817 resultados para Low Impact Urban Design
Resumo:
Email has been used for some years as a low-cost telemedicine medium to provide support for developing countries. However, all operations have been relatively small scale and fairly labour intensive to administer. A scalable, automatic message-routing system was constructed which automates many of the tasks. During a four-month study period in 2002, 485 messages were processed automatically. There were 31 referrals from eight hospitals in three countries. These referrals were handled by 25 volunteer specialists from a panel of 42. Two system operators, located 10 time zones apart, managed the system. The median time from receipt of a new referral to its allocation to a specialist was 1.0 days (interquartile range 0.7-2.4). The median interval between allocation and first reply was 0.7 days (interquartile range 0.3-2.3). Automatic message handling solves many of the problems of manual email telemedicine systems and represents a potentially scalable way of doing low-cost telemedicine in the developing world.
Resumo:
Oggi, i dispositivi portatili sono diventati la forza trainante del mercato consumer e nuove sfide stanno emergendo per aumentarne le prestazioni, pur mantenendo un ragionevole tempo di vita della batteria. Il dominio digitale è la miglior soluzione per realizzare funzioni di elaborazione del segnale, grazie alla scalabilità della tecnologia CMOS, che spinge verso l'integrazione a livello sub-micrometrico. Infatti, la riduzione della tensione di alimentazione introduce limitazioni severe per raggiungere un range dinamico accettabile nel dominio analogico. Minori costi, minore consumo di potenza, maggiore resa e una maggiore riconfigurabilità sono i principali vantaggi dell'elaborazione dei segnali nel dominio digitale. Da più di un decennio, diverse funzioni puramente analogiche sono state spostate nel dominio digitale. Ciò significa che i convertitori analogico-digitali (ADC) stanno diventando i componenti chiave in molti sistemi elettronici. Essi sono, infatti, il ponte tra il mondo digitale e analogico e, di conseguenza, la loro efficienza e la precisione spesso determinano le prestazioni globali del sistema. I convertitori Sigma-Delta sono il blocco chiave come interfaccia in circuiti a segnale-misto ad elevata risoluzione e basso consumo di potenza. I tools di modellazione e simulazione sono strumenti efficaci ed essenziali nel flusso di progettazione. Sebbene le simulazioni a livello transistor danno risultati più precisi ed accurati, questo metodo è estremamente lungo a causa della natura a sovracampionamento di questo tipo di convertitore. Per questo motivo i modelli comportamentali di alto livello del modulatore sono essenziali per il progettista per realizzare simulazioni veloci che consentono di identificare le specifiche necessarie al convertitore per ottenere le prestazioni richieste. Obiettivo di questa tesi è la modellazione del comportamento del modulatore Sigma-Delta, tenendo conto di diverse non idealità come le dinamiche dell'integratore e il suo rumore termico. Risultati di simulazioni a livello transistor e dati sperimentali dimostrano che il modello proposto è preciso ed accurato rispetto alle simulazioni comportamentali.
Resumo:
In this paper we describe the design and fabrication of a mechanical autonomous impact oscillator with a MEMS resonator as the frequency control element. The design has been developed with scalability to large 2-D arrays of coupled oscillators in mind. The dynamic behaviour of the impact oscillator was numerically studied and it was found that the geometry nonlinearity has an effect on the static pull-in voltage and equilibrium position. The external driving power can alter the frequency of the impact oscillator. The autonomous nature of the oscillator simplifies the complexity of the drive circuitry and is essential for large 2-D arrays.
Resumo:
PURPOSE: To design and validate a vision-specific quality-of-life assessment tool to be used in a clinical setting to evaluate low-vision rehabilitation strategy and management. METHODS: Previous vision-related questionnaires were assessed by low-vision rehabilitation professionals and patients for relevance and coverage. The 74 items selected were pretested to ensure correct interpretation. One hundred and fifty patients with low vision completed the chosen questions on four occasions to allow the selection of the most appropriate items. The vision-specific quality of life of patients with low vision was compared with that of 70 age-matched and gender-matched patients with normal vision and before and after low-vision rehabilitation in 278 patients. RESULTS: Items that were unreliable, internally inconsistent, redundant, or not relevant were excluded, resulting in the 25-item Low Vision Quality-of-Life Questionnaire (LVQOL). Completion of the LVQOL results in a summed score between 0 (a low quality of life) and 125 (a high quality of life). The LVQOL has a high internal consistency (α = 0.88) and good reliability (0.72). The average LVQOL score for a population with low vision (60.9 ± 25.1) was significantly lower than the average score of those with normal vision (100.3 ± 20.8). Rehabilitation improved the LVQOL score of those with low vision by an average of 6.8 ± 15.6 (17%). CONCLUSIONS: The LVQOL was shown to be an internally consistent, reliable, and fast method for measuring the vision-specific quality of life of the visually impaired in a clinical setting. It is able to quantify the quality of life of those with low vision and is useful in determining the effects of low-vision rehabilitation. Copyright (C) 2000 Elsevier Science Inc.
Resumo:
The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.
Resumo:
Purpose. To evaluate the influence of soft contact lens midperipheral shape profile and edge design on the apparent epithelial thickness and indentation of the ocular surface with lens movement. Methods. Four soft contact lens designs comprising of two different plano midperipheral shape profiles and two edge designs (chiseled and knife edge) of silicone-hydrogel material were examined in 26 subjects aged 24.7 ± 4.6 years, each worn bilaterally in randomized order. Lens movement was imaged enface on insertion, at 2 and 4 hours with a high-speed, high-resolution camera simultaneous to the cross-section of the edge of the contact lens interaction with the ocular surface captured using optical coherence tomography (OCT) nasally, temporally, and inferiorly. Optical imaging distortions were individually corrected for by imaging the apparent distortion of a glass slide surface by the removed lens. Results. Apparent epithelial thickness varied with edge position (P < 0.001). When distortion was corrected for, epithelial indentation decreased with time after insertion (P = 0.010), changed after a blink (P < 0.001), and varied with position on the lens edge (P < 0.001), with the latter being affected by midperipheral lens shape profile and edge design. Horizontal and vertical lens movement did not change with time postinsertion. Vertical motion was affected by midperipheral lens shape profile (P < 0.001) and edge design (P < 0.001). Lens movement was associated with physiologic epithelium thickness for lens midperipheral shape profile and edge designs. Conclusions. Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles. © 2013 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
Efforts to address the problems of literacy are often focused on developing countries. However, functional illiteracy is a challenge encountered by up to 50% of adults in developed countries. In this paper we reflect on the challenges we faced in trying to design and study the use of a mobile application to support adult literacy with two user groups: adults enrolled in literacy classes and carpenters without a high school education enrolled in an essential skills program. We also elaborate on aspects of the evaluations that are specific to a marginalized, functionally illiterate, group in a developed country - aspects that are less frequently present in similar studies of mobile literacy support technologies in developing countries. We conclude with presenting the lessons learnt from our evaluations and the impact of the studies' specific challenges on the outcome and uptake of such mobile assistive technologies in providing practical support to low-literacy adults in conjunction with literacy and essential skills training.
Resumo:
This chapter discusses engineering design and performance of various types of biomass transformation reactors. These reactors vary in their operating principle depending on the processing capacity and the nature of the desired end product, that is, gas, chemicals or liquid bio-oil. Mass balance around a thermal conversion reactor is usually carried out to identify the degree of conversion and obtain the amount of the various components in the product. The energy balance around the reactors is essential for determining the optimum reactor temperature and the amount of heat required to complete the overall reactions. Experimental and pilot-plant testing is essential for proper reactor design. However, it is common practice to use correlation and valid parameter values in determining the realistic reactor dimensions and configurations. Despite the recent progress in thermochemical conversion technology, reactor performance and scale up potential are the subjects of continuing research.