878 resultados para Multi-resolution Method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel AC Biosusceptometry (ACB) system with thirteen sensors it was implemented and characterized in vitro using magnetic phantoms. The system presenting coils in a coaxial arrangement with one pair of excitation coil outside and thirteen pairs of detection coils inside. A first-order gradiometric configuration was utilized for optimal detection of magnetic signals. Several physical parameters such as baseline, number of turns, excitation field and diameters were studied for improvement of the signal/noise ratio. This system exhibits an enhanced sensitivity and spatial resolution, due to the higher density of sensors/area. In the future those characteristics will turn possible to obtain images of magnetic marker or tracer in the gastrointestinal tract focusing on physiological and pharmaceutical studies. ACB emerged due to its interesting nature, noninvasiveness and low cost to investigate gastrointestinal parameters and this system can contribute for more accurate interpretation of biomedical signals and images

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Habitat loss and fragmentation of landscapes endanger the planet’s biodiversity. Strategies for identify priority areas for conservation and restoration of biodiversity rich areas becomes essential for the planning of the management of these landscape become successful. This study aims to propose a novel, transparent and replicable method for choosing priority areas for restoration, and includes the following steps: (a) identification of regional biodiversity hotspots for conservation; (b) identification of priority areas for restoration with the greatest potential to increase the connectivity of the fragments already existing; (c) estimate the potential richness of understory birds before and after restoration, analyzing the gain of species for the future scenario. In order to identify the corridors to be restored in a future scenario we considered the approach of multiple corridors, which aimed to connect the main fragments within the region through analysis of multi-paths. Already existing regression models were applied to estimate the richness of the landscape considering three models: a) species richness as a function of patch area of the fragment selected as hotspots; b) richness as a function of areas connected by structural corridors and c) connected area for species which are able to access nearby fragments within 20m. The gain of species for future scenario which consider the potential restoration of selected areas was estimated. Based on our results we observed that species that use corridors showed the highest increment of species richness of understory birds. As a result it had to restore corridors to model species with the ability to use forest corridors was the highest gain potential species richness of understory birds. The methods proposed method in this study appears provide new ways to ensures a better cost / benefit relationship for restoration projects by increasing the chances of better reach high levels of...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the synthesis of highly conducting antimony-doped tin oxide (ATO) nanocrystals prepared via a nonaqueous sol–gel route in the size range of 4–6 nm and provides insights into its electrical properties. The antimony composition was varied from 1 to 18 mol% and the lowest resistivity (4.0 × 10−4Ω·cm) was observed at room temperature in the SnO2:8.8 mol% Sb composition. The samples were evaluated by X-ray diffraction, high-resolution transmission electron microscopy, energy-dispersive X-ray spectroscopy, and scanning electron microscope, and resistivity measurements were taken in the four-probe mode in the temperature range of 13–300 K. The results show highly crystalline nanoparticles in a monodisperse colloidal system, dependence on the shape of ATO nanoparticles as a function of Sb distribution, low resistivity, and semiconductor–metal transition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have studied the experimental conditions needed to produce LaNiO3 (LNO) nanostructures using a template-assisted method. In this route, a mesoporous anodic aluminum oxide template was filled with a chemical solution that had been prepared with polymeric precursors route. The precursor solutions and synthesized samples were characterized by X-ray diffraction (XRD), thermogravimetric analysis, infrared spectroscopy and high-resolution scanning electron microscopy (HRSEM). The XRD results for the samples that were heat-treated at 700 degrees C revealed that these samples crystallize in a perovskite-like LaNiO3 structure. HRSEM images revealed that the samples prepared with different deposition times (0.5, 1 and 2 h) promoted the formation of LaNiO3 nanotubes with different wall thicknesses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Piezoelectric transducers are widely used in high-resolution positioning systems. This paper reports the experimental analysis of a novel piezoelectric flextensional actuator (PFA), which is designed by using the topology-optimization method through a low-cost homodyne Michelson interferometer. By applying the J(1) - J(4) method for signal demodulation, which provides a linear and direct measurement of dynamic optical phase shift independent of fading, the nanometric displacements of the PFA were determined. Linearity and frequency response of the PFA were evaluated up to 50 kHz. PFA calibration factor and amplification rate were determined for the PFA operating in the quasi-static regime. To confirm the observed frequencies of resonance, an impedance analyzer is also utilized to measure the magnitude and phase of the PFA admittance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A stability-indication high performance liquid chromatographic method has been developed for the determination of norfloxacin in tablet dosage forms. Optimum separation was achieved in less than 7 minutes using Eclipse Plus Zorbax C18 Agilent, 150 mm×4.6 mm i.d., 5 μm particle size column. The analyte was resolved by using a mobile phase 5% acetic acid aqueous solution and methanol (80:20, v/v) at a flow rate 1.0 ml/min on an isocratic high performance liquid chromatographic system at a wavelength of 277 nm. Linearity, system suitability, precision, sensitivity, selectivity, specific, and robustness were established by International Conference Harmonization guidelines. For stress studies the drug was subjected to photolysis, oxidation, acid, alkaline and neutral conditions. The analytical conditions and the solvent developed provided good resolution within a short analysis time and economic advantages. The proposed method not required sophisticated and expensive instrumentation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ba1-xCaxTiO3, Ba1-xSrxTiO3 and Sr1-xCaxTiO3 (x = 0, 0.25, 0.50, 0.75 and 1) nanoparticles were synthesized using the microwave-assisted hydrothermal method. Samples were prepared for 40 minutes at 140°C under a pressure of 3 MPa using an adapted domestic microwave oven. The samples were characterized by X-Ray diffraction (XRD), scanning electron microscopy (FE-SEM), and Raman, photoluminescence (PL) and ultraviolet-visible (UV-Vis) spectroscopies. XRD data show that ceramic powders have crystalline phases associated with a short-range structural disorder. This structural disorder is confirmed by Raman spectral bands indicating multi-phonon processes and the presence of defects or impurities. Such defects account for a broad band in the photoluminescence spectrum in the green light (460 nm) region for all samples. Gap energy variation, obtained from UV-Vis spectra, suggest a non-uniform band structure of these titanates in accordance with the PL results. The morphology of each sample is changed with doping and varies from a spherical to cubic appearance for energy minimization.