodium channels. Results: The three-dimensional structure of conotoxin GS was determined using two-dimensional NMR spectroscopy. The protein exhibits a compact fold incorporating a beta hairpin and several turns. An unusual feature of conotoxin GS is the exceptionally high proportion (100%) of cis-imide bond geometry for the three proline or hydroxyproline residues. The structure of conotoxin GS bears little resemblance to the three-loop mu conotoxins, consistent with the low sequence identity between the two toxin types and their different structural framework. However, the tertiary structure and cystine-knot motif formed by the three disulfide bonds is similar to that present in several other polypeptide ion channel inhibitors. Conclusions: This is the first three-dimensional structure of a 'four-loop' sodium channel inhibitor, and it represents a valuable new structural probe for the pore region of voltage-dependent sodium channels. The distribution of amino acid sidechains in the structure creates several polar and charged patches, and comparison with the mu conotoxins provides a basis for determining the binding surface of the conotoxin GS polypeptide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-frequency beach water table fluctuations due to wave run-up and rundown have been observed in the field [Waddell, 1976]. Such fluctuations affect the infiltration/exfiltration process across the beach face and the interstitial oxygenation process in the beach ecosystem. Accurate representation of high-frequency water table fluctuations is of importance in the modeling of (1) the interaction between seawater and groundwater, more important, the effects on swash sediment transport and (2) the biological activities in the beach ecosystem. Capillarity effects provide a mechanism for high-frequency water table fluctuations. Previous modeling approaches adopted the assumption of saturated flow only and failed to predict the propagation of high-frequency fluctuations in the aquifer. In this paper we develop a modified kinematic boundary condition (kbc) for the water table which incorporates capillarity effects. The application of this kbc in a boundary element model enables the simulation of high-frequency water table fluctuations due to wave run-up. Numerical tests were carried out for a rectangular domain with small-amplitude oscillations; the behavior of water table responses was found to be similar to that predicted by an analytical solution based on the one-dimensional Boussinesq equation. The model was also applied to simulate the water table response to wave run-up on a doping beach. The results showed similar features of water table fluctuations observed in the field. In particular, these fluctuations are standing wave-like with the amplitude becoming increasingly damped inland. We conclude that the modified kbc presented here is a reasonable approximation of capillarity effects on beach water table fluctuations. However, further model validation is necessary before the model can confidently be used to simulate high-frequency water table fluctuations due to wave run-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Lung tranplantation, a consolidated treatment for end-stage lung disease, utilizes preservation solutions, such as low potassium dextran (LPD), to mitigate ischemia reperfusion injury. We sought the local development of LPD solutions in an attempt to facilitate access and enhance usage. We also sought to evaluate the effectiveness of a locally manufactured LPD solution in a rat model of ex vivo lung perfusion. Methods. We randomized the following groups \?\adult of male Wistar rats (n = 25 each): Perfadex (LPD; Vitro life, Sweden); locally manufactured LPD-glucose (LPDnac) (Farmoterapica, Brazil), and normal saline solution (SAL) with 3 ischemic times (6, 12, and 24 hours). The harvested heart lung blocks were flushed with solution at 4 C. After storage, the blocks were connected to an IL-2 Isolated Perfused Rat or Guinea Pig Lung System (Harvard Apparatus) and reperfused with homologous blood for 60 minutes. Respiratory mechanics, pulmonary artery pressure, perfusate blood gas analysis, and lung weight were measured at 10-minute intervals. Comparisons between groups and among ischemic times were performed using analysis of variance with a 5% level of significance. Results. Lungs preserved for 24 hours were nonviable and therefore excluded from the analysis. Those preserved for 6 hours showed better ventilatory mechanics when compared with 12 hours. The oxygenation capacity was not different between lungs flushed with LPD or LPDnac, regardless of the ischemic time. SAL lungs showed higher PCO(2) values than the other solutions. Lung weight increased over time during perfusion; however, there were no significant differences among the tested solutions (LPD, P = .23; LPDnac, P = .41; SAL, P = .26). We concluded that the LPDnac solution results in gas exchange were comparable to the original LPD (Perfadex); however ventilatory mechanics and edema formation were better with LPD, particularly among lungs undergoing 6 hours of cold ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recently, studies have been conducted examining the efficacy of 3% hypertonic saline solution (HS) for the treatment of traumatic brain injury; however, few studies have analyzed the effects of 3% hemorrhagic shock during hemorrhagic shock. The aim of this study was to test the potential immunomodulatory benefits of 3% hemorrhagic shock resuscitation over standard fluid resuscitation. METHODS: Wistar rats were bled to a mean arterial pressure of 35 mm Hg and then randomized into 3 groups: those treated with lactated Ringer`s solution (LR; 33 mL/kg, n = 7), 3% HS (10 mL/kg, n = 7), and 7.5% HS (4 mL/kg, n = 7). Half of the extracted blood was reinfused after fluid resuscitation. Animals that did not undergo shock served as controls (n = 5). Four hours after hemorrhagic shock, blood was collected for the evaluation of tumor necrosis factor-a and interleukin-6 by enzyme immunoassay. Lung and intestinal samples were obtained for histopathologic analysis. RESULTS: Animals in the HS groups had significantly higher mean arterial pressure than those in the LR group 1 hour after treatment. Osmolarity and sodium levels were markedly elevated in the HS groups. Tumor necrosis factor-alpha and interleukin-6 levels were similar between the control and HS groups but significantly higher in the LR group (P < .05). The lung injury score was significantly higher in the LR group compared with the 7.5% HS and 3% HS groups (5.7 +/- 0.7, 2.1 +/- 0.4, and 2.7 +/- 0.5, respectively). Intestinal injury was attenuated in the 7.5% HS and 3% HS groups compared with the LR group (2.0 +/- 0.6, 2.3 +/- 0.4, and 5.9 +/- 0.6, respectively). CONCLUSIONS: A small-volume resuscitation strategy modulates the inflammatory response and decreases end-organ damage after HS. Three percent HS provides immunomodulatory and metabolic effects similar to those observed with conventional concentrations of HS. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermally induced optical nonlinearity in a chlorophyll ethanol solution is examined. A theory is presented which shows good agreement with experiment. The theory models an optically thick but physically thin medium whose only heat transport mechanism is conduction. An average nz was found for the medium which corresponds well with previous results but the thermal medium is shown to be fundamentally different from a Kerr medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider solutions to the second-harmonic generation equations in two-and three-dimensional dispersive media in the form of solitons localized in space and time. As is known, collapse does not take place in these models, which is why the solitons may be stable. The general solution is obtained in an approximate analytical form by means of a variational approach, which also allows the stability of the solutions to be predicted. Then, we directly simulate the two-dimensional case, taking the initial configuration as suggested by the variational approximation. We thus demonstrate that spatiotemporal solitons indeed exist and are stable. Furthermore, they are not, in the general case, equivalent to the previously known cylindrical spatial solitons. Direct simulations generate solitons with some internal oscillations. However, these oscillations neither grow nor do they exhibit any significant radiative damping. Numerical solutions of the stationary version of the equations produce the same solitons in their unperturbed form, i.e., without internal oscillations. Strictly stable solitons exist only if the system has anomalous dispersion at both the fundamental harmonic and second harmonic (SH), including the case of zero dispersion at SH. Quasistationary solitons, decaying extremely slowly into radiation, are found in the presence of weak normal dispersion at the second-harmonic frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Diving liver ischemia, the decrease in mitochondrial energy causes cellular damage that is aggravated after reperfusion. This injury can trigger a systemic inflammatory syndrome, also producing remote organ damage. Several substances have been employed to decrease this inflammatory response during liver transplantation, liver resections, and hypovolemic shock. The aim of this study was to evaluate the effects of hypertonic saline solution and the best timing of administration to prevent organ injury during experimental liver ischemia/reperfusion. Methods. Rats underwent 1 hr of warm liver ischemia followed by reperfusion. Eighty-four rats Were allocated into 6 groups: sham group, control of ischemia group) (C), pre-ischemia treated NaCl 0.9% (ISS) and NaCl 7.5% (HTS) groups, pre-repefusion ISS, and HTS groups. Blood and tissue samples were collected 4 hr after reperfusion. Results. HTS showed beneficial effects in prevention of live ischemia/reperfusion injury. HTS groups developed increases in AST and ALT levels that were significantly less than ISS groups; however, the HTS pre-reperfusion group showed levels significantly less than the HTS pre-ischemia group. No differences in IL-6 and IL-10 levels, were observed. A significant decrease in mitochondrial dysfunction as well as hepatic edema was observed in the HTS pre-reperfusion group. Pulmonary vascular permeability Was significantly less in the pre-reperfusion HTS group compared to the ISS group. No differences in myeloperoxidase activity were observed. The liver histologic score was significantly less in the pre-reperfusion HTS group compared to the pre-ischemia I-ITS group. Conclusion. HTS ameliorated local and systemic injuries in experimental liver ischemia/reperfusion. Infusion of HTS in the pre-reperfusion period may be an important adjunct to accomplish the best results. (Surgery 2010;147:415-23.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photodegradation of irinotecan (CPT-11), the semisynthetic derivative of the antitumor alkaloid 20(S)-camptothecin, has been investigated. The drug was exposed to laboratory light for up to 5 days in 0.9% saline solution (pH 8.5). Five significant photodegradation products were observed and a high-performance liquid chromatography (HPLC) assay was employed to isolate them from CPT-11 using gradient conditions. The structures were elucidated by nuclear magnetic resonance spectroscopy and tandem mass spectrometry and shown to be the result of extensive modifications of the lactone ring of CPT-11. Three of the compounds were found to belong to the mappicine group of alkaloids. In addition, the effect of light on the stability of CPT-11 in aqueous solutions and biological fluids was also assessed, Potassium phosphate buffers (0.05 M, pH 5.0-8.2) and saline, plasma, urine, and bile solutions containing 20 mu M CPT-11 were equilibrated in the dark for 24 h before being exposed to laboratory light for up to 171 h at ambient temperature. Four of the five identified photodegradation products were observed and quantitated by isocratic HPLC, using a different detection mode (fluorescence) than the one used for gradient elution, In general, CPT-11 was found to be unstable under neutral and alkaline conditions for all solutions investigated, with the exception of bile. We conclude that CPT-11 is photolabile and that care should be taken to protect samples, particularly those intended for the isolation and identification of novel metabolites of CPT-11.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

objective. To describe the management of patients with long-term central venous catheters (CVCs) during an outbreak of infection due to Pseudomonas putida and Stenotrophomonas maltophilia associated with contaminated heparin catheter-lock solution. design. Descriptive study. setting. Private, 250-bed tertiary-care hospital. methods. In March 2003, we identified 2 febrile cancer patients with P. putida bacteremia. Over 2 days, 7 cases of bacteremia were identified; lots of syringes prefilled with heparin catheter-lock solution, supplied by a compounding pharmacy, were recalled and samples were cultured. More cases of bacteremia appeared during the following days, and any patient who had had a catheter lock infused with the suspect solution was asked to provide blood samples for culture, even if the patient was asymptomatic. Isolates that were recovered from culture were typed by pulsed-field gel electrophoresis. Antimicrobial salvage treatment of long-term CVCs was attempted. results. A total of 154 patients had had their catheter lock infused with solution from the lots that were suspected of being contaminated. Only 48 of these patients had CVCs. By day 7 of the outbreak, 18 of these patients had become symptomatic. Twenty-six of the remaining 30 asymptomatic patients then also provided blood samples for culture, 10 of whom developed fever shortly after samples were collected. Thirty-two patients were identified who had P. putida bacteremia; 9 also had infection due to S. maltophilia. Samples from 1 of the 3 lots of prefilled syringes in use at the time of the outbreak also grew P. putida on culture. Molecular typing identified 3 different clones of P. putida from patients and heparin catheter-lock solution, and 1 clone of S. maltophilia. A total of 27 patients received antimicrobial therapy regimens, some of which included decontamination of the catheter lock with anti- infective lock solution. Of 27 patients, 19 (70%) retained their long-term CVC during the 6-month follow-up period. conclusions. To our knowledge, this is one of the largest prospective experiences in the management of bloodstream infection associated with long-term CVCs. The infections were caused by gram-negative bacilli and were managed without catheter removal, with a high response rate. We emphasize the risks of using intravenous formulations of medications supplied by compounding pharmacies that produce large quantities of drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To describe the use of pulsed fluoroscopic guidance, to perform endoscopic procedures in pregnant women, by inverting the fluoroscope`s c-arm using a lead thyroid collar to shield the fetus from the direct X-ray beam. The use of radiation during treatment of pregnant patients with urolithiasis remains a recurring dilemma. METHODS Between May 2006 and December 2008, endoscopic treatment due to ureteral stones was attempted in 8 pregnant women. In all cases, we use an inverted fluoroscope`s c-arm during endoscopic treatment associated with 2 lead neck thyroid collars to shield the uterus, protecting the fetus from direct radiation. Indication for treatment was symptomatic ureteral stones unresponsive to medical treatment in 7 and persistent fever in 1. RESULTS Mean ureteral stone size was 8.1 +/- 4.8 mm, located in the left ureter in 5 (62.5%) cases. Three (37.5%) patients had stone located in the upper ureter, 2 (25%) in the middle ureter, and 3 (37.5) in the distal ureter. In 6 cases, ureteral stones were treated using the semi-rigid ureteroscope, whereas in 1 case a flexible ureteroscope was needed. One woman was treated with insertion of a double-J stent due to associated urinary infection. No women has early delivery related to the endoscopic procedure, and all neonates were perfectly normal. CONCLUSIONS We present a technique for endoscopic procedures in pregnant women inverting the fluoroscope`s c-arm and protecting the fetus from the direct X-ray beam. This practical approach should be specially considered when no portable ultrasound and radiologic assistance in available in the operating room. UROLOGY 75: 1505-1508, 2010. (c) 2010 Published by Elsevier Inc.