943 resultados para Microneedle electrodes
Resumo:
The concept of temporal 'plus' epilepsy (T+E) is not new, and a number of observations made by means of intracerebral electrodes have illustrated the complexity of neuronal circuits that involve the temporal lobe. The term T+E was used to unify and better individualize these specific forms of multilobar epilepsies, which are characterized by electroclinical features primarily suggestive of temporal lobe epilepsy, MRI findings that are either unremarkable or show signs of hippocampal sclerosis, and intracranial recordings which demonstrate that seizures arise from a complex epileptogenic network including a combination of brain regions located within the temporal lobe and over closed neighbouring structures such as the orbitofrontal cortex, the insulo-opercular region, and the temporo-parieto-occipital junction. We will review here how the term of T+E has emerged, what it means, and which practical consideration it raises.
Resumo:
This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.
Resumo:
La stimulation cérébrale profonde (SCP) nécessite l'implantation chirurgicale d'un système comprenant électrodes cérébrales et boîtier(s) de stimulation. Les noyaux cérébraux visés par la méthodologie stéréotaxique d'implantation doivent être visualisés au mieux par une imagerie à haute résolution. La procédure chirurgicale d'implantation des électrodes se fait si possible en anesthésie locale pour faire des mesures électro-physiologiques et tester en peropératoire l'effet de la stimulation, afin d'optimiser la position de l'électrode définitive. Dans un deuxième temps, le ou les générateur(s) d'impulsions sont implantés en anesthésie générale. La SCP pour les mouvements anormaux a une très bonne efficacité et un risque de complications graves faible quoique non nul. Les complications liées au matériel sont les plus fréquentes. Deep brain stimulation (DBS) requires the surgical implantation of a system including brain electrodes and impulsion generator(s). The nuclei targeted by the stereotaxic implantation methodology have to be visualized at best by high resolution imaging. The surgical procedure for implanting the electrodes is performed if possible under local anaesthesia to make electro-physiological measurements and to test intra-operatively the effect of the stimulation, in order to optimize the position of the definitive electrode. In a second step, the impulsion generator(s) are implanted under general anaesthesia. DBS for movement disorders has a very good efficacy and a low albeit non-zero risk of serious complications. Complications related to the material are the most common.
Resumo:
BACKGROUND: Deep brain stimulation (DBS) is recognized as an effective treatment for movement disorders. We recently changed our technique, limiting the number of brain penetrations to three per side. OBJECTIVES: The first aim was to evaluate the electrode precision on both sides of surgery since we implemented this surgical technique. The second aim was to analyse whether or not the electrode placement was improved with microrecording and macrostimulation. METHODS: We retrospectively reviewed operation protocols and MRIs of 30 patients who underwent bilateral DBS. For microrecording and macrostimulation, we used three parallel channels of the 'Ben Gun' centred on the MRI-planned target. Pre- and post-operative MRIs were merged. The distance between the planned target and the centre of the implanted electrode artefact was measured. RESULTS: There was no significant difference in targeting precision on both sides of surgery. There was more intra-operative adjustment of the second electrode positioning based on microrecording and macrostimulation, which allowed to significantly approach the MRI-planned target on the medial-lateral axis. CONCLUSION: There was more electrode adjustment needed on the second side, possibly in relation with brain shift. We thus suggest performing a single central track with electrophysiological and clinical assessment, with multidirectional exploration on demand for suboptimal clinical responses.
Resumo:
The Tandem-GMAW method is the latest development as the consequences of improvements in the welding methods. The twin-wire and then the Tandem-method with the separate power sources has got a remarkable place in the welding of many types of materials with different joint types. The biggest advantage of Tandem welding method is the flexibility of choosing both the electrodes of different types from each other according to the type of the parent material. This is possible because of the feasibility of setting the separate welding parameters for both the wires. In this thesis work the effect of the variation in three parameters on the weld bead in Tandem-GMA welding method is studied. Theses three parameters are the wire feed rate in the slave wire, the wire feed rate in the master wire and the voltage difference in both the wires. The results are then compared to study the behaviour of the weld bead with the change in these parameters.
Resumo:
Työn tavoitteena oli tutkia eri mittausmenetelmillä metallipinnoitettujen elektrodien kulumista kulumiskokeiden aikana. Mittausmenetelminä olivat käytössä syklinen voltammetria, polarisaatiokäyrän määritys ja sähkökemiallinen impedanssispektrometria, jotka olivat offline-mittausmenetelmiä. Näiden menetelmien avulla pystyttiin seuraamaan yksittäisten elektrodien kulumista ajon aikana. Elektrodin pinnoitteen alkuaineiden pitoisuuksia tutkittiin myös elektronimikroskoopin röntgenspektrometrin avulla. Työn aikana tehdyissä kulumiskokeista havaittiin elektrodin kuluvan sitä nopeammin mitä suurempi on virrantiheys. Työssä tehtyjen elektronimikroskooppikokeiden avulla havaittiin, että harvinaisten metallien seostaminen pinnoitteeseen pidentää metallipinnoitetun elektrodin käyttöikää. Syklisen voltammetrian avulla pystyttiin seuraamaan elektrodin pinta-alan muuttumista ajon aikana. Työssä käytettyjen kulumiskokeiden avulla ei suoranaisesti pystytty määrittämään elektrodin jäljellä olevaa elinikää.
Resumo:
The very usual columnar growth of nanocrystalline silicon leads to electronic transport anisotropies. Whereas electrical measurements with coplanar electrodes only provide information about the electronic transport parallel to the substrate, it is the transverse transport which determines the collection efficiency in thin film solar cells. Hence, Schottky diodes on transparent electrodes were obtained by hot-wire CVD in order to perform external quantum efficiency and surface photovoltage studies in sandwich configuration. These measurements allowed to calculate a transverse collection length, which must correlate with the photovoltaic performance of thin film solar cells. Furthermore, the density of charge trapped at localized states in the bandgap was estimated from the voltage dependence of the depletion capacitance of these rectifying contacts.
Resumo:
To develop systems in order to detect Alzheimer’s disease we want to use EEG signals. Available database is raw, so the first step must be to clean signals properly. We propose a new way of ICA cleaning on a database recorded from patients with Alzheimer's disease (mildAD, early stage). Two researchers visually inspected all the signals (EEG channels), and each recording's least corrupted (artefact-clean) continuous 20 sec interval were chosen for the analysis. Each trial was then decomposed using ICA. Sources were ordered using a kurtosis measure, and the researchers cleared up to seven sources per trial corresponding to artefacts (eye movements, EMG corruption, EKG, etc), using three criteria: (i) Isolated source on the scalp (only a few electrodes contribute to the source), (ii) Abnormal wave shape (drifts, eye blinks, sharp waves, etc.), (iii) Source of abnormally high amplitude ( �100 �V). We then evaluated the outcome of this cleaning by means of the classification of patients using multilayer perceptron neural networks. Results are very satisfactory and performance is increased from 50.9% to 73.1% correctly classified data using ICA cleaning procedure.
Resumo:
The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.
Resumo:
Zinc indium tin oxide (ZITO) transparent conductive oxide layers were deposited via radio frequency (RF) magnetron co-sputtering at room temperature. A series of samples with gradually varying zinc content was investigated. The samples were characterized with x-ray and ultraviolet photoemission spectroscopy (XPS, UPS) to determine the electronic structure of the surface. Valence and conduction bands maxima (VBM, CBM), and work function were determined. The experiments indicate that increasing Zn content results in films with a higher defect rate at the surface leading to the formation of a degenerately doped surface layer if the Zn content surpasses 50%. Furthermore, the experiments demonstrate that ZITO is susceptible to ultraviolet light induced work function reduction, similar to what was earlier observed on ITO and TiO2 films.
Resumo:
Les pistolets à impulsion électrique (PIE) sont de plus en plus fréquemment utilisés en Europe ces dernières années, le modèle le plus connu étant le Taser®. Les connaissances scientifiques concernant les PIE et leurs effets potentiels restent toutefois limitées. Nous avons conduit une revue de littérature afin d'évaluer les implications potentielles de leur utilisation en termes de sécurité, de morbidité et de mortalité. Une exposition unique chez un individu sain peut généralement être considérée comme peu dangereuse. Les sujets à risque de complications sont les individus exposés à de multiples décharges, les personnes sous l'influence de substances psychoactives, ceux qui montrent des signes d'agitation extrême, ou encore les individus présentant des comorbidités médicales. L'éventail des complications pouvant survenir lors de leur exposition est large et inclut les lésions provoquées par les impacts des électrodes, les traumatismes liés à la chute induite par la paralysie transitoire ou des complications cardiovasculaires. Dans ce contexte, les personnes exposées doivent être examinées attentivement, et les éventuelles lésions traumatiques doivent être exclues. The use of electronic control devices (ECD), such as the Taser®, has increased in Europe over the past decade. However, scientific data concerning the potential health impact of ECD usage remains limited. We reviewed the scientific literature in order to evaluate the safety, mortality, and morbidity associated with ECD use. Exposure of a healthy individual to a single ECD electroshock can be considered generally safe. Complications can, however, occur if the patient is subject to multiple electroshocks, if the patient has significant medical comorbidities, or when exposure is associated with drug abuse or agitated delirium. The broad spectrum of potential complications associated with ECD exposure includes direct trauma caused by the ECD electrodes, injuries caused by the transient paralysis-induced fall, and cardiovascular events. An ECD-exposed patient requires careful examination during which traumatic injuries are actively sought out.
Resumo:
This review discusses the present state of the art of the stereochemistry of electrochemical reactions. The extent of asymmetric induction is progressing, but in general diastereoselectivities and enantioselectivities remain behind those from chemical synthesis. In recent years, new methodological developments have been successful. Effects that play important roles in homogeneous chemistry have been used with success. Lack of expressive enantiomeric excess (ee) could be related to the absence of tightly organized structures during the reaction of interest. The highest ee might be expected for redox reactions where conformational preference in transition state plays the important role or for the ones performed while adsorbed on the electrode, and where the chiral element is also at the surface, either adsorbed or chemically bound to the surface and interacting directly with the substrate. Electroenzymatic synthesis has a promising future.
Resumo:
Chemically modified electrodes (CMEs) have been subject of considerable attention since its inception about 23 years ago. CMEs result of a deliberate immobilization of a modifier agent onto the electrode surface obtained through chemical reactions, chemisorption, composite formation or polymer coating. This immobilization seeks transfer the physicochemical properties of the modifier to the electrode surface and thus to dictate and control the behavior of the electrode/solution interface. In recent years the interest in CMEs has increased particularly to enhance the sensitivity and/or the selectivity of electroanalytical techniques. In general higher sensitivity and/or selectivity may be achieved by exploiting one or more of the following phenomena: electrocatalysis, preconcentration and interferents exclusion. This paper deals with the application of CMEs in electroanalysis, including a brief presentation of the more general procedures that have been employed for the modification of electrode surfaces.
Resumo:
A review is given about the most relevant advances on the analytical applications of conducting polymers in potentiometric sensors. These organic polymers represent a new class of materials with conducting properties due to its doping by ions. Several polymers already were synthesized such as polypyrrole, polyaniline, polythiophene, among others. Particular attention is devoted to the main advantages supplied by ion selective electrodes and gas sensors using conducting polymers, as well as the incorporation of bioactive elements in these polymers for the construction of biosensors. The correlation between structure, stability and ability to ion exchange of some conducting polymers applied as potentiometric transducers, is discussed.
Resumo:
Studies of the kinetics of electrocatalytic reactions on well oriented single crystal surfaces have demonstrated the influence of surface structure on the rate and mechanisms of many electrochemical processes. The preparation and characterization of these surfaces is the first step in this type of studies. In this paper, a methodology employed in order to ensure the quality and cleanliness of single crystals and their utilization as rotating electrodes is described.