1000 resultados para Microclimatic conditions
Resumo:
Infectious diseases are a continuing threat to all people, regardless of age, gender, lifestyle, ethnic background, or socioeconomic status. They cause illness, suffering and even death, and place an enormous financial burden on society. Although modern advances have controlled some infectious diseases, new ones are constantly emerging. State public health officials rely on local public health agencies, healthcare providers, laboratories and other public health personnel to report the occurrence of notifiable diseases. Without such data, trends cannot be accurately monitored, unusual occurrences of diseases (such as outbreaks) might not be detected or appropriately responded to, and the effectiveness of control and prevention activities cannot be evaluated.
'Royal Gala' apple quality stored under ultralow oxygen concentration and low temperature conditions
Resumo:
The objective of this work was to evaluate the interaction of ultralow oxygen concentrations (ULO) with storage temperatures and carbon dioxide partial pressures and its influence on fruit quality preservation and on the occurrence of physiological disorders in 'Royal Gala' apples. The experiment was carried out in a completely randomized design, with four replicates 25-fruit. ULO conditions (1.0 kPa O2 + 2.0 kPa CO2; 0.8 kPa O2 + 1.5 kPa CO2; 0.8 kPa O2 + 1.0 kPa CO2; 0.6 kPa O2 + 1.5 kPa CO2; and 0.6 kPa O2 + 1.0 kPa CO2) were tested at 0, 0.5 and 1.0°C, in a 5x3 factorial arrangement. Fruit quality and ripening analyses were performed after eight-month storage plus seven days of shelf-life at 20°C. Oxygen partial pressures below 0.8 kPa increased the occurrence of internal breakdown and mealiness. The best ULO condition was 1.0 kPa O2 + plus 2.0 kPa CO2 at 1.0°C. The interaction of ULO conditions and storage temperatures shows the need of increasing O2 partial pressure at higher storage temperatures.
Resumo:
Identifying the factors that mediate covariation between an ornament and other phenotypic attributes is important to determine the signaling function of ornaments. Sign and magnitude of a covariation may vary across environments if the expression of the ornament or of its linked genes regulating correlated phenotypes is condition-dependent. I investigated in the barn owl Tyto alba whether sign and magnitude of covariation between body mass and two heritable melanin-based plumage ornaments change with food supply, along the reproductive cycle and from the morning to the evening. Using a dataset of 1,848 measurements of body mass in 336 breeding females, I found that females displaying large black spots were heavier than conspecifics with smaller spots in the afternoon (i.e., a long time after the last feeding) but not in the morning (i.e., a short time after the last feeding). This is consistent with the recently proposed hypothesis that eumelanin-based ornaments are associated with the ability to maintain energy balance between food intake and energy expenditure. Thus, covariation between melanin-based coloration and body mass can be detected only under specific conditions potentially explaining why it has been reported in only ten out of 28 vertebrate species. The proposition that ornamented individuals achieve a higher fitness than drab conspecifics only in specific environments should be tested for other ornaments.
Resumo:
Isotopic and trace element compositions of Miocene and Pliocene phosphatic brachiopods (Lingulidae and Discinidae) from southern North Sea, the Central Paratethys and the Atlantic coast of Europe were investigated in order to trace past environmental conditions and marine connections between the northern boreal and the southern subtropical-tropical marine basins. The North Sea genus Glottidia yielded low epsilon(Nd) and high delta O-18(PO4) values through the Mio-Pliocene indicating cold habitat temperature where the local seawater was dominated by the Atlantic Ocean. In contrast, the Middle Miocene Lingulidae and Discinidae of the Paratethys inhabited warm subtropical seawater with the possible influence of the Indian Ocean via the Mediterranean, as supported by their average epsilon(Nd) value of -8.3. The combined geochemical data support a thermal and marine separation of the Paratethys from the North Sea with no direct connection or major exchange of water from the Miocene onwards. The temperature in the Paratethys was very similar to that inferred from brachiopods from the Middle Miocene of western France, but the seawater epsilon(Nd) value here is identical to that of contemporaneous Atlantic Ocean. A Late Miocene lingulid brachiopod from southern Portugal has a high delta O-18(PO4), similar to the specimens investigated from the North Sea, reflecting either a deep water habitat or formation after the onset of major global cooling that resulted in an increased delta O-18 value of seawater. The epsilon(Nd) value of -8.4 for this site is compatible with an influence of Mediterranean outflow. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Objectif Le présent travail a consisté à identifier et comparer, au moyen d'un questionnaire auto-administré, les conditions ergonomiques, les nuisances environnementales et les facteurs de stress rencontrés par le personnel soignant (n = 35) et le personnel pénitentiaire (n = 240) travaillant dans les mêmes prisons. Quatre ans ont séparé la remise du questionnaire auprès des surveillants et des soignants, ce qui limite la portée des résultats. Malgré cela, la comparaison des données fournies montre des tendances intéressantes. Résultats Sur un plan ergonomique, les soignants rencontrent une plus faible pénibilité que les surveillants. Sur un plan environnemental, les soignants sont gênés par un nombre moins important de nuisances que les surveillants, ces derniers étant exposés à des conditions très diverses de travail (divisions de haute sécurité, ateliers de production, domaines agricoles). Par contre, concernant les facteurs de stress, les soignants éprouvent des tensions dans des proportions presque identiques aux surveillants, suite aux interventions d'urgences, à la surcharge de travail, aux relations avec les détenus et à la mauvaise ambiance au travail. En outre, les soignants et surveillants paraissent souffrir différemment d'éléments d'organisation tels que le sentiment de travailler sous pression, le manque d'écoute et le manque de considération. Enfin les soignants signalent un risque de violence plus élevé ainsi qu'un manque de reconnaissance plus important que les surveillants. Conclusion Les surveillants doivent continuer à faire l'objet d'un suivi attentif des services de santé au travail. En ce qui concerne les soignants, l'accent doit être mis sur l'amélioration de leur organisation interne de travail en approfondissant, entre autres, la question du manque de reconnaissance, le sentiment de travail sous pression, ainsi qu'en poursuivant les efforts sur la formation à la lutte contre la violence. [Auteurs]
Resumo:
The objective of this work was to analyze the growth of champa fruit (Campomanesia lineatifolia) as a function of growing-degree days (GDD) in the municipality of Miraflores, in Boyacá, Colombia. Thirty trees were selected at random, and 100 flowers in full bloom were marked in each tree. From the 26th day after flowering until harvest, 10 samples were taken every 15 days to determine the fruit parameters and growth rate. Temperature was recorded to calculate the GDD. From flowering until harvest, 1,489.1 GDD were accumulated over 145 days. Dry and fresh matter mass of pulp, seed, and total fruit were fitted to a logistic growth model, and three growth stages (S1, S2 and S3) were defined. In the S1, growth was slow, and the relative growth remained nearly stable, whereas the absolute growth rate (AGR) increased slowly. In the S2, maximum growth was observed. In the S3, which corresponds to maturation, dry mass increased gradually, and the AGR decreased, while the fresh pulp and total mass did not cease to increase. The polar and equatorial diameters increased linearly, while the volume followed an exponential model. Champa fruit show a simple sigmoid growth curve.
Resumo:
The objective of this work was to evaluate an estimation system for rice yield in Brazil, based on simple agrometeorological models and on the technological level of production systems. This estimation system incorporates the conceptual basis proposed by Doorenbos & Kassam for potential and attainable yields with empirical adjusts for maximum yield and crop sensitivity to water deficit, considering five categories of rice yield. Rice yield was estimated from 2000/2001 to 2007/2008, and compared to IBGE yield data. Regression analyses between model estimates and data from IBGE surveys resulted in significant coefficients of determination, with less dispersion in the South than in the North and Northeast regions of the country. Index of model efficiency (E1') ranged from 0.01 in the lower yield classes to 0.45 in higher ones, and mean absolute error ranged from 58 to 250 kg ha‑1, respectively.
Resumo:
The objective of this work was to evaluate the feasibility of simulating maize yield in a sub‑tropical region of southern Brazil using the general large area model (Glam). A 16‑year time series of daily weather data were used. The model was adjusted and tested as an alternative for simulating maize yield at small and large spatial scales. Simulated and observed grain yields were highly correlated (r above 0.8; p<0.01) at large scales (greater than 100,000 km²), with variable and mostly lower correlations (r from 0.65 to 0.87; p<0.1) at small spatial scales (lower than 10,000 km²). Large area models can contribute to monitoring or forecasting regional patterns of variability in maize production in the region, providing a basis for agricultural decision making, and Glam‑Maize is one of the alternatives.
Resumo:
OBJECTIVE: To compare the heart-rate monitoring with the doubly labelled water (2H2(18)O) method to estimate total daily energy expenditure in obese and non-obese children. DESIGN: Cross sectional study of obese and normal weight children. SUBJECTS: 13 prepubertal children: six obese (4M, 2F, 9.1 +/- 1.5 years, 47.3 +/- 9.7 kg) and seven non-obese (3M, 4F, 9.3 +/- 0.6 years, 31.8 +/- 3.2 kg). MEASUREMENTS: Total daily energy expenditure was assessed by means of the doubly labelled water method (TEEDLW) and of heart-rate monitoring (TEEHR). RESULTS: TEEHR was significantly (P < 0.05) higher than TEEDLW in obese children (9.47 +/- 0.84 MJ/d vs 8.99 +/- 0.63 MJ/d) whereas it was not different in non-obese children (8.43 +/- 2.02 MJ/d vs 8.42 +/- 2.30 MJ/d, P = NS). The difference of TEE assessed by HR monitoring in the obese group averaged 6.2 +/- 4.7%. At the individual level, the degree of agreement (difference between TEEHR and TEEDLW +/- 2s.d.) was low both in obese (-0.36, 1.32 MJ/d) and in non-obese children (-1.30, 1.34 MJ/d). At the group level, the agreement between the two methods was good in nonobese children (95% c.i. for the bias:-0.59, 0.63 MJ/d) but not in obese children (0.04, 0.92 MJ/d). Duration of sleep and energy expenditure during resting and physical activity were not significantly different in the two groups. Patterns of heart-rate (or derived energy expenditure) during the day-time were similar in obese and non-obese children. CONCLUSION: The HR monitoring technique provides an estimation of TEE close to that assessed by the DLW method in non-obese prepubertal children. In comparison with DLW, the HR monitoring method yields a greater TEE value in obese children.
Resumo:
The conditions for the analysis of selected doping substances by UHPSFC-MS/MS were optimized to ensure suitable peak shapes and maximized MS responses. A representative mixture of 31 acidic and basic doping agents was analyzed, in both ESI+ and ESI- modes. The best compromise for all compounds in terms of MS sensitivity and chromatographic performance was obtained when adding 2% water and 10mM ammonium formate in the CO2/MeOH mobile phase. Beside mobile phase, the nature of the make-up solvent added for interfacing UHPSFC with MS was also evaluated. Ethanol was found to be the best candidate as it was able to compensate for the negative effect of 2% water addition in ESI- mode and provided a suitable MS response for all doping agents. Sensitivity of the optimized UHPSFC-MS/MS method was finally assessed and compared to the results obtained in conventional UHPLC-MS/MS. Sensitivity was improved by 5-100-fold in UHPSFC-MS/MS vs. UHPLC-MS/MS for 56% of compounds, while only one compound (bumetanide) offered a significantly higher MS response (4-fold) under UHPLC-MS/MS conditions. In the second paper of this series, the optimal conditions for UHPSFC-MS/MS analysis will be employed to screen >100 doping agents in urine matrix and results will be compared to those obtained by conventional UHPLC-MS/MS.
Resumo:
BACKGROUND: The quantification of total (free+sulfated) metanephrines in urine is recommended to diagnose pheochromocytoma. Urinary metanephrines include metanephrine itself, normetanephrine and methoxytyramine, mainly in the form of sulfate conjugates (60-80%). Their determination requires the hydrolysis of the sulfate ester moiety to allow electrochemical oxidation of the phenolic group. Commercially available urine calibrators and controls contain essentially free, unhydrolysable metanephrines which are not representative of native urines. The lack of appropriate calibrators may lead to uncertainty regarding the completion of the hydrolysis of sulfated metanephrines, resulting in incorrect quantification. METHODS: We used chemically synthesized sulfated metanephrines to establish whether the procedure most frequently recommended for commercial kits (pH 1.0 for 30 min over a boiling water bath) ensures their complete hydrolysis. RESULTS: We found that sulfated metanephrines differ in their optimum pH to obtain complete hydrolysis. Highest yields and minimal variance were established for incubation at pH 0.7-0.9 during 20 min. CONCLUSION: Urinary pH should be carefully controlled to ensure an efficient and reproducible hydrolysis of sulfated metanephrines. Synthetic sulfated metanephrines represent the optimal material for calibrators and proficiency testing to improve inter-laboratory accuracy.