888 resultados para Maximal voluntary ventilation
Resumo:
This study aimed to investigate the influence of calf genetic group on the performance of Nellore lactating cows. The variables studied included milk ingestion, pasture intake, calf weight gain and cow body weight. A total of 13 Nellore calves and 8 crossbred Simental x Nellore calves were used, all born from Nellore mothers. During the experimental period of 210 days, calves were weighted at birth and at 30-day intervals, whereas cows were weighed every 14 days. Milk intake was estimated using the weigh-suckle-weigh method. Pasture intake was determined 6, 12, and 24 weeks after birth by using chromic oxide as an external marker and indigestible acid detergent fiber as an internal marker. Average weight of crossbred calves was 10.1 kg and their milk intake was 0.42 kg higher than in purebred calves. There was no difference, however, in pasture intake between genetic groups. In Nellore cows, body weight and pasture consumption (9.2 kg of DM/cow/day) were not influenced by calf heterosis.
Resumo:
This study aimed to investigate the influence of calf genetic group on the performance of Nellore lactating cows. The variables studied included milk ingestion, pasture intake, calf weight gain and cow body weight. A total of 13 Nellore calves and 8 crossbred Simental × Nellore calves were used, all born from Nellore mothers. During the experimental period of 210 days, calves were weighted at birth and at 30-day intervals, whereas cows were weighed every 14 days. Milk intake was estimated using the weigh-suckle-weigh method. Pasture intake was determined 6, 12, and 24 weeks after birth by using chromic oxide as an external marker and indigestible acid detergent fiber as an internal marker. Average weight of crossbred calves was 10.1 kg and their milk intake was 0.42 kg higher than in purebred calves. There was no difference, however, in pasture intake between genetic groups. In Nellore cows, body weight and pasture consumption (9.2 kg of DM/cow/day) were not influenced by calf heterosis.
Resumo:
Purpose: To evaluate the effects of mechanical ventilation (MV) of high-oxygen concentration in pulmonary dysfunction in adult and elderly rats. Methods: Twenty-eight adult (A) and elderly (E), male rats were ventilated for 1 hour (G-AV1 and G-EV1) or for 3 hours (G-AV3 and G-EV3). A and E groups received a tidal volume of 7 mL/kg, a positive end-expiratory pressure of 5 cm H2O, respiratory rate of 70 cycles per minute, and an inspiratory fraction of oxygen of 1. We evaluated total protein content and malondialdehyde in bronchoalveolar lavages (BAL) and performed lung histomorphometrical analyses. Results: In G-EV1 animals, total protein in BAL was higher (33.0 +/- 1.9 mu g/mL) compared with G-AV1 (23.0 +/- 2.0 mu g/mL). Upon 180 minutes of MV, malondialdehyde levels increased in elderly (G-EV3) compared with adult (G-AV3) groups. Malondialdehyde and total proteins in BAL after 3 hours of MV were higher in elderly group than in adults. In G-EV3 group we observed alveolar septa dilatation and significative increase in neutrofiles number in relation to adult group at 60 and 180 minutes on MV. Conclusion: A higher fraction of inspired oxygen in short courses of mechanical ventilation ameliorates the parameters studied in elderly lungs.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
FUNDAMENTO: Ausência de estudos na literatura validando equações preditivas da frequência cardíaca máxima (FCmáx) em crianças e adolescentes. OBJETIVO: Analisar a validade das equações preditivas da FCmáx 220 - idade e 208 - (0,7 x idade) em meninos com idades entre 10 e 16 anos. MÉTODOS: Um teste progressivo de esforço máximo foi realizado em 69 meninos com idades entre 10 e 16 anos, aparentemente saudáveis e ativos. A velocidade inicial do teste foi de 9 km/h com incrementos de 1 km/h a cada três minutos. O teste foi mantido até a exaustão voluntária, considerando-se como FCmáx a maior frequência cardíaca atingida durante o teste. A FCmáx medida foi comparada com os valores preditos pelas equações 220 - idade e 208 - (0,7 x idade) através da ANOVA, medidas repetidas. Resultados: Os valores médios da FCmáx (bpm) foram: 200,2 ± 8,0 (medida), 207,4 ± 1,5 (220 - idade) e 199,2 ± 1,1 (208 - (0,7 x idade)). A FCmáx predita pela equação 220 - idade foi significantemente maior (p < 0,001) que a FCmáx medida e que a FCmáx predita pela equação (208 - (0,7 x idade)). A correlação entre a FCmáx medida e a idade não foi estatisticamente significativa (r = 0,096; p > 0,05). CONCLUSÃO: A equação 220 - idade superestimou a FCmáx medida e não se mostrou válida para essa população. A equação 208 - (0,7 x idade) se mostrou válida apresentando resultados bastante próximos da FCmáx medida. Estudos futuros estudos com amostras maiores poderão comprovar se a FCmáx não depende da idade para essa população, situação em que o valor constante de 200 bpm seria mais apropriado para a FCmáx.
Resumo:
The maximal lactate steady state (MLSS) is the highest blood lactate concentration that can be identified as maintaining a steady state during a prolonged submaximal constant workload. The objective of the present study was to analyze the influence of the aerobic capacity on the validity of anaerobic threshold (AT) to estimate the exercise intensity at MLSS (MLSS intensity) during cycling. Ten untrained males (UC) and 9 male endurance cyclists (EC) matched for age, weight and height performed one incremental maximal load test to determine AT and two to four 30-min constant submaximal load tests on a mechanically braked cycle ergometer to determine MLSS and MLSS intensity. AT was determined as the intensity corresponding to 3.5 mM blood lactate. MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. MLSS intensity (EC = 282.1 ± 23.8 W; UC = 180.2 ± 24.5 W) and AT (EC = 274.8 ± 24.9 W; UC = 187.2 ± 28.0 W) were significantly higher in trained group. However, there was no significant difference in MLSS between EC (5.0 ± 1.2 mM) and UC (4.9 ± 1.7 mM). The MLSS intensity and AT were not different and significantly correlated in both groups (EC: r = 0.77; UC: r = 0.81). We conclude that MLSS and the validity of AT to estimate MLSS intensity during cycling, analyzed in a cross-sectional design (trained x sedentary), do not depend on the aerobic capacity.
Resumo:
O objetivo do presente estudo foi avaliar a aptidão aeróbia em testes de caminhada com carga externa aplicada por meio da inclinação da esteira, a partir da relação não linear entre inclinação da esteira e tempo até a exaustão em velocidade fixa. Doze indivíduos do gênero masculino com 23,2 ± 2,7 anos de idade, 74,0 ± 7,9kg de massa corporal e 23,7 ± 2,5kg·(m²)-1 de IMC, realizaram duas etapas de testes de caminhada em esteira ergométrica com velocidade fixa de 5,5km·h-1 em todos os testes e sobrecarga de intensidade aplicada por meio de inclinação da esteira (%). A etapa 1 consistiu de três testes retangulares até a exaustão voluntária, nas intensidades de 18%, 20% e 22% de inclinação, para determinação dos parâmetros do modelo de potência crítica por dois modelos lineares e um hiperbólico. A etapa 2 consistiu na determinação da intensidade correspondente ao máximo estado estável de lactato sanguíneo (MEEL). ANOVA demonstrou que o modelo hiperbólico (15,4 ± 1,1%) resultou em estimativa significativamente menor que os outros dois modelos lineares inclinação-tempo-1 (16,0 ± 1,0%) e hiperbólico linearizado tempo-1-inclinação (15,9 ± 1,0%), porém, houve alta correlação entre os modelos. Os dois modelos lineares superestimaram a intensidade do MEEL (14,1 ± 1,4%), e o modelo hiperbólico, mesmo sem diferença estatística, apresentou fraca correlação, com baixa concordância em relação ao MEEL. Conclui-se que a relação inclinação-tempo até a exaustão, em testes de caminhada, não permitem a estimativa de intensidade de exercício suportável por longo período de tempo.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of this study was to compare the power corresponding to maximal lactate steady state determined through continuous (MLSSC) and intermittent protocol with active recovery (MLSSI). Ten trained male cyclists (25 +/- 4 yr., 72.5 +/- 10.6 kg, 178.5 +/- 4.0 cm), performed the following tests on a cycle ergometer: (1) incremental test until voluntary exhaustion to determine the maximal power (Pmax); (2) two to five constant workload tests to determine MLSSC, and; 3) two to three constant workload tests to determine MLSSI, consisting on eight repetitions of four minutes interspersed by two minutes of recovery at 50% Pmax. The MLSSC (273.2 +/- 21.4 W) was significantly lower than MLSSI (300.5 +/- 23.9 W). With base on these data, it can be verified that the intermittent exercise mode utilized in this study, allows an increase of 10% approximately, in the exercise intensity corresponding to MLSS.
Determination of the lactate threshold and maximal blood lactate steady state intensity in aged rats
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)