999 resultados para Mid-air collisions
Resumo:
The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.
Resumo:
This work deals with the cooling of high-speed electric machines, such as motors and generators, through an air gap. It consists of numerical and experimental modelling of gas flow and heat transfer in an annular channel. Velocity and temperature profiles are modelled in the air gap of a high-speed testmachine. Local and mean heat transfer coefficients and total friction coefficients are attained for a smooth rotor-stator combination at a large velocity range. The aim is to solve the heat transfer numerically and experimentally. The FINFLO software, developed at Helsinki University of Technology, has been used in the flow solution, and the commercial IGG and Field view programs for the grid generation and post processing. The annular channel is discretized as a sector mesh. Calculation is performed with constant mass flow rate on six rotational speeds. The effect of turbulence is calculated using three turbulence models. The friction coefficient and velocity factor are attained via total friction power. The first part of experimental section consists of finding the proper sensors and calibrating them in a straight pipe. After preliminary tests, a RdF-sensor is glued on the walls of stator and rotor surfaces. Telemetry is needed to be able to measure the heat transfer coefficients at the rotor. The mean heat transfer coefficients are measured in a test machine on four cooling air mass flow rates at a wide Couette Reynolds number range. The calculated values concerning the friction and heat transfer coefficients are compared with measured and semi-empirical data. Heat is transferred from the hotter stator and rotor surfaces to the coolerair flow in the air gap, not from the rotor to the stator via the air gap, althought the stator temperature is lower than the rotor temperature. The calculatedfriction coefficients fits well with the semi-empirical equations and precedingmeasurements. On constant mass flow rate the rotor heat transfer coefficient attains a saturation point at a higher rotational speed, while the heat transfer coefficient of the stator grows uniformly. The magnitudes of the heat transfer coefficients are almost constant with different turbulence models. The calibrationof sensors in a straight pipe is only an advisory step in the selection process. Telemetry is tested in the pipe conditions and compared to the same measurements with a plain sensor. The magnitudes of the measured data and the data from the semi-empirical equation are higher for the heat transfer coefficients than thenumerical data considered on the velocity range. Friction and heat transfer coefficients are presented in a large velocity range in the report. The goals are reached acceptably using numerical and experimental research. The next challenge is to achieve results for grooved stator-rotor combinations. The work contains also results for an air gap with a grooved stator with 36 slots. The velocity field by the numerical method does not match in every respect the estimated flow mode. The absence of secondary Taylor vortices is evident when using time averagednumerical simulation.
Resumo:
A study was conducted to determine the possibility of cashew (Anacardium occidentale) cloning by air-layering and influence of IBA (indol-butyric acid) on this process. It was adopted a completely randomized design with 4 treatments, 10 air layers each and 4 replications, reaching 160 air layers. The IBA levels on the treatments were, as follow: 0, 1000, 3000 and 5000 mg.kg-1. It was evaluated: survival, callus and rooting percentage, average number and length of roots. The highest survival rate (67.5%) was registered with no growth regulator and IBA at 1000 mg.kg-1, while the best rooting percentage (82%) referred to 1000 mg.kg-1. In spite of average number and length of roots, the highest results were observed with IBA at 5000 mg.kg-1. IBA concentrations had no influence on cashew air-layering formation.
Resumo:
BACKGROUND: There are limited data on the composition and smoke emissions of 'herbal' shisha products and the air quality of establishments where they are smoked. METHODS: Three studies of 'herbal' shisha were conducted: (1) samples of 'herbal' shisha products were chemically analysed; (2) 'herbal' and tobacco shisha were burned in a waterpipe smoking machine and main and sidestream smoke analysed by standard methods and (3) the air quality of six waterpipe cafes was assessed by measurement of CO, particulate and nicotine vapour content. RESULTS: We found considerable variation in heavy metal content between the three products sampled, one being particularly high in lead, chromium, nickel and arsenic. A similar pattern emerged for polycyclic aromatic hydrocarbons. Smoke emission analyses indicated that toxic byproducts produced by the combustion of 'herbal' shisha were equivalent or greater than those produced by tobacco shisha. The results of our air quality assessment demonstrated that mean PM2.5 levels and CO content were significantly higher in waterpipe establishments compared to a casino where cigarette smoking was permitted. Nicotine vapour was detected in one of the waterpipe cafes. CONCLUSIONS: 'Herbal' shisha products tested contained toxic trace metals and PAHs levels equivalent to, or in excess of, that found in cigarettes. Their mainstream and sidestream smoke emissions contained carcinogens equivalent to, or in excess of, those of tobacco products. The content of the air in the waterpipe cafes tested was potentially hazardous. These data, in aggregate, suggest that smoking 'herbal' shisha may well be dangerous to health.
Resumo:
Helsingfors : A.W. Gröndahl & A.C. Öhman 1845 : Dresden, Adler u. Dietze
Resumo:
Inclusive doubly differential cross sections d 2 σ pA /dx F dp T 2 as a function of Feynman-x (x F ) and transverse momentum (p T ) for the production of K S 0 , Λ and Λ¯ in proton-nucleus interactions at 920 GeV are presented. The measurements were performed by HERA-B in the negative x F range (−0.12
Resumo:
We apply social networks analysis to the study of an important database on investment and companies" share in the Catalonia (Spain) of the nineteenth century. In contrast with most of the existing related literature, usually addressing power relationships across administration boards, we focus on the structure of interactions among individual investors and firms. Centrality analysis uncovers interesting roles played by certain economic sectors (e.g. textile and financial). Furthermore, the diverse composition (in terms of economic activity) of communities in the network (subgroups more densely connected internally than with the rest of the network) reveals a high investment diversification, which nicely agrees with a known characteristic of traditional Catalan business strategies.
Resumo:
Ectopic ACTH Cushing's syndrome (EAS) is often caused by neuroendocrine tumors (NETs) of lungs, pancreas, thymus, and other less frequent locations. Localizing the source of ACTH can be challenging. A 64-year-old man presented with rapidly progressing fatigue, muscular weakness, and dyspnea. He was in poor condition and showed facial redness, proximal amyotrophy, and bruises. Laboratory disclosed hypokalemia, metabolic alkalosis, and markedly elevated ACTH and cortisol levels. Pituitary was normal on magnetic resonance imaging (MRI), and bilateral inferior petrosal sinus blood sampling with corticotropin-releasing hormone stimulation showed no significant central-to-periphery gradient of ACTH. Head and neck, thoracic and abdominal computerized tomography (CT), MRI, somatostatin receptor scintigraphy (SSRS), and (18)F-deoxyglucose-positron emission tomography (FDG-PET) failed to identify the primary tumor. (18)F-dihydroxyphenylalanine (F-DOPA)-PET/CT unveiled a 20-mm nodule in the jejunum and a metastatic lymph node. Segmental jejunum resection showed two adjacent NETs, measuring 2.0 and 0.5 cm with a peritoneal metastasis. The largest tumor expressed ACTH in 30% of cells. Following surgery, after a transient adrenal insufficiency, ACTH and cortisol levels returned to normal values and remain normal over a follow-up of 26 months. Small mid-gut NETs are difficult to localize on CT or MRI, and require metabolic imaging. Owing to low mitotic activity, NETs are generally poor candidates for FDG-PET, whereas SSRS shows poor sensitivity in EAS due to intrinsically low tumor concentration of type-2 somatostatin receptors (SST2) or to receptor down regulation by excess cortisol. However, F-DOPA-PET, which is related to amine precursor uptake by NETs, has been reported to have high positive predictive value for occult EAS despite low sensitivity, and constitutes a useful alternative to more conventional methods of tumor localization. LEARNING POINTS: Uncontrolled high cortisol levels in EAS can be lethal if untreated.Surgical excision is the keystone of NETs treatment, thus tumor localization is crucial.Most cases of EAS are caused by NETs, which are located mainly in the lungs. However, small gut NETs are elusive to conventional imaging and require metabolic imaging for detection.FDG-PET, based on tumor high metabolic rate, may not detect NETs that have low mitotic activity. SSRS may also fail, due to absent or low concentration of SST2, which may be down regulated by excess cortisol.F-DOPA-PET, based on amine-precursor uptake, can be a useful method to localize the occult source of ACTH in EAS when other methods have failed.
Resumo:
A study of the angular distributions of leptons from decays of J/ψ"s produced in p-C and p-W collisions at s√=41.6~GeV has been performed in the J/ψ Feynman-x region −0.34
Resumo:
Tämän diplomityön tarkoituksena oli asentaa ja kehittää UPM-Kymmene Rauman tehtaiden PK2:lle luotettava ja toimiva ilmanläpäisyprofiilin mittaus. Työn tarkoituksena oli myös kartoittaa tietoja ilmanläpäisyprofiiliin vaikuttavista seikoista sekä mahdollisuuksista säätää ilmanläpäisyprofiilia. Lisäksi työn tavoitteena oli löytää toimiva menetelmä verrata online mitattua ilmanläpäisyprofiilia laboratoriossa mitattuun ilmanläpäisyprofiiliin online mittauksen luotettavuuden näkökulmasta. Työn aikana selvitettiin myös ilmanläpäisyprofiilin mittauksen mahdollisuutta superkalanteroidusta SC paperista. Työn kirjallisessa osassa käsiteltiin paperin huokoisuutta ja ilmanläpäisyä, huokoisuustasoon ja huokoisuus profiiliin vaikuttavia tekijöitä, ilmanläpäisevyyden merkitystä SC paperin valmistukselle ja SC paperin painettavuudelle sekä ilmanläpäisevyyden laboratorio- sekä online mittausta. Kirjallisessa osassa käsiteltiin myös Honeywellin uutta Poros ilmanläpäisysensoria. Työn kokeellisessa osassa tutkittiin ilmanläpäisyprofiilimittauksen luotettavuutta CD ja MD suunnassa sekä laboratorio- ja online-mittausten välisiä eroavaisuuksia ennen PK2 uusintaa. PK2 uusinnan jälkeen kokeellisessa osassa keskityttiin luotettavuuden varmentamiseen CD ja MD suunnassa sekä kartoittamaan tekijöitä, jotka aiheuttivat pieniä tasoeroja mittausten välillä. Mittaukset todettiin luotettaviksi ja niiden pohjalta suoritettiin mitattujen online profiilien välisiä vertailuja. Ilmanläpäisyprofiililla todettiin olevan positiivinen korrelaatio neliömassaprofiilin ja kosteusprofiilin kanssa sekä negatiivinen korrelaatio tuhkaprofiilin kanssa. PK2 uusinnan yhteydessä tehtiin koeajoja, jotka liittyivät laadunoptimointiin viira- ja puristinosalla. Koeajoissa tutkittujen asioiden lisäksi tutkittiin muutettujen parametrien vaikutusta ilmanläpäisyprofiiliin. Höyrylaatikon vaikutusta ilmanläpäisyprofiiliin tutkittiin säätöjen virityksen yhteydessä.
Resumo:
Työssä tarkastellaan kahta kaasuturbiinin imuilman sisäänottojärjestelmän kehitysmenetelmää, imuilman jäähdytystä ja sähköstaattista suodatusta. Imuilman jäähdytysmenetelmien tarkastelussa käytettiin kahta kaasuturbiinin tehonlisäystekniikoiden laskentatyökalua. Arviointi kohdistettiin Glanford Brigg Generating Station -voimalaitoksen kaasuturbiinityyppiin ja paikallisiin englantilaisiin ilmasto-olosuhteisiin. Tarkastelussa olivat kostutusjäähdytys ja overspray. Tuloksia vertailtiin keskenään ja näiden perusteella arvioitiin menetelmien vaikutuksia tehoon, hyötysuhteeseen sekä veden kulutukseen. Sähköstaattisen suodattimen prototyyppi oli rakennettu Briggin voimalaitokselle. Järjestelmää kehitetään kaupalliseksi tuotteeksi ja tätä varten kerättiin tekninen dokumentaatio kokonaisuudeksi, jota voitiin hyödyntää tuotteistusprosessissa. Imuilman jäähdyttämisellä voidaan saavuttaa merkittävä tehonlisäys ilmasto-olosuhteista riippuen. Menetelmällä voidaan myös tasata lämpötilan vuorokausi-vaihtelusta aiheutuvia tehoeroja. Sähköstaattisen suodattimen prototyyppi saavutti kehitysvaiheelle asetetut tavoitteet. Sähköstaattinen suodatus tarjoaa useita etuja perinteiseen mekaaniseen suodatukseen verrattuna.
Resumo:
We numerically simulate planar shock wave collisions in anti-de Sitter space as a model for heavy ion collisions of large nuclei. We uncover a crossover between two different dynamical regimes as a function of the collision energy. At low energies the shocks first stop and then explode in a manner approximately described by hydrodynamics, in close similarity with the Landau model. At high energies the receding fragments move outwards at the speed of light, with a region of negative energy density and negative longitudinal pressure trailing behind them. The rapidity distribution of the energy density at late times around midrapidity is not approximately boost invariant but Gaussian, albeit with a width that increases with the collision energy.