946 resultados para Non invasive methods
Resumo:
The need to provide computers with the ability to distinguish the affective state of their users is a major requirement for the practical implementation of affective computing concepts. This dissertation proposes the application of signal processing methods on physiological signals to extract from them features that can be processed by learning pattern recognition systems to provide cues about a person's affective state. In particular, combining physiological information sensed from a user's left hand in a non-invasive way with the pupil diameter information from an eye-tracking system may provide a computer with an awareness of its user's affective responses in the course of human-computer interactions. In this study an integrated hardware-software setup was developed to achieve automatic assessment of the affective status of a computer user. A computer-based "Paced Stroop Test" was designed as a stimulus to elicit emotional stress in the subject during the experiment. Four signals: the Galvanic Skin Response (GSR), the Blood Volume Pulse (BVP), the Skin Temperature (ST) and the Pupil Diameter (PD), were monitored and analyzed to differentiate affective states in the user. Several signal processing techniques were applied on the collected signals to extract their most relevant features. These features were analyzed with learning classification systems, to accomplish the affective state identification. Three learning algorithms: Naïve Bayes, Decision Tree and Support Vector Machine were applied to this identification process and their levels of classification accuracy were compared. The results achieved indicate that the physiological signals monitored do, in fact, have a strong correlation with the changes in the emotional states of the experimental subjects. These results also revealed that the inclusion of pupil diameter information significantly improved the performance of the emotion recognition system. ^
Resumo:
Establishing an association between the scent a perpetrator left at a crime scene to the odor of the suspect of that crime is the basis for the use of human scent identification evidence in a court of law. Law enforcement agencies gather evidence through the collection of scent from the objects that a perpetrator may have handled during the execution of the criminal act. The collected scent evidence is consequently presented to the canines for identification line-up procedures with the apprehended suspects. Presently, canine scent identification is admitted as expert witness testimony, however, the accurate behavior of the dogs and the scent collection methods used are often challenged by the court system. The primary focus of this research project entailed an evaluation of contact and non-contact scent collection techniques with an emphasis on the optimization of collection materials of different fiber chemistries to evaluate the chemical odor profiles obtained using varying environment conditions to provide a better scientific understanding of human scent as a discriminative tool in the identification of suspects. The collection of hand odor from female and male subjects through both contact and non-contact sampling approaches yielded new insights into the types of VOCs collected when different materials are utilized, which had never been instrumentally performed. Furthermore, the collected scent mass was shown to be obtained in the highest amounts for both gender hand odor samples on cotton sorbent materials. Compared to non-contact sampling, the contact sampling methods yielded a higher number of volatiles, an enhancement of up to 3 times, as well as a higher scent mass than non-contact methods by more than an order of magnitude. The evaluation of the STU-100 as a non-contact methodology highlighted strong instrumental drawbacks that need to be targeted for enhanced scientific validation of current field practices. These results demonstrated that an individual's human scent components vary considerably depending on the method used to collect scent from the same body region. This study demonstrated the importance of collection medium selection as well as the collection method employed in providing a reproducible human scent sample that can be used to differentiate individuals.
Resumo:
Transects of a Remotely Operated Vehicle (ROV) providing sea-bed videos and photographs were carried out during POLARSTERN expedition ANT-XIII/3 focussing on the ecology of benthic assemblages on the Antarctic shelf in the South-Eastern Weddell Sea. The ROV-system sprint 103 was equiped with two video- and one still camera, lights, flash-lights, compass, and parallel lasers providing a scale in the images, a tether-management system (TMS), a winch, and the board units. All cameras used the same main lense and could be tilted. Videos were recorded in Betacam-format and (film-)slides were made by decision of the scientific pilot. The latter were mainly made under the aspect to improve the identification of organisms depicted in the videos because the still photographs have a much higher optical resolution than the videos. In the photographs species larger than 3 mm, in the videos larger than 1 cm are recognisable and countable. Under optimum conditions the transects were strait; the speed and direction of the ROV were determined by the drift of the ship in the coastal current, since both, the ship and the ROV were used as a drifting system; the option to operate the vehicle actively was only used to avoide obstacles and to reach at best a distance of only approximately 30 cm to the sea-floor. As a consequence the width of the photographs in the foreground is approximately 50 cm. Deviations from this strategy resulted mainly from difficult ice- and weather conditions but also from high current velocity and local up-welling close to the sea-bed. The sea-bed images provide insights into the general composition of key species, higher systematic groups and ecological guilds. Within interdisciplinary approaches distributions of assemblages can be attributed to environmental conditions such as bathymetry, sediment characteristics, water masses and current regimes. The images also contain valuable information on how benthic species are associated to each other. Along the transects, small- to intermediate-scaled disturbances, e.g. by grounding icebergs were analysed and further impact to the entire benthic system by local succession of recolonisation was studied. This information can be used for models predicting the impact of climate change to benthic life in the Southern Ocean. All these approaches contribute to a better understanding of the fiunctioning of the benthic system and related components of the entire Antarctic marine ecosystem. Despite their scientific value the imaging methods meet concerns about the protection of sensitive Antarctic benthic systems since they are non-invasive and they also provide valuable material for education and outreach purposes.
Resumo:
Transects of a Remotely Operated Vehicle (ROV) providing sea-bed videos and photographs were carried out during POLARSTERN expedition ANT-XVII/3 focussing on the ecology of benthic assemblages on the Antarctic shelf in the South-Eastern Weddell Sea. The ROV-system sprint 103 was equiped with two video- and one still camera, lights, flash-lights, compass, and parallel lasers providing a scale in the images, a tether-management system (TMS), a winch, and the board units. All cameras used the same main lense and could be tilted. Videos were recorded in Betacam-format and (film-)slides were made by decision of the scientific pilot. The latter were mainly made under the aspect to improve the identification of organisms depicted in the videos because the still photographs have a much higher optical resolution than the videos. In the photographs species larger than 3 mm, in the videos larger than 1 cm are recognisable and countable. Under optimum conditions the transects were strait; the speed and direction of the ROV were determined by the drift of the ship in the coastal current, since both, the ship and the ROV were used as a drifting system; the option to operate the vehicle actively was only used to avoide obstacles and to reach at best a distance of only approximately 30 cm to the sea-floor. As a consequence the width of the photographs in the foreground is approximately 50 cm. Deviations from this strategy resulted mainly from difficult ice- and weather conditions but also from high current velocity and local up-welling close to the sea-bed. The sea-bed images provide insights into the general composition of key species, higher systematic groups and ecological guilds. Within interdisciplinary approaches distributions of assemblages can be attributed to environmental conditions such as bathymetry, sediment characteristics, water masses and current regimes. The images also contain valuable information on how benthic species are associated to each other. Along the transects, small- to intermediate-scaled disturbances, e.g. by grounding icebergs were analysed and further impact to the entire benthic system by local succession of recolonisation was studied. This information can be used for models predicting the impact of climate change to benthic life in the Southern Ocean. All these approaches contribute to a better understanding of the fiunctioning of the benthic system and related components of the entire Antarctic marine ecosystem. Despite their scientific value the imaging methods meet concerns about the protection of sensitive Antarctic benthic systems since they are non-invasive and they also provide valuable material for education and outreach purposes.
Resumo:
X-ray computed tomography (CT) is a non-invasive medical imaging technique that generates cross-sectional images by acquiring attenuation-based projection measurements at multiple angles. Since its first introduction in the 1970s, substantial technical improvements have led to the expanding use of CT in clinical examinations. CT has become an indispensable imaging modality for the diagnosis of a wide array of diseases in both pediatric and adult populations [1, 2]. Currently, approximately 272 million CT examinations are performed annually worldwide, with nearly 85 million of these in the United States alone [3]. Although this trend has decelerated in recent years, CT usage is still expected to increase mainly due to advanced technologies such as multi-energy [4], photon counting [5], and cone-beam CT [6].
Despite the significant clinical benefits, concerns have been raised regarding the population-based radiation dose associated with CT examinations [7]. From 1980 to 2006, the effective dose from medical diagnostic procedures rose six-fold, with CT contributing to almost half of the total dose from medical exposure [8]. For each patient, the risk associated with a single CT examination is likely to be minimal. However, the relatively large population-based radiation level has led to enormous efforts among the community to manage and optimize the CT dose.
As promoted by the international campaigns Image Gently and Image Wisely, exposure to CT radiation should be appropriate and safe [9, 10]. It is thus a responsibility to optimize the amount of radiation dose for CT examinations. The key for dose optimization is to determine the minimum amount of radiation dose that achieves the targeted image quality [11]. Based on such principle, dose optimization would significantly benefit from effective metrics to characterize radiation dose and image quality for a CT exam. Moreover, if accurate predictions of the radiation dose and image quality were possible before the initiation of the exam, it would be feasible to personalize it by adjusting the scanning parameters to achieve a desired level of image quality. The purpose of this thesis is to design and validate models to quantify patient-specific radiation dose prospectively and task-based image quality. The dual aim of the study is to implement the theoretical models into clinical practice by developing an organ-based dose monitoring system and an image-based noise addition software for protocol optimization.
More specifically, Chapter 3 aims to develop an organ dose-prediction method for CT examinations of the body under constant tube current condition. The study effectively modeled the anatomical diversity and complexity using a large number of patient models with representative age, size, and gender distribution. The dependence of organ dose coefficients on patient size and scanner models was further evaluated. Distinct from prior work, these studies use the largest number of patient models to date with representative age, weight percentile, and body mass index (BMI) range.
With effective quantification of organ dose under constant tube current condition, Chapter 4 aims to extend the organ dose prediction system to tube current modulated (TCM) CT examinations. The prediction, applied to chest and abdominopelvic exams, was achieved by combining a convolution-based estimation technique that quantifies the radiation field, a TCM scheme that emulates modulation profiles from major CT vendors, and a library of computational phantoms with representative sizes, ages, and genders. The prospective quantification model is validated by comparing the predicted organ dose with the dose estimated based on Monte Carlo simulations with TCM function explicitly modeled.
Chapter 5 aims to implement the organ dose-estimation framework in clinical practice to develop an organ dose-monitoring program based on a commercial software (Dose Watch, GE Healthcare, Waukesha, WI). In the first phase of the study we focused on body CT examinations, and so the patient’s major body landmark information was extracted from the patient scout image in order to match clinical patients against a computational phantom in the library. The organ dose coefficients were estimated based on CT protocol and patient size as reported in Chapter 3. The exam CTDIvol, DLP, and TCM profiles were extracted and used to quantify the radiation field using the convolution technique proposed in Chapter 4.
With effective methods to predict and monitor organ dose, Chapters 6 aims to develop and validate improved measurement techniques for image quality assessment. Chapter 6 outlines the method that was developed to assess and predict quantum noise in clinical body CT images. Compared with previous phantom-based studies, this study accurately assessed the quantum noise in clinical images and further validated the correspondence between phantom-based measurements and the expected clinical image quality as a function of patient size and scanner attributes.
Chapter 7 aims to develop a practical strategy to generate hybrid CT images and assess the impact of dose reduction on diagnostic confidence for the diagnosis of acute pancreatitis. The general strategy is (1) to simulate synthetic CT images at multiple reduced-dose levels from clinical datasets using an image-based noise addition technique; (2) to develop quantitative and observer-based methods to validate the realism of simulated low-dose images; (3) to perform multi-reader observer studies on the low-dose image series to assess the impact of dose reduction on the diagnostic confidence for multiple diagnostic tasks; and (4) to determine the dose operating point for clinical CT examinations based on the minimum diagnostic performance to achieve protocol optimization.
Chapter 8 concludes the thesis with a summary of accomplished work and a discussion about future research.
Resumo:
Background: Individuals with chronic obstructive pulmonary disease (COPD) have higher than normal ventilatory equivalents for carbon dioxide (VE/VCO2) during exercise. There is growing evidence that emphysema on thoracic computed tomography (CT) scans is associated with poor exercise capacity in COPD patients with only mild-to-moderate airflow obstruction. We hypothesized that emphysema is an underlying cause of microvascular dysfunction and ventilatory inefficiency, which in turn contributes to reduced exercise capacity. We expected ventilatory inefficiency to be associated with a) the extent of emphysema; b) lower diffusing capacity for carbon monoxide; c) a reduced pulmonary blood flow response to exercise; and d) reduced exercise capacity. Methods: In a cross-sectional study, 19 subjects with mild-to-moderate COPD (mean ± SD FEV1= 82 ± 13% predicted, 12 GOLD grade 1) and 26 age-, sex-, and activity-matched controls underwent a ramp-incremental symptom-limited exercise test on a cycle ergometer. Ventilatory inefficiency was assessed by the minimum VE/VCO2 value (nadir). A subset of subjects also completed repeated constant work rate exercise bouts with non-invasive measurements of pulmonary blood flow. Emphysema was quantified as the percentage of attenuation areas below -950 Housefield Units on CT scans. An electronic scoresheet was used to keep track of emphysema sub-types. Results: COPD subjects typically had centrilobular emphysema (76.8 ± 10.1% of total emphysema) in the upper lobes (upper/lower lobe ratio= 0.82 ± 0.04). They had lower peak oxygen uptake (VO2), higher VE/VCO2 nadir and greater dyspnea scores than controls (p<0.05). Lower peak O2 and worse dyspnea were found in COPD subjects with VE/VCO2 nadirs ≥ 30. COPD subjects had blunted increases in pulmonary blood flow from rest to iso-VO2 exercise (p<0.05). Higher VE/VCO2 nadir in COPD subjects correlated with emphysema severity (r= 0.63), which in turn correlated with reduced lung diffusing capacity (r= -0.72) and blunted changes in pulmonary blood flow from rest to exercise (r= -0.69) (p<0.01). Conclusions: Ventilation “wasted” in emphysematous areas is associated with reduced exercise ventilatory efficiency in mild-to-moderate COPD. Exercise ventilatory inefficiency links structure (emphysema) and function (gas transfer) to a key clinical outcome (reduced exercise capacity) in COPD patients with modest spirometric abnormalities.
Resumo:
Amphibian defensive skin secretions and reptile venoms are rich sources of bioactive peptides with potential pharmacological/pharmaceutical applications. As amphibian and reptile populations are in rapid global decline, our research
group has been developing analytical methods that permit generation of robust molecular data from non-invasive skin secretion samples and venom samples. While previously we have demonstrated that parallel proteome and venom gland
transcriptome analyses can be performed on such samples, here we report the presence of DNA that facilitates the more widely-used applications of gene sequencing, such as molecular phylogenetics, in a non-invasive manner that circumvents specimen sacrifice. From this “surrogate” tissue, we acquired partial 12S and 16S rRNA gene sequences that are presented for illustration purposes. Thus from a single sample of amphibian skin secretion and reptile venom, robust and complementary proteome, transcriptome and genome data can be generated for applications in diverse scientific disciplines.
Resumo:
PURPOSE: Increased arterial stiffness is a common finding in patients with end-stage renal disease. Following creation of an arteriovenous fistula (AVF), appropriate dilation of the feeding artery must occur to facilitate AVF maturation. Arterial stiffness may impair the arterial dilation required to facilitate AVF development and contribute to subsequent failure to mature (FTM). The aim of this pilot study was to investigate the association between measurements of central and peripheral arterial stiffness, and AVF FTM.
METHODS: Patients undergoing AVF creation in a single centre (Belfast City Hospital, UK) between January and December 2015 were invited to have their carotid-femoral pulse wave velocity (PWV), brachial-radial PWV and augmentation index (AI) measured prior to AVF creation. Subsequent AVF outcomes were identified.
RESULTS: Fifty-nine patients who had an AVF procedure were included in the final analysis (mean age 62 years); 50.8% had diabetes mellitus. The mean pre-operative arterial diameter for all AVFs was 3.9 mm. Average values for carotid-femoral PWV were 9.5 m/s, brachial-radial PWV 7.7 m/s and AI 25.6%. Using logistic regression, these arterial stiffness parameters did not predict AVF FTM: carotid-femoral PWV (P = 0.20), brachial-radial PWV (P = 0.13), AI (P = 0.50).
CONCLUSIONS: This is the largest study to date exploring the association between arterial stiffness and AVF FTM. The measured central and peripheral arterial stiffness parameters were not associated with AVF FTM. Further research is needed to define if non-invasive arterial physiological measurements would be clinically useful in the prediction of AVF FTM.
Resumo:
Au cours des dernières décennies, l’effort sur les applications de capteurs infrarouges a largement progressé dans le monde. Mais, une certaine difficulté demeure, en ce qui concerne le fait que les objets ne sont pas assez clairs ou ne peuvent pas toujours être distingués facilement dans l’image obtenue pour la scène observée. L’amélioration de l’image infrarouge a joué un rôle important dans le développement de technologies de la vision infrarouge de l’ordinateur, le traitement de l’image et les essais non destructifs, etc. Cette thèse traite de la question des techniques d’amélioration de l’image infrarouge en deux aspects, y compris le traitement d’une seule image infrarouge dans le domaine hybride espacefréquence, et la fusion d’images infrarouges et visibles employant la technique du nonsubsampled Contourlet transformer (NSCT). La fusion d’images peut être considérée comme étant la poursuite de l’exploration du modèle d’amélioration de l’image unique infrarouge, alors qu’il combine les images infrarouges et visibles en une seule image pour représenter et améliorer toutes les informations utiles et les caractéristiques des images sources, car une seule image ne pouvait contenir tous les renseignements pertinents ou disponibles en raison de restrictions découlant de tout capteur unique de l’imagerie. Nous examinons et faisons une enquête concernant le développement de techniques d’amélioration d’images infrarouges, et ensuite nous nous consacrons à l’amélioration de l’image unique infrarouge, et nous proposons un schéma d’amélioration de domaine hybride avec une méthode d’évaluation floue de seuil amélioré, qui permet d’obtenir une qualité d’image supérieure et améliore la perception visuelle humaine. Les techniques de fusion d’images infrarouges et visibles sont établies à l’aide de la mise en oeuvre d’une mise en registre précise des images sources acquises par différents capteurs. L’algorithme SURF-RANSAC est appliqué pour la mise en registre tout au long des travaux de recherche, ce qui conduit à des images mises en registre de façon très précise et des bénéfices accrus pour le traitement de fusion. Pour les questions de fusion d’images infrarouges et visibles, une série d’approches avancées et efficaces sont proposés. Une méthode standard de fusion à base de NSCT multi-canal est présente comme référence pour les approches de fusion proposées suivantes. Une approche conjointe de fusion, impliquant l’Adaptive-Gaussian NSCT et la transformée en ondelettes (Wavelet Transform, WT) est propose, ce qui conduit à des résultats de fusion qui sont meilleurs que ceux obtenus avec les méthodes non-adaptatives générales. Une approche de fusion basée sur le NSCT employant la détection comprime (CS, compressed sensing) et de la variation totale (TV) à des coefficients d’échantillons clairsemés et effectuant la reconstruction de coefficients fusionnés de façon précise est proposée, qui obtient de bien meilleurs résultats de fusion par le biais d’une pré-amélioration de l’image infrarouge et en diminuant les informations redondantes des coefficients de fusion. Une procédure de fusion basée sur le NSCT utilisant une technique de détection rapide de rétrécissement itératif comprimé (fast iterative-shrinking compressed sensing, FISCS) est proposée pour compresser les coefficients décomposés et reconstruire les coefficients fusionnés dans le processus de fusion, qui conduit à de meilleurs résultats plus rapidement et d’une manière efficace.
Resumo:
Résumé : L'imagerie par résonance magnétique pondérée en diffusion est une modalité unique sensible aux mouvements microscopiques des molécules d'eau dans les tissus biologiques. Il est possible d'utiliser les caractéristiques de ce mouvement pour inférer la structure macroscopique des faisceaux de la matière blanche du cerveau. La technique, appelée tractographie, est devenue l'outil de choix pour étudier cette structure de façon non invasive. Par exemple, la tractographie est utilisée en planification neurochirurgicale et pour le suivi du développement de maladies neurodégénératives. Dans cette thèse, nous exposons certains des biais introduits lors de reconstructions par tractographie, et des méthodes sont proposées pour les réduire. D'abord, nous utilisons des connaissances anatomiques a priori pour orienter la reconstruction. Ainsi, nous montrons que l'information anatomique sur la nature des tissus permet d'estimer des faisceaux anatomiquement plausibles et de réduire les biais dans l'estimation de structures complexes de la matière blanche. Ensuite, nous utilisons des connaissances microstructurelles a priori dans la reconstruction, afin de permettre à la tractographie de suivre le mouvement des molécules d'eau non seulement le long des faisceaux, mais aussi dans des milieux microstructurels spécifiques. La tractographie peut ainsi distinguer différents faisceaux, réduire les erreurs de reconstruction et permettre l'étude de la microstructure le long de la matière blanche. Somme toute, nous montrons que l'utilisation de connaissances anatomiques et microstructurelles a priori, en tractographie, augmente l'exactitude des reconstructions de la matière blanche du cerveau.
Resumo:
Introduction Compounds exhibiting antioxidant activity have received much interest in the food industry because of their potential health benefits. Carotenoids such as lycopene, which in the human diet mainly derives from tomatoes (Solanum lycopersicum), have attracted much attention in this aspect and the study of their extraction, processing and storage procedures is of importance. Optical techniques potentially offer advantageous non-invasive and specific methods to monitor them. Objectives To obtain both fluorescence and Raman information to ascertain if ultrasound assisted extraction from tomato pulp has a detrimental effect on lycopene. Method Use of time-resolved fluorescence spectroscopy to monitor carotenoids in a hexane extract obtained from tomato pulp with application of ultrasound treatment (583 kHz). The resultant spectra were a combination of scattering and fluorescence. Because of their different timescales, decay associated spectra could be used to separate fluorescence and Raman information. This simultaneous acquisition of two complementary techniques was coupled with a very high time-resolution fluorescence lifetime measurement of the lycopene. Results Spectroscopic data showed the presence of phytofluene and chlorophyll in addition to lycopene in the tomato extract. The time-resolved spectral measurement containing both fluorescence and Raman data, coupled with high resolution time-resolved measurements, where a lifetime of ~5 ps was attributed to lycopene, indicated lycopene appeared unaltered by ultrasound treatment. Detrimental changes were, however, observed in both chlorophyll and phytofluene contributions. Conclusion Extracted lycopene appeared unaffected by ultrasound treatment, while other constituents (chlorophyll and phytofluene) were degraded.
Resumo:
Background and Objectives: The measurement of salivary immunoglobulin A is a useful and non-invasive method for measuring stress. Personality traits and rumination act as possible mediators in the relationship between psychological stressors and the immune system. This study was aimed to evaluate the levels of salivary IgA under psychological stress and its relationship with rumination and five personality traits in medical students. Methods: In this cross- sectional study, 45 medical students who intended to participate in the final exam were selected by simple random sampling. Two months before the exam, in the basal conditions, the NEO Personality Inventory-Short Form and Emotional Control Questionnaire (ECQ) were completed. Saliva samples were taken from students in both the basal conditions and exam stress conditions. Salivary IgA was measured by an ELISA test. Data was analyzed using paired samples T-test, Pearson correlation analysis, and stepwise regression. Results: A significant reduction of salivary IgA levels was found in exam stress conditions. Also, a significant negative correlation was found between traits of neuroticism and rumination with salivary IgA, as well as a significant positive correlation between of openness to experience and emotional inhibition with salivary IgA. Openness to experience and emotional inhibition may predict a substantial variance (34%) of salivary IgA under exam stress. Conclusions: Salivary IgA is reduced in response to exam stress. In addition, the rumination and personality traits may reduce or increase stress effects on the immune system, particularly the salivary IgA.
Resumo:
Sediment oxygen demand (SOD) can be a significant oxygen sink in various types of water bodies, particularly slow-moving waters with substantial organic sediment accumulation. In most settings where SOD is a concern, the prevailing hydraulic conditions are such that the impact of sediment resuspension on SOD is not considered. However, in the case of Bubbly Creek in Chicago, Illinois, the prevailing slack water conditions are interrupted by infrequent intervals of very high flow rates associated with pumped combined sewer overflow (CSO) during intense hydrologic events. These events can cause resuspension of the highly organic, nutrient-rich bottom sediments, resulting in precipitous drawdown of dissolved oxygen (DO) in the water column. While many past studies have addressed the dependence of SOD on near-bed velocity and bed shear stress prior to the point of sediment resuspension, there has been limited research that has attempted to characterize the complex and dynamic phenomenon of resuspended-sediment oxygen demand. To address this issue, a new in situ experimental apparatus referred to as the U of I Hydrodynamic SOD Sampler was designed to achieve a broad range of velocities and associated bed shear stresses. This allowed SOD to be analyzed across the spectrum of no sediment resuspension associated with low velocity/ bed shear stress through full sediment resuspension associated with high velocity / bed shear stress. The current study split SOD into two separate components: (1) SODNR is the sediment oxygen demand associated with non-resuspension conditions and is a surface sink calculated using traditional methods to yield a value with units (g/m2/day); and (2) SODR is the oxygen demand associated with resuspension conditions, which is a volumetric sink most accurately characterized using non-traditional methods and units that reflect suspension in the water column (mg/L/day). In the case of resuspension, the suspended sediment concentration was analyzed as a function of bed shear stress, and a formulation was developed to characterize SODR as a function of suspended sediment concentration in a form similar to first-order biochemical oxygen demand (BOD) kinetics with Monod DO term. The results obtained are intended to be implemented into a numerical model containing hydrodynamic, sediment transport, and water quality components to yield oxygen demand varying in both space and time for specific flow events. Such implementation will allow evaluation of proposed Bubbly Creek water quality improvement alternatives which take into account the impact of SOD under various flow conditions. Although the findings were based on experiments specific to the conditions in Bubbly Creek, the techniques and formulations developed in this study should be applicable to similar sites.
Resumo:
Streptococcus pneumoniae is a human pathobiont that colonizes the nasopharynx. S. pneumoniae is responsible for causing non-invasive and invasive disease such as otitis, pneumonia, meningitis, and sepsis, being a leading cause of infectious diseases worldwide. Due to similarities with closely related species sharing the same niche, it may be a challenge to correctly distinguish S. pneumoniae from its relatives when using only non-culture based methods such as real time PCR (qPCR). In 2007, a molecular method targeting the major autolysin (lytA) of S. pneumoniae by a qPCR assay was proposed by Carvalho and collaborators to identify pneumococcus. Since then, this method has been widely used worldwide. In 2013, the gene encoding for the ABC iron transporter lipoprotein PiaA, was proposed by Trzcinzki and collaborators to be used in parallel with the lytA qPCR assay. However, the presence of lytA gene homologues has been described in closely related species such as S. pseudopneumoniae and S. mitis and the presence of piaA gene is not ubiquitous between S. pneumoniae. The hyaluronate lyase gene (hylA) has been described to be ubiquitous in S. pneumoniae. This gene has not been used so far as a target for the identification of S. pneumoniae. The aims of our study were to evaluate the specificity, sensitivity, positive predicted value (PPV) and negative predicted value (NPV) of the lytA and piaA qPCR methods; design and implement a new assay targeting the hylA gene and evaluate the same parameters above described; analyze the assays independently and the possible combinations to access what is the best approach using qPCR to identify S. pneumoniae. A total of 278 previously characterized strains were tested: 61 S. pseudopneumoniae, 37 Viridans group strains, 30 type strains from other streptococcal species and 150 S. pneumoniae strains. The collection included both carriage and disease isolates. By Mulilocus Sequence Analysis (MLSA) we confirmed that strains of S. pseudopneumoniae could be misidentified as S. pneumoniae when lytA qPCR assay is used. The results showed that as a single target, lytA had the best combination of specificity, sensitivity, PPV and NPV being, 98.5%, 100.0%, 98.7% and 100.0% respectively. The combination of targets with the best values of specificity, sensibility, PPV and NPV were lytA and piaA, with 100.0%, 93.3%, 97.9% and 92.6%, respectively. Nonetheless by MLSA we confirmed that strains of S. pseudopneumoniae could be misidentified as S. pneumoniae and some capsulated (23F, 6B and 11A) and non-capsulated S. pneumoniae were not Identified using this assay. The hylA gene as a single target had the lowest PPV. Nonetheless it was capable to correctly identify all S. pneumoniae.
Resumo:
Chronic kidney disease (CKD) is associated with increased cardiovascular risk in comparison with the general population. This can be observed even in the early stages of CKD, and rises in proportion to the degree of renal impairment. Not only is cardiovascular disease (CVD) more prevalent in CKD, but its nature differs too, with an excess of morbidity and mortality associated with congestive cardiac failure, arrhythmia and sudden death, as well as the accelerated atherosclerosis which is also observed. Conventional cardiovascular risk factors such as hypertension, dyslipidaemia, obesity, glycaemia and smoking, are highly prevalent amongst patients with CKD, although in many of these examples the interaction between risk factor and disease differs from that which exists in normal renal function. Nevertheless, the extent of CVD cannot be fully explained by these conventional risk factors, and non-conventional factors specific to CKD are now recognised to contribute to the burden of CVD. Oxidative stress is a state characterised by excessive production of reactive oxygen species (ROS) and other radical species, a reduction in the capacity of antioxidant systems, and disturbance in normal redox homeostasis with depletion of protective vascular signalling molecules such as nitric oxide (NO). This results in oxidative damage to macromolecules such as lipids, proteins and DNA which can alter their functionality. Moreover, many enzymes are sensitive to redox regulation such that oxidative modification to cysteine thiol groups results in activation of signalling cascades which result in adverse cardiovascular effects such as vascular and endothelial dysfunction. Endothelial dysfunction and oxidative stress are present in association with many conventional cardiovascular risk factors, and can be observed even prior to the development of overt, clinical, vascular pathology, suggesting that these phenomena represent the earliest stages of CVD. In the presence of CKD, there is increased ROS production due to upregulated NADPH oxidase (NOX), increase in a circulating asymmetric dimethylarginine (ADMA), uncoupling of endothelial nitric oxide synthase (eNOS) as well as other mechanisms. There is also depletion in exogenous antioxidants such as ascorbic acid and tocopherol, and a reduction in activity of endogenous antioxidant systems regulated by the master gene regulator Nrf-2. In previous studies, circulating markers of oxidative stress have been shown to be increased in CKD, together with a reduction in endothelial function in a stepwise fashion relating to the severity of renal impairment. Not only is CVD linked to oxidative stress, but the progression of CKD itself is also in part dependent on redox sensitive mechanisms. For example, administration of the ROS scavenger tempol attenuates renal injury and reduces renal fibrosis seen on biopsy in a mouse model of CKD, whilst conversely, supplementation with the NOS inhibitor L-NAME causes proteinuria and renal impairment. Previous human studies examining the effect of antioxidant administration on vascular and renal function have been conflicting however. The work contained in this thesis therefore examines the effect of antioxidant administration on vascular and endothelial function in CKD. Firstly, 30 patients with CKD stages 3 – 5, and 20 matched hypertensive controls were recruited. Participants with CKD had lower ascorbic acid, higher TAP and ADMA, together with higher augmentation index and pulse wave velocity. There was no difference in baseline flow mediated dilatation (FMD) between groups. Intravenous ascorbic acid increased TAP and O2-, and reduced central BP and augmentation index in both groups, and lowered ADMA in the CKD group only. No effect on FMD was observed. The effects of ascorbic acid on kidney function was then investigated, however this was hindered by the inherent drawbacks of existing methods of non-invasively measuring kidney function. Arterial spin labelling MRI is an emerging imaging technique which allows measurement of renal perfusion without administration of an exogenous contrast agent. The technique relies upon application of an inversion pulse to blood within the vasculature proximal to the kidneys, which magnetically labels protons allowing measurement upon transit to the kidney. At the outset of this project local experience using ASL MRI was limited and there ensued a prolonged pre-clinical phase of testing with the aim of optimising imaging strategy. A study was then designed to investigate the repeatability of ASL MRI in a group of 12 healthy volunteers with normal renal function. The measured T1 longitudinal relaxation times and ASL MRI perfusion values were in keeping with those found in the literature; T1 time was 1376 ms in the cortex and 1491 ms in the whole kidney ROI, whilst perfusion was 321 mL/min/100g in the cortex, and 228 mL/min/100g in the whole kidney ROI. There was good reproducibility demonstrated on Bland Altman analysis, with a CVws was 9.2% for cortical perfusion and 7.1% for whole kidney perfusion. Subsequently, in a study of 17 patients with CKD and 24 healthy volunteers, the effects of ascorbic acid on renal perfusion was investigated. Although no change in renal perfusion was found following ascorbic acid, it was found that ASL MRI demonstrated significant differences between those with normal renal function and participants with CKD stages 3 – 5, with increased cortical and whole kidney T1, and reduced cortical and whole kidney perfusion. Interestingly, absolute perfusion showed a weak but significant correlation with progression of kidney disease over the preceding year. Ascorbic acid was therefore shown to have a significant effect on vascular biology both in CKD and in those with normal renal function, and to reduce ADMA only in patients with CKD. ASL MRI has shown promise as a non-invasive investigation of renal function and as a biomarker to identify individuals at high risk of progressive renal impairment.