879 resultados para Multi-criteria Evaluation
Resumo:
The aim of this study was to evaluate in vivo the use of low-level galium-aluminium-arsenide (GaAlAs) (BDP 600) laser and sodium fluoride varnish (Duraphat((R))) in the treatment of cervical dentine hypersensitivity. Twelve patients, with at least two sensitive teeth were selected. A total of 60 teeth were included in the trial. Prior to desensitizing treatment, dentine hypersensitivity was assessed by a thermal stimulus and patients' response to the examination was considered to be a control. The GaAlAs laser (15 mW, 4 J/cm(2)) was irradiated on contact mode and fluoride varnish was applied at cervical region. The efficiency of the treatments was assessed at three examination periods: immediately after first application, 15 and 30 days after the first application. The degree of sensitivity was determined following predefined criteria. Data were submitted to analysis and no statistically significant difference was observed between fluoride varnish and laser. Considering the treatments separately, there was no significant difference for the fluoride varnish at the three examination periods, and for laser therapy, significant difference (P < 0.05) was found solely between the values obtained before the treatment and 30 days after the first application. It may be concluded that both treatments may be effective in decreasing cervical dentinal hypersensitivity. Moreover, the low-level GaAlAs laser showed improved results for treating teeth with higher degree of sensitivity.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.
Resumo:
Iridium-, Ru-, and W-coated platforms were prepared by thermal treatment of the transversely heated graphite atomizer and investigated for the simultaneous determination of As, Bi, Pb, Sb, and Se in tap water by electrothermal atomic absorption spectrometry. The maximum pyrolysis temperature for As and Bi increased in a modifier sequence W < Ru < Ir. For Pb, Sb, and Se, this sequence was W < Ru, It. Calculated characteristic masses in the presence of It, Ru, and W were 35, 33, and 35 pg for As; 63, 51, and 52 pg for Bi; 50, 32, and 34 pg for Pb; 40, 35, and 31 pg for Sb; and 39, 39, and 93 pg for Se, respectively. Ruthenium was elected as the optimum modifier.Repeatability of the measurements was typically < 6%. Recoveries of As, Bi, Pb, Sb, and Se added to tap water samples varied from 79 to 109%. Accuracy was also checked by analysis of five certified reference materials (CRMs) from the National Institute of Standards and Technology (NIST1640 - Trace Elements in Natural Water; NIST 1643d Trace Elements in Water) and High Purity Standards (Trace Metals in Drinking Water Standards, lots #812708, #591107, and #710710). A paired t-test showed that the results for the CRMs were in agreement at the 95% confidence level with the certified values. The graphite tube lifetime was about 650 firings. multi-element determination is particularly challenging due to the necessity of carefully optimizing compromise conditions.Based on the considerations listed above, the aim of this paper was to evaluate the behavior of Ir, Ru, and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se. The performance of the proposed procedure was also verified after the ETAAS analysis of tap waters and reference materials.
Resumo:
Evaluation of the prevalence and characteristics of tinnitus in a Brazilian series of sleep bruxism patients. In this descriptive study, 100 patients (80 women and 20 men) were selected through the self-report of grinding teeth during sleep, confirmed by room mate or family member. They were evaluated according to a systematized approach: a questionnaire for orofacial pain and the Portuguese version of the Research Diagnostic Criteria for Temporomandibular Disorders. The patients were divided into two groups: group A, 54 patients with complaint of tinnitus and group B, 46 patients without tinnitus complaint. The mean age was 37.85 (13-66 years) and 34.02 years (20-59 years), respectively, for groups A and B (P = 0.1164). There was statistically significant difference between the two groups, with higher prevalence for the group A, in relation to: presence of chronic facial pain (P = 0.0007); number of areas painful to palpation in the masticatory and cervical muscles (P = 0.0032); myofascial pain in the masticatory muscles (P = 0.0003); absence of teeth without prosthetic replacement (P = 0.0145) and indices of depression (P = 0.0234). Structural alterations of the TMJ, like disc displacement and vertical dimension loss did not differ for the two groups. Tinnitus frequency was higher in patients with sleep bruxism and chronic facial pain. Myofascial pain, number of areas painful to palpation in the masticatory and cervical muscles, higher levels of depression and tooth absence without prosthetic replacement were more frequent in the group with tinnitus.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To verify a potential association between the presence of noncarious cervical lesions, parafunctional habits, and temporomandibular disorder (TMD) diagnosis. Method and Materials: Sample-size calculation provided a value of 130 participants with a confidence level of 95% and an error margin of 5%. A population of 132 volunteers (30 men: mean age, 23.7 +/- 3.05 years; 102 women: mean age, 24.9 +/- 5.86 years) underwent an oral examination and was interviewed by a trained dentist. The following parameters were registered: personal details, TMD diagnosis, parafunctional habits, and noncarious cervical lesion presence. The population was then divided into a noncarious cervical lesion group and a control group and subjected to the t test, chi-square test, Fisher exact test, and Spearman correlation (alpha = .05). Results: Noncarious cervical lesions were present in 39% of the population, with the largest concentrations found in the maxillary premolars (32%). The data showed a significant association between noncarious cervical lesion presence, tooth clenching (P = .03), and nail biting (P = .02), as well as a relation with TMD diagnosis (Fonseca Index [P = .01] and Research Diagnostic Criteria for TMD (RDC/TMD) [P = .004] ). In the noncarious cervical lesion group, direct rank correlation was found between maxillary premolars and clenching (P = .03), mandibular canines and nail biting (P = .05), and mandibular incisors and parafunctional habits without dental contacts (P = .02). Conclusion: Parafunctional habits and TMD presence should be taken into account in the diagnosis and treatment plan of noncarious cervical lesions.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Physical parameters of different types of lenses were measured through digital speckle pattern interferometry (DSPI) using a multimode diode laser as light source. When such lasers emit two or more longitudinal modes simultaneously the speckle image of an object appears covered of contour fringes. By performing the quantitative fringe evaluation the radii of curvature as well as the refractive indexes of the lenses were determined. The fringe quantitative evaluation was carried out through the four- and the eight-stepping techniques and the branch-cut method was employed for phase unwrapping. With all these parameters the focal length was calculated. This whole-field multi-wavelength method does enable the characterization of spherical and aspherical lenses and of positive and negative ones as well. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Objective: The goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class II restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class II standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z100 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5°C and 55°C for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: The results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.
Resumo:
Objective: To seek better understanding of chronic musculoskeletal facial pain and its relation to sleep bruxism, by comparing patients with sleep bruxism, with and without temporomandibular disorder. Design: Forty sleep bruxism patients were evaluated according to the Research Diagnostic Criteria for Temporomandibular Disorders: group A-20 patients with myofascial pain, 3 men, 17 women; average age 32.7 yr; mean duration of pain 4.37 yr; group B-20 without myofascial pain, 5 men, 15 women; average age 30.8 yr. Sleep and bruxism were evaluated in one-night polysomnography. Results: There were no statistically significant differences for bruxism and sleep variables of the two groups: number of bursts and bruxism episodes per hour, amplitude and duration of bruxism episodes, sleep efficiency and latency, percentage of non-REM and REM sleep, respiratory events, periodic limb movements, and micro-arousals. Conclusions: The polysomnographic characteristics of patients with sleep bruxism, with and without orofacial pain, are similar. More studies are necessary to clarify the reasons why some sleep bruxism patients develop chronic myofascial pain, and others do not. © 2006 Elsevier Ltd. All rights reserved.
Resumo:
Multiresistant Staphylococcus aureus constitutes an important public health problem, especially in view of its possible spread in nosocomial environments. In the present work, we analyzed the susceptibility profile of 80 S. aureus stains from human infections resistant to at least 10 drugs. For this study, the techniques used were the disk method and minimum inhibitory concentration (MIC) of the following drugs: cefuroxime, ciprofloxacin, clindamycin, erythromycin, gentamycin, imipenem, oxacillin, rifampicin, tetracycline and vancomycin, according the criteria of the National Committee for Clinical Laboratory Standards (NCCLS). Methicillin was included in the antibiogram as a marker, which is usually used in drugs selection for the treatment of staphylococcal infections. Results indicated that the most effective drug was vancomycin. For the other 10 drugs, the percentage of resistant strains ranged from 85% to 93.75%. In relation to the MICs, it was observed that vancomycin (MIC 90% = 0.615ug/ml) was the most effective drug; followed by rifampicin (MIC 90% = 2.6ug/ml) and ciprofloxacin (MIC 90% = 26.6ug/ml). The drugs that showed the least effective activity were cefuroxime, clindamycin, erythromycin, gentamycin, and oxacillin. On the other hand, observation of β-lactamase production revealed that most of the methicillin-resistant strains produced β-lactamase (83.7%), potentiating the risks of nosocomial infections. In general, vancomycin still continues to be one of the most effective drugs for staphylococcal infections therapy.
Resumo:
The application of multi-wavelength holography for surface shape measurement is presented. In our holographic setup a Bi12TiO 20 (BTO) photorefractive crystal was the holographic recording medium and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. The holographic imaging with multimode lasers results in multiple holograms in the BTO. By employing such lasers the resulting holographic image appears covered of interference fringes corresponding to the object relief and the interferogram spatial frequency is proportional to the diode laser free spectral range (FSR). We used a Fabry-Perot étalon at the laser output for laser mode selection. Thus, larger effective values of the laser FSR were achieved, leading to higher-spatial frequency interferograms and therefore to more sensitive and accurate measurements. The quantitative evaluation of the interferograms was performed through the phase stepping technique (PST) and the phase map unwrapping was carried out through the Cellular-Automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared, concerning measurement noise and visual inspection.
Resumo:
Toothpastes usually contain detergents, humectants, water colorant, fluoride and thickeners (e.g. silica). Tooth wear has a multi-factorial etilology and the use of abrasive dentifrices is related to abrasion of dental tissues during toothbrushing. This study evaluated in vitro the abrasiveness of a commercial silica gel low-abrasive dentrifice compared to an experimental dentifrice containing vegetable (almond) oil. Distilled water served as a control group. Acrylic specimens (8 per group) were submitted to simulated toothbrushing with slurries of the commercial dentifrice experimental dentifrice, almond oil and water in an automatic brushing machine programmed to 30,000 brush strokes for each specimen which is equivalent to 2 years of manual toothbrushing. Thereafter, surface roughness (Ra) of the specimens was analyzed with a Surfcorder SE 1700 profilometer. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) in the surface roughness after brushing with water almond oil experimental dentifrice. The commercial dentifrice produced rougher surfaces compared to the control and abrasive free products (p<0.05). Further studies are necessary in confirm the potential benefits of using vegetable oil in toothpaste as an alternative in abrasives in an attempt to minimize the tooth wear caused by toothbrushing.
Resumo:
Background. It has been suggested that the study of women who survive life-threatening complications related to pregnancy (maternal near-miss cases) may represent a practical alternative to surveillance of maternal morbidity/mortality since the number of cases is higher and the woman herself is able to provide information on the difficulties she faced and the long-term repercussions of the event. These repercussions, which may include sexual dysfunction, postpartum depression and posttraumatic stress disorder, may persist for prolonged periods of time, affecting women's quality of life and resulting in adverse effects to them and their babies. Objective. The aims of the present study are to create a nationwide network of scientific cooperation to carry out surveillance and estimate the frequency of maternal near-miss cases, to perform a multicenter investigation into the quality of care for women with severe complications of pregnancy, and to carry out a multidimensional evaluation of these women up to six months. Methods/Design. This project has two components: a multicenter, cross-sectional study to be implemented in 27 referral obstetric units in different geographical regions of Brazil, and a concurrent cohort study of multidimensional analysis. Over 12 months, investigators will perform prospective surveillance to identify all maternal complications. The population of the cross-sectional component will consist of all women surviving potentially life-threatening conditions (severe maternal complications) or life-threatening conditions (the maternal near miss criteria) and maternal deaths according to the new WHO definition and criteria. Data analysis will be performed in case subgroups according to the moment of occurrence and determining cause. Frequencies of near-miss and other severe maternal morbidity and the association between organ dysfunction and maternal death will be estimated. A proportion of cases identified in the cross-sectional study will comprise the cohort of women for the multidimensional analysis. Various aspects of the lives of women surviving severe maternal complications will be evaluated 3 and 6 months after the event and compared to a group of women who suffered no severe complications in pregnancy. Previously validated questionnaires will be used in the interviews to assess reproductive function, posttraumatic stress, functional capacity, quality of life, sexual function, postpartum depression and infant development. © 2009 Cecatti et al.